frxUEocEntry
Cisco90Series-MIB ·
.1.3.6.1.4.1.1570.1.6.3.1
Object
row
mandatory
A specific entry in the Cisco 90 Series Embedded Operations Channel Table. There is one entry for each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots
Context
- MIB
- Cisco90Series-MIB
- OID
.1.3.6.1.4.1.1570.1.6.3.1- Type
- row
- Status
- mandatory
- Parent
- frxUEocTable
- Table
- frxUEocTable
- Children
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| frxTestPort mandatory This parameter indicates which subscriber port on the
channel unit to test. It has no effect until frxStartTest
is set to start the test. Only one port on a given channel
unit may… | column | Integer32 | .1.3.6.1.4.1.1570.1.6.3.1.1 |
| frxTestType mandatory This parameter indicates the type of test to perform. It
has no effect until frxStartTest is set to start the test.
1=Set up a loopback and run a PN-2047 Bit Error Rate Test.
2=Ru… | column | Enumeration | .1.3.6.1.4.1.1570.1.6.3.1.2 |
| frxLoopLoc mandatory This parameter indicates the location of the loopback or
the card that will send corrupt CRC. It has no effect
until frxStartTest is set to start the test. It has no
effect for a… | column | Enumeration | .1.3.6.1.4.1.1570.1.6.3.1.3 |
| frxLoopCh mandatory This parameter indicates which channels to use for the
loopbackOnly and localLoopAllPorts test. It has no effect
until frxStartTest is set to start the test. Note that the
loopbac… | column | Enumeration | .1.3.6.1.4.1.1570.1.6.3.1.4 |
| frxStartTest mandatory This parameter is used to start and stop the test.
frxTestPort, frxTestType, frxLoopLoc, and frxLoopCh should
be set up prior to starting the test.
1=stop test. 2=start test. | column | Enumeration | .1.3.6.1.4.1.1570.1.6.3.1.5 |
| frxBertRst mandatory This parameter may be used during a LoopbackAndBert test
or a BertOnly test to reset the frxBertBE counter. It
must be returned to the normal posiion to allow errors to
be counted… | column | Enumeration | .1.3.6.1.4.1.1570.1.6.3.1.6 |
| frxBertBE mandatory BERT test block errors | column | RFC1155-SMICounter | .1.3.6.1.4.1.1570.1.6.3.1.7 |
| frxBertTestTime mandatory BERT test time in 0.01 second increments | column | RFC1155-SMITimeTicks | .1.3.6.1.4.1.1570.1.6.3.1.8 |
| frxTestInProg mandatory Test in progress (1); Normal operation (2) | column | Enumeration | .1.3.6.1.4.1.1570.1.6.3.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| frxBankIndex mandatory Channel Bank Di-group Number. This index is used to address
the various channel banks in the system. This number is the
same as the DLCI number used to communicate with the bank a… | column | Integer32 | .1.3.6.1.4.1.1570.1.3.1.1.1 |
| frxChUIndex mandatory Channel Unit Number. This index is used to address a
specific channel unit in a bank. For D4 channel banks
this number is the same as the physical slot number 1-24 | column | Integer32 | .1.3.6.1.4.1.1570.1.4.1.1.1 |