Webio-Digital-MIB-US Table View

Table-centric layout grouping table, row, and column objects.

Tables
160
Rows
160
Columns
1,418
.1.3.6.1.4.1.5040.1.2.4.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebioEA12x12InputEntry entry .1.3.6.1.4.1.5040.1.2.4.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x12InputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.4.1.3.1.1
wtWebioEA12x12InputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.4.1.3.1.2
wtWebioEA12x12InputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.4.1.3.1.3
wtWebioEA12x12InputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.4.1.3.1.4
.1.3.6.1.4.1.5040.1.2.4.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebioEA12x12OutputEntry entry .1.3.6.1.4.1.5040.1.2.4.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x12OutputNo mandatory
Output number.
Integer32 .1.3.6.1.4.1.5040.1.2.4.1.5.1.1
wtWebioEA12x12OutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.4.1.5.1.2
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebioEA12x12BinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.4.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x12BinaryModeNo mandatory
Number of the binary channel.
Integer32 .1.3.6.1.4.1.5040.1.2.4.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3 · 1 row entry · 22 columns
Table of properties of the binary mode.
wtWebioEA12x12BinaryEntry entry .1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x12BinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.1
wtWebioEA12x12BinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.2
wtWebioEA12x12BinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.3
wtWebioEA12x12BinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.4
wtWebioEA12x12BinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.5
wtWebioEA12x12BinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.6
wtWebioEA12x12BinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.7
wtWebioEA12x12BinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.8
wtWebioEA12x12BinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.9
wtWebioEA12x12BinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.10
wtWebioEA12x12BinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.11
wtWebioEA12x12BinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.12
wtWebioEA12x12BinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.13
wtWebioEA12x12BinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.14
wtWebioEA12x12BinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.15
wtWebioEA12x12BinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.16
wtWebioEA12x12BinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.17
wtWebioEA12x12BinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.18
wtWebioEA12x12BinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32 .1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.19
wtWebioEA12x12BinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Constraints:
range: 1-65535
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.20
wtWebioEA12x12BinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.21
wtWebioEA12x12BinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w .1.3.6.1.4.1.5040.1.2.4.3.1.3.6.3.1.22
.1.3.6.1.4.1.5040.1.2.4.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebioEA12x12OutputModeEntry entry .1.3.6.1.4.1.5040.1.2.4.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x12OutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2:…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.4.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioEA12x12AlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.4.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x12AlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.4.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.4.3.1.5.3 · 1 row entry · 32 columns
List of settings depending on the alarm number.
wtWebioEA12x12AlarmEntry entry .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x12AlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.1
wtWebioEA12x12AlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.2
wtWebioEA12x12AlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.3
wtWebioEA12x12AlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebioEA12x12AlarmInputTrigger are not c…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.4
wtWebioEA12x12AlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.5
wtWebioEA12x12AlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4: TCP Client e…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.6
wtWebioEA12x12AlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.7
wtWebioEA12x12AlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.8
wtWebioEA12x12AlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.9
wtWebioEA12x12AlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.10
wtWebioEA12x12AlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.11
wtWebioEA12x12AlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.12
wtWebioEA12x12AlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.13
wtWebioEA12x12AlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.14
wtWebioEA12x12AlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.15
wtWebioEA12x12AlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.16
wtWebioEA12x12AlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.17
wtWebioEA12x12AlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.18
wtWebioEA12x12AlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.19
wtWebioEA12x12AlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.20
wtWebioEA12x12AlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.21
wtWebioEA12x12AlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.22
wtWebioEA12x12AlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.23
wtWebioEA12x12AlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.24
wtWebioEA12x12AlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.25
wtWebioEA12x12AlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.26
wtWebioEA12x12AlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.27
wtWebioEA12x12AlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.28
wtWebioEA12x12AlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.29
wtWebioEA12x12AlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.30
wtWebioEA12x12AlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.31
wtWebioEA12x12AlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.1.5.3.1.32
.1.3.6.1.4.1.5040.1.2.4.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebioEA12x12InputPortEntry entry .1.3.6.1.4.1.5040.1.2.4.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x12PortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.2.1.1.1
wtWebioEA12x12PortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.2.1.1.2
wtWebioEA12x12PortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.4.3.2.1.1.3
wtWebioEA12x12PortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.4.3.2.1.1.4
wtWebioEA12x12PortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.4.3.2.1.1.5
wtWebioEA12x12PortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.4.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.4.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebioEA12x12OutputPortEntry entry .1.3.6.1.4.1.5040.1.2.4.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x12PortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.1
wtWebioEA12x12PortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.2
wtWebioEA12x12PortOutputGroupMode mandatory
It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be set all together in the same way. This v…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.4.3.2.2.1.3
wtWebioEA12x12PortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.4.3.2.2.1.4
wtWebioEA12x12PortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (w…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.5
wtWebioEA12x12PortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: Bit 0-3 : inputs 8-11
Bit 4-7 : unused
OCTET 4:
Bit 0-7 : inputs 0-7
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.6
wtWebioEA12x12PortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.7
wtWebioEA12x12PortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enable
Bit 1-7 : unused
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.4.3.2.2.1.8
wtWebioEA12x12PortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.4.3.2.2.1.9
wtWebioEA12x12PortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebioEA12x12PortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused
OC…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.10

wtWebioEA2x2InputTable

table mandatory
.1.3.6.1.4.1.5040.1.2.13.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebioEA2x2InputEntry entry .1.3.6.1.4.1.5040.1.2.13.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2InputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.13.1.3.1.1
wtWebioEA2x2InputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.13.1.3.1.2
wtWebioEA2x2InputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.13.1.3.1.3
wtWebioEA2x2InputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Constraints:
range: 1-65535
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.13.1.3.1.4
.1.3.6.1.4.1.5040.1.2.13.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebioEA2x2OutputEntry entry .1.3.6.1.4.1.5040.1.2.13.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2OutputNo mandatory
Output number.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.13.1.5.1.1
wtWebioEA2x2OutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Constraints:
range: 1-65535
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.13.1.5.1.2
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebioEA2x2BinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.13.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2BinaryModeNo mandatory
Number of the binary channel.
Integer32 .1.3.6.1.4.1.5040.1.2.13.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3 · 1 row entry · 22 columns
Table of properties of the binary mode.
wtWebioEA2x2BinaryEntry entry .1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2BinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.1
wtWebioEA2x2BinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.2
wtWebioEA2x2BinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.3
wtWebioEA2x2BinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.4
wtWebioEA2x2BinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.5
wtWebioEA2x2BinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.6
wtWebioEA2x2BinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.7
wtWebioEA2x2BinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.8
wtWebioEA2x2BinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.9
wtWebioEA2x2BinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.10
wtWebioEA2x2BinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.11
wtWebioEA2x2BinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.12
wtWebioEA2x2BinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.13
wtWebioEA2x2BinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.14
wtWebioEA2x2BinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.15
wtWebioEA2x2BinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.16
wtWebioEA2x2BinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w
Constraints:
range: 1-12
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.17
wtWebioEA2x2BinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.18
wtWebioEA2x2BinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32 .1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.19
wtWebioEA2x2BinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Constraints:
range: 12-12
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.20
wtWebioEA2x2BinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.21
wtWebioEA2x2BinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.1.3.6.3.1.22
.1.3.6.1.4.1.5040.1.2.13.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebioEA2x2OutputModeEntry entry .1.3.6.1.4.1.5040.1.2.13.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2OutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corres…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.13.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioEA2x2AlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.13.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2AlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.13.3.1.5.2.1.1

