Cisco90Series-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
9
Rows
9
Columns
114

frxBankTable

table mandatory
.1.3.6.1.4.1.1570.1.3.1 · 1 row entry · 2 columns
This Cisco 90 Series Bank Di-group Table contains channel
bank level information for each of the channel bank di-groups
in the system. A di-group is a T1 interface to the frame
relay network. The table is indexed using the Cisco 90 Series
channel bank digroup number
frxBankEntry entry .1.3.6.1.4.1.1570.1.3.1.1
A specific entry in the Cisco 90 Series Bank Di-group
Table. There is one entry for each channel bank di-group
(T1) in the system. There are no entries for unused banks
Indexes
frxBankIndex
Column Syntax OID
frxBankIndex mandatory
Channel Bank Di-group Number. This index is used to address
the various channel banks in the system. This number is the
same as the DLCI number used to communicate with the bank at
the Cisco 90 SNMP Agent. (note that th…
Integer32
Constraints:
range: 16-1007
.1.3.6.1.4.1.1570.1.3.1.1.1
frxBankType mandatory
This is the type of channel bank and is for future use.
D4 banks return a value of 1.
Enumerationr/w
Enumerated Values:
1d4
.1.3.6.1.4.1.1570.1.3.1.1.2

frxChUTable

table mandatory
.1.3.6.1.4.1.1570.1.4.1 · 1 row entry · 16 columns
This Cisco 90 Series Channel Unit Table contains channel unit
level control and statistics for each of the Cisco 90 Series
channel units in the system. The table is indexed
first using the Cisco 90 Series channel bank digroup number,
then the channel unit number (1 to 24).
frxChUEntry entry .1.3.6.1.4.1.1570.1.4.1.1
A specific entry in the Cisco 90 Series Channel Unit Table.
There is one entry for each Cisco 90 Series channel unit in
the system. There are no entries for unused banks or empty
channel unit slots
Indexes
frxBankIndex frxChUIndex
Column Syntax OID
frxChUIndex mandatory
Channel Unit Number. This index is used to address a
specific channel unit in a bank. For D4 channel banks
this number is the same as the physical slot number 1-24
Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.1570.1.4.1.1.1
frxChUType mandatory
Type of Cisco 90 Series channel unit installed.
Enumeration
Enumerated Values:
100cisco90i
.1.3.6.1.4.1.1570.1.4.1.1.2
frxChUVersion mandatory
Cisco 90 Series channel unit version number.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.4.1.1.3
frxSigProtocol mandatory
This is the type of Local In-channel Signaling used
when the subscriber is running frame relay protocol.
It is provided for future use. Set to 1 for T1.617
Annex-D
Enumeration
Enumerated Values:
1annexD
.1.3.6.1.4.1.1570.1.4.1.1.4
frxConfigSrc mandatory
Source for configuring speed and protocol for each port.
1=Data rate and protocol set by DLCI assignment rules
as reported by Annex-D. This option allows control
of these basic parameters from the frame relay switc…
Enumerationr/w
Enumerated Values:
1annexD
2snmp
.1.3.6.1.4.1.1570.1.4.1.1.5
frxDLCIAdLen mandatory
The number of bytes used for the DLCI address.
For future use. 1=two octets.
Enumeration
Enumerated Values:
1twoOctetDlci
.1.3.6.1.4.1.1570.1.4.1.1.6
frxNetInOctets mandatory
Total number of octets received by this channel
unit from Frame Relay Switch (on the T1 interface)
Only frames whose DLCI is addressed to a port on
this channel unit are counted. Bad frames, Annex-D
and SNMP frames are…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.4.1.1.7
frxNetOutOctets mandatory
Total number of octets transmitted to the Frame
Relay Switch (on the T1 interface) by this channel
unit. Annex-D and SNMP frames are not counted. CRC
bytes are not counted
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.4.1.1.8
frxNetBadFrames mandatory
Total number of frames received on the network (T1)
interface that are discarded by this channel unit.
Possible reasons for discard are:
Frame contained HDLC abort (7 or more ones in a row)
Frame had a CRC error
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.4.1.1.9
frxNetHDLCEs mandatory
Network Errored Seconds caused by HDLC aborts (7 or more
ones in a row). Total number of seconds in which a frame
with an HDLC abort is received by this channel unit on
the network (T1) interface. Only frames whose DLCI…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.4.1.1.10
frxNetCRCEs mandatory
Network Errored Seconds caused by CRC errors.
Total number of seconds in which a frame with a CRC
error is received by this channel unit on the network
(T1) interface. Only frames whose DLCI is addressed
to a port on th…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.4.1.1.11
frxNetLinkEs mandatory
Network Errored Seconds caused by Non-integral Bytes.
Total number of seconds in which a frame with a non-integral
number of bytes is received by this channel unit on the
network (T1) interface. Only frames whose DLCI i…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.4.1.1.12
frxNetFrShEs mandatory
Network Errored Seconds caused by Short Frames received.
Total number of seconds in which a frame that is too
short (less than 5 bytes) is received by this channel
unit on the network (T1) interface. Only frames whose
D…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.4.1.1.13
frxNetFrLgEs mandatory
Network Errored Seconds caused by Long Frames received.
Total number of seconds in which a frame that is too
long (more than 8192 bytes) is received by this channel
unit on the network (T1) interface. Only frames whose
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.4.1.1.14
frxNetPPPEs mandatory
Errored seconds caused by bad RFC-1973 (PPP) header.
Total number of seconds in which a frame with an
invalid RFC-1973 (PPP) header is received by this
channel unit on the network (T1) interface. Only frames
whose DLCI …
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.4.1.1.15
frxNetBufEs mandatory
Errored Seconds caused by Buffer Overflow.
Total number of seconds in which a frame received
by this channel unit on the network (T1) interface
was discarded due to insufficient buffer space. Only
frames whose DLCI is a…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.4.1.1.16

