wtWebioEA24oemBinaryTcpServerClientHttpPort
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.21
Object
column
mandatory
r/w
Integer32
HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx.
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.21- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebioEA24oemBinaryEntry
- Table
- wtWebioEA24oemBinaryTable
- Siblings
- 21
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebioEA24oemBinaryOperationMode mandatory Selection of the operation mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
B… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.1 |
| wtWebioEA24oemBinaryTcpClientInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.10 |
| wtWebioEA24oemBinaryTcpClientInterval mandatory Configurable interval with a 100ms base, in which the Webio device sends
data to the configured application. A interval of zero stopps the
periodical sending. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.11 |
| wtWebioEA24oemBinaryTcpClientApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.12 |
| wtWebioEA24oemBinaryUdpPeerLocalPort mandatory Local UDP port for data exchange in this peer to peer mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.13 |
| wtWebioEA24oemBinaryUdpPeerRemotePort mandatory Port number of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote por… | column | Integer32 | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.14 |
| wtWebioEA24oemBinaryUdpPeerRemoteIpAddr mandatory Ip address of the remote device. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the remote devi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.15 |
| wtWebioEA24oemBinaryUdpPeerInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.16 |
| wtWebioEA24oemBinaryUdpPeerInterval mandatory Configurable interval with a 100ms base, in which the Webio device sends
data to the configured remote device. A interval of zero stopps the
periodical sending. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.17 |
| wtWebioEA24oemBinaryUdpPeerApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.18 |
| wtWebioEA24oemBinaryConnectedPort mandatory Port number of the remote device, after connection has been established.
In case of no connection or missing port informations a zero will be read. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.19 |
| wtWebioEA24oemBinaryTcpServerLocalPort mandatory Local TCP port for data exchange in this server mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.2 |
| wtWebioEA24oemBinaryConnectedIpAddr mandatory IP address of the remote device, after connection has been established.
In case of no connection or missing port informations 0.0.0.0 will be read. | column | RFC1155-SMIIpAddress | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.20 |
| wtWebioEA24oemBinaryTcpClientServerHttpPort mandatory HTTP port number of the remote device at TCP Client Mode. In the operating mode
Box2Box connection status informations will be exchanged through this port. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.22 |
| wtWebioEA24oemBinaryTcpServerInputTrigger mandatory Every change on the inputs causes their state to be transmitted to the
remote device. To minimize data traffic, individual inputs may be exempted
from this rule. Nevertheless ev… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.3 |
| wtWebioEA24oemBinaryTcpServerApplicationMode mandatory Selection of the application mode:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 4-7: unused
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.4 |
| wtWebioEA24oemBinaryTcpClientLocalPort mandatory Local TCP port for data exchange in this client mode.
This port number must be unique within the device.
Reserved port number must not be used (refere to the manual). | column | Integer32 | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.5 |
| wtWebioEA24oemBinaryTcpClientServerPort mandatory Port number of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server port to ze… | column | Integer32 | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.6 |
| wtWebioEA24oemBinaryTcpClientServerIpAddr mandatory Ip address of the server. A complete set of port number, IP address
and a valid input/output mask starts this mode.
No data exchange take place when setting the server IP address … | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.7 |
| wtWebioEA24oemBinaryTcpClientServerPassword mandatory Building a connection may be protected by the
administrator password of the server. Enter the server password
to establish the connection, if a server administrator password
exis… | column | OctetString | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.8 |
| wtWebioEA24oemBinaryTcpClientInactivity mandatory Connection timeout in 100ms. If no data are exchanged within the specified
time, the device closes the connection to the server.
The value 0 deactivates the timer. Using the Box… | column | Integer32 | .1.3.6.1.4.1.5040.1.2.14.3.1.3.6.3.1.9 |