wtWebioEA2x2AlarmTable

table mandatory
.1.3.6.1.4.1.5040.1.2.13.3.1.5.3 · 1 row entry · 32 columns
List of settings depending on the alarm number.
wtWebioEA2x2AlarmEntry entry .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2AlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.1
wtWebioEA2x2AlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.2
wtWebioEA2x2AlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.3
wtWebioEA2x2AlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebioEA2x2AlarmInputTrigger are not con…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.4
wtWebioEA2x2AlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.5
wtWebioEA2x2AlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4: TCP Client e…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.6
wtWebioEA2x2AlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.7
wtWebioEA2x2AlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.8
wtWebioEA2x2AlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.9
wtWebioEA2x2AlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.10
wtWebioEA2x2AlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.11
wtWebioEA2x2AlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.12
wtWebioEA2x2AlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.13
wtWebioEA2x2AlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.14
wtWebioEA2x2AlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.15
wtWebioEA2x2AlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.16
wtWebioEA2x2AlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.17
wtWebioEA2x2AlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.18
wtWebioEA2x2AlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.19
wtWebioEA2x2AlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.20
wtWebioEA2x2AlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.21
wtWebioEA2x2AlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.22
wtWebioEA2x2AlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.23
wtWebioEA2x2AlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.24
wtWebioEA2x2AlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.25
wtWebioEA2x2AlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.26
wtWebioEA2x2AlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.27
wtWebioEA2x2AlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.28
wtWebioEA2x2AlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.29
wtWebioEA2x2AlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.30
wtWebioEA2x2AlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.31
wtWebioEA2x2AlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.1.5.3.1.32
.1.3.6.1.4.1.5040.1.2.13.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebioEA2x2InputPortEntry entry .1.3.6.1.4.1.5040.1.2.13.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2PortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.2.1.1.1
wtWebioEA2x2PortInputText mandatory
Description of the input.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.2.1.1.2
wtWebioEA2x2PortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.2.1.1.3
wtWebioEA2x2PortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.13.3.2.1.1.4
wtWebioEA2x2PortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.13.3.2.1.1.5
wtWebioEA2x2PortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.13.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.13.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebioEA2x2OutputPortEntry entry .1.3.6.1.4.1.5040.1.2.13.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2PortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.2.2.1.1
wtWebioEA2x2PortOutputText mandatory
Description of the output.
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.13.3.2.2.1.2
wtWebioEA2x2PortOutputGroupMode mandatory
It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be set all together in the same way. This v…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.13.3.2.2.1.3
wtWebioEA2x2PortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.2.2.1.4
wtWebioEA2x2PortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (w…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.2.2.1.5
wtWebioEA2x2PortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 0-1 : inputs 0-1
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.2.2.1.6
wtWebioEA2x2PortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.2.2.1.7
wtWebioEA2x2PortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enable
Bit 1-7 : unused
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.13.3.2.2.1.8
wtWebioEA2x2PortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.13.3.2.2.1.9
wtWebioEA2x2PortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebioEA2x2PortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused
OCTE…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.13.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.14.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebioEA24oemInputEntry entry .1.3.6.1.4.1.5040.1.2.14.1.3.1
Numbers of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA24oemInputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.14.1.3.1.1
wtWebioEA24oemInputCounter mandatory
Value of the input counter.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.14.1.3.1.2
wtWebioEA24oemInputCounterClear mandatory
Value of the input counter. After reading this counter will be cleared.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.14.1.3.1.3
wtWebioEA24oemInputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Constraints:
range: 1-12
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.14.1.3.1.4
.1.3.6.1.4.1.5040.1.2.14.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebioEA24oemOutputEntry entry .1.3.6.1.4.1.5040.1.2.14.1.5.1
Numbers of the outputs.
Indexes
wtWebAlarm6x6AlarmNo
Column Syntax OID
wtWebioEA24oemOutputNo mandatory
Index numbers of the outputs.
Integer32
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.14.1.5.1.1
wtWebioEA24oemOutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.14.1.5.1.2
.1.3.6.1.4.1.5040.1.2.14.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebioEA24oemBinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA24oemBinaryModeNo mandatory
Number of the binary channel.
Integer32 .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3 · 1 row entry · 22 columns
Table of properties of the binary mode.
wtWebioEA24oemBinaryEntry entry .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA24oemBinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.1
wtWebioEA24oemBinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.2
wtWebioEA24oemBinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.3
wtWebioEA24oemBinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.4
wtWebioEA24oemBinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.5
wtWebioEA24oemBinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.6
wtWebioEA24oemBinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.7
wtWebioEA24oemBinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.8
wtWebioEA24oemBinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.9
wtWebioEA24oemBinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.10
wtWebioEA24oemBinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.11
wtWebioEA24oemBinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.12
wtWebioEA24oemBinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.13
wtWebioEA24oemBinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.14
wtWebioEA24oemBinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.15
wtWebioEA24oemBinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.16
wtWebioEA24oemBinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.17
wtWebioEA24oemBinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.18
wtWebioEA24oemBinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32 .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.19
wtWebioEA24oemBinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.20
wtWebioEA24oemBinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.21
wtWebioEA24oemBinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.22
.1.3.6.1.4.1.5040.1.2.14.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebioEA24oemOutputModeEntry entry .1.3.6.1.4.1.5040.1.2.14.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA24oemOutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.14.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioEA24oemAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.14.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA24oemAlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.14.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.14.3.1.5.3 · 1 row entry · 25 columns
List of settings depending on the alarm number.
wtWebioEA24oemAlarmEntry entry .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA24oemAlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.1
wtWebioEA24oemAlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.2
wtWebioEA24oemAlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.3
wtWebioEA24oemAlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebioEA24oemAlarmInputTrigger are not c…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.4
wtWebioEA24oemAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.5
wtWebioEA24oemAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4-7: unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.6
wtWebioEA24oemAlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.7
wtWebioEA24oemAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.8
wtWebioEA24oemAlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.9
wtWebioEA24oemAlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.10
wtWebioEA24oemAlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.11
wtWebioEA24oemAlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.12
wtWebioEA24oemAlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.13
wtWebioEA24oemAlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.14
wtWebioEA24oemAlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.15
wtWebioEA24oemAlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.16
wtWebioEA24oemAlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.17
wtWebioEA24oemAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.18
wtWebioEA24oemAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.19
wtWebioEA24oemAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.20
wtWebioEA24oemAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.21
wtWebioEA24oemAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.22
wtWebioEA24oemAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.23
wtWebioEA24oemAlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.24
wtWebioEA24oemAlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.1.5.3.1.25
.1.3.6.1.4.1.5040.1.2.14.3.2.1 · 1 row entry · 4 columns
List of settings depending on the input number.
wtWebioEA24oemInputPortEntry entry .1.3.6.1.4.1.5040.1.2.14.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA24oemPortInputName mandatory
Name of the input.
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.14.3.2.1.1.1
wtWebioEA24oemPortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.2.1.1.2
wtWebioEA24oemPortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.2.1.1.3
wtWebioEA24oemPortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.14.3.2.1.1.4
.1.3.6.1.4.1.5040.1.2.14.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebioEA24oemOutputPortEntry entry .1.3.6.1.4.1.5040.1.2.14.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA24oemPortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.1
wtWebioEA24oemPortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.2
wtWebioEA24oemPortOutputGroupMode mandatory
It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be set all together in the same way. This v…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.3
wtWebioEA24oemPortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w
Constraints:
range: 1-12
.1.3.6.1.4.1.5040.1.2.14.3.2.2.1.4
wtWebioEA24oemPortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (wt…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.5
wtWebioEA24oemPortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: Bit 0-7 : inputs 16 - 23
OCTET 3: Bit 0-7 : inputs 8 - 15
OCTET 4: Bit 0-7 : inputs 0 - 7
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.6
wtWebioEA24oemPortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.14.3.2.2.1.7
wtWebioEA24oemPortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enable
Bit 1-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.8
wtWebioEA24oemPortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.14.3.2.2.1.9
wtWebioEA24oemPortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebioEA24oemPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused
OC…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.19.1.3 · 1 row entry · 3 columns
List of input indices.
wtWebioEA12x6RelInputEntry entry .1.3.6.1.4.1.5040.1.2.19.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelInputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.19.1.3.1.1
wtWebioEA12x6RelInputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.19.1.3.1.2
wtWebioEA12x6RelInputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.19.1.3.1.3
.1.3.6.1.4.1.5040.1.2.19.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebioEA12x6RelOutputEntry entry .1.3.6.1.4.1.5040.1.2.19.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelOutputNo mandatory
Output number.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.19.1.5.1.1
wtWebioEA12x6RelOutputState mandatory
Setting and reading of the states of the outputs, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.19.1.5.1.2
.1.3.6.1.4.1.5040.1.2.19.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebioEA12x6RelBinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelBinaryModeNo mandatory
Number of the binary channel.
Integer32 .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3 · 1 row entry · 22 columns
Table of properties of the binary mode.
wtWebioEA12x6RelBinaryEntry entry .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelBinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.1
wtWebioEA12x6RelBinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.2
wtWebioEA12x6RelBinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.3
wtWebioEA12x6RelBinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.4
wtWebioEA12x6RelBinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.5
wtWebioEA12x6RelBinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.6
wtWebioEA12x6RelBinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.7
wtWebioEA12x6RelBinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.8
wtWebioEA12x6RelBinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.9
wtWebioEA12x6RelBinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.10
wtWebioEA12x6RelBinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.11
wtWebioEA12x6RelBinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.12
wtWebioEA12x6RelBinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.13
wtWebioEA12x6RelBinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.14
wtWebioEA12x6RelBinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.15
wtWebioEA12x6RelBinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.16
wtWebioEA12x6RelBinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.17
wtWebioEA12x6RelBinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.18
wtWebioEA12x6RelBinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.19
wtWebioEA12x6RelBinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.20
wtWebioEA12x6RelBinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.21
wtWebioEA12x6RelBinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w .1.3.6.1.4.1.5040.1.2.19.3.1.3.6.3.1.22
.1.3.6.1.4.1.5040.1.2.19.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebioEA12x6RelOutputModeEntry entry .1.3.6.1.4.1.5040.1.2.19.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelOutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an output.
Bi…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.19.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioEA12x6RelAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.19.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelAlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.19.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3 · 1 row entry · 32 columns
List of settings depending on the alarm number.
wtWebioEA12x6RelAlarmEntry entry .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelAlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.1
wtWebioEA12x6RelAlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.2
wtWebioEA12x6RelAlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.3
wtWebioEA12x6RelAlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebioEA12x6RelAlarmInputTrigger are not…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.4
wtWebioEA12x6RelAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.5
wtWebioEA12x6RelAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4: TCP Client e…
OctetStringr/w
Constraints:
range: 1-2
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.6
wtWebioEA12x6RelAlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.7
wtWebioEA12x6RelAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.8
wtWebioEA12x6RelAlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.9
wtWebioEA12x6RelAlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.10
wtWebioEA12x6RelAlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.11
wtWebioEA12x6RelAlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.12
wtWebioEA12x6RelAlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.13
wtWebioEA12x6RelAlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.14
wtWebioEA12x6RelAlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.15
wtWebioEA12x6RelAlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.16
wtWebioEA12x6RelAlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.17
wtWebioEA12x6RelAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.18
wtWebioEA12x6RelAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.19
wtWebioEA12x6RelAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.20
wtWebioEA12x6RelAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.21
wtWebioEA12x6RelAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.22
wtWebioEA12x6RelAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.23
wtWebioEA12x6RelAlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.24
wtWebioEA12x6RelAlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.25
wtWebioEA12x6RelAlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.26
wtWebioEA12x6RelAlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.27
wtWebioEA12x6RelAlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.28
wtWebioEA12x6RelAlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.29
wtWebioEA12x6RelAlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.30
wtWebioEA12x6RelAlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.31
wtWebioEA12x6RelAlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.1.5.3.1.32
.1.3.6.1.4.1.5040.1.2.19.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebioEA12x6RelInputPortEntry entry .1.3.6.1.4.1.5040.1.2.19.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelPortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.2.1.1.1
wtWebioEA12x6RelPortInputText mandatory
Description of the input.
OctetStringr/w
Constraints:
range: 1-12
.1.3.6.1.4.1.5040.1.2.19.3.2.1.1.2
wtWebioEA12x6RelPortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.2.1.1.3
wtWebioEA12x6RelPortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.19.3.2.1.1.4
wtWebioEA12x6RelPortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.19.3.2.1.1.5
wtWebioEA12x6RelPortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Constraints:
range: 12-12
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.19.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.19.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebioEA12x6RelOutputPortEntry entry .1.3.6.1.4.1.5040.1.2.19.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelPortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.1
wtWebioEA12x6RelPortOutputText mandatory
Description of the output.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.19.3.2.2.1.2
wtWebioEA12x6RelPortOutputGroupMode mandatory
Unused in this device 57634
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.3
wtWebioEA12x6RelPortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.4
wtWebioEA12x6RelPortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (w…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.5
wtWebioEA12x6RelPortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: Bit 0-3 : inputs 8-11
Bit 4-7 : unused
OCTET 4:
Bit 0-7 : inputs 0-7
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.6
wtWebioEA12x6RelPortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.7
wtWebioEA12x6RelPortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enable
Bit 1-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.8
wtWebioEA12x6RelPortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Constraints:
range: 1-65535
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.19.3.2.2.1.9
wtWebioEA12x6RelPortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebioEA12x6RelPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.20.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebAlarm6x6InputEntry entry .1.3.6.1.4.1.5040.1.2.20.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebAlarm6x6InputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.20.1.3.1.1
wtWebAlarm6x6InputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.20.1.3.1.2
wtWebAlarm6x6InputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Constraints:
range: 1-65535
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.20.1.3.1.3
wtWebAlarm6x6InputState mandatory
States of the inputs, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.20.1.3.1.4
.1.3.6.1.4.1.5040.1.2.20.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebAlarm6x6OutputEntry entry .1.3.6.1.4.1.5040.1.2.20.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebAlarm6x6OutputNo mandatory
Output number.
Integer32 .1.3.6.1.4.1.5040.1.2.20.1.5.1.1
wtWebAlarm6x6OutputState mandatory
States of the outputs, 0-OFF, 1-ON.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.20.1.5.1.2
.1.3.6.1.4.1.5040.1.2.20.1.8 · 1 row entry · 2 columns
List of alarm indices..
wtWebAlarm6x6AlarmOutputEntry entry .1.3.6.1.4.1.5040.1.2.20.1.8.1
Index reference.
Indexes
No indexes recorded
Column Syntax OID
wtWebAlarm6x6AlarmOutputState mandatory
State of the alarm, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.20.1.8.1.1
wtWebAlarm6x6AlarmTriggerState mandatory
State of the trigger condition, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.20.1.8.1.2
.1.3.6.1.4.1.5040.1.2.20.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebAlarm6x6AlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.20.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebAlarm6x6AlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.20.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3 · 1 row entry · 48 columns
List of settings depending on the alarm number.
wtWebAlarm6x6AlarmEntry entry .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebAlarm6x6AlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.1
wtWebAlarm6x6AlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebAlarm6x6AlarmInputTrigger are not co…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.4
wtWebAlarm6x6AlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.5
wtWebAlarm6x6AlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Output Switch Enable
Bit 1: Mail Enable
Bit 2: SNMP Trap enable
Bit 3: UDP enable
Bit 4: unused
Bit 5: TCP Client ena…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.6
wtWebAlarm6x6AlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.7
wtWebAlarm6x6AlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.8
wtWebAlarm6x6AlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.9
wtWebAlarm6x6AlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.10
wtWebAlarm6x6AlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.11
wtWebAlarm6x6AlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.12
wtWebAlarm6x6AlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.13
wtWebAlarm6x6AlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.14
wtWebAlarm6x6AlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.15
wtWebAlarm6x6AlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.16
wtWebAlarm6x6AlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.17
wtWebAlarm6x6AlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.18
wtWebAlarm6x6AlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.19
wtWebAlarm6x6AlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.20
wtWebAlarm6x6AlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.21
wtWebAlarm6x6AlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.22
wtWebAlarm6x6AlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.23
wtWebAlarm6x6AlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.24
wtWebAlarm6x6AlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.26
wtWebAlarm6x6AlarmMailReleaseText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.27
wtWebAlarm6x6AlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.28
wtWebAlarm6x6AlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.29
wtWebAlarm6x6AlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.30
wtWebAlarm6x6AlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.31
wtWebAlarm6x6AlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.32
wtWebAlarm6x6AlarmName mandatory
Name of the alarm.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.33
wtWebAlarm6x6AlarmGlobalEnable mandatory
Binary coded alarm activation:
Die OCTETS werden bitweise interpretiert.
Bit 0 entspricht dem LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Alarm enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.34
wtWebAlarm6x6AlarmCounterClear mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : Counter clear on Alarm acknowledge
Bit 0…
OctetStringr/w
Constraints:
range: 1-2
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.35
wtWebAlarm6x6AlarmAckEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : Software acknowledge enable
Bit 0 : Hard…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.36
wtWebAlarm6x6AlarmAckPort mandatory
Number of the input, which clears the alarm (1-6).
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.37
wtWebAlarm6x6AlarmSetPort mandatory
Number of the output, which will be set by this alarm (1-6).
The configuration of pulse mode and polarity defined in the port output section is used.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.38
wtWebAlarm6x6AlarmMailTrgClearSubject mandatory
Subject line for alarm mail.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.39
wtWebAlarm6x6AlarmMailTrgClearText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.40
wtWebAlarm6x6AlarmSnmpTrapTrgClearText mandatory
This text appears in the trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.41
wtWebAlarm6x6AlarmUdpTrgClearText mandatory
This text appears in the UDP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.42
wtWebAlarm6x6AlarmTcpTrgClearText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.43
wtWebAlarm6x6AlarmSyslogTrgClearText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.44
wtWebAlarm6x6AlarmFtpTrgClearText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.45
wtWebAlarm6x6AlarmMailTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.46
wtWebAlarm6x6AlarmSnmpTrapTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.47
wtWebAlarm6x6AlarmUdpTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.48
wtWebAlarm6x6AlarmTcpTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.49
wtWebAlarm6x6AlarmSyslogTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.50
wtWebAlarm6x6AlarmFtpTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.20.3.1.5.3.1.51
.1.3.6.1.4.1.5040.1.2.20.3.2.1 · 1 row entry · 5 columns
List of settings depending on the input number.
wtWebAlarm6x6InputPortEntry entry .1.3.6.1.4.1.5040.1.2.20.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebAlarm6x6PortInputName mandatory
Name of the input.
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.20.3.2.1.1.1
wtWebAlarm6x6PortInputText mandatory
Description of the input.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.2.1.1.2
wtWebAlarm6x6PortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Constraints:
range: 1-65535
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.20.3.2.1.1.4
wtWebAlarm6x6PortInputPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.2.1.1.5
wtWebAlarm6x6PortInputCounterSet mandatory
Writing to this variable presets the counter, while reading returns the actual value.
Integer32r/w
Constraints:
range: 1-65535
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.20.3.2.1.1.7
.1.3.6.1.4.1.5040.1.2.20.3.2.2 · 1 row entry · 4 columns
List of settings depending on the output number.
wtWebAlarm6x6OutputPortEntry entry .1.3.6.1.4.1.5040.1.2.20.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebAlarm6x6PortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.2.2.1.1
wtWebAlarm6x6PortOutputText mandatory
Description of the output.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.20.3.2.2.1.2
wtWebAlarm6x6PortPulseDuration mandatory
Pulse length in 1/100 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.20.3.2.2.1.9
wtWebAlarm6x6PortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebAlarm6x6PortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused
OCT…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.20.3.2.2.1.10

wtWebCount6InputTable

table mandatory
.1.3.6.1.4.1.5040.1.2.22.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebCount6InputEntry entry .1.3.6.1.4.1.5040.1.2.22.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebCount6InputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.22.1.3.1.1
wtWebCount6InputCounter mandatory
Value of the input counter.
Integer32
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.22.1.3.1.2
wtWebCount6InputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Constraints:
range: 12-12
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.22.1.3.1.3
wtWebCount6InputState mandatory
Tates of the inputs, 0-OFF, 1-ON.
Integer32
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.22.1.3.1.4
.1.3.6.1.4.1.5040.1.2.22.1.8 · 1 row entry · 2 columns
List of Report indices..
wtWebCount6ReportOutputEntry entry .1.3.6.1.4.1.5040.1.2.22.1.8.1
Index reference.
Indexes
No indexes recorded
Column Syntax OID
wtWebCount6ReportOutputState mandatory
State of the Report, 0-OFF, 1-ON.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.22.1.8.1.1
wtWebCount6ReportTriggerState mandatory
State of the trigger condition, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.22.1.8.1.2
.1.3.6.1.4.1.5040.1.2.22.3.1.5.2 · 1 row entry · 1 columns
List of Report indices.
wtWebCount6ReportIfEntry entry .1.3.6.1.4.1.5040.1.2.22.3.1.5.2.1
Numbers of the Reports.
Indexes
No indexes recorded
Column Syntax OID
wtWebCount6ReportNo mandatory
Numbers of the Reports.
Integer32 .1.3.6.1.4.1.5040.1.2.22.3.1.5.2.1.1

wtWebCount6ReportTable

table mandatory
.1.3.6.1.4.1.5040.1.2.22.3.1.5.3 · 1 row entry · 30 columns
List of settings depending on the Report number.
wtWebCount6ReportEntry entry .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1
Report parameters of the individual Reports.
Indexes
No indexes recorded
Column Syntax OID
wtWebCount6ReportInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.1
wtWebCount6ReportSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,

Bit 7 : Timer OFF
Bit 6 : Time Window
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.3
wtWebCount6ReportMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding Report is triggered. Input counters with
its mask bit unset in wtWebCount6ReportInputTrigger are not co…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.4
wtWebCount6ReportInterval mandatory
Send interval for Report messages.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.5
wtWebCount6ReportEnable mandatory
Binary coded Report enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Output Switch Enable
Bit 1: Mail Enable
Bit 2: SNMP Trap enable
Bit 3: UDP enable
Bit 4: unused
Bit 5: TCP Client en…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.6
wtWebCount6ReportMailAddr mandatory
E-Mail address for sending the Report mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.7
wtWebCount6ReportMailSubject mandatory
Subject line for Report mail.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.8
wtWebCount6ReportMailText mandatory
Report mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.9
wtWebCount6ReportSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.10
wtWebCount6ReportSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.11
wtWebCount6ReportUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.12
wtWebCount6ReportUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.13
wtWebCount6ReportUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.14
wtWebCount6ReportTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.15
wtWebCount6ReportTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.16
wtWebCount6ReportTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.17
wtWebCount6ReportSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.18
wtWebCount6ReportSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.19
wtWebCount6ReportSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.20
wtWebCount6ReportFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.21
wtWebCount6ReportFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.22
wtWebCount6ReportFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.23
wtWebCount6ReportFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.24
wtWebCount6ReportTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a report, weekday and day of month
are interpreted separatley.
1: Minutes Range…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.25
wtWebCount6ReportName mandatory
Name of the Report.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.33
wtWebCount6ReportGlobalEnable mandatory
Binary coded Report activation:
Die OCTETS werden bitweise interpretiert.
Bit 0 entspricht dem LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Report enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.34
wtWebCount6ReportCounterClear mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Counter clear on Report send
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.35
wtWebCount6ReportRateOfChange mandatory
This variable configures a max. counter value within a time slot. If an input counter value
exceeds this max. value, the corresponding Report is triggered. Input counters with
its mask bit unset in wtWebCount6ReportInpu…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.52
wtWebCount6ReportRateOfChangeWindow mandatory
This variable configures the time slot of wtWebCount6ReportRateOfChange. Input counters with
its mask bit unset in wtWebCount6ReportInputTrigger are not considered. A value of Zero
disable the tracing of rate of change.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.53
wtWebCount6ReportRateOfChangeMode mandatory
Binary coded options:
Minimum mode: a report will be send if the count of pulses is lower than
the given pulse count in wtWebCount6ReportRateOfChange.
Maximum mode: a report will be send if the count of pulses is greate…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.54
.1.3.6.1.4.1.5040.1.2.22.3.2.1 · 1 row entry · 9 columns
List of settings depending on the input number.
wtWebCount6InputPortEntry entry .1.3.6.1.4.1.5040.1.2.22.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebCount6PortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.2.1.1.1
wtWebCount6PortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.2.1.1.2
wtWebCount6PortInputMode mandatory
Binary coded modes:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
Selection for input 0-1:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Bidirectional counter…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.22.3.2.1.1.3
wtWebCount6PortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.22.3.2.1.1.4
wtWebCount6PortInputPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.22.3.2.1.1.5
wtWebCount6PortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.22.3.2.1.1.6
wtWebCount6PortInputCounterSet mandatory
Writing to this variable presets the counter, while reading returns the actual value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.22.3.2.1.1.7
wtWebCount6PortInputCounterScale mandatory
Conversion factor for this counter.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.22.3.2.1.1.8
wtWebCount6PortInputCounterUnit mandatory
Unit for this counter.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.22.3.2.1.1.9