frxMgtTable

table mandatory
.1.3.6.1.4.1.1570.1.5.1 · 1 row entry · 10 columns
This table monitors and controls the T1-617 Annex-D
parameters used by the channel units. There is one
table row for every channel unit in every bank. The
table is indexed first using the Cisco 90 Series channel
bank digroup number, then the channel unit number (1 to 24).
For best performance, all of the channel units in a
given bank should be set to identical values.  These
values are typically set using global parameters in the
frxDefaultTable instead of directly via this table.
frxMgtEntry entry .1.3.6.1.4.1.1570.1.5.1.1
A specific entry in the Cisco 90 Series Management Table.
There is one entry for each Cisco 90 Series channel unit
in the system. There are no entries for unused banks or
empty channel unit slots
Indexes
frxBankIndex frxChUIndex
Column Syntax OID
frxPortsInSvc mandatory
Ports in service. The number of ports on a Cisco 90 Series
channel unit that have one or more active PVCs, as determined
by Annex-D.
Integer32
Constraints:
range: 0-4
.1.3.6.1.4.1.1570.1.5.1.1.1
frxMgtT391 mandatory
This controls how often (in seconds) the channel unit
sends an Annex-D poll to the frame relay switch.
This is the Annex-D T391 parameter (Typical value 10)
Integer32r/w
Constraints:
range: 5-30
.1.3.6.1.4.1.1570.1.5.1.1.2
frxMgtT392 mandatory
This controls how long (in seconds) the channel unit
will wait for a subscriber to send it an Annex-D poll
before declaring a link error from the subscriber.
This is the Annex-D T392 parameter (Typical value 15)
Integer32r/w
Constraints:
range: 5-30
.1.3.6.1.4.1.1570.1.5.1.1.3
frxMgtN391 mandatory
This controls how often (in polls) the channel unit
sends a full status inquiry poll to the frame relay
switch instead of a link integrity verification poll.
This is the Annex-D N391 parameter (Typical value 6)
Integer32r/w
Constraints:
range: 1-255
.1.3.6.1.4.1.1570.1.5.1.1.4
frxMgtN392 mandatory
When more than frxMgtN392 errors are detected in any
frxMgtN393 monitored Annex-D events, the network is
declared inactive. This is the Annex-D N392 parameter
(Typical value 3)
Integer32r/w
Constraints:
range: 1-10
.1.3.6.1.4.1.1570.1.5.1.1.5
frxMgtN393 mandatory
When more than frxMgtN392 errors are detected in any
frxMgtN393 monitored Annex-D events, the network is
declared inactive. This is the Annex-D N393 parameter
(Typical value 4)
Integer32r/w
Constraints:
range: 1-10
.1.3.6.1.4.1.1570.1.5.1.1.6
frxNetLinkErrors mandatory
Number of signaling link reliability errors from
network. A signaling reliability error is declared
whenever the channel units did not receive a reply
from the frame relay switch to an Annex-D link
integrity poll or fu…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.5.1.1.7
frxNetProtErrors mandatory
Number of signaling protocol errors from network.
A signaling protocol error is declared whenever
the channel units receive a reply with incorrect
format or sequence numbers from the frame relay
switch in response to an…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.5.1.1.8
frxNetChInactive mandatory
Number of times network Annex-D signaling channel
was declared inactive.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.5.1.1.9
frxNetChStatus mandatory
Current status of the Annex-D signaling channel on
the network side of the channel bank.
Enumeration
Enumerated Values:
1active
2inactive
.1.3.6.1.4.1.1570.1.5.1.1.10

