wtWebCount6ReportTimerCron

Webio-Digital-MIB-US · .1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.25

Object

column mandatory r/w OctetString
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a report, weekday and day of month
are interpreted separatley.
1: Minutes	Range 0-59
2. Hours	Range 0-23, 0 is midnight
3: Day of month	Range 1-31
4: Month	Range 1-12
5: Weekday	Range 0-6, 0 is sunday
              
Syntax for every field:
 - an asterix (*) enables every possible setting of a field
 - single numbers seperated by commas
 - a partition within the allowed range (1-5)
 - step size within an partition of the allowed range (0-59/2: every second minute).

Context

MIB
Webio-Digital-MIB-US
OID
.1.3.6.1.4.1.5040.1.2.22.3.1.5.3.1.25
Type
column
Access
readwrite
Status
mandatory
Parent
wtWebCount6ReportEntry
Table
wtWebCount6ReportTable
Siblings
29

Syntax

OctetString

Values & Constraints

No enumerated values or constraints recorded.