CPS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
76
Rows
76
Columns
482
.1.3.6.1.4.1.3808.1.1.1.5.1.2 · 1 row entry · 4 columns
A list of equipment plugged into the UPS.
The numbers of entries are given by the value of
upsBaseConfigNumDevices.
upsBaseConfigDeviceEntry entry .1.3.6.1.4.1.3808.1.1.1.5.1.2.1
The equipment plugged in to the UPS.
Indexes
deviceIndex
Column Syntax OID
deviceIndex mandatory
The index of the equipment plugged into the UPS.
Integer32
Constraints:
range: 1-255
.1.3.6.1.4.1.3808.1.1.1.5.1.2.1.1
deviceName mandatory
The name of the equipment plugged into the UPS.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.1.5.1.2.1.2
vaRating mandatory
The VA rating of the equipment plugged into the UPS.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.5.1.2.1.3
acceptThisDevice mandatory
An equipment is plugged if yes, unplugged if no.
Enumerationr/w
Enumerated Values:
1yes
2no
.1.3.6.1.4.1.3808.1.1.1.5.1.2.1.4
.1.3.6.1.4.1.3808.1.1.1.8.1.1 · 1 row entry · 2 columns
Allows for control of the outlet banks.
upsBankOutletControlEntry entry .1.3.6.1.4.1.3808.1.1.1.8.1.1.1
The outlet to control.
Indexes
upsBankControlIndex
Column Syntax OID
upsBankControlIndex mandatory
The index to the outlet entry.
Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.3808.1.1.1.8.1.1.1.1
upsBankControlOutletCommand mandatory
Getting this variable will return the outlet bank state. If
the outlet bank is on, the immediateOn (1) value will be returned.
If the outlet bank is off, the immediateOff (2) value will be
returned. If the outlet bank i…
Enumerationr/w
Enumerated Values:
1immediateOn
2immediateOff
3bankNotExist
4criticalBank
.1.3.6.1.4.1.3808.1.1.1.8.1.1.1.2
.1.3.6.1.4.1.3808.1.1.1.8.2.2 · 1 row entry · 5 columns
A table of switched outlet configuration data.
upsIndividualOutletConfigEntry entry .1.3.6.1.4.1.3808.1.1.1.8.2.2.1
Configuration data from currently queried switched outlet.
Indexes
upsIndividualOutletConfigIndex
Column Syntax OID
upsIndividualOutletConfigIndex mandatory
The index to the switched outlet configuration table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.1.8.2.2.1.1
upsIndividualOutletConfigName mandatory
The user-defined switched outlet name string.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.1.8.2.2.1.2
upsIndividualOutletConfigPowerOnTime mandatory
The amount of time (in seconds) the outlet will delay
powering on at coldstart or when a command that requires
a turn-on delay is issued.
Allowed values are:
-1 - never power on.
0 - power on immediately.
1 to 72…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.8.2.2.1.3
upsIndividualOutletConfigPowerOffTime mandatory
The amount of time (in seconds) the outlet will delay
powering off when a command that requires a
turn-off delay is issued.
Allowed values are:
-1 - never power off.
0 - power off immediately.
1 to 7200 - power o…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.8.2.2.1.4
upsIndividualOutletConfigRebootDuration mandatory
During a reboot sequence, power is turned off and then
back on. This OID defines the amount of time to wait,
in seconds, after turning the power off, at the start
of the sequence, before turning power back on, at the…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.8.2.2.1.5
.1.3.6.1.4.1.3808.1.1.1.8.2.3 · 1 row entry · 3 columns
A table of switched outlet information.
upsIndividualOutletInfoEntry entry .1.3.6.1.4.1.3808.1.1.1.8.2.3.1
Information of the currently queried switched outlet.
Indexes
upsIndividualOutletInfoIndex
Column Syntax OID
upsIndividualOutletInfoIndex mandatory
The index to the switched outlet information table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.1.8.2.3.1.1
upsIndividualOutletInfoName mandatory
The numeric switched outlet name.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.1.8.2.3.1.2
upsIndividualOutletInfoBank mandatory
The numeric bank ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.8.2.3.1.3
.1.3.6.1.4.1.3808.1.1.1.8.2.4 · 1 row entry · 4 columns
A table of switched outlet status information.
upsIndividualOutletStatusEntry entry .1.3.6.1.4.1.3808.1.1.1.8.2.4.1
Status information for currently queried switched outlet.
Indexes
upsIndividualOutletStatusIndex
Column Syntax OID
upsIndividualOutletStatusIndex mandatory
The index to the switched outlet status information table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.1.8.2.4.1.1
upsIndividualOutletStatusName mandatory
The user-defined switched outlet name string.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.1.8.2.4.1.2
upsIndividualOutletStatusState mandatory
Indicates the present switch state of the switched outlet being queried.
Enumeration
Enumerated Values:
1outletStatusOn
2outletStatusOff
.1.3.6.1.4.1.3808.1.1.1.8.2.4.1.3
upsIndividualOutletStatusCommandPending mandatory
Getting this variable will return the command pending state of the outlet.
If a command is pending on the outlet, the outletStatusCommandPending (1)
value will be returned. If there is not a command pending on the out…
Enumeration
Enumerated Values:
1outletStatusCommandPending
2outletStatusNoCommandPending
.1.3.6.1.4.1.3808.1.1.1.8.2.4.1.4
.1.3.6.1.4.1.3808.1.1.1.8.2.5 · 1 row entry · 3 columns
A table of switched outlet control data.
upsIndividualOutletControlEntry entry .1.3.6.1.4.1.3808.1.1.1.8.2.5.1
Control data for currently queried switched outlet.
Indexes
upsIndividualOutletControlIndex
Column Syntax OID
upsIndividualOutletControlIndex mandatory
The index to the switched outlet control data table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.1.8.2.5.1.1
upsIndividualOutletControlName mandatory
The user-defined switched outlet name string.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.1.8.2.5.1.2
upsIndividualOutletControlCommand mandatory
Getting this variable will return the outlet state.
If the outlet is on, the immediateOn (1) value will be returned.
If the outlet is off, the immediateOff (2) value will be returned.