frxMgtPortTable

table mandatory
.1.3.6.1.4.1.1570.1.5.2 · 1 row entry · 4 columns
This table monitors the T1-617 Annex-D link
between the channel units and the subscribers.
There is one table row for every port on every
channel unit in every bank. The table is indexed
first using the channel bank digroup number, then
the channel unit number (1 to 24), and then the
port number (0 to 3).
frxMgtPortEntry entry .1.3.6.1.4.1.1570.1.5.2.1
A specific entry in the Cisco 90 Series Management Port
Table. There is one entry for each port on each
Cisco 90 Series channel unit in the system. There are no
entries for unused banks or empty channel unit
slots.
Indexes
frxBankIndex frxChUIndex frxPortIndex
Column Syntax OID
frxPortIndex mandatory
Which subscriber port on the channel unit is
addressed. Ports are numbered from 0 to 3.
Some channel unit types have less than 4 ports.
Integer32
Constraints:
range: 0-3
.1.3.6.1.4.1.1570.1.5.2.1.1
frxPortLinkErrors mandatory
Number of signaling link reliability errors from
subscriber port. A signaling reliability error is
declared whenever the channel units did not receive
an Annex-D link integrity poll or full status inquiry
poll from the…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.5.2.1.2
frxPortProtErrors mandatory
Number of signaling protocol errors from subscriber
port. A signaling protocol error is declared whenever
the channel units receive an Annex-D link integrity
poll or full status inquiry poll with incorrect
format or seq…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.5.2.1.3
frxPortChInactive mandatory
Number of times the subscriber port Annex-D signaling
channel was declared inactive
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.5.2.1.4

