wtWebioEA2x2-24VPortInputMode

Webio-Digital-MIB-US · .1.3.6.1.4.1.5040.1.2.30.3.2.1.1.3

Object

column mandatory r/w OctetString
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables 
interrupt support for counting. Only positive edges are accepted as trigger 
source. The maximum counting frequenz equals 2000 Hz.
This mode is available for inputs 0-3 only.
Selecting counter clear on read by setting the corresponding bit to 1 enables
the corresponding counter to be cleared automatically every time it is read,
except HTTP reading with user rights.
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
Selection for input 0-1:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
		 Bit 3	: Bidirectional counter enable
	 Bit 2  : Counter clear on read
	 Bit 1  : Change detection enable (default)
	 Bit 0  : Short Pulse detection enable

Context

MIB
Webio-Digital-MIB-US
OID
.1.3.6.1.4.1.5040.1.2.30.3.2.1.1.3
Type
column
Access
readwrite
Status
mandatory
Parent
wtWebioEA2x2-24VInputPortEntry
Table
wtWebioEA2x2-24VInputPortTable
Siblings
5

Syntax

OctetString

Values & Constraints

No enumerated values or constraints recorded.