wtWebio577xxEA12x12BinaryTcpClientInactivity
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.9
Object
column
mandatory
r/w
Integer32
Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled.
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.9- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebio577xxEA12x12BinaryEntry
- Table
- wtWebio577xxEA12x12BinaryTable
- Siblings
- 22
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Object Constraints
range: 4-4
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebio577xxEA12x12BinaryOperationMode mandatory Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.1 |
| wtWebio577xxEA12x12BinaryTcpClientInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.10 |
| wtWebio577xxEA12x12BinaryTcpClientInterval mandatory Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.11 |
| wtWebio577xxEA12x12BinaryTcpClientApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.12 |
| wtWebio577xxEA12x12BinaryUdpPeerLocalPort mandatory Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.13 |
| wtWebio577xxEA12x12BinaryUdpPeerRemotePort mandatory Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote por… | column | Integer32 | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.14 |
| wtWebio577xxEA12x12BinaryUdpPeerRemoteIpAddr mandatory Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote devi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.15 |
| wtWebio577xxEA12x12BinaryUdpPeerInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.16 |
| wtWebio577xxEA12x12BinaryUdpPeerInterval mandatory Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.17 |
| wtWebio577xxEA12x12BinaryUdpPeerApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.18 |
| wtWebio577xxEA12x12BinaryConnectedPort mandatory Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.19 |
| wtWebio577xxEA12x12BinaryTcpServerLocalPort mandatory Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.2 |
| wtWebio577xxEA12x12BinaryConnectedIpAddr mandatory IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read. | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.20 |
| wtWebio577xxEA12x12BinaryTcpServerClientHttpPort mandatory HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
status informations will be send to this port.
Not used at mode Compatible 50xxx. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.21 |
| wtWebio577xxEA12x12BinaryTcpClientServerHttpPort mandatory HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.22 |
| wtWebio577xxEA12x12BinaryTcpClientServerUserName mandatory User Name to login at the remote server, if authentication needed. | column | OctetString | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.23 |
| wtWebio577xxEA12x12BinaryTcpServerInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.3 |
| wtWebio577xxEA12x12BinaryTcpServerApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.4 |
| wtWebio577xxEA12x12BinaryTcpClientLocalPort mandatory Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.5 |
| wtWebio577xxEA12x12BinaryTcpClientServerPort mandatory Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to ze… | column | Integer32 | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.6 |
| wtWebio577xxEA12x12BinaryTcpClientServerIpAddr mandatory Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address … | column | OctetString | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.7 |
| wtWebio577xxEA12x12BinaryTcpClientServerPassword mandatory Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exis… | column | OctetString | .1.3.6.1.4.1.5040.1.2.49.3.1.3.6.3.1.8 |