wtWebioEA6x6InputTable

table mandatory
.1.3.6.1.4.1.5040.1.2.24.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebioEA6x6InputEntry entry .1.3.6.1.4.1.5040.1.2.24.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA6x6InputNo mandatory
Index numbers of the inputs.
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.24.1.3.1.1
wtWebioEA6x6InputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.24.1.3.1.2
wtWebioEA6x6InputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.24.1.3.1.3
wtWebioEA6x6InputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.24.1.3.1.4
.1.3.6.1.4.1.5040.1.2.24.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebioEA6x6OutputEntry entry .1.3.6.1.4.1.5040.1.2.24.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA6x6OutputNo mandatory
Output number.
Integer32 .1.3.6.1.4.1.5040.1.2.24.1.5.1.1
wtWebioEA6x6OutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.24.1.5.1.2
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebioEA6x6BinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA6x6BinaryModeNo mandatory
Number of the binary channel.
Integer32 .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3 · 1 row entry · 22 columns
Table of properties of the binary mode.
wtWebioEA6x6BinaryEntry entry .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA6x6BinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.1
wtWebioEA6x6BinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.2
wtWebioEA6x6BinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.3
wtWebioEA6x6BinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.4
wtWebioEA6x6BinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.5
wtWebioEA6x6BinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.6
wtWebioEA6x6BinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.7
wtWebioEA6x6BinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.8
wtWebioEA6x6BinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Constraints:
range: 0-65535
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.9
wtWebioEA6x6BinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.10
wtWebioEA6x6BinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.11
wtWebioEA6x6BinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.12
wtWebioEA6x6BinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.13
wtWebioEA6x6BinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.14
wtWebioEA6x6BinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.15
wtWebioEA6x6BinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.16
wtWebioEA6x6BinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.17
wtWebioEA6x6BinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.18
wtWebioEA6x6BinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.19
wtWebioEA6x6BinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Constraints:
range: 1-65535
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.20
wtWebioEA6x6BinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.21
wtWebioEA6x6BinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.22
.1.3.6.1.4.1.5040.1.2.24.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebioEA6x6OutputModeEntry entry .1.3.6.1.4.1.5040.1.2.24.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA6x6OutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2:…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.24.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioEA6x6AlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.24.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA6x6AlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.24.3.1.5.2.1.1

wtWebioEA6x6AlarmTable

table mandatory
.1.3.6.1.4.1.5040.1.2.24.3.1.5.3 · 1 row entry · 32 columns
List of settings depending on the alarm number.
wtWebioEA6x6AlarmEntry entry .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA6x6AlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.1
wtWebioEA6x6AlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.2
wtWebioEA6x6AlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.3
wtWebioEA6x6AlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebioEA6x6AlarmInputTrigger are not con…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.4
wtWebioEA6x6AlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.5
wtWebioEA6x6AlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4: TCP Client e…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.6
wtWebioEA6x6AlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.7
wtWebioEA6x6AlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.8
wtWebioEA6x6AlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.9
wtWebioEA6x6AlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.10
wtWebioEA6x6AlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.11
wtWebioEA6x6AlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.12
wtWebioEA6x6AlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.13
wtWebioEA6x6AlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.14
wtWebioEA6x6AlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.15
wtWebioEA6x6AlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.16
wtWebioEA6x6AlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.17
wtWebioEA6x6AlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.18
wtWebioEA6x6AlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.19
wtWebioEA6x6AlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.20
wtWebioEA6x6AlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.21
wtWebioEA6x6AlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.22
wtWebioEA6x6AlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.23
wtWebioEA6x6AlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.24
wtWebioEA6x6AlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.25
wtWebioEA6x6AlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.26
wtWebioEA6x6AlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.27
wtWebioEA6x6AlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.28
wtWebioEA6x6AlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.29
wtWebioEA6x6AlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.30
wtWebioEA6x6AlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.31
wtWebioEA6x6AlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.1.5.3.1.32
.1.3.6.1.4.1.5040.1.2.24.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebioEA6x6InputPortEntry entry .1.3.6.1.4.1.5040.1.2.24.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA6x6PortInputName mandatory
Name of the input.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.2.1.1.1
wtWebioEA6x6PortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.2.1.1.2
wtWebioEA6x6PortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.2.1.1.3
wtWebioEA6x6PortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.24.3.2.1.1.4
wtWebioEA6x6PortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.2.1.1.5
wtWebioEA6x6PortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.24.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.24.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebioEA6x6OutputPortEntry entry .1.3.6.1.4.1.5040.1.2.24.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA6x6PortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.1
wtWebioEA6x6PortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.2
wtWebioEA6x6PortOutputGroupMode mandatory
It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be set all together in the same way. This v…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.2.2.1.3
wtWebioEA6x6PortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.2.2.1.4
wtWebioEA6x6PortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (w…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.2.2.1.5
wtWebioEA6x6PortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0-5 : inputs 0-5
Bit 6-7 : unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.2.2.1.6
wtWebioEA6x6PortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.7
wtWebioEA6x6PortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enable
Bit 1-7 : unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.24.3.2.2.1.8
wtWebioEA6x6PortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.24.3.2.2.1.9
wtWebioEA6x6PortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebioEA6x6PortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused
OCTE…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.25.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebioEA2x2ERPInputEntry entry .1.3.6.1.4.1.5040.1.2.25.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERPInputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.25.1.3.1.1
wtWebioEA2x2ERPInputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.25.1.3.1.2
wtWebioEA2x2ERPInputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.25.1.3.1.3
wtWebioEA2x2ERPInputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.25.1.3.1.4
.1.3.6.1.4.1.5040.1.2.25.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebioEA2x2ERPOutputEntry entry .1.3.6.1.4.1.5040.1.2.25.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERPOutputNo mandatory
Output number.
Integer32 .1.3.6.1.4.1.5040.1.2.25.1.5.1.1
wtWebioEA2x2ERPOutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.25.1.5.1.2
.1.3.6.1.4.1.5040.1.2.25.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebioEA2x2ERPBinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERPBinaryModeNo mandatory
Number of the binary channel.
Integer32 .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3 · 1 row entry · 22 columns
Table of properties of the binary mode.
wtWebioEA2x2ERPBinaryEntry entry .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERPBinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.1
wtWebioEA2x2ERPBinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.2
wtWebioEA2x2ERPBinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.3
wtWebioEA2x2ERPBinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.4
wtWebioEA2x2ERPBinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.5
wtWebioEA2x2ERPBinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.6
wtWebioEA2x2ERPBinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.7
wtWebioEA2x2ERPBinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.8
wtWebioEA2x2ERPBinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.9
wtWebioEA2x2ERPBinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 1-4
.1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.10
wtWebioEA2x2ERPBinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.11
wtWebioEA2x2ERPBinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.12
wtWebioEA2x2ERPBinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.13
wtWebioEA2x2ERPBinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.14
wtWebioEA2x2ERPBinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.15
wtWebioEA2x2ERPBinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.16
wtWebioEA2x2ERPBinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.17
wtWebioEA2x2ERPBinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.18
wtWebioEA2x2ERPBinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32 .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.19
wtWebioEA2x2ERPBinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.20
wtWebioEA2x2ERPBinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.21
wtWebioEA2x2ERPBinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w .1.3.6.1.4.1.5040.1.2.25.3.1.3.6.3.1.22
.1.3.6.1.4.1.5040.1.2.25.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebioEA2x2ERPOutputModeEntry entry .1.3.6.1.4.1.5040.1.2.25.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERPOutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corres…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.25.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioEA2x2ERPAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.25.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERPAlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.25.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.25.3.1.5.3 · 1 row entry · 32 columns
List of settings depending on the alarm number.
wtWebioEA2x2ERPAlarmEntry entry .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERPAlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.1
wtWebioEA2x2ERPAlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.2
wtWebioEA2x2ERPAlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.3
wtWebioEA2x2ERPAlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebioEA2x2ERPAlarmInputTrigger are not …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.4
wtWebioEA2x2ERPAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.5
wtWebioEA2x2ERPAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4: TCP Client e…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.6
wtWebioEA2x2ERPAlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.7
wtWebioEA2x2ERPAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.8
wtWebioEA2x2ERPAlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.9
wtWebioEA2x2ERPAlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.10
wtWebioEA2x2ERPAlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.11
wtWebioEA2x2ERPAlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.12
wtWebioEA2x2ERPAlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.13
wtWebioEA2x2ERPAlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.14
wtWebioEA2x2ERPAlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.15
wtWebioEA2x2ERPAlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.16
wtWebioEA2x2ERPAlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.17
wtWebioEA2x2ERPAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.18
wtWebioEA2x2ERPAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.19
wtWebioEA2x2ERPAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.20
wtWebioEA2x2ERPAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.21
wtWebioEA2x2ERPAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.22
wtWebioEA2x2ERPAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.23
wtWebioEA2x2ERPAlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.24
wtWebioEA2x2ERPAlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.25
wtWebioEA2x2ERPAlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.26
wtWebioEA2x2ERPAlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.27
wtWebioEA2x2ERPAlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.28
wtWebioEA2x2ERPAlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.29
wtWebioEA2x2ERPAlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.30
wtWebioEA2x2ERPAlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.31
wtWebioEA2x2ERPAlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.1.5.3.1.32
.1.3.6.1.4.1.5040.1.2.25.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebioEA2x2ERPInputPortEntry entry .1.3.6.1.4.1.5040.1.2.25.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERPPortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.2.1.1.1
wtWebioEA2x2ERPPortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.2.1.1.2
wtWebioEA2x2ERPPortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.2.1.1.3
wtWebioEA2x2ERPPortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.25.3.2.1.1.4
wtWebioEA2x2ERPPortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.2.1.1.5
wtWebioEA2x2ERPPortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.25.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.25.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebioEA2x2ERPOutputPortEntry entry .1.3.6.1.4.1.5040.1.2.25.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERPPortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.2.2.1.1
wtWebioEA2x2ERPPortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.2.2.1.2
wtWebioEA2x2ERPPortOutputGroupMode mandatory
It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be set all together in the same way. This v…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.25.3.2.2.1.3
wtWebioEA2x2ERPPortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.25.3.2.2.1.4
wtWebioEA2x2ERPPortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (w…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.2.2.1.5
wtWebioEA2x2ERPPortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 0-1 : inputs 0-1
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.2.2.1.6
wtWebioEA2x2ERPPortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.2.2.1.7
wtWebioEA2x2ERPPortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enable
Bit 1-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.2.2.1.8
wtWebioEA2x2ERPPortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Constraints:
range: 1-1
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.25.3.2.2.1.9
wtWebioEA2x2ERPPortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebioEA2x2ERPPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused
O…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.25.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.26.1.3 · 1 row entry · 3 columns
List of input indices.
wtWebioEA12x6RelERPInputEntry entry .1.3.6.1.4.1.5040.1.2.26.1.3.1
Number of the inputs.
Indexes
wtWebioEA2x2-24VBinaryModeNo
Column Syntax OID
wtWebioEA12x6RelERPInputNo mandatory
Index numbers of the inputs.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.5040.1.2.26.1.3.1.1
wtWebioEA12x6RelERPInputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.26.1.3.1.2
wtWebioEA12x6RelERPInputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.26.1.3.1.3
.1.3.6.1.4.1.5040.1.2.26.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebioEA12x6RelERPOutputEntry entry .1.3.6.1.4.1.5040.1.2.26.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelERPOutputNo mandatory
Output number.
Integer32
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.26.1.5.1.1
wtWebioEA12x6RelERPOutputState mandatory
Setting and reading of the states of the outputs, 0-OFF, 1-ON.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.26.1.5.1.2
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebioEA12x6RelERPBinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.26.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelERPBinaryModeNo mandatory
Number of the binary channel.
Integer32 .1.3.6.1.4.1.5040.1.2.26.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3 · 1 row entry · 22 columns
Table of properties of the binary mode.
wtWebioEA12x6RelERPBinaryEntry entry .1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelERPBinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.1
wtWebioEA12x6RelERPBinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.2
wtWebioEA12x6RelERPBinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.3
wtWebioEA12x6RelERPBinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.4
wtWebioEA12x6RelERPBinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.5
wtWebioEA12x6RelERPBinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.6
wtWebioEA12x6RelERPBinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.7
wtWebioEA12x6RelERPBinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.8
wtWebioEA12x6RelERPBinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.9
wtWebioEA12x6RelERPBinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.10
wtWebioEA12x6RelERPBinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.11
wtWebioEA12x6RelERPBinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.12
wtWebioEA12x6RelERPBinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.13
wtWebioEA12x6RelERPBinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.14
wtWebioEA12x6RelERPBinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.15
wtWebioEA12x6RelERPBinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.16
wtWebioEA12x6RelERPBinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.17
wtWebioEA12x6RelERPBinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.18
wtWebioEA12x6RelERPBinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.19
wtWebioEA12x6RelERPBinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.20
wtWebioEA12x6RelERPBinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w .1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.21
wtWebioEA12x6RelERPBinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.26.3.1.3.6.3.1.22
.1.3.6.1.4.1.5040.1.2.26.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebioEA12x6RelERPOutputModeEntry entry .1.3.6.1.4.1.5040.1.2.26.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelERPOutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an output.
Bi…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.26.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioEA12x6RelERPAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.26.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelERPAlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.26.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.26.3.1.5.3 · 1 row entry · 32 columns
List of settings depending on the alarm number.
wtWebioEA12x6RelERPAlarmEntry entry .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelERPAlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.1
wtWebioEA12x6RelERPAlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.2
wtWebioEA12x6RelERPAlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.3
wtWebioEA12x6RelERPAlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebioEA12x6RelERPAlarmInputTrigger are …
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.4
wtWebioEA12x6RelERPAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.5
wtWebioEA12x6RelERPAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4: TCP Client e…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.6
wtWebioEA12x6RelERPAlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.7
wtWebioEA12x6RelERPAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.8
wtWebioEA12x6RelERPAlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.9
wtWebioEA12x6RelERPAlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.10
wtWebioEA12x6RelERPAlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.11
wtWebioEA12x6RelERPAlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.12
wtWebioEA12x6RelERPAlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.13
wtWebioEA12x6RelERPAlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.14
wtWebioEA12x6RelERPAlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.15
wtWebioEA12x6RelERPAlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.16
wtWebioEA12x6RelERPAlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.17
wtWebioEA12x6RelERPAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.18
wtWebioEA12x6RelERPAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.19
wtWebioEA12x6RelERPAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.20
wtWebioEA12x6RelERPAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.21
wtWebioEA12x6RelERPAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.22
wtWebioEA12x6RelERPAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.23
wtWebioEA12x6RelERPAlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.24
wtWebioEA12x6RelERPAlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.25
wtWebioEA12x6RelERPAlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.26
wtWebioEA12x6RelERPAlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.27
wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.28
wtWebioEA12x6RelERPAlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.29
wtWebioEA12x6RelERPAlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.30
wtWebioEA12x6RelERPAlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.31
wtWebioEA12x6RelERPAlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.1.5.3.1.32
.1.3.6.1.4.1.5040.1.2.26.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebioEA12x6RelERPInputPortEntry entry .1.3.6.1.4.1.5040.1.2.26.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelERPPortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.2.1.1.1
wtWebioEA12x6RelERPPortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.2.1.1.2
wtWebioEA12x6RelERPPortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.2.1.1.3
wtWebioEA12x6RelERPPortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.26.3.2.1.1.4
wtWebioEA12x6RelERPPortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.26.3.2.1.1.5
wtWebioEA12x6RelERPPortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.26.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.26.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebioEA12x6RelERPOutputPortEntry entry .1.3.6.1.4.1.5040.1.2.26.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA12x6RelERPPortOutputName mandatory
Name of the output.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.26.3.2.2.1.1
wtWebioEA12x6RelERPPortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.2.2.1.2
wtWebioEA12x6RelERPPortOutputGroupMode mandatory
Unused in this device 57634
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.2.2.1.3
wtWebioEA12x6RelERPPortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.26.3.2.2.1.4
wtWebioEA12x6RelERPPortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (w…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.26.3.2.2.1.5
wtWebioEA12x6RelERPPortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: Bit 0-3 : inputs 8-11
Bit 4-7 : unused
OCTET 4:
Bit 0-7 : inputs 0-7
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.2.2.1.6
wtWebioEA12x6RelERPPortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.2.2.1.7
wtWebioEA12x6RelERPPortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enable
Bit 1-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.26.3.2.2.1.8
wtWebioEA12x6RelERPPortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.26.3.2.2.1.9
wtWebioEA12x6RelERPPortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebioEA12x6RelERPPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unus…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.26.3.2.2.1.10