frxPortTable

table mandatory
.1.3.6.1.4.1.1570.1.6.1 · 1 row entry · 20 columns
This Cisco 90 Series Port Table contains per-port control and
statistics for each of the subscriber ports in the
system. The table is indexed first using the Cisco 90 Series
channel bank digroup number, then by the channel
unit number (1 to 24), and finally by the port
number (0-3).
frxPortEntry entry .1.3.6.1.4.1.1570.1.6.1.1
A specific entry in the Cisco 90 Series Port Table. There is
one entry for each port on each Cisco 90 Series channel unit
in the system. There are no entries for unused banks or
empty channel unit slots.
Indexes
frxBankIndex frxChUIndex frxPortIndex
Column Syntax OID
frxPortSpeed mandatory
This is the speed that the channel unit port runs at.
1=56kbps 2=64kbps 3=128kbps 4=144kbps
This parameter can only be changed if frxConfigSrc is
set to SNMP.
Enumerationr/w
Enumerated Values:
1use56kbps
2use64kbps
3use128kbps
4use144kbps
.1.3.6.1.4.1.1570.1.6.1.1.1
frxPortProtocol mandatory
This parameter controls what protocol the channel
unit should expect the subscriber to send on the port.
1=Port uses Frame Relay protocol - no encapsulation
2=Port uses PPP protocol - do RFC-1973 encapsulation
This …
Enumerationr/w
Enumerated Values:
1frameRelay
2ppp
.1.3.6.1.4.1.1570.1.6.1.1.2
frxDSLStatus mandatory
This is the status of the DSL loop to the subscriber.
1=Loop is down.
2=Frx card has achieved physical layer activation with
the first BRITE card or the NT1 if there are no BRITE cards.
3=Link is up but Annex-D is sti…
Enumeration
Enumerated Values:
1loopDown
2dslSyncOnly
3loopUpInactive
4loopUp
.1.3.6.1.4.1.1570.1.6.1.1.3
frxPVCAssigned mandatory
Number of PVCs assigned to Subscriber Port as determined
by Annex-D
Integer32
Constraints:
range: 0-8
.1.3.6.1.4.1.1570.1.6.1.1.4
frxLastChange mandatory
Time since DSL went in sync or lost sync in 0.01
second increments.
RFC1155-SMITimeTicks
Textual Convention: RFC1155-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.5
frxBrite mandatory
Number of BRITE cards downstream. BRITE cards are used
to extend the loop over subscriber loop carrier systems
and are detected via a background polling operation.
Integer32
Constraints:
range: 0-6
.1.3.6.1.4.1.1570.1.6.1.1.6
frxDSLInOctets mandatory
Number of octets received from the subscriber DSL
Does not include Annex-D octets
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.7
frxDSLOutOctets mandatory
Number of octets transmitted to the subscriber DSL.
Does not include Annex-D octets
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.8
frxT1InOctets mandatory
Number of octets received from the network
directed at this subscriber port
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.9
frxT1OutOctets mandatory
Number of octets transmitted to the network
from this subscriber port
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.10
frxDSLBadFrames mandatory
Total number of frames received from this subscriber port
that were discarded. Possible reasons for discard are:
Frame contained HDLC abort (7 or more ones in a row)
Frame had a CRC error
Frame had a non-integr…
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.11
frxDSLHDLCEs mandatory
Subscriber port Errored Seconds caused by HDLC aborts
(7 or more ones in a row). Total number of seconds in
which a frame with an HDLC abort is received from this
port.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.12
frxDSLCRCEs mandatory
Subscriber port Errored Seconds caused by CRC errors.
Total number of seconds in which a frame with a CRC
error is received from this port.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.13
frxDSLLinkEs mandatory
Subscriber port Errored Seconds caused by Non-integral
Bytes. Total number of seconds in which a frame with a
non-integral number of bytes is received from this
port.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.14
frxDSLFrShEs mandatory
Subscriber port Errored Seconds caused by Short Frames.
received Total number of seconds in which a frame that
is too short (less than 5 bytes) is received from this
port.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.15
frxDSLFrLgEs mandatory
Subscriber port Errored Seconds caused by Long Frames
received. Total number of seconds in which a frame that
is too long (more than 8192 bytes) is received from this
port.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.16
frxDSLDLCIEs mandatory
Subscriber port Errored Seconds caused by illegal DLCI.
Total number of seconds in which a frame that has a DLCI
other than 16 to 23 (or 0) is received from this port.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.17
frxTxBuf mandatory
Number of octets in the transmit buffer for this
subscriber port. This data is waiting to be sent
to the network (T1).
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.1.1.18
frxRxBuf mandatory
Number of octets in the receive buffer for this
subscriber port. This data is from the network (T1)
and is waiting to be sent to the subscriber port.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.1.1.19
frxPortNetEs mandatory
Total number of seconds in which a frame received
from the network (T1) and targeted at this subscriber
port was discarded.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.1.1.20

frxCircuitTable

table mandatory
.1.3.6.1.4.1.1570.1.6.2 · 1 row entry · 10 columns
This Cisco 90 Series Circuit Table contains
per-virtual-circuit control and statistics for each of the
permanent virtual circuits in the system. The table is
indexed first using the Cisco 90 Series channel bank
digroup number, then by the channel unit number (1 to 24),
then by the port number (0-3) and finally by the circuit
DLCI number (16 to 23).
frxCircuitEntry entry .1.3.6.1.4.1.1570.1.6.2.1
A specific entry in the Cisco 90 Series Circuit Table.
There is one entry for each permanent virtual circuit
in the system. There are no entries for unused
banks or empty channel unit slots.
Indexes
frxBankIndex frxChUIndex frxPortIndex frxPvcIndex
Column Syntax OID
frxPvcIndex mandatory
This index is the subscriber loop DLCI number of the
permanent virtual circuit. It ranges from 16 to 23.
The corresponding network side DLCI must be assigned
in the frame relay switch and communicated to the Cisco 90
Se…
Integer32
Constraints:
range: 16-23
.1.3.6.1.4.1.1570.1.6.2.1.1
frxCktCIR mandatory
This is the committed information rate (CIR) in bits
per second for the addressed permanent virtual circuit.
(Typical value 1536000/#ports).
Integer32r/w
Constraints:
range: 0-1544000
.1.3.6.1.4.1.1570.1.6.2.1.2
frxCktBc mandatory
This is the Committed Burst Size (Bc) in bits for the
addressed permanent virtual circuit. The time interval
over which the burst is measured is Bc/CIR. (Typically
set to same number as frxCktCIR).
Integer32r/w
Constraints:
range: 0-16777215
.1.3.6.1.4.1.1570.1.6.2.1.3
frxCktBe mandatory
This is the Excess Burst Size (Be) in bits for the
addressed permanent virtual circuit. The time interval
over which the excess burst is measured is Be/CIR.
(Typical value 1536000).
Integer32r/w
Constraints:
range: 0-16777215
.1.3.6.1.4.1.1570.1.6.2.1.4
frxFarEndOpStat mandatory
This is the status of the far end of the frame relay
permanent virtual circuit (through the frame relay
network) as determined by Annex-D.
1=active
2=inactive
Enumeration
Enumerated Values:
1active
2inactive
.1.3.6.1.4.1.1570.1.6.2.1.5
frxCktInOctets mandatory
The number of input octets from the subscriber port
on the addressed permanent virtual circuit. These
octets are destined for the network (T1).
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.2.1.6
frxCktOutOctets mandatory
The number of output octets to the subscriber port
on the addressed permanent virtual circuit. These
octets were received from the network (T1).
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.2.1.7
frxCktInFrames mandatory
The number of input frames from the subscriber port
on the addressed permanent virtual circuit. These
frames are destined for the network (T1).
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.2.1.8
frxCktOutFrames mandatory
The number of output frames to the subscriber port
on the addressed permanent virtual circuit. These
frames were received from the network (T1).
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.2.1.9
frxCktDiscards mandatory
The number of input frames from the subscriber port
on the addressed permanent virtual circuit that were
discarded due to congestion (lack of buffer space or
congestion control.
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.2.1.10

frxUEocTable

table mandatory
.1.3.6.1.4.1.1570.1.6.3 · 1 row entry · 9 columns
This Cisco 90 Series Embedded Operations Channel Table
is used to diagnose and sectionalize problems with the
subscriber loop.  It contains one entry for each of the
Cisco 90 Series channel units in the system. The table
is indexed first using the Cisco 90 Series channel bank
digroup number, then the channel unit number (1 to 24).
frxUEocEntry entry .1.3.6.1.4.1.1570.1.6.3.1
A specific entry in the Cisco 90 Series Embedded Operations
Channel Table. There is one entry for each Cisco 90 Series
channel unit in the system. There are no entries for unused
banks or empty channel unit slots
Indexes
frxBankIndex frxChUIndex
Column Syntax OID
frxTestPort mandatory
This parameter indicates which subscriber port on the
channel unit to test. It has no effect until frxStartTest
is set to start the test. Only one port on a given channel
unit may be tested at a time.
Integer32r/w
Constraints:
range: 0-3
.1.3.6.1.4.1.1570.1.6.3.1.1
frxTestType mandatory
This parameter indicates the type of test to perform. It
has no effect until frxStartTest is set to start the test.
1=Set up a loopback and run a PN-2047 Bit Error Rate Test.
2=Run a (straightaway) PN-2047 Bit Error Rat…
Enumerationr/w
Enumerated Values:
1loopbackAndBert
2bertOnly
3sendCorruptCRC
4loopbackOnly
5localLoopAllPorts
.1.3.6.1.4.1.1570.1.6.3.1.2
frxLoopLoc mandatory
This parameter indicates the location of the loopback or
the card that will send corrupt CRC. It has no effect
until frxStartTest is set to start the test. It has no
effect for a BertOnly test.
7=Local Cisco 90 Series …
Enumerationr/w
Enumerated Values:
1briteCard1
2briteCard2
3briteCard3
4briteCard4
5briteCard5
6briteCard6
7localFrx
8nt1
.1.3.6.1.4.1.1570.1.6.3.1.3
frxLoopCh mandatory
This parameter indicates which channels to use for the
loopbackOnly and localLoopAllPorts test. It has no effect
until frxStartTest is set to start the test. Note that the
loopbackAndBert test always loops all channels …
Enumerationr/w
Enumerated Values:
1b1only
2b2only
3all
.1.3.6.1.4.1.1570.1.6.3.1.4
frxStartTest mandatory
This parameter is used to start and stop the test.
frxTestPort, frxTestType, frxLoopLoc, and frxLoopCh should
be set up prior to starting the test.
1=stop test. 2=start test.
Enumerationr/w
Enumerated Values:
1stopTest
2startTest
.1.3.6.1.4.1.1570.1.6.3.1.5
frxBertRst mandatory
This parameter may be used during a LoopbackAndBert test
or a BertOnly test to reset the frxBertBE counter. It
must be returned to the normal posiion to allow errors to
be counted.
1=normal. 2=Reset BERT counter.
Enumerationr/w
Enumerated Values:
1normal
2resetBert
.1.3.6.1.4.1.1570.1.6.3.1.6
frxBertBE mandatory
BERT test block errors
RFC1155-SMICounter
Textual Convention: RFC1155-SMICounter Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.3.1.7
frxBertTestTime mandatory
BERT test time in 0.01 second increments
RFC1155-SMITimeTicks
Textual Convention: RFC1155-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.1570.1.6.3.1.8
frxTestInProg mandatory
Test in progress (1); Normal operation (2)
Enumeration
Enumerated Values:
1testInProgress
2normalOperation
.1.3.6.1.4.1.1570.1.6.3.1.9

