frxThCond

Cisco90Series-MIB · .1.3.6.1.4.1.1570.1.6.4.1.7

Object

column mandatory r/w Integer32
8-bit Threshold Condition register. One bit for each
threshold in both directions.  Set to 1 if the threshold
is exceeded and the corresponding bit in the frxAlertMask
register is set to 0. Only set to 0 by the SNMP manager.
     1  Current Day Severely Errored Seconds Receive
     2  Current Day Severely Errored Seconds Transmit
     4  Current Day Errored Seconds Receive
     8  Current Day Errored Seconds Receive
    16  Current Hour Severely Errored Seconds Receive
    32  Current Hour Severely Errored Seconds Transmit
    64  Current Hour Errored Seconds Receive
   128  Current Hour Errored Seconds Transmit
Receive is data from the customer towards the network.
Transmit is data from the network towards the Customer.
SNMP manager should reset bits to 0 after they it has been
read by issuing a set using the inverted byte read. Sets
will only reset bits where the set data is a 0.  Setting
a bit to a 1 has no effect.  This register is defined
by Bellcore TR-TSY-000829.  In the spirit of SNMP, the bits
are inverted when read relative to that specification so
the sense of the bits is the same for sets and gets.
Indexed by Bank.ChannelUnit.Port.Address

Context

MIB
Cisco90Series-MIB
OID
.1.3.6.1.4.1.1570.1.6.4.1.7
Type
column
Access
readwrite
Status
mandatory
Parent
frxUThrEntry
Table
frxUThrTable
Siblings
6

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-255

Related Objects

Sibling Objects