wtIpWatcherInputTable

table mandatory
.1.3.6.1.4.1.5040.1.2.27.1.3 · 1 row entry · 4 columns
List of input indices.
wtIpWatcherInputEntry entry .1.3.6.1.4.1.5040.1.2.27.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcherInputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.27.1.3.1.1
wtIpWatcherInputCounter mandatory
Value of the input counter.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.5040.1.2.27.1.3.1.2
wtIpWatcherInputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.1.3.1.3
wtIpWatcherInputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.1.3.1.4

wtIpWatcherOutputTable

table mandatory
.1.3.6.1.4.1.5040.1.2.27.1.5 · 1 row entry · 2 columns
List of output indices.
wtIpWatcherOutputEntry entry .1.3.6.1.4.1.5040.1.2.27.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcherOutputNo mandatory
Output number.
Integer32
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.27.1.5.1.1
wtIpWatcherOutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.1.5.1.2
.1.3.6.1.4.1.5040.1.2.27.1.8 · 1 row entry · 2 columns
List of alarm indices..
wtIpWatcherAlarmOutputEntry entry .1.3.6.1.4.1.5040.1.2.27.1.8.1
Index reference.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcherAlarmOutputState mandatory
State of the alarm, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.1.8.1.1
wtIpWatcherAlarmTriggerState mandatory
State of the trigger condition, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.1.8.1.2
.1.3.6.1.4.1.5040.1.2.27.3.1.3.11.2 · 1 row entry · 1 columns
Table of inices.
wtIpWatcherIpListIfEntry entry .1.3.6.1.4.1.5040.1.2.27.3.1.3.11.2.1
Table entry.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcherIpListNo mandatory
List number of this entry.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.27.3.1.3.11.2.1.1

wtIpWatcherIpListTable

table mandatory
.1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3 · 1 row entry · 5 columns
List of ip addresses.
wtIpWatcherIpListEntry entry .1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1
List entry.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcherIpListName mandatory
Name or IP address.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1.1
wtIpWatcherIpListPort mandatory
Port number, zero in the case of broadcast or Ping.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1.2
wtIpWatcherIpListService mandatory
Binary coded scan mode, only one mode can be selected at a particular time:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Ping enable
Bit 1-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1.3
wtIpWatcherIpListEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: enabled in Alarm 1
Bit 1: enabled in Alarm 2
Bit 2: enabled in Alarm 3
Bit 3: enabled in Alarm 4
Bit 4-7: unused
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1.4
wtIpWatcherIpListAlias mandatory
Alias Name
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.27.3.1.3.11.3.1.5
.1.3.6.1.4.1.5040.1.2.27.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtIpWatcherAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.27.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcherAlarmNo mandatory
Numbers of the alarms.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.27.3.1.5.2.1.1

