wtWebioEA6x6BinaryTcpClientServerHttpPort
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.22
Object
column
mandatory
r/w
Integer32
HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port.
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.22- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebioEA6x6BinaryEntry
- Table
- wtWebioEA6x6BinaryTable
- Siblings
- 21
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebioEA6x6BinaryOperationMode mandatory Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.1 |
| wtWebioEA6x6BinaryTcpClientInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.10 |
| wtWebioEA6x6BinaryTcpClientInterval mandatory Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.11 |
| wtWebioEA6x6BinaryTcpClientApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.12 |
| wtWebioEA6x6BinaryUdpPeerLocalPort mandatory Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.13 |
| wtWebioEA6x6BinaryUdpPeerRemotePort mandatory Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote por… | column | Integer32 | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.14 |
| wtWebioEA6x6BinaryUdpPeerRemoteIpAddr mandatory Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote devi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.15 |
| wtWebioEA6x6BinaryUdpPeerInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.16 |
| wtWebioEA6x6BinaryUdpPeerInterval mandatory Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.17 |
| wtWebioEA6x6BinaryUdpPeerApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.18 |
| wtWebioEA6x6BinaryConnectedPort mandatory Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.19 |
| wtWebioEA6x6BinaryTcpServerLocalPort mandatory Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.2 |
| wtWebioEA6x6BinaryConnectedIpAddr mandatory IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read. | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.20 |
| wtWebioEA6x6BinaryTcpServerClientHttpPort mandatory HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.21 |
| wtWebioEA6x6BinaryTcpServerInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.3 |
| wtWebioEA6x6BinaryTcpServerApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.4 |
| wtWebioEA6x6BinaryTcpClientLocalPort mandatory Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.5 |
| wtWebioEA6x6BinaryTcpClientServerPort mandatory Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to ze… | column | Integer32 | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.6 |
| wtWebioEA6x6BinaryTcpClientServerIpAddr mandatory Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address … | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.7 |
| wtWebioEA6x6BinaryTcpClientServerPassword mandatory Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exis… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.8 |
| wtWebioEA6x6BinaryTcpClientInactivity mandatory Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box… | column | Integer32 | .1.3.6.1.4.1.5040.1.2.24.3.1.3.6.3.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebioEA12x6RelERPOutputNo mandatory Output number. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.26.1.5.1.1 |