wtWebCount6PortInputMode

Webio-Digital-MIB-US · .1.3.6.1.4.1.5040.1.2.22.3.2.1.1.3

Object

column mandatory r/w OctetString
Binary coded modes:
The OCTETS are interpreted bit-by-bit,
Bit 0 corresponds to the LSB.
Selection for input 0-1:
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4, Bit 4-7: unused
		 Bit 3	: Bidirectional counter enable
	 Bit 2  : unused
	 Bit 1  : Change detection enable
	 Bit 0  : unused

Context

MIB
Webio-Digital-MIB-US
OID
.1.3.6.1.4.1.5040.1.2.22.3.2.1.1.3
Type
column
Access
readwrite
Status
mandatory
Parent
wtWebCount6InputPortEntry
Table
wtWebCount6InputPortTable
Siblings
8

Syntax

OctetString

Values & Constraints

Object Constraints
range: 4-4

Related Objects

Sibling Objects