wtIpWatcherAlarmTable

table mandatory
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3 · 1 row entry · 49 columns
List of settings depending on the alarm number.
wtIpWatcherAlarmEntry entry .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcherAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.5
wtIpWatcherAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4: TCP Client e…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.6
wtIpWatcherAlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.7
wtIpWatcherAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.8
wtIpWatcherAlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w
Constraints:
range: 1-4
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.9
wtIpWatcherAlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.10
wtIpWatcherAlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.11
wtIpWatcherAlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.12
wtIpWatcherAlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.13
wtIpWatcherAlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.14
wtIpWatcherAlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.15
wtIpWatcherAlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.16
wtIpWatcherAlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.17
wtIpWatcherAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.18
wtIpWatcherAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.19
wtIpWatcherAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.20
wtIpWatcherAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.21
wtIpWatcherAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.22
wtIpWatcherAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.23
wtIpWatcherAlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.24
wtIpWatcherAlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.25
wtIpWatcherAlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.26
wtIpWatcherAlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.27
wtIpWatcherAlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.28
wtIpWatcherAlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.29
wtIpWatcherAlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.30
wtIpWatcherAlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.31
wtIpWatcherAlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.32
wtIpWatcherAlarmName mandatory
Name of the alarm.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.33
wtIpWatcherAlarmGlobalEnable mandatory
Binary coded alarm activation:
Die OCTETS werden bitweise interpretiert.
Bit 0 entspricht dem LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Alarm enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.34
wtIpWatcherAlarmCounterClear mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : Counter clear on Alarm acknowledge
Bit 0…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.35
wtIpWatcherAlarmAckEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : Software acknowledge enable
Bit 0 : Hard…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.36
wtIpWatcherAlarmAckPort mandatory
Number of the input, which clears the alarm (1-6).
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.37
wtIpWatcherAlarmSetPort mandatory
Number of the output, which will be set by this alarm (1-6).
The configuration of pulse mode and polarity defined in the port output section is used.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.38
wtIpWatcherAlarmMailTrgClearSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.39
wtIpWatcherAlarmMailTrgClearText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.40
wtIpWatcherAlarmSnmpTrapTrgClearText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.41
wtIpWatcherAlarmUdpTrgClearText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.42
wtIpWatcherAlarmTcpTrgClearText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.43
wtIpWatcherAlarmSyslogTrgClearText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.44
wtIpWatcherAlarmFtpTrgClearText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.45
wtIpWatcherAlarmMailTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.46
wtIpWatcherAlarmSnmpTrapTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.47
wtIpWatcherAlarmUdpTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.48
wtIpWatcherAlarmTcpTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.49
wtIpWatcherAlarmSyslogTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.50
wtIpWatcherAlarmFtpTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.51
wtIpWatcherAlarmTriggerCount mandatory
Alarm will be send if the trigger condition occours TriggerCount times.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.52
wtIpWatcherAlarmPollingRate mandatory
Time in seconds.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.3.1.5.3.1.53
.1.3.6.1.4.1.5040.1.2.27.3.2.1 · 1 row entry · 3 columns
List of settings depending on the input number.
wtIpWatcherInputPortEntry entry .1.3.6.1.4.1.5040.1.2.27.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcherPortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.2.1.1.1
wtIpWatcherPortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.2.1.1.2
wtIpWatcherPortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.3.2.1.1.4
.1.3.6.1.4.1.5040.1.2.27.3.2.2 · 1 row entry · 4 columns
List of settings depending on the output number.
wtIpWatcherOutputPortEntry entry .1.3.6.1.4.1.5040.1.2.27.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcherPortOutputName mandatory
Name of the output.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.27.3.2.2.1.1
wtIpWatcherPortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.2.2.1.2
wtIpWatcherPortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.27.3.2.2.1.9
wtIpWatcherPortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtIpWatcherPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused
OCTET…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.27.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.30.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebioEA2x2-24VInputEntry entry .1.3.6.1.4.1.5040.1.2.30.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2-24VInputNo mandatory
Index numbers of the inputs.
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.30.1.3.1.1
wtWebioEA2x2-24VInputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.30.1.3.1.2
wtWebioEA2x2-24VInputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.30.1.3.1.3
wtWebioEA2x2-24VInputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.30.1.3.1.4
.1.3.6.1.4.1.5040.1.2.30.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebioEA2x2-24VOutputEntry entry .1.3.6.1.4.1.5040.1.2.30.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2-24VOutputNo mandatory
Output number.
Integer32 .1.3.6.1.4.1.5040.1.2.30.1.5.1.1
wtWebioEA2x2-24VOutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.30.1.5.1.2
.1.3.6.1.4.1.5040.1.2.30.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebioEA2x2-24VBinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2-24VBinaryModeNo mandatory
Number of the binary channel.
Integer32 .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3 · 1 row entry · 22 columns
Table of properties of the binary mode.
wtWebioEA2x2-24VBinaryEntry entry .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1
Binary properties.
Indexes
wtIpWatcher-24VIpListNo
Column Syntax OID
wtWebioEA2x2-24VBinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w
Constraints:
range: 1-999
.1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.1
wtWebioEA2x2-24VBinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.2
wtWebioEA2x2-24VBinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.3
wtWebioEA2x2-24VBinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.4
wtWebioEA2x2-24VBinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.5
wtWebioEA2x2-24VBinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.6
wtWebioEA2x2-24VBinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.7
wtWebioEA2x2-24VBinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.8
wtWebioEA2x2-24VBinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.9
wtWebioEA2x2-24VBinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.10
wtWebioEA2x2-24VBinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w
Constraints:
range: 1-4
.1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.11
wtWebioEA2x2-24VBinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.12
wtWebioEA2x2-24VBinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.13
wtWebioEA2x2-24VBinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.14
wtWebioEA2x2-24VBinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.15
wtWebioEA2x2-24VBinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.16
wtWebioEA2x2-24VBinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.17
wtWebioEA2x2-24VBinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.18
wtWebioEA2x2-24VBinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32 .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.19
wtWebioEA2x2-24VBinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.20
wtWebioEA2x2-24VBinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w .1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.21
wtWebioEA2x2-24VBinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.30.3.1.3.6.3.1.22
.1.3.6.1.4.1.5040.1.2.30.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebioEA2x2-24VOutputModeEntry entry .1.3.6.1.4.1.5040.1.2.30.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2-24VOutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corres…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.30.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.30.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioEA2x2-24VAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.30.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2-24VAlarmNo mandatory
Numbers of the alarms.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.30.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.30.3.1.5.3 · 1 row entry · 32 columns
List of settings depending on the alarm number.
wtWebioEA2x2-24VAlarmEntry entry .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2-24VAlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.1
wtWebioEA2x2-24VAlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.2
wtWebioEA2x2-24VAlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.3
wtWebioEA2x2-24VAlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebioEA2x2-24VAlarmInputTrigger are not…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.4
wtWebioEA2x2-24VAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.5
wtWebioEA2x2-24VAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4: TCP Client e…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.6
wtWebioEA2x2-24VAlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.7
wtWebioEA2x2-24VAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.8
wtWebioEA2x2-24VAlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.9
wtWebioEA2x2-24VAlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.10
wtWebioEA2x2-24VAlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.11
wtWebioEA2x2-24VAlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.12
wtWebioEA2x2-24VAlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.13
wtWebioEA2x2-24VAlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.14
wtWebioEA2x2-24VAlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.15
wtWebioEA2x2-24VAlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.16
wtWebioEA2x2-24VAlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.17
wtWebioEA2x2-24VAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.18
wtWebioEA2x2-24VAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.19
wtWebioEA2x2-24VAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.20
wtWebioEA2x2-24VAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.21
wtWebioEA2x2-24VAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.22
wtWebioEA2x2-24VAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.23
wtWebioEA2x2-24VAlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.24
wtWebioEA2x2-24VAlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.25
wtWebioEA2x2-24VAlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.26
wtWebioEA2x2-24VAlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.27
wtWebioEA2x2-24VAlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.28
wtWebioEA2x2-24VAlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.29
wtWebioEA2x2-24VAlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.30
wtWebioEA2x2-24VAlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.31
wtWebioEA2x2-24VAlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.1.5.3.1.32
.1.3.6.1.4.1.5040.1.2.30.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebioEA2x2-24VInputPortEntry entry .1.3.6.1.4.1.5040.1.2.30.3.2.1.1
Input parameter for the individual inputs.
Indexes
wtIpWatcher-24VInputNo
Column Syntax OID
wtWebioEA2x2-24VPortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.2.1.1.1
wtWebioEA2x2-24VPortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.2.1.1.2
wtWebioEA2x2-24VPortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.2.1.1.3
wtWebioEA2x2-24VPortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.30.3.2.1.1.4
wtWebioEA2x2-24VPortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.2.1.1.5
wtWebioEA2x2-24VPortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.30.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.30.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebioEA2x2-24VOutputPortEntry entry .1.3.6.1.4.1.5040.1.2.30.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2-24VPortOutputName mandatory
Name of the output.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.30.3.2.2.1.1
wtWebioEA2x2-24VPortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.2.2.1.2
wtWebioEA2x2-24VPortOutputGroupMode mandatory
It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be set all together in the same way. This v…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.2.2.1.3
wtWebioEA2x2-24VPortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.30.3.2.2.1.4
wtWebioEA2x2-24VPortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (w…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.2.2.1.5
wtWebioEA2x2-24VPortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 0-1 : inputs 0-1
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.2.2.1.6
wtWebioEA2x2-24VPortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.2.2.1.7
wtWebioEA2x2-24VPortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enable
Bit 1-7 : unused
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.30.3.2.2.1.8
wtWebioEA2x2-24VPortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.30.3.2.2.1.9
wtWebioEA2x2-24VPortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebioEA2x2-24VPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.30.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.31.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebioEA2x2ERP-24VInputEntry entry .1.3.6.1.4.1.5040.1.2.31.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERP-24VInputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.31.1.3.1.1
wtWebioEA2x2ERP-24VInputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.31.1.3.1.2
wtWebioEA2x2ERP-24VInputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.31.1.3.1.3
wtWebioEA2x2ERP-24VInputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Constraints:
range: 1-2
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.31.1.3.1.4
.1.3.6.1.4.1.5040.1.2.31.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebioEA2x2ERP-24VOutputEntry entry .1.3.6.1.4.1.5040.1.2.31.1.5.1
Number of the outputs.
Indexes
wtTrapReceiver2x2ButtonNo
Column Syntax OID
wtWebioEA2x2ERP-24VOutputNo mandatory
Output number.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.5040.1.2.31.1.5.1.1
wtWebioEA2x2ERP-24VOutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.31.1.5.1.2
.1.3.6.1.4.1.5040.1.2.31.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebioEA2x2ERP-24VBinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERP-24VBinaryModeNo mandatory
Number of the binary channel.
Integer32 .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3 · 1 row entry · 22 columns
Table of properties of the binary mode.
wtWebioEA2x2ERP-24VBinaryEntry entry .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERP-24VBinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.1
wtWebioEA2x2ERP-24VBinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.2
wtWebioEA2x2ERP-24VBinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.3
wtWebioEA2x2ERP-24VBinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.4
wtWebioEA2x2ERP-24VBinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.5
wtWebioEA2x2ERP-24VBinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.6
wtWebioEA2x2ERP-24VBinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.7
wtWebioEA2x2ERP-24VBinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.8
wtWebioEA2x2ERP-24VBinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Constraints:
range: 1-65535
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.9
wtWebioEA2x2ERP-24VBinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.10
wtWebioEA2x2ERP-24VBinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.11
wtWebioEA2x2ERP-24VBinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.12
wtWebioEA2x2ERP-24VBinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.13
wtWebioEA2x2ERP-24VBinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.14
wtWebioEA2x2ERP-24VBinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.15
wtWebioEA2x2ERP-24VBinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.16
wtWebioEA2x2ERP-24VBinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.17
wtWebioEA2x2ERP-24VBinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.18
wtWebioEA2x2ERP-24VBinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32 .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.19
wtWebioEA2x2ERP-24VBinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Constraints:
range: 4-4
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.20
wtWebioEA2x2ERP-24VBinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.21
wtWebioEA2x2ERP-24VBinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w .1.3.6.1.4.1.5040.1.2.31.3.1.3.6.3.1.22
.1.3.6.1.4.1.5040.1.2.31.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebioEA2x2ERP-24VOutputModeEntry entry .1.3.6.1.4.1.5040.1.2.31.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERP-24VOutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corres…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.31.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.31.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebioEA2x2ERP-24VAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.31.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERP-24VAlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.31.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.31.3.1.5.3 · 1 row entry · 32 columns
List of settings depending on the alarm number.
wtWebioEA2x2ERP-24VAlarmEntry entry .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERP-24VAlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.1
wtWebioEA2x2ERP-24VAlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.2
wtWebioEA2x2ERP-24VAlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.3
wtWebioEA2x2ERP-24VAlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebioEA2x2ERP-24VAlarmInputTrigger are …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.4
wtWebioEA2x2ERP-24VAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.5
wtWebioEA2x2ERP-24VAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4: TCP Client e…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.6
wtWebioEA2x2ERP-24VAlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.7
wtWebioEA2x2ERP-24VAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.8
wtWebioEA2x2ERP-24VAlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.9
wtWebioEA2x2ERP-24VAlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.10
wtWebioEA2x2ERP-24VAlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.11
wtWebioEA2x2ERP-24VAlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.12
wtWebioEA2x2ERP-24VAlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.13
wtWebioEA2x2ERP-24VAlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.14
wtWebioEA2x2ERP-24VAlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.15
wtWebioEA2x2ERP-24VAlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.16
wtWebioEA2x2ERP-24VAlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.17
wtWebioEA2x2ERP-24VAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.18
wtWebioEA2x2ERP-24VAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.19
wtWebioEA2x2ERP-24VAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.20
wtWebioEA2x2ERP-24VAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.21
wtWebioEA2x2ERP-24VAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.22
wtWebioEA2x2ERP-24VAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.23
wtWebioEA2x2ERP-24VAlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.24
wtWebioEA2x2ERP-24VAlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.25
wtWebioEA2x2ERP-24VAlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.26
wtWebioEA2x2ERP-24VAlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.27
wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.28
wtWebioEA2x2ERP-24VAlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.29
wtWebioEA2x2ERP-24VAlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.30
wtWebioEA2x2ERP-24VAlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.31
wtWebioEA2x2ERP-24VAlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.31.3.1.5.3.1.32
.1.3.6.1.4.1.5040.1.2.31.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebioEA2x2ERP-24VInputPortEntry entry .1.3.6.1.4.1.5040.1.2.31.3.2.1.1
Input parameter for the individual inputs.
Indexes
wtWebio577xxEA1x1InputNo
Column Syntax OID
wtWebioEA2x2ERP-24VPortInputName mandatory
Name of the input.
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.31.3.2.1.1.1
wtWebioEA2x2ERP-24VPortInputText mandatory
Description of the input.
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.31.3.2.1.1.2
wtWebioEA2x2ERP-24VPortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.2.1.1.3
wtWebioEA2x2ERP-24VPortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.31.3.2.1.1.4
wtWebioEA2x2ERP-24VPortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.2.1.1.5
wtWebioEA2x2ERP-24VPortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.31.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.31.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebioEA2x2ERP-24VOutputPortEntry entry .1.3.6.1.4.1.5040.1.2.31.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebioEA2x2ERP-24VPortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.1
wtWebioEA2x2ERP-24VPortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.2
wtWebioEA2x2ERP-24VPortOutputGroupMode mandatory
It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be set all together in the same way. This v…
OctetStringr/w
Constraints:
range: 1-2
.1.3.6.1.4.1.5040.1.2.31.3.2.2.1.3
wtWebioEA2x2ERP-24VPortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.4
wtWebioEA2x2ERP-24VPortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (w…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.5
wtWebioEA2x2ERP-24VPortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 0-1 : inputs 0-1
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.31.3.2.2.1.6
wtWebioEA2x2ERP-24VPortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.31.3.2.2.1.7
wtWebioEA2x2ERP-24VPortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enable
Bit 1-7 : unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.31.3.2.2.1.8
wtWebioEA2x2ERP-24VPortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.31.3.2.2.1.9
wtWebioEA2x2ERP-24VPortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebioEA2x2ERP-24VPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unus…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.31.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.32.1.3 · 1 row entry · 4 columns
List of input indices.
wtIpWatcher-24VInputEntry entry .1.3.6.1.4.1.5040.1.2.32.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcher-24VInputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.32.1.3.1.1
wtIpWatcher-24VInputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.32.1.3.1.2
wtIpWatcher-24VInputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.1.3.1.3
wtIpWatcher-24VInputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Constraints:
range: 0-65535
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.1.3.1.4
.1.3.6.1.4.1.5040.1.2.32.1.5 · 1 row entry · 2 columns
List of output indices.
wtIpWatcher-24VOutputEntry entry .1.3.6.1.4.1.5040.1.2.32.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcher-24VOutputNo mandatory
Output number.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.32.1.5.1.1
wtIpWatcher-24VOutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.1.5.1.2
.1.3.6.1.4.1.5040.1.2.32.1.8 · 1 row entry · 2 columns
List of alarm indices..
wtIpWatcher-24VAlarmOutputEntry entry .1.3.6.1.4.1.5040.1.2.32.1.8.1
Index reference.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcher-24VAlarmOutputState mandatory
State of the alarm, 0-OFF, 1-ON.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.1.8.1.1
wtIpWatcher-24VAlarmTriggerState mandatory
State of the trigger condition, 0-OFF, 1-ON.
Integer32
Constraints:
range: 1-65535
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.1.8.1.2
.1.3.6.1.4.1.5040.1.2.32.3.1.3.11.2 · 1 row entry · 1 columns
Table of inices.
wtIpWatcher-24VIpListIfEntry entry .1.3.6.1.4.1.5040.1.2.32.3.1.3.11.2.1
Table entry.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcher-24VIpListNo mandatory
List number of this entry.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.32.3.1.3.11.2.1.1
.1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3 · 1 row entry · 5 columns
List of ip addresses.
wtIpWatcher-24VIpListEntry entry .1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1
List entry.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcher-24VIpListName mandatory
Name or IP address.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1.1
wtIpWatcher-24VIpListPort mandatory
Port number, zero in the case of broadcast or Ping.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1.2
wtIpWatcher-24VIpListService mandatory
Binary coded scan mode, only one mode can be selected at a particular time:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Ping enable
Bit 1-7: unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1.3
wtIpWatcher-24VIpListEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: enabled in Alarm 1
Bit 1: enabled in Alarm 2
Bit 2: enabled in Alarm 3
Bit 3: enabled in Alarm 4
Bit 4-7: unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1.4
wtIpWatcher-24VIpListAlias mandatory
Alias Name
OctetStringr/w
Constraints:
range: 1-12
.1.3.6.1.4.1.5040.1.2.32.3.1.3.11.3.1.5
.1.3.6.1.4.1.5040.1.2.32.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtIpWatcher-24VAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.32.3.1.5.2.1
Numbers of the alarms.
Indexes
wtWebio577xxEA1x1AlarmNo
Column Syntax OID
wtIpWatcher-24VAlarmNo mandatory
Numbers of the alarms.
Integer32
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.32.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3 · 1 row entry · 49 columns
List of settings depending on the alarm number.
wtIpWatcher-24VAlarmEntry entry .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcher-24VAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.5
wtIpWatcher-24VAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4: TCP Client e…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.6
wtIpWatcher-24VAlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.7
wtIpWatcher-24VAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.8
wtIpWatcher-24VAlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.9
wtIpWatcher-24VAlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.10
wtIpWatcher-24VAlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.11
wtIpWatcher-24VAlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.12
wtIpWatcher-24VAlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.13
wtIpWatcher-24VAlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.14
wtIpWatcher-24VAlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.15
wtIpWatcher-24VAlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.16
wtIpWatcher-24VAlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.17
wtIpWatcher-24VAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.18
wtIpWatcher-24VAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.19
wtIpWatcher-24VAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.20
wtIpWatcher-24VAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.21
wtIpWatcher-24VAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.22
wtIpWatcher-24VAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.23
wtIpWatcher-24VAlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.24
wtIpWatcher-24VAlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.25
wtIpWatcher-24VAlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.26
wtIpWatcher-24VAlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.27
wtIpWatcher-24VAlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.28
wtIpWatcher-24VAlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.29
wtIpWatcher-24VAlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.30
wtIpWatcher-24VAlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.31
wtIpWatcher-24VAlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.32
wtIpWatcher-24VAlarmName mandatory
Name of the alarm.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.33
wtIpWatcher-24VAlarmGlobalEnable mandatory
Binary coded alarm activation:
Die OCTETS werden bitweise interpretiert.
Bit 0 entspricht dem LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Alarm enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.34
wtIpWatcher-24VAlarmCounterClear mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : Counter clear on Alarm acknowledge
Bit 0…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.35
wtIpWatcher-24VAlarmAckEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : Software acknowledge enable
Bit 0 : Hard…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.36
wtIpWatcher-24VAlarmAckPort mandatory
Number of the input, which clears the alarm (1-6).
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.37
wtIpWatcher-24VAlarmSetPort mandatory
Number of the output, which will be set by this alarm (1-6).
The configuration of pulse mode and polarity defined in the port output section is used.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.38
wtIpWatcher-24VAlarmMailTrgClearSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.39
wtIpWatcher-24VAlarmMailTrgClearText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.40
wtIpWatcher-24VAlarmSnmpTrapTrgClearText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.41
wtIpWatcher-24VAlarmUdpTrgClearText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.42
wtIpWatcher-24VAlarmTcpTrgClearText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.43
wtIpWatcher-24VAlarmSyslogTrgClearText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.44
wtIpWatcher-24VAlarmFtpTrgClearText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.45
wtIpWatcher-24VAlarmMailTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.46
wtIpWatcher-24VAlarmSnmpTrapTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.47
wtIpWatcher-24VAlarmUdpTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.48
wtIpWatcher-24VAlarmTcpTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.49
wtIpWatcher-24VAlarmSyslogTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.50
wtIpWatcher-24VAlarmFtpTrapTxEnable mandatory
Binary coded options:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
Bit 3 : Alarm OFF message enable
Bit 2 : Trigger…
OctetStringr/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.51
wtIpWatcher-24VAlarmTriggerCount mandatory
Alarm will be send if the trigger condition occours TriggerCount times.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.52
wtIpWatcher-24VAlarmPollingRate mandatory
Time in seconds.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.3.1.5.3.1.53
.1.3.6.1.4.1.5040.1.2.32.3.2.1 · 1 row entry · 3 columns
List of settings depending on the input number.
wtIpWatcher-24VInputPortEntry entry .1.3.6.1.4.1.5040.1.2.32.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcher-24VPortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.2.1.1.1
wtIpWatcher-24VPortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.2.1.1.2
wtIpWatcher-24VPortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.3.2.1.1.4
.1.3.6.1.4.1.5040.1.2.32.3.2.2 · 1 row entry · 4 columns
List of settings depending on the output number.
wtIpWatcher-24VOutputPortEntry entry .1.3.6.1.4.1.5040.1.2.32.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtIpWatcher-24VPortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.2.2.1.1
wtIpWatcher-24VPortOutputText mandatory
Description of the output.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.32.3.2.2.1.2
wtIpWatcher-24VPortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.32.3.2.2.1.9
wtIpWatcher-24VPortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtIpWatcher-24VPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused
O…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.32.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.33.1.3 · 1 row entry · 2 columns
List of input indices.
wtTrapReceiver2x2InputEntry entry .1.3.6.1.4.1.5040.1.2.33.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2InputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.33.1.3.1.1
wtTrapReceiver2x2InputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.33.1.3.1.4
.1.3.6.1.4.1.5040.1.2.33.1.5 · 1 row entry · 2 columns
List of output indices.
wtTrapReceiver2x2OutputEntry entry .1.3.6.1.4.1.5040.1.2.33.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2OutputNo mandatory
Output number.
Integer32
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.33.1.5.1.1
wtTrapReceiver2x2OutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.33.1.5.1.2
.1.3.6.1.4.1.5040.1.2.33.1.8 · 1 row entry · 2 columns
List of alarm indices..
wtTrapReceiver2x2ActionOutputEntry entry .1.3.6.1.4.1.5040.1.2.33.1.8.1
Index reference.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2ActionOutputState mandatory
State of the alarm, 0-OFF, 1-ON.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.33.1.8.1.1
wtTrapReceiver2x2ActionTriggerState mandatory
State of the trigger condition, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.33.1.8.1.2
.1.3.6.1.4.1.5040.1.2.33.1.9 · 1 row entry · 1 columns
List of system timer.
wtTrapReceiver2x2SystemTimerEntry entry .1.3.6.1.4.1.5040.1.2.33.1.9.1
Number of the system timer.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2SystemTimerNo mandatory
Index number of the system timer.
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.33.1.9.1.1
.1.3.6.1.4.1.5040.1.2.33.1.10 · 1 row entry · 1 columns
List of buttons.
wtTrapReceiver2x2ButtonEntry entry .1.3.6.1.4.1.5040.1.2.33.1.10.1
Number of the button.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2ButtonNo mandatory
Index numder of the button.
Integer32 .1.3.6.1.4.1.5040.1.2.33.1.10.1.1
.1.3.6.1.4.1.5040.1.2.33.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtTrapReceiver2x2ActionIfEntry entry .1.3.6.1.4.1.5040.1.2.33.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2ActionNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.33.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3 · 1 row entry · 27 columns
List of settings depending on the alarm number.
wtTrapReceiver2x2ActionEntry entry .1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1
Action parameters of the individual alarms.
Indexes
wtWebio577xxEA12x12BinaryModeNo
Column Syntax OID
wtTrapReceiver2x2ActionInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The four OCTETS contain the mask whic…
OctetStringr/w
Constraints:
range: 1-2
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.1
wtTrapReceiver2x2ActionInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.5
wtTrapReceiver2x2ActionEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: UDP enable
Bit 3: Send inputs to pending TCP connections
Bit 4: TCP Client e…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.6
wtTrapReceiver2x2ActionMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.7
wtTrapReceiver2x2ActionMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.8
wtTrapReceiver2x2ActionMailText mandatory
Action mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.9
wtTrapReceiver2x2ActionSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.10
wtTrapReceiver2x2ActionSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.11
wtTrapReceiver2x2ActionUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.12
wtTrapReceiver2x2ActionUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.13
wtTrapReceiver2x2ActionUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.14
wtTrapReceiver2x2ActionTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.15
wtTrapReceiver2x2ActionTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.16
wtTrapReceiver2x2ActionTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.17
wtTrapReceiver2x2ActionSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.18
wtTrapReceiver2x2ActionSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.19
wtTrapReceiver2x2ActionSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.20
wtTrapReceiver2x2ActionFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.21
wtTrapReceiver2x2ActionFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.22
wtTrapReceiver2x2ActionFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.23
wtTrapReceiver2x2ActionFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.24
wtTrapReceiver2x2ActionTimerCron mandatory
This entry contains 10 space or tab seperated text fields defining a time window for sending
time triggered messages. 2 CRON time for start time and stop time are defined as follows:
Start time:
field
1: Minutes Range 0…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.25
wtTrapReceiver2x2ActionName mandatory
Name of the alarm.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.33
wtTrapReceiver2x2ActionGlobalEnable mandatory
Binary coded alarm activation:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bi…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.34
wtTrapReceiver2x2ActionSystemTimerTrigger mandatory
Binary coded system timer activation:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.

OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OC…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.55
wtTrapReceiver2x2ActionSystemButtonTrigger mandatory
Binary coded button activation:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.

OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.56
wtTrapReceiver2x2ActionOutputAction mandatory
This variable allows setting of individual output.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mask which determines…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.5.3.1.57
.1.3.6.1.4.1.5040.1.2.33.3.1.6.1.2 · 1 row entry · 1 columns
Table of inices.
wtTrapReceiver2x2WatchListIfEntry entry .1.3.6.1.4.1.5040.1.2.33.3.1.6.1.2.1
Table entry.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2WatchListNo mandatory
List number of this entry.
Integer32 .1.3.6.1.4.1.5040.1.2.33.3.1.6.1.2.1.1
.1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3 · 1 row entry · 9 columns
List of ip addresses.
wtTrapReceiver2x2WatchListEntry entry .1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1
List entry.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2WatchListName mandatory
Name or IP address.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.1
wtTrapReceiver2x2WatchListPort mandatory
Port number, zero in the case of broadcast or Ping.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.2
wtTrapReceiver2x2WatchListService mandatory
Binary coded scan mode, only one mode can be selected at a particular time:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: unused
Bit 1: unused
Bit 2: SNMP Trap reveive enable
Bit 3: Syslog rece…
OctetStringr/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.3
wtTrapReceiver2x2WatchListEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: enabled in Report 9
Bit 1: enabled in Report 10
Bit 2: enabled in Report 11
Bit 3: enabled in Report 12
Bit 4-7: unused
Octet 4:
Bit 0…
OctetStringr/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.4
wtTrapReceiver2x2WatchListAlias mandatory
Alias Name
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.5
wtTrapReceiver2x2WatchListTrapNo mandatory
SNMP Trap No: this filter is only active, if SNMP Trap reveive enable in
wtTrapReceiver2x2WatchListService is set.
wtTrapReceiver2x2WatchListTrapNo-ColdStart(0),
wtTrapReceiver2x2WatchListTrapNo-WarmStart(1),
wtTrapRece…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.6
wtTrapReceiver2x2WatchListSpecificNo mandatory
SNMP Specific No: this filter is only active, if SNMP Trap reveive enable in
wtTrapReceiver2x2WatchListService is set.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.7
wtTrapReceiver2x2WatchListFacility mandatory
Syslog message level Facility: this filter is only active, if Syslog receive enable in
wtTrapReceiver2x2WatchListService is set.
wtTrapReceiver2x2WatchListFacility-Emergency(0),
wtTrapReceiver2x2WatchListFacility-Alert(…
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.8
wtTrapReceiver2x2WatchListSeverity mandatory
Syslog message level Severity: this filter is only active, if Syslog receive enable in
wtTrapReceiver2x2WatchListService is set.
wtTrapReceiver2x2WatchListSeverity-kernel-messages(0),
wtTrapReceiver2x2WatchListSeverity-…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.33.3.1.6.1.3.1.9
.1.3.6.1.4.1.5040.1.2.33.3.1.6.2.1 · 1 row entry · 3 columns
List of settings depending on the SystemTimer number.
wtTrapReceiver2x2SystemTimerPortEntry entry .1.3.6.1.4.1.5040.1.2.33.3.1.6.2.1.1
SystemTimer parameter for the individual SystemTimer.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2PortSystemTimerEnable mandatory
Binary coded SystemTimer enable:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
OCTET 1: ungenutzt
OCTET 2: ungenutzt
OCTET 3: ungenutzt
OCTET 4, Bit 1-7: …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.6.2.1.1.1
wtTrapReceiver2x2PortSystemTimerName mandatory
Name of the SystemTimer.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.6.2.1.1.2
wtTrapReceiver2x2PortSystemTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.6.2.1.1.3
.1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1 · 1 row entry · 4 columns
List of settings depending on the button number.
wtTrapReceiver2x2ButtonPortEntry entry .1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1.1
Button parameter for the individual buttons.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2PortButtonEnable mandatory
Binary coded button enable:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
OCTET 1: ungenutzt
OCTET 2: ungenutzt
OCTET 3: ungenutzt
OCTET 4, Bit 1-7: ungen…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1.1.1
wtTrapReceiver2x2PortButtonName mandatory
Name of the button.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1.1.2
wtTrapReceiver2x2PortButtonText mandatory
Description of the button.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1.1.3
wtTrapReceiver2x2PortButtonAccess mandatory
Binary coded button access level:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 3-7: unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.6.3.1.1.4
.1.3.6.1.4.1.5040.1.2.33.3.1.6.4.1 · 1 row entry · 3 columns
List of settings depending on the input number.
wtTrapReceiver2x2InputPortEntry entry .1.3.6.1.4.1.5040.1.2.33.3.1.6.4.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2PortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.6.4.1.1.1
wtTrapReceiver2x2PortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.6.4.1.1.2
wtTrapReceiver2x2PortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.33.3.1.6.4.1.1.4
.1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1 · 1 row entry · 4 columns
List of settings depending on the output number.
wtTrapReceiver2x2OutputPortEntry entry .1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtTrapReceiver2x2PortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1.1.1
wtTrapReceiver2x2PortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1.1.2
wtTrapReceiver2x2PortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1.1.9
wtTrapReceiver2x2PortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtTrapReceiver2x2PortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.33.3.1.7.1.1.1.10
.1.3.6.1.4.1.5040.1.2.48.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebio577xxEA1x1InputEntry entry .1.3.6.1.4.1.5040.1.2.48.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA1x1InputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.48.1.3.1.1
wtWebio577xxEA1x1InputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.48.1.3.1.2
wtWebio577xxEA1x1InputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.48.1.3.1.3
wtWebio577xxEA1x1InputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.48.1.3.1.4
.1.3.6.1.4.1.5040.1.2.48.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebio577xxEA1x1OutputEntry entry .1.3.6.1.4.1.5040.1.2.48.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA1x1OutputNo mandatory
Output number.
Integer32 .1.3.6.1.4.1.5040.1.2.48.1.5.1.1
wtWebio577xxEA1x1OutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.48.1.5.1.2
.1.3.6.1.4.1.5040.1.2.48.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebio577xxEA1x1BinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA1x1BinaryModeNo mandatory
Number of the binary channel.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3 · 1 row entry · 23 columns
Table of properties of the binary mode.
wtWebio577xxEA1x1BinaryEntry entry .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA1x1BinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.1
wtWebio577xxEA1x1BinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.2
wtWebio577xxEA1x1BinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.3
wtWebio577xxEA1x1BinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.4
wtWebio577xxEA1x1BinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.5
wtWebio577xxEA1x1BinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.6
wtWebio577xxEA1x1BinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.7
wtWebio577xxEA1x1BinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.8
wtWebio577xxEA1x1BinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.9
wtWebio577xxEA1x1BinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.10
wtWebio577xxEA1x1BinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.11
wtWebio577xxEA1x1BinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.12
wtWebio577xxEA1x1BinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.13
wtWebio577xxEA1x1BinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.14
wtWebio577xxEA1x1BinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.15
wtWebio577xxEA1x1BinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.16
wtWebio577xxEA1x1BinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.17
wtWebio577xxEA1x1BinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.18
wtWebio577xxEA1x1BinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32 .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.19
wtWebio577xxEA1x1BinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.20
wtWebio577xxEA1x1BinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.21
wtWebio577xxEA1x1BinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.22
wtWebio577xxEA1x1BinaryTcpClientServerUserName mandatory
User Name to login at the remote server, if authentication needed.
OctetString .1.3.6.1.4.1.5040.1.2.48.3.1.3.6.3.1.23
.1.3.6.1.4.1.5040.1.2.48.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebio577xxEA1x1OutputModeEntry entry .1.3.6.1.4.1.5040.1.2.48.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA1x1OutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corres…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.48.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebio577xxEA1x1AlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.48.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA1x1AlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.48.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3 · 1 row entry · 54 columns
List of settings depending on the alarm number.
wtWebio577xxEA1x1AlarmEntry entry .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA1x1AlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.1
wtWebio577xxEA1x1AlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.2
wtWebio577xxEA1x1AlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.3
wtWebio577xxEA1x1AlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebio577xxEA1x1AlarmInputTrigger are no…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.4
wtWebio577xxEA1x1AlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.5
wtWebio577xxEA1x1AlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Bit 0: UDP enable
Bit1-7: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
Bit 3: Syslog Messages enable
Bit 4: F…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.6
wtWebio577xxEA1x1AlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.7
wtWebio577xxEA1x1AlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.8
wtWebio577xxEA1x1AlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.9
wtWebio577xxEA1x1AlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.10
wtWebio577xxEA1x1AlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.11
wtWebio577xxEA1x1AlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w
Constraints:
range: 1-2
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.12
wtWebio577xxEA1x1AlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.13
wtWebio577xxEA1x1AlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.14
wtWebio577xxEA1x1AlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.15
wtWebio577xxEA1x1AlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.16
wtWebio577xxEA1x1AlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.17
wtWebio577xxEA1x1AlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.18
wtWebio577xxEA1x1AlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.19
wtWebio577xxEA1x1AlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.20
wtWebio577xxEA1x1AlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.21
wtWebio577xxEA1x1AlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.22
wtWebio577xxEA1x1AlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.23
wtWebio577xxEA1x1AlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.24
wtWebio577xxEA1x1AlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.25
wtWebio577xxEA1x1AlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.26
wtWebio577xxEA1x1AlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.27
wtWebio577xxEA1x1AlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.28
wtWebio577xxEA1x1AlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.29
wtWebio577xxEA1x1AlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.30
wtWebio577xxEA1x1AlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.31
wtWebio577xxEA1x1AlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.32
wtWebio577xxEA1x1AlarmGlobalEnable mandatory
Binary coded alarm activation:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Alarm enable
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.34
wtWebio577xxEA1x1AlarmCombinationLogic mandatory
Binary coded alarm activation::
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : OR
Bit 0 : AND
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.58
wtWebio577xxEA1x1AlarmTrgMqttTopic mandatory
MQTT subscribe topic.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.59
wtWebio577xxEA1x1AlarmTrgMqttTopicText mandatory
Receiving this text from the MQTT Broker, Alarm will be triggered.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.60
wtWebio577xxEA1x1AlarmHttpReqAuthEnable mandatory
Binary coded alarm activation:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : HHTP Request Authentication enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.61
wtWebio577xxEA1x1AlarmHttpReqAuthUser mandatory
HTTP Request: User
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.62
wtWebio577xxEA1x1AlarmHttpReqAuthPassword mandatory
HTTP Request: Password
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.63
wtWebio577xxEA1x1AlarmHttpReqSetUrl mandatory
HTTP Request: Set URL
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.64
wtWebio577xxEA1x1AlarmHttpReqClearUrl mandatory
HTTP Request: Clear URL
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.65
wtWebio577xxEA1x1AlarmHttpReqServerPort mandatory
HTTP Request: Server Port
Integer32r/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.66
wtWebio577xxEA1x1AlarmMqttTopicPath mandatory
MQTT Publish: Topic path
OctetStringr/w
Constraints:
range: 1-12
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.67
wtWebio577xxEA1x1AlarmMqttTopicSetTopic mandatory
MQTT Publish: Topic SET message
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.68
wtWebio577xxEA1x1AlarmMqttTopicClear mandatory
MQTT Publish: Topic CLEAR message
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.69
wtWebio577xxEA1x1AlarmSetOutputsOwn mandatory
This variable allows setting of individual output.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mask which determine…
OctetStringr/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.70
wtWebio577xxEA1x1AlarmSetOutputsServerIp mandatory
Set Outputs: Server IP Address
OctetStringr/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.71
wtWebio577xxEA1x1AlarmSetOutputsServerPort mandatory
Set Outputs: Server Port
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.72
wtWebio577xxEA1x1AlarmSetOutputsServerPassword mandatory
Set Outputs: Server Pasword
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.73
wtWebio577xxEA1x1AlarmSetOutputsServerOutputs mandatory
This variable allows setting of individual output.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mask which determine…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.74
wtWebio577xxEA1x1AlarmSetOutputsDest mandatory
Binary coded value:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : set …
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.75
wtWebio577xxEA1x1AlarmSnmpManagerPort mandatory
Port number of the SNMP Manager to which the Webio device should send SNMP traps.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.76
wtWebio577xxEA1x1AlarmMqttQoS mandatory
Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: QoS 0
Bit 1: QoS 1
Bit 2: QoS 2
Bit 3-7:unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.77
wtWebio577xxEA1x1AlarmMqttRetain mandatory
Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : retain enable
Bit 1-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.1.5.3.1.78
.1.3.6.1.4.1.5040.1.2.48.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebio577xxEA1x1InputPortEntry entry .1.3.6.1.4.1.5040.1.2.48.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA1x1PortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.2.1.1.1
wtWebio577xxEA1x1PortInputText mandatory
Description of the input.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.2.1.1.2
wtWebio577xxEA1x1PortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.2.1.1.3
wtWebio577xxEA1x1PortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.48.3.2.1.1.4
wtWebio577xxEA1x1PortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.48.3.2.1.1.5
wtWebio577xxEA1x1PortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.48.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.48.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebio577xxEA1x1OutputPortEntry entry .1.3.6.1.4.1.5040.1.2.48.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA1x1PortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.2.2.1.1
wtWebio577xxEA1x1PortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.2.2.1.2
wtWebio577xxEA1x1PortOutputGroupMode mandatory
It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be set all together in the same way. This v…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.2.2.1.3
wtWebio577xxEA1x1PortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.2.2.1.4
wtWebio577xxEA1x1PortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (w…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.48.3.2.2.1.5
wtWebio577xxEA1x1PortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 0-1 : inputs 0-1
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.2.2.1.6
wtWebio577xxEA1x1PortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.2.2.1.7
wtWebio577xxEA1x1PortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enable
Bit 1-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.2.2.1.8
wtWebio577xxEA1x1PortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.48.3.2.2.1.9
wtWebio577xxEA1x1PortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebio577xxEA1x1PortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.48.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.49.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebio577xxEA12x12InputEntry entry .1.3.6.1.4.1.5040.1.2.49.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x12InputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.49.1.3.1.1
wtWebio577xxEA12x12InputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.49.1.3.1.2
wtWebio577xxEA12x12InputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.49.1.3.1.3
wtWebio577xxEA12x12InputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.49.1.3.1.4
.1.3.6.1.4.1.5040.1.2.49.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebio577xxEA12x12OutputEntry entry .1.3.6.1.4.1.5040.1.2.49.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x12OutputNo mandatory
Output number.
Integer32 .1.3.6.1.4.1.5040.1.2.49.1.5.1.1
wtWebio577xxEA12x12OutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.49.1.5.1.2
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebio577xxEA12x12BinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x12BinaryModeNo mandatory
Number of the binary channel.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3 · 1 row entry · 23 columns
Table of properties of the binary mode.
wtWebio577xxEA12x12BinaryEntry entry .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x12BinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.1
wtWebio577xxEA12x12BinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.2
wtWebio577xxEA12x12BinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.3
wtWebio577xxEA12x12BinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.4
wtWebio577xxEA12x12BinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.5
wtWebio577xxEA12x12BinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.6
wtWebio577xxEA12x12BinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.7
wtWebio577xxEA12x12BinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.8
wtWebio577xxEA12x12BinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Constraints:
range: 4-4
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.9
wtWebio577xxEA12x12BinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.10
wtWebio577xxEA12x12BinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.11
wtWebio577xxEA12x12BinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.12
wtWebio577xxEA12x12BinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.13
wtWebio577xxEA12x12BinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.14
wtWebio577xxEA12x12BinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.15
wtWebio577xxEA12x12BinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.16
wtWebio577xxEA12x12BinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.17
wtWebio577xxEA12x12BinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.18
wtWebio577xxEA12x12BinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32 .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.19
wtWebio577xxEA12x12BinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.20
wtWebio577xxEA12x12BinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.21
wtWebio577xxEA12x12BinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.22
wtWebio577xxEA12x12BinaryTcpClientServerUserName mandatory
User Name to login at the remote server, if authentication needed.
OctetString .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.23
.1.3.6.1.4.1.5040.1.2.49.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebio577xxEA12x12OutputModeEntry entry .1.3.6.1.4.1.5040.1.2.49.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x12OutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corres…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.49.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebio577xxEA12x12AlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.49.3.1.5.2.1
Numbers of the alarms.
Indexes
wtWebio577xxEA2x2InputNo
Column Syntax OID
wtWebio577xxEA12x12AlarmNo mandatory
Numbers of the alarms.
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.49.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3 · 1 row entry · 54 columns
List of settings depending on the alarm number.
wtWebio577xxEA12x12AlarmEntry entry .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x12AlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.1
wtWebio577xxEA12x12AlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.2
wtWebio577xxEA12x12AlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.3
wtWebio577xxEA12x12AlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebio577xxEA12x12AlarmInputTrigger are …
OctetStringr/w
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.4
wtWebio577xxEA12x12AlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.5
wtWebio577xxEA12x12AlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Bit 0: UDP enable
Bit1-7: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
Bit 3: Syslog Messages enable
Bit 4: F…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.6
wtWebio577xxEA12x12AlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.7
wtWebio577xxEA12x12AlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w
Constraints:
range: 1-2
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.8
wtWebio577xxEA12x12AlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.9
wtWebio577xxEA12x12AlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.10
wtWebio577xxEA12x12AlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.11
wtWebio577xxEA12x12AlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.12
wtWebio577xxEA12x12AlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.13
wtWebio577xxEA12x12AlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.14
wtWebio577xxEA12x12AlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.15
wtWebio577xxEA12x12AlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.16
wtWebio577xxEA12x12AlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.17
wtWebio577xxEA12x12AlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.18
wtWebio577xxEA12x12AlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.19
wtWebio577xxEA12x12AlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.20
wtWebio577xxEA12x12AlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.21
wtWebio577xxEA12x12AlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.22
wtWebio577xxEA12x12AlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.23
wtWebio577xxEA12x12AlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.24
wtWebio577xxEA12x12AlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.25
wtWebio577xxEA12x12AlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.26
wtWebio577xxEA12x12AlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.27
wtWebio577xxEA12x12AlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.28
wtWebio577xxEA12x12AlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.29
wtWebio577xxEA12x12AlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.30
wtWebio577xxEA12x12AlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.31
wtWebio577xxEA12x12AlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.32
wtWebio577xxEA12x12AlarmGlobalEnable mandatory
Binary coded alarm activation:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Alarm enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.34
wtWebio577xxEA12x12AlarmCombinationLogic mandatory
Binary coded logic, all Input/Output-trigger will be combined:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : OR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.58
wtWebio577xxEA12x12AlarmTrgMqttTopic mandatory
MQTT subscribe topic.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.59
wtWebio577xxEA12x12AlarmTrgMqttTopicText mandatory
Receiving this text from the MQTT Broker, Alarm will be triggered.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.60
wtWebio577xxEA12x12AlarmHttpReqAuthEnable mandatory
Binary coded value:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : HHTP Request Authentication enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.61
wtWebio577xxEA12x12AlarmHttpReqAuthUser mandatory
HTTP Request: User
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.62
wtWebio577xxEA12x12AlarmHttpReqAuthPassword mandatory
HTTP Request: Password
OctetStringr/w
Constraints:
range: 1-12
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.63
wtWebio577xxEA12x12AlarmHttpReqSetUrl mandatory
HTTP Request: Set URL
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.64
wtWebio577xxEA12x12AlarmHttpReqClearUrl mandatory
HTTP Request: Clear URL
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.65
wtWebio577xxEA12x12AlarmHttpReqServerPort mandatory
HTTP Request: Server Port
