wtWebioEA6x6PortLogicFunction
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.24.3.2.2.1.7
Object
column
mandatory
r/w
OctetString
This determines the logic function. No more than one function may be selected. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 0 : logic function OR (default) Bit 1 : logic function AND Bit 2-7 : unused
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.24.3.2.2.1.7- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- wtWebioEA6x6OutputPortEntry
- Table
- wtWebioEA6x6OutputPortTable
- Siblings
- 9
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebioEA6x6PortOutputName mandatory Name of the output. | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.1 |
| wtWebioEA6x6PortPulsePolarity mandatory This value defines the polarity of the output pulse, if wtWebioEA6x6PortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite sta… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.10 |
| wtWebioEA6x6PortOutputText mandatory Description of the output. | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.2 |
| wtWebioEA6x6PortOutputGroupMode mandatory It is possible to connect outputs together to increase the output current.
This could be done by connecting 2 or 4 outputs in a group together. All bits
of such a group has to be … | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.3 |
| wtWebioEA6x6PortOutputSafetyState mandatory This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The fi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.4 |
| wtWebioEA6x6PortLogicInputMask mandatory Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take pla… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.5 |
| wtWebioEA6x6PortLogicInputInverter mandatory Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0-5 : inputs 0-5
Bit 6-7 : unused | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.6 |
| wtWebioEA6x6PortLogicOutputInverter mandatory The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enab… | column | OctetString | .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.8 |
| wtWebioEA6x6PortPulseDuration mandatory Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.24.3.2.2.1.9 |