wtWebioEA2x2ERP-24VPortLogicOutputInverter

Webio-Digital-MIB-US · .1.3.6.1.4.1.5040.1.2.31.3.2.2.1.8

Object

column mandatory r/w OctetString
The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
	OCTET 4: 
	 Bit 0   : Output Inverter enable
	 Bit 1-7 : unused

Context

MIB
Webio-Digital-MIB-US
OID
.1.3.6.1.4.1.5040.1.2.31.3.2.2.1.8
Type
column
Access
readwrite
Status
mandatory
Parent
wtWebioEA2x2ERP-24VOutputPortEntry
Table
wtWebioEA2x2ERP-24VOutputPortTable
Siblings
9

Syntax

OctetString

Values & Constraints

Object Constraints
range: 4-4

Related Objects

Sibling Objects