wtWebioEA24oemPortOutputText
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.14.3.2.2.1.2
Object
column
mandatory
r/w
OctetString
Description of the output.
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.14.3.2.2.1.2- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebioEA24oemOutputPortEntry
- Table
- wtWebioEA24oemOutputPortTable
- Siblings
- 9
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebioEA24oemPortOutputName mandatory Name of the output. | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.1 |
| wtWebioEA24oemPortPulsePolarity mandatory This value defines the polarity of the output pulse, if wtWebioEA24oemPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite s… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.10 |
| wtWebioEA24oemPortOutputGroupMode mandatory It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be … | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.3 |
| wtWebioEA24oemPortOutputSafetyState mandatory This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The fi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.4 |
| wtWebioEA24oemPortLogicInputMask mandatory Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take pla… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.5 |
| wtWebioEA24oemPortLogicInputInverter mandatory Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: Bit 0-7 : inputs 16 - 23
OCTET 3: Bit 0-7 : inputs 8 - 15
OCTET 4: Bit 0-7 : inputs 0 - 7 | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.6 |
| wtWebioEA24oemPortLogicFunction mandatory This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.7 |
| wtWebioEA24oemPortLogicOutputInverter mandatory The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enab… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.8 |
| wtWebioEA24oemPortPulseDuration mandatory Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.14.3.2.2.1.9 |