wtWebioEA24oemPortInputMode

Webio-Digital-MIB-US · .1.3.6.1.4.1.5040.1.2.14.3.2.1.1.3

Object

column mandatory r/w OctetString
Binary coded modes:
Selecting short pulse detection enable by setting the corresponding bit to 1 enables 
interrupt support for counting. Only positive edges are accepted as trigger 
source. The maximum counting frequenz equals 2000 Hz.
This mode is available for inputs 0-3 only.
Selecting counter clear on read by setting the corresponding bit to 1 enables
the corresponding counter to be cleared automatically every time it is read,
except HTTP reading with user rights.
The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an input. 
Bit 0 corresponds to the LSB.
Selection for input 0-3:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 2-7: unused
	 Bit 2  : Counter clear on read
	 Bit 1  : Change detection enable (default)
	 Bit 0  : Short Pulse detection enable
              	 
	Selection for inputs 4-11:
	OCTET 1: unused
	OCTET 2: unused
	OCTET 3: unused
	OCTET 4, Bit 2-7: unused
		 Bit 1  : Counter clear on read
		 Bit 0  : Change detection enable (default)

Context