frxTestType
Cisco90Series-MIB ·
.1.3.6.1.4.1.1570.1.6.3.1.2
Object
column
mandatory
r/w
Enumeration
This parameter indicates the type of test to perform. It has no effect until frxStartTest is set to start the test. 1=Set up a loopback and run a PN-2047 Bit Error Rate Test. 2=Run a (straightaway) PN-2047 Bit Error Rate Test. This test assumes a loopback has been manually set up somewhere downstream or another test set running PN-2047 BERT is connected downstream. 3=Send corrupted CRC on the DSL. This has no effect on the frame relay CRC, only the out-of-band DSL CRC (used for performance monitoring) is corrupted. 4=Set up a loopback at the specified location to loop the frame relay or PPP data in both directions. 5=Setup a local loopback on all 4 ports. frxTestPort and frxLoopLoc are ignored for this test.
Context
- MIB
- Cisco90Series-MIB
- OID
.1.3.6.1.4.1.1570.1.6.3.1.2- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- frxUEocEntry
- Table
- frxUEocTable
- Siblings
- 8
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | loopbackAndBert |
2 | bertOnly |
3 | sendCorruptCRC |
4 | loopbackOnly |
5 | localLoopAllPorts |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| frxTestPort mandatory This parameter indicates which subscriber port on the
channel unit to test. It has no effect until frxStartTest
is set to start the test. Only one port on a given channel
unit may… | column | Integer32 | .1.3.6.1.4.1.1570.1.6.3.1.1 |
| frxLoopLoc mandatory This parameter indicates the location of the loopback or
the card that will send corrupt CRC. It has no effect
until frxStartTest is set to start the test. It has no
effect for a… | column | Enumeration | .1.3.6.1.4.1.1570.1.6.3.1.3 |
| frxLoopCh mandatory This parameter indicates which channels to use for the
loopbackOnly and localLoopAllPorts test. It has no effect
until frxStartTest is set to start the test. Note that the
loopbac… | column | Enumeration | .1.3.6.1.4.1.1570.1.6.3.1.4 |
| frxStartTest mandatory This parameter is used to start and stop the test.
frxTestPort, frxTestType, frxLoopLoc, and frxLoopCh should
be set up prior to starting the test.
1=stop test. 2=start test. | column | Enumeration | .1.3.6.1.4.1.1570.1.6.3.1.5 |
| frxBertRst mandatory This parameter may be used during a LoopbackAndBert test
or a BertOnly test to reset the frxBertBE counter. It
must be returned to the normal posiion to allow errors to
be counted… | column | Enumeration | .1.3.6.1.4.1.1570.1.6.3.1.6 |
| frxBertBE mandatory BERT test block errors | column | RFC1155-SMICounter | .1.3.6.1.4.1.1570.1.6.3.1.7 |
| frxBertTestTime mandatory BERT test time in 0.01 second increments | column | RFC1155-SMITimeTicks | .1.3.6.1.4.1.1570.1.6.3.1.8 |
| frxTestInProg mandatory Test in progress (1); Normal operation (2) | column | Enumeration | .1.3.6.1.4.1.1570.1.6.3.1.9 |