frxMgtN392
Cisco90Series-MIB ·
.1.3.6.1.4.1.1570.1.5.1.1.5
Object
column
mandatory
r/w
Integer32
When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the network is declared inactive. This is the Annex-D N392 parameter (Typical value 3)
Context
- MIB
- Cisco90Series-MIB
- OID
.1.3.6.1.4.1.1570.1.5.1.1.5- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- frxMgtEntry
- Table
- frxMgtTable
- Siblings
- 9
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-10
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| frxPortsInSvc mandatory Ports in service. The number of ports on a Cisco 90 Series
channel unit that have one or more active PVCs, as determined
by Annex-D. | column | Integer32 | .1.3.6.1.4.1.1570.1.5.1.1.1 |
| frxNetChStatus mandatory Current status of the Annex-D signaling channel on
the network side of the channel bank. | column | Enumeration | .1.3.6.1.4.1.1570.1.5.1.1.10 |
| frxMgtT391 mandatory This controls how often (in seconds) the channel unit
sends an Annex-D poll to the frame relay switch.
This is the Annex-D T391 parameter (Typical value 10) | column | Integer32 | .1.3.6.1.4.1.1570.1.5.1.1.2 |
| frxMgtT392 mandatory This controls how long (in seconds) the channel unit
will wait for a subscriber to send it an Annex-D poll
before declaring a link error from the subscriber.
This is the Annex-D T… | column | Integer32 | .1.3.6.1.4.1.1570.1.5.1.1.3 |
| frxMgtN391 mandatory This controls how often (in polls) the channel unit
sends a full status inquiry poll to the frame relay
switch instead of a link integrity verification poll.
This is the Annex-D N… | column | Integer32 | .1.3.6.1.4.1.1570.1.5.1.1.4 |
| frxMgtN393 mandatory When more than frxMgtN392 errors are detected in any
frxMgtN393 monitored Annex-D events, the network is
declared inactive. This is the Annex-D N393 parameter
(Typical value 4) | column | Integer32 | .1.3.6.1.4.1.1570.1.5.1.1.6 |
| frxNetLinkErrors mandatory Number of signaling link reliability errors from
network. A signaling reliability error is declared
whenever the channel units did not receive a reply
from the frame relay switch… | column | RFC1155-SMICounter | .1.3.6.1.4.1.1570.1.5.1.1.7 |
| frxNetProtErrors mandatory Number of signaling protocol errors from network.
A signaling protocol error is declared whenever
the channel units receive a reply with incorrect
format or sequence numbers from … | column | RFC1155-SMICounter | .1.3.6.1.4.1.1570.1.5.1.1.8 |
| frxNetChInactive mandatory Number of times network Annex-D signaling channel
was declared inactive. | column | RFC1155-SMICounter | .1.3.6.1.4.1.1570.1.5.1.1.9 |