frxUThrTable

table mandatory
.1.3.6.1.4.1.1570.1.6.4 · 1 row entry · 7 columns
This table contains the U-interface Performance Monitoring
Thresholds and Alarms for each of the subscriber loops in
the system and for any BRITE cards extending those loops
(e.g. using Subscriber Loop Carrier systems)  The table is
indexed first using the Cisco 90 Series channel bank digroup
number, then the channel unit number (1 to 24), then the port
number (0, 1, etc) and finally the location number (the BRITE
card number (1 to 6) or 7 for local parameters in the Cisco
90 Series card). These registers are defined by Bellcore
TR-TSY-000829.
frxUThrEntry entry .1.3.6.1.4.1.1570.1.6.4.1
A specific entry in the U-interface Performance Monitoring
Threshold table. There is one entry for each port on each
Cisco 90 Series channel unit in the system and one entry for
each BRITE card extending those ports. …
Indexes
frxBankIndex frxChUIndex frxPortIndex frxPAddrIndex
Column Syntax OID
frxPAddrIndex mandatory
This is the physical location where the performance
monitoring takes place. It may be set to localFrx(7)
to access and control PM values local to the Cisco 90
Series channel unit. If there are BRITE cards in the
subscr…
Enumeration
Enumerated Values:
1briteCard1
2briteCard2
3briteCard3
4briteCard4
5briteCard5
6briteCard6
7localFrx
.1.3.6.1.4.1.1570.1.6.4.1.1
frxChEsTh mandatory
Current Hour Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
register is …
Integer32r/w
Constraints:
range: 1-3600
.1.3.6.1.4.1.1570.1.6.4.1.2
frxCdEsTh mandatory
Current Day Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
register is 0…
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.1570.1.6.4.1.3
frxChSesTh mandatory
Current Hour Severely Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
reg…
Integer32r/w
Constraints:
range: 1-3600
.1.3.6.1.4.1.1570.1.6.4.1.4
frxCdSesTh mandatory
Current Day Severely Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the corresponding bit in the frxAlertMask
regi…
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.1570.1.6.4.1.5
frxAlertMask mandatory
8-bit Alert Mask register. One bit for each threshold in
both directions. When set to 1, the corresponding threshold
crossing is ignored. When set to 0, the corresponding threshold
crossing is indicated in frxThCond an…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.1570.1.6.4.1.6
frxThCond mandatory
8-bit Threshold Condition register. One bit for each
threshold in both directions. Set to 1 if the threshold
is exceeded and the corresponding bit in the frxAlertMask
register is set to 0. Only set to 0 by the SNMP man…
Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.1570.1.6.4.1.7