Integer32r/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.66
wtWebio577xxEA12x12AlarmMqttTopicPath mandatory
MQTT Publish: Topic path
OctetStringr/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.67
wtWebio577xxEA12x12AlarmMqttTopicSetTopic mandatory
MQTT Publish: Topic SET message
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.68
wtWebio577xxEA12x12AlarmMqttTopicClear mandatory
MQTT Publish: Topic CLEAR message
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.69
wtWebio577xxEA12x12AlarmSetOutputsOwn mandatory
This variable allows setting of individual output.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mask which determine…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.70
wtWebio577xxEA12x12AlarmSetOutputsServerIp mandatory
Set Outputs: Server IP Address
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.71
wtWebio577xxEA12x12AlarmSetOutputsServerPort mandatory
Set Outputs: Server Port
Integer32r/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.72
wtWebio577xxEA12x12AlarmSetOutputsServerPassword mandatory
Set Outputs: Server Pasword
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.73
wtWebio577xxEA12x12AlarmSetOutputsServerOutputs mandatory
This variable allows setting of individual output.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mask which determine…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.74
wtWebio577xxEA12x12AlarmSetOutputsDest mandatory
Binary coded value:
Bit 0 = LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : set outputs of remote server.
Bit 0 : set outputs of this WEB-IO
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.75
wtWebio577xxEA12x12AlarmSnmpManagerPort mandatory
Port number of the SNMP Manager to which the Webio device should send SNMP traps.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.76
wtWebio577xxEA12x12AlarmMqttQoS mandatory
Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: QoS 0
Bit 1: QoS 1
Bit 2: QoS 2
Bit 3-7:unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.77
wtWebio577xxEA12x12AlarmMqttRetain mandatory
Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : retain enable
Bit 1-7 : unused
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.1.5.3.1.78
.1.3.6.1.4.1.5040.1.2.49.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebio577xxEA12x12InputPortEntry entry .1.3.6.1.4.1.5040.1.2.49.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x12PortInputName mandatory
Name of the input.
OctetStringr/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.49.3.2.1.1.1
wtWebio577xxEA12x12PortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.2.1.1.2
wtWebio577xxEA12x12PortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.2.1.1.3
wtWebio577xxEA12x12PortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Constraints:
range: 1-65535
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.49.3.2.1.1.4
wtWebio577xxEA12x12PortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.2.1.1.5
wtWebio577xxEA12x12PortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.49.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.49.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebio577xxEA12x12OutputPortEntry entry .1.3.6.1.4.1.5040.1.2.49.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x12PortOutputName mandatory
Name of the output.
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.49.3.2.2.1.1
wtWebio577xxEA12x12PortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.2.2.1.2
wtWebio577xxEA12x12PortOutputGroupMode mandatory
It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be set all together in the same way. This v…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.2.2.1.3
wtWebio577xxEA12x12PortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.2.2.1.4
wtWebio577xxEA12x12PortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (wt…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.2.2.1.5
wtWebio577xxEA12x12PortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: Bit 0-3 : inputs 8-11
OCTET 4: Bit 0-7 : inputs 0-7
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.2.2.1.6
wtWebio577xxEA12x12PortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.2.2.1.7
wtWebio577xxEA12x12PortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: Bit 0-3 : Output Inverter enable 8-11
OCTET 4: Bit 0-7 : Output Inverter enable 0-7
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.2.2.1.8
wtWebio577xxEA12x12PortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.49.3.2.2.1.9
wtWebio577xxEA12x12PortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebio577xxEA12x12PortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unus…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.49.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.51.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebio577xxEA12x6RelInputEntry entry .1.3.6.1.4.1.5040.1.2.51.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x6RelInputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.51.1.3.1.1
wtWebio577xxEA12x6RelInputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.51.1.3.1.2
wtWebio577xxEA12x6RelInputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.51.1.3.1.3
wtWebio577xxEA12x6RelInputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.51.1.3.1.4
.1.3.6.1.4.1.5040.1.2.51.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebio577xxEA12x6RelOutputEntry entry .1.3.6.1.4.1.5040.1.2.51.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x6RelOutputNo mandatory
Output number.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.51.1.5.1.1
wtWebio577xxEA12x6RelOutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.51.1.5.1.2
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebio577xxEA12x6RelBinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x6RelBinaryModeNo mandatory
Number of the binary channel.
Integer32
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3 · 1 row entry · 23 columns
Table of properties of the binary mode.
wtWebio577xxEA12x6RelBinaryEntry entry .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x6RelBinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.1
wtWebio577xxEA12x6RelBinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 12-12
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.2
wtWebio577xxEA12x6RelBinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.3
wtWebio577xxEA12x6RelBinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.4
wtWebio577xxEA12x6RelBinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.5
wtWebio577xxEA12x6RelBinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.6
wtWebio577xxEA12x6RelBinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.7
wtWebio577xxEA12x6RelBinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.8
wtWebio577xxEA12x6RelBinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.9
wtWebio577xxEA12x6RelBinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.10
wtWebio577xxEA12x6RelBinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.11
wtWebio577xxEA12x6RelBinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.12
wtWebio577xxEA12x6RelBinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.13
wtWebio577xxEA12x6RelBinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.14
wtWebio577xxEA12x6RelBinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.15
wtWebio577xxEA12x6RelBinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.16
wtWebio577xxEA12x6RelBinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.17
wtWebio577xxEA12x6RelBinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.18
wtWebio577xxEA12x6RelBinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32 .1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.19
wtWebio577xxEA12x6RelBinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.20
wtWebio577xxEA12x6RelBinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.21
wtWebio577xxEA12x6RelBinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.22
wtWebio577xxEA12x6RelBinaryTcpClientServerUserName mandatory
User Name to login at the remote server, if authentication needed.
OctetString
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.51.3.1.3.6.3.1.23
.1.3.6.1.4.1.5040.1.2.51.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebio577xxEA12x6RelOutputModeEntry entry .1.3.6.1.4.1.5040.1.2.51.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x6RelOutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corres…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.51.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.51.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebio577xxEA12x6RelAlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.51.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x6RelAlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.51.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.51.3.1.5.3 · 1 row entry · 54 columns
List of settings depending on the alarm number.
wtWebio577xxEA12x6RelAlarmEntry entry .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x6RelAlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.1
wtWebio577xxEA12x6RelAlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.2
wtWebio577xxEA12x6RelAlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.3
wtWebio577xxEA12x6RelAlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebio577xxEA12x6RelAlarmInputTrigger ar…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.4
wtWebio577xxEA12x6RelAlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.5
wtWebio577xxEA12x6RelAlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Bit 0: UDP enable
Bit1-7: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
Bit 3: Syslog Messages enable
Bit 4: F…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.6
wtWebio577xxEA12x6RelAlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.7
wtWebio577xxEA12x6RelAlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.8
wtWebio577xxEA12x6RelAlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.9
wtWebio577xxEA12x6RelAlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.10
wtWebio577xxEA12x6RelAlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.11
wtWebio577xxEA12x6RelAlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.12
wtWebio577xxEA12x6RelAlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.13
wtWebio577xxEA12x6RelAlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.14
wtWebio577xxEA12x6RelAlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.15
wtWebio577xxEA12x6RelAlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.16
wtWebio577xxEA12x6RelAlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.17
wtWebio577xxEA12x6RelAlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.18
wtWebio577xxEA12x6RelAlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.19
wtWebio577xxEA12x6RelAlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.20
wtWebio577xxEA12x6RelAlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.21
wtWebio577xxEA12x6RelAlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.22
wtWebio577xxEA12x6RelAlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.23
wtWebio577xxEA12x6RelAlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.24
wtWebio577xxEA12x6RelAlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.25
wtWebio577xxEA12x6RelAlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.26
wtWebio577xxEA12x6RelAlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.27
wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.28
wtWebio577xxEA12x6RelAlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.29
wtWebio577xxEA12x6RelAlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.30
wtWebio577xxEA12x6RelAlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.31
wtWebio577xxEA12x6RelAlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.32
wtWebio577xxEA12x6RelAlarmGlobalEnable mandatory
Binary coded alarm activation:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Alarm enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.34
wtWebio577xxEA12x6RelAlarmCombinationLogic mandatory
Binary coded logic, all Input/Output-trigger will be combined:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : OR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.58
wtWebio577xxEA12x6RelAlarmTrgMqttTopic mandatory
MQTT subscribe topic.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.59
wtWebio577xxEA12x6RelAlarmTrgMqttTopicText mandatory
Receiving this text from the MQTT Broker, Alarm will be triggered.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.60
wtWebio577xxEA12x6RelAlarmHttpReqAuthEnable mandatory
Binary coded value:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : HHTP Request Authentication enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.61
wtWebio577xxEA12x6RelAlarmHttpReqAuthUser mandatory
HTTP Request: User
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.62
wtWebio577xxEA12x6RelAlarmHttpReqAuthPassword mandatory
HTTP Request: Password
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.63
wtWebio577xxEA12x6RelAlarmHttpReqSetUrl mandatory
HTTP Request: Set URL
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.64
wtWebio577xxEA12x6RelAlarmHttpReqClearUrl mandatory
HTTP Request: Clear URL
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.65
wtWebio577xxEA12x6RelAlarmHttpReqServerPort mandatory
HTTP Request: Server Port
Integer32r/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.66
wtWebio577xxEA12x6RelAlarmMqttTopicPath mandatory
MQTT Publish: Topic path
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.67
wtWebio577xxEA12x6RelAlarmMqttTopicSetTopic mandatory
MQTT Publish: Topic SET message
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.68
wtWebio577xxEA12x6RelAlarmMqttTopicClear mandatory
MQTT Publish: Topic CLEAR message
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.69
wtWebio577xxEA12x6RelAlarmSetOutputsOwn mandatory
This variable allows setting of individual output.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mask which determine…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.70
wtWebio577xxEA12x6RelAlarmSetOutputsServerIp mandatory
Set Outputs: Server IP Address
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.71
wtWebio577xxEA12x6RelAlarmSetOutputsServerPort mandatory
Set Outputs: Server Port
Integer32r/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.72
wtWebio577xxEA12x6RelAlarmSetOutputsServerPassword mandatory
Set Outputs: Server Pasword
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.73
wtWebio577xxEA12x6RelAlarmSetOutputsServerOutputs mandatory
This variable allows setting of individual output.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mask which determine…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.74
wtWebio577xxEA12x6RelAlarmSetOutputsDest mandatory
Binary coded value:
Bit 0 = LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : set outputs of remote server.
Bit 0 : set outputs of this WEB-IO
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.75
wtWebio577xxEA12x6RelAlarmSnmpManagerPort mandatory
Port number of the SNMP Manager to which the Webio device should send SNMP traps.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.76
wtWebio577xxEA12x6RelAlarmMqttQoS mandatory
Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: QoS 0
Bit 1: QoS 1
Bit 2: QoS 2
Bit 3-7:unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.77
wtWebio577xxEA12x6RelAlarmMqttRetain mandatory
Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : retain enable
Bit 1-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.1.5.3.1.78
.1.3.6.1.4.1.5040.1.2.51.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebio577xxEA12x6RelInputPortEntry entry .1.3.6.1.4.1.5040.1.2.51.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x6RelPortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.2.1.1.1
wtWebio577xxEA12x6RelPortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.2.1.1.2
wtWebio577xxEA12x6RelPortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.2.1.1.3
wtWebio577xxEA12x6RelPortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.51.3.2.1.1.4
wtWebio577xxEA12x6RelPortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.2.1.1.5
wtWebio577xxEA12x6RelPortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.51.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.51.3.2.2 · 1 row entry · 6 columns
List of settings depending on the output number.
wtWebio577xxEA12x6RelOutputPortEntry entry .1.3.6.1.4.1.5040.1.2.51.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA12x6RelPortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.2.2.1.1
wtWebio577xxEA12x6RelPortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.2.2.1.2
wtWebio577xxEA12x6RelPortOutputGroupMode mandatory
No function within this device.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.2.2.1.3
wtWebio577xxEA12x6RelPortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.2.2.1.4
wtWebio577xxEA12x6RelPortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.51.3.2.2.1.9
wtWebio577xxEA12x6RelPortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebio577xxEA12x6RelPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: un…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.51.3.2.2.1.10
.1.3.6.1.4.1.5040.1.2.52.1.3 · 1 row entry · 4 columns
List of input indices.
wtWebio577xxEA2x2InputEntry entry .1.3.6.1.4.1.5040.1.2.52.1.3.1
Number of the inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA2x2InputNo mandatory
Index numbers of the inputs.
Integer32 .1.3.6.1.4.1.5040.1.2.52.1.3.1.1
wtWebio577xxEA2x2InputCounter mandatory
Value of the input counter.
Integer32 .1.3.6.1.4.1.5040.1.2.52.1.3.1.2
wtWebio577xxEA2x2InputCounterClear mandatory
Clears the input counter after returning its value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.52.1.3.1.3
wtWebio577xxEA2x2InputState mandatory
Value of a single input bit, 0-OFF, 1-ON.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.52.1.3.1.4
.1.3.6.1.4.1.5040.1.2.52.1.5 · 1 row entry · 2 columns
List of output indices.
wtWebio577xxEA2x2OutputEntry entry .1.3.6.1.4.1.5040.1.2.52.1.5.1
Number of the outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA2x2OutputNo mandatory
Output number.
Integer32 .1.3.6.1.4.1.5040.1.2.52.1.5.1.1
wtWebio577xxEA2x2OutputState mandatory
Value of a single output bit, 0-OFF, 1-ON.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.52.1.5.1.2
.1.3.6.1.4.1.5040.1.2.52.3.1.3.6.2 · 1 row entry · 1 columns
Table of indices.
wtWebio577xxEA2x2BinaryIfEntry entry .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.2.1
Indices of the binary channels.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA2x2BinaryModeNo mandatory
Number of the binary channel.
Integer32 .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.2.1.1
.1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3 · 1 row entry · 23 columns
Table of properties of the binary mode.
wtWebio577xxEA2x2BinaryEntry entry .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1
Binary properties.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA2x2BinaryOperationMode mandatory
Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : UDP Peer
Bit 1 : TCP Client
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.1
wtWebio577xxEA2x2BinaryTcpServerLocalPort mandatory
Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.2
wtWebio577xxEA2x2BinaryTcpServerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.3
wtWebio577xxEA2x2BinaryTcpServerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
Bit 3 : OPC Device
Bit 2 : Box2Box S…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.4
wtWebio577xxEA2x2BinaryTcpClientLocalPort mandatory
Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.5
wtWebio577xxEA2x2BinaryTcpClientServerPort mandatory
Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.6
wtWebio577xxEA2x2BinaryTcpClientServerIpAddr mandatory
Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.7
wtWebio577xxEA2x2BinaryTcpClientServerPassword mandatory
Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exists.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.8
wtWebio577xxEA2x2BinaryTcpClientInactivity mandatory
Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box2Box mode this function is
disabled.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.9
wtWebio577xxEA2x2BinaryTcpClientInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.10
wtWebio577xxEA2x2BinaryTcpClientInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.11
wtWebio577xxEA2x2BinaryTcpClientApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : Box2Box Slave
Bit 1 : Compat…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.12
wtWebio577xxEA2x2BinaryUdpPeerLocalPort mandatory
Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual).
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.13
wtWebio577xxEA2x2BinaryUdpPeerRemotePort mandatory
Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote port to zero.
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.14
wtWebio577xxEA2x2BinaryUdpPeerRemoteIpAddr mandatory
Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote device IP address to 0.0.0.0.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.15
wtWebio577xxEA2x2BinaryUdpPeerInputTrigger mandatory
Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless every transmission will contain all input …
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.16
wtWebio577xxEA2x2BinaryUdpPeerInterval mandatory
Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending.
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.17
wtWebio577xxEA2x2BinaryUdpPeerApplicationMode mandatory
Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.18
wtWebio577xxEA2x2BinaryConnectedPort mandatory
Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read.
Integer32 .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.19
wtWebio577xxEA2x2BinaryConnectedIpAddr mandatory
IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read.
RFC1155-SMIIpAddress
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.20
wtWebio577xxEA2x2BinaryTcpServerClientHttpPort mandatory
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx.
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.21
wtWebio577xxEA2x2BinaryTcpClientServerHttpPort mandatory
HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port.
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.22
wtWebio577xxEA2x2BinaryTcpClientServerUserName mandatory
User Name to login at the remote server, if authentication needed.
OctetString .1.3.6.1.4.1.5040.1.2.52.3.1.3.6.3.1.23
.1.3.6.1.4.1.5040.1.2.52.3.1.4.1 · 1 row entry · 1 columns
Table of output mode configurations dependent on the output indices.
wtWebio577xxEA2x2OutputModeEntry entry .1.3.6.1.4.1.5040.1.2.52.3.1.4.1.1
Output mode configurations of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA2x2OutputModeBit mandatory
This binary coded output mode defines the individual operation mode for any
output. More than one mode must not be selected.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corres…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.4.1.1.1
.1.3.6.1.4.1.5040.1.2.52.3.1.5.2 · 1 row entry · 1 columns
List of alarm indices.
wtWebio577xxEA2x2AlarmIfEntry entry .1.3.6.1.4.1.5040.1.2.52.3.1.5.2.1
Numbers of the alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA2x2AlarmNo mandatory
Numbers of the alarms.
Integer32 .1.3.6.1.4.1.5040.1.2.52.3.1.5.2.1.1
.1.3.6.1.4.1.5040.1.2.52.3.1.5.3 · 1 row entry · 54 columns
List of settings depending on the alarm number.
wtWebio577xxEA2x2AlarmEntry entry .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA2x2AlarmInputTrigger mandatory
This variable allows setting of individual input trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mas…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.1
wtWebio577xxEA2x2AlarmOutputTrigger mandatory
This variable allows setting of individual output trigger conditions.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the m…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.2
wtWebio577xxEA2x2AlarmSystemTrigger mandatory
Binary coded trigger conditions:
The OCTETS are interpreted bit-by-bit.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4,
Bit 4-7: unused
Bit 3 : Warm Start
Bit 2 : Cold Sta…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.3
wtWebio577xxEA2x2AlarmMaxCounterValue mandatory
This variable configures a max. counter value. If an input counter value
exceeds this max. value, the corresponding alarm is triggered. Input counters with
its mask bit unset in wtWebio577xxEA2x2AlarmInputTrigger are no…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.4
wtWebio577xxEA2x2AlarmInterval mandatory
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.5
wtWebio577xxEA2x2AlarmEnable mandatory
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Bit 0: UDP enable
Bit1-7: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
Bit 3: Syslog Messages enable
Bit 4: F…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.6
wtWebio577xxEA2x2AlarmMailAddr mandatory
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.7
wtWebio577xxEA2x2AlarmMailSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.8
wtWebio577xxEA2x2AlarmMailText mandatory
Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.9
wtWebio577xxEA2x2AlarmSnmpManagerIP mandatory
IP address of the SNMP Manager to which the Webio device should send SNMP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.10
wtWebio577xxEA2x2AlarmSnmpTrapText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.11
wtWebio577xxEA2x2AlarmUdpIpAddr mandatory
IP address of the UDP listener to which the Webio device should send UDP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.12
wtWebio577xxEA2x2AlarmUdpPort mandatory
Port number of the UDP listener to which the Webio device should send UDP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.13
wtWebio577xxEA2x2AlarmUdpText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.14
wtWebio577xxEA2x2AlarmTcpIpAddr mandatory
IP address of the TCP listener to which the Webio device should send TCP traps.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.15
wtWebio577xxEA2x2AlarmTcpPort mandatory
Port number of the TCP listener to which the Webio device should send TCP traps.
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.16
wtWebio577xxEA2x2AlarmTcpText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.17
wtWebio577xxEA2x2AlarmSyslogIpAddr mandatory
IP address of the syslog server to which the Webio device should send syslog messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.18
wtWebio577xxEA2x2AlarmSyslogPort mandatory
Port number of the syslog server to which the Webio device should send syslog messages.
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.19
wtWebio577xxEA2x2AlarmSyslogText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.20
wtWebio577xxEA2x2AlarmFtpDataPort mandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.21
wtWebio577xxEA2x2AlarmFtpFileName mandatory
Name of the file including path informations.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.22
wtWebio577xxEA2x2AlarmFtpText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.23
wtWebio577xxEA2x2AlarmFtpOption mandatory
Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file

Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STOR…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.24
wtWebio577xxEA2x2AlarmTimerCron mandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Rang…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.25
wtWebio577xxEA2x2AlarmMailReleaseSubject mandatory
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.26
wtWebio577xxEA2x2AlarmMailReleaseText mandatory
Release Alarm mail text:
States of the Webio device can be included by using special tags.
Please refer to the respective Webio manual
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.27
wtWebio577xxEA2x2AlarmSnmpTrapReleaseText mandatory
This text appears in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.28
wtWebio577xxEA2x2AlarmUdpReleaseText mandatory
This text appears in the UDP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.29
wtWebio577xxEA2x2AlarmTcpReleaseText mandatory
This text appears in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.30
wtWebio577xxEA2x2AlarmSyslogReleaseText mandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.31
wtWebio577xxEA2x2AlarmFtpReleaseText mandatory
Message text to store on the FTP server.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.32
wtWebio577xxEA2x2AlarmGlobalEnable mandatory
Binary coded alarm activation:
Bit 0 = LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : Alarm enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.34
wtWebio577xxEA2x2AlarmCombinationLogic mandatory
Binary coded logic:
Bit 0 = LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : OR
Bit 0 : AND
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.58
wtWebio577xxEA2x2AlarmTrgMqttTopic mandatory
MQTT subscribe topic.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.59
wtWebio577xxEA2x2AlarmTrgMqttTopicText mandatory
Reveiving this message from the MQTT Broker, this alarm will be triggered.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.60
wtWebio577xxEA2x2AlarmHttpReqAuthEnable mandatory
Binnary coded value:
Bit 0 = LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 1-7: unused
Bit 0 : HHTP Request Authentication enable
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.61
wtWebio577xxEA2x2AlarmHttpReqAuthUser mandatory
HTTP Request: User
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.62
wtWebio577xxEA2x2AlarmHttpReqAuthPassword mandatory
HTTP Request: Password
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.63
wtWebio577xxEA2x2AlarmHttpReqSetUrl mandatory
HTTP Request: Set URL
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.64
wtWebio577xxEA2x2AlarmHttpReqClearUrl mandatory
HTTP Request: Clear URL
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.65
wtWebio577xxEA2x2AlarmHttpReqServerPort mandatory
HTTP Request: Server Port
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.66
wtWebio577xxEA2x2AlarmMqttTopicPath mandatory
MQTT Publish: Topic path
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.67
wtWebio577xxEA2x2AlarmMqttTopicSetTopic mandatory
MQTT Publish: Topic SET message
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.68
wtWebio577xxEA2x2AlarmMqttTopicClear mandatory
MQTT Publish: Topic CLEAR message
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.69
wtWebio577xxEA2x2AlarmSetOutputsOwn mandatory
This variable allows setting of individual output.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mask which determine…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.70
wtWebio577xxEA2x2AlarmSetOutputsServerIp mandatory
Set Outputs: Server IP Address
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.71
wtWebio577xxEA2x2AlarmSetOutputsServerPort mandatory
Set Outputs: Server Port
Integer32r/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.72
wtWebio577xxEA2x2AlarmSetOutputsServerPassword mandatory
Set Outputs: Server Pasword
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.73
wtWebio577xxEA2x2AlarmSetOutputsServerOutputs mandatory
This variable allows setting of individual output.
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
The first four OCTETS contain the mask which determine…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.74
wtWebio577xxEA2x2AlarmSetOutputsDest mandatory
Binary coded value:
Bit 0 = LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
Bit 1 : set outputs of remote server.
Bit 0 : set outputs of this WEB-IO
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.75
wtWebio577xxEA2x2AlarmSnmpManagerPort mandatory
Port number of the SNMP Manager to which the Webio device should send SNMP traps.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.76
wtWebio577xxEA2x2AlarmMqttQoS mandatory
Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: QoS 0
Bit 1: QoS 1
Bit 2: QoS 2
Bit 3-7:unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.77
wtWebio577xxEA2x2AlarmMqttRetain mandatory
Binary coded value:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : retain enable
Bit 1-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.1.5.3.1.78
.1.3.6.1.4.1.5040.1.2.52.3.2.1 · 1 row entry · 6 columns
List of settings depending on the input number.
wtWebio577xxEA2x2InputPortEntry entry .1.3.6.1.4.1.5040.1.2.52.3.2.1.1
Input parameter for the individual inputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA2x2PortInputName mandatory
Name of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.1.1.1
wtWebio577xxEA2x2PortInputText mandatory
Description of the input.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.1.1.2
wtWebio577xxEA2x2PortInputMode mandatory
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
interrupt support for counting. Only positive edges are accepted as trigger
source. The maximum counting frequen…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.1.1.3
wtWebio577xxEA2x2PortInputFilter mandatory
Pulses with a duration shorter than here specified (duration in 1/1000 sec),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.52.3.2.1.1.4
wtWebio577xxEA2x2PortInputBicountPulsePolarity mandatory
This value defines the polarity of the input pulse.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : negative polarity
Bit 1 : positive polarity
Bit 2-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.1.1.5
wtWebio577xxEA2x2PortInputBicountInactivTimeout mandatory
Pulse chains with a duration shorter than here specified (in 1/10 sek),
are ignored.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.52.3.2.1.1.6
.1.3.6.1.4.1.5040.1.2.52.3.2.2 · 1 row entry · 10 columns
List of settings depending on the output number.
wtWebio577xxEA2x2OutputPortEntry entry .1.3.6.1.4.1.5040.1.2.52.3.2.2.1
Output parameters of the individual outputs.
Indexes
No indexes recorded
Column Syntax OID
wtWebio577xxEA2x2PortOutputName mandatory
Name of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.2.1.1
wtWebio577xxEA2x2PortOutputText mandatory
Description of the output.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.2.1.2
wtWebio577xxEA2x2PortOutputGroupMode mandatory
It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be set all together in the same way. This v…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.2.1.3
wtWebio577xxEA2x2PortOutputSafetyState mandatory
This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The first four OCTETS contain the mask which d…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.2.1.4
wtWebio577xxEA2x2PortLogicInputMask mandatory
Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take place in 4 steps:
1. Selecting inputs (w…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.2.1.5
wtWebio577xxEA2x2PortLogicInputInverter mandatory
Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 0-1 : inputs 0-1
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.2.1.6
wtWebio577xxEA2x2PortLogicFunction mandatory
This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
Bit 1 : logic function AND
Bit 2-7 :…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.2.1.7
wtWebio577xxEA2x2PortLogicOutputInverter mandatory
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enable
Bit 1-7 : unused
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.2.1.8
wtWebio577xxEA2x2PortPulseDuration mandatory
Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.52.3.2.2.1.9
wtWebio577xxEA2x2PortPulsePolarity mandatory
This value defines the polarity of the output pulse, if wtWebio577xxEA2x2PortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite state.
OCTET 1: unused
OCTET 2: unused…
OctetStringr/w .1.3.6.1.4.1.5040.1.2.52.3.2.2.1.10