wtWebioEA12x12PortOutputGroupMode
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.4.3.2.2.1.3
Object
column
mandatory
r/w
OctetString
It is possible to connect outputs together to increase the output current. This could be done by connecting 2 or 4 outputs in a group together. All bits of such a group has to be set all together in the same way. This variable configures this group scheme. If one output bit of a group is set, all other output bits of the same group will be set in the same manner. More than one configuration must not be selected. Selection for outputs 0-3: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default) Bit 1 : outputs 0+1, 2+3 connected Bit 2 : outputs 0+1+2+3 connected Bit 3-7 : unused Selection for outputs 4-7: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 4, 5, 6, 7 disconnected (default) Bit 1 : outputs 4+5, 6+7 connected Bit 2 : outputs 4+5+6+7 connected Bit 3-7 : unused Selection for outputs 8-11: Octet 1: unused Octet 2: unused Octet 3: unused OCTET 4: Bit 0 : outputs 8, 9, 10, 11 disconnected (default) Bit 1 : outputs 8+9, 10+11 connected Bit 2 : outputs 8+9+10+11 connected Bit 3-7 : unused
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.4.3.2.2.1.3- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebioEA12x12OutputPortEntry
- Table
- wtWebioEA12x12OutputPortTable
- Siblings
- 9
Syntax
OctetString
Values & Constraints
Object Constraints
range: 1-1
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebioEA12x12PortOutputName mandatory Name of the output. | column | OctetString | .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.1 |
| wtWebioEA12x12PortPulsePolarity mandatory This value defines the polarity of the output pulse, if wtWebioEA12x12PortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite s… | column | OctetString | .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.10 |
| wtWebioEA12x12PortOutputText mandatory Description of the output. | column | OctetString | .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.2 |
| wtWebioEA12x12PortOutputSafetyState mandatory This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The fi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.4 |
| wtWebioEA12x12PortLogicInputMask mandatory Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take pla… | column | OctetString | .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.5 |
| wtWebioEA12x12PortLogicInputInverter mandatory Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: Bit 0-3 : inputs 8-11
Bit 4-7 : unused
OCTET 4:
Bit 0-7 : inputs 0-7 | column | OctetString | .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.6 |
| wtWebioEA12x12PortLogicFunction mandatory This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.7 |
| wtWebioEA12x12PortLogicOutputInverter mandatory The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enab… | column | OctetString | .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.8 |
| wtWebioEA12x12PortPulseDuration mandatory Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.4.3.2.2.1.9 |