frxThCond
Cisco90Series-MIB ·
.1.3.6.1.4.1.1570.1.6.4.1.7
Object
column
mandatory
r/w
Integer32
8-bit Threshold Condition register. One bit for each
threshold in both directions. Set to 1 if the threshold
is exceeded and the corresponding bit in the frxAlertMask
register is set to 0. Only set to 0 by the SNMP manager.
1 Current Day Severely Errored Seconds Receive
2 Current Day Severely Errored Seconds Transmit
4 Current Day Errored Seconds Receive
8 Current Day Errored Seconds Receive
16 Current Hour Severely Errored Seconds Receive
32 Current Hour Severely Errored Seconds Transmit
64 Current Hour Errored Seconds Receive
128 Current Hour Errored Seconds Transmit
Receive is data from the customer towards the network.
Transmit is data from the network towards the Customer.
SNMP manager should reset bits to 0 after they it has been
read by issuing a set using the inverted byte read. Sets
will only reset bits where the set data is a 0. Setting
a bit to a 1 has no effect. This register is defined
by Bellcore TR-TSY-000829. In the spirit of SNMP, the bits
are inverted when read relative to that specification so
the sense of the bits is the same for sets and gets.
Indexed by Bank.ChannelUnit.Port.Address
Context
- MIB
- Cisco90Series-MIB
- OID
.1.3.6.1.4.1.1570.1.6.4.1.7- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- frxUThrEntry
- Table
- frxUThrTable
- Siblings
- 6
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| frxPAddrIndex mandatory This is the physical location where the performance
monitoring takes place. It may be set to localFrx(7)
to access and control PM values local to the Cisco 90
Series channel unit… | column | Enumeration | .1.3.6.1.4.1.1570.1.6.4.1.1 |
| frxChEsTh mandatory Current Hour Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the correspond… | column | Integer32 | .1.3.6.1.4.1.1570.1.6.4.1.2 |
| frxCdEsTh mandatory Current Day Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the correspondi… | column | Integer32 | .1.3.6.1.4.1.1570.1.6.4.1.3 |
| frxChSesTh mandatory Current Hour Severely Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the c… | column | Integer32 | .1.3.6.1.4.1.1570.1.6.4.1.4 |
| frxCdSesTh mandatory Current Day Severely Errored Seconds threshold. This
threshold is used for both the transmit and receive
directions. When errors are detected that exceed this
threshold and the co… | column | Integer32 | .1.3.6.1.4.1.1570.1.6.4.1.5 |
| frxAlertMask mandatory 8-bit Alert Mask register. One bit for each threshold in
both directions. When set to 1, the corresponding threshold
crossing is ignored. When set to 0, the corresponding thresho… | column | Integer32 | .1.3.6.1.4.1.1570.1.6.4.1.6 |