wtWebioEA2x2ERP-24VPortLogicFunction
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.31.3.2.2.1.7
Object
column
mandatory
r/w
OctetString
This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.31.3.2.2.1.7- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebioEA2x2ERP-24VOutputPortEntry
- Table
- wtWebioEA2x2ERP-24VOutputPortTable
- Siblings
- 9
Syntax
OctetString
Values & Constraints
Object Constraints
range: 1-65535
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebioEA2x2ERP-24VPortOutputName mandatory Name of the output. | column | OctetString | .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.1 |
| wtWebioEA2x2ERP-24VPortPulsePolarity mandatory This value defines the polarity of the output pulse, if wtWebioEA2x2ERP-24VPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the oppos… | column | OctetString | .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.10 |
| wtWebioEA2x2ERP-24VPortOutputText mandatory Description of the output. | column | OctetString | .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.2 |
| wtWebioEA2x2ERP-24VPortOutputGroupMode mandatory It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be … | column | OctetString | .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.3 |
| wtWebioEA2x2ERP-24VPortOutputSafetyState mandatory This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The fi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.4 |
| wtWebioEA2x2ERP-24VPortLogicInputMask mandatory Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take pla… | column | OctetString | .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.5 |
| wtWebioEA2x2ERP-24VPortLogicInputInverter mandatory Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 0-1 : inputs 0-1 | column | OctetString | .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.6 |
| wtWebioEA2x2ERP-24VPortLogicOutputInverter mandatory The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enab… | column | OctetString | .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.8 |
| wtWebioEA2x2ERP-24VPortPulseDuration mandatory Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.9 |