wtWebioEA12x6RelOutputPortEntry
Webio-Digital-MIB-US ·
.1.3.6.1.4.1.5040.1.2.19.3.2.2.1
Object
row
mandatory
Output parameters of the individual outputs.
Context
- MIB
- Webio-Digital-MIB-US
- OID
.1.3.6.1.4.1.5040.1.2.19.3.2.2.1- Type
- row
- Status
- mandatory
- Parent
- wtWebioEA12x6RelOutputPortTable
- Table
- wtWebioEA12x6RelOutputPortTable
- Children
- 10
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wtWebioEA12x6RelPortOutputName mandatory Name of the output. | column | OctetString | .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.1 |
| wtWebioEA12x6RelPortPulsePolarity mandatory This value defines the polarity of the output pulse, if wtWebioEA12x6RelPortPulseDuration is not set to zero.
After the pulse is finished, the output switches back to the opposite… | column | OctetString | .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.10 |
| wtWebioEA12x6RelPortOutputText mandatory Description of the output. | column | OctetString | .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.2 |
| wtWebioEA12x6RelPortOutputGroupMode mandatory Unused in this device 57634 | column | OctetString | .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.3 |
| wtWebioEA12x6RelPortOutputSafetyState mandatory This variable allows setting of individual digital outputs. The OCTETS are
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
to the LSB.
The fi… | column | OctetString | .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.4 |
| wtWebioEA12x6RelPortLogicInputMask mandatory Selecting one of these inputs by setting the corresponding bit to 1
enables the logic function for the output identified by the index within
this table. The calculation take pla… | column | OctetString | .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.5 |
| wtWebioEA12x6RelPortLogicInputInverter mandatory Every input bit selected here will be inverted.
OCTET 1: unused
OCTET 2: unused
OCTET 3: Bit 0-3 : inputs 8-11
Bit 4-7 : unused
OCTET 4:
Bit 0-7 : inputs 0-7 | column | OctetString | .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.6 |
| wtWebioEA12x6RelPortLogicFunction mandatory This determines the logic function. No more than one function
may be selected.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : logic function OR (default)
… | column | OctetString | .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.7 |
| wtWebioEA12x6RelPortLogicOutputInverter mandatory The logical operation result could be inverteted by setting the corresponding
bit to 1.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4:
Bit 0 : Output Inverter enab… | column | OctetString | .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.8 |
| wtWebioEA12x6RelPortPulseDuration mandatory Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output. | column | Integer32 | .1.3.6.1.4.1.5040.1.2.19.3.2.2.1.9 |