frxUPerfTable

table mandatory
.1.3.6.1.4.1.1570.1.6.5 · 1 row entry · 36 columns
This table contains the U-interface Performance Monitoring
Statistics for each of the subscriber loops in the system
and for any BRITE cards extending those loops (e.g. using
Subscriber Loop Carrier systems)  The table is indexed
first using the Cisco 90 Series channel bank digroup number,
then the channel unit number (1 to 24), then the port number
(0, 1, etc) and finally the location number (the BRITE card
number (1 to 6) or 7 for local parameters in the Cisco 90
Series card). These registers are defined by Bellcore
TR-TSY-000829.
frxUPerfEntry entry .1.3.6.1.4.1.1570.1.6.5.1
A specific entry in the U-interface Performance Monitoring
Statistics table. There is one entry for each port on each
Cisco 90 Series channel unit in the system and one entry for
each BRITE card extending those ports. …
Indexes
frxBankIndex frxChUIndex frxPortIndex frxPAddrIndex
Column Syntax OID
frxResetPM mandatory
Reset all of the performance monitoring statistics on the
specified Cisco 90 Series channel unit or BRITE card.
1=Normal. 2=Reset. There is no need to set this register
back to Normal after doing a reset.
Enumerationr/w
Enumerated Values:
1normal
2resetPM
.1.3.6.1.4.1.1570.1.6.5.1.1
frxPMtype mandatory
Determines if the Cisco 90 Series channel unit or the downstream
BRITE cards is doing segmented or path performance monitoring as
specified in Bellcore document TR-NWT-000397. Only segmented
performance monitoring shou…
Enumeration
Enumerated Values:
1segmentedPM
2pathPM
.1.3.6.1.4.1.1570.1.6.5.1.2
frxChEsTx mandatory
Current Hour Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.3
frxChEsRx mandatory
Current Hour Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
li…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.4
frxPhEsTx mandatory
Previous Hour Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.5
frxPhEsRx mandatory
Previous Hour Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
l…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.6
frxH2EsTx mandatory
Errored Seconds 2 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
l…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.7
frxH2EsRx mandatory
Errored Seconds 2 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
lin…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.8
frxH3EsTx mandatory
Errored Seconds 3 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
l…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.9
frxH3EsRx mandatory
Errored Seconds 3 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
lin…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.10
frxH4EsTx mandatory
Errored Seconds 4 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
l…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.11
frxH4EsRx mandatory
Errored Seconds 4 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
lin…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.12
frxH5EsTx mandatory
Errored Seconds 5 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
l…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.13
frxH5EsRx mandatory
Errored Seconds 5 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
lin…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.14
frxH6EsTx mandatory
Errored Seconds 6 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
l…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.15
frxH6EsRx mandatory
Errored Seconds 6 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
lin…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.16
frxH7EsTx mandatory
Errored Seconds 7 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
l…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.17
frxH7EsRx mandatory
Errored Seconds 7 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
lin…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.18
frxH8EsTx mandatory
Errored Seconds 8 hours ago - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
l…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.19
frxH8EsRx mandatory
Errored Seconds 8 hours ago - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
lin…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.20
frxCdEsTx mandatory
Current Day Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
l…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.21
frxCdEsRx mandatory
Current Day Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
lin…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.22
frxPdEsTx mandatory
Previous Day Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.23
frxPdEsRx mandatory
Previous Day Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Errored Seconds are seconds in which one or more block
errors occur. These errors are measured at the physical
li…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.24
frxChSesTx mandatory
Current Hour Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measu…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.25
frxChSesRx mandatory
Current Hour Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measure…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.26
frxPhSesTx mandatory
Previous Hour Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are meas…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.27
frxPhSesRx mandatory
Previous Hour Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measur…
Integer32
Constraints:
range: 0-3600
.1.3.6.1.4.1.1570.1.6.5.1.28
frxCdSesTx mandatory
Current Day Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measur…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.29
frxCdSesRx mandatory
Current Day Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measured…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.30
frxPdSesTx mandatory
Previous Day Severely Errored Seconds - Transmit direction.
Transmit is data from the network towards the customer.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measu…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.31
frxPdSesRx mandatory
Previous Day Severely Errored Seconds - Receive direction.
Receive is data from the customer towards the network.
Severely Errored Seconds are seconds in which three or more
block errors occur. These errors are measure…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.32
frxChBeTx mandatory
Current Hour Block Errors - Transmit direction.
Transmit is data from the network towards the customer.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
The…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.33
frxChBeRx mandatory
Current Hour Block Errors - Receive direction.
Receive is data from the customer towards the network.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
These…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.34
frxPhBeTx mandatory
Previous Hour Block Errors - Transmit direction.
Transmit is data from the network towards the customer.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
Th…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.35
frxPhBeRx mandatory
Previous Hour Block Errors - Receive direction.
Receive is data from the customer towards the network.
Block errors are 12 millisecond time periods in which a
physical link level (e.g. DSL CRC or BPV) error occurs.
Thes…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.1570.1.6.5.1.36