wtWebio577xxEA1x1OutputModeBit
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.48.3.1.4.1.1.1
Object
column
mandatory
r/w
OctetString
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: Bit 7 : unused Bit 6 : unused Bit 5 : unused Bit 4 : unused Bit 3 : unused Bit 2 : unused Bit 1 : REST Bit 0 : AJAX OCTET 3: Bit 7 : Web Alarm Bit 6 : ASCII Socket Bit 5 : Time Switch Bit 4 : Logic Bit 3 : Binary 9 Bit 2 : Binary 8 Bit 1 : Binary 7 Bit 0 : Binary 6 OCTET 4: Bit 7 : Binary 5 Bit 6 : Binary 4 Bit 5 : Binary 3 Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.48.3.1.4.1.1.1- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebio577xxEA1x1OutputModeEntry
- Table
- wtWebio577xxEA1x1OutputModeTable
Syntax
OctetString
Values & Constraints
Object Constraints
range: 4-4