wtWebioEA12x6RelERPOutputModeBit
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.26.3.1.4.1.1.1
Object
column
mandatory
r/w
OctetString
This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Logic Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.26.3.1.4.1.1.1- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebioEA12x6RelERPOutputModeEntry
- Table
- wtWebioEA12x6RelERPOutputModeTable
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.