Setting this vari…
Enumerationr/w
Enumerated Values:
1immediateOn
2immediateOff
3immediateReboot
4delayedOn
5delayedOff
6delayedReboot
7cancelPendingCommand
.1.3.6.1.4.1.3808.1.1.1.8.2.5.1.3

upsPhaseInputTable

table mandatory
.1.3.6.1.4.1.3808.1.1.1.9.1.2 · 1 row entry · 5 columns
Allows for getting the Phase Input in the UPS
upsPhaseInputEntry entry .1.3.6.1.4.1.3808.1.1.1.9.1.2.1
The UPS Phase Input Access.
Indexes
upsPhaseInputTableIndex
Column Syntax OID
upsPhaseInputTableIndex mandatory
The index to the UPS Phase Input entry.
Integer32
Constraints:
range: 3-3
.1.3.6.1.4.1.3808.1.1.1.9.1.2.1.1
upsPhaseInputVoltage mandatory
Getting this OID will return the input voltage that each phase of the UPS can provide. It is represented in 1/10 VAC.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.1.2.1.2
upsPhaseInputCurrent mandatory
Getting this OID will return the input current that each phase of the UPS can provide. It is represented in 1/10 Amps.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.1.2.1.3
upsPhaseInputFrequency mandatory
Getting this OID will return the input frequency that each phase of the UPS can provide. It is represented in 1/10 Hz.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.1.2.1.4
upsPhaseInputPowerFactor mandatory
Getting this OID will return the input power factor that each phase of the UPS can provide. It is represented in 1/100.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.1.2.1.5

upsPhaseOutputTable

table mandatory
.1.3.6.1.4.1.3808.1.1.1.9.2.2 · 1 row entry · 6 columns
Allows for getting the Phase Output in the UPS
upsPhaseOutputEntry entry .1.3.6.1.4.1.3808.1.1.1.9.2.2.1
The UPS Phase Output Access.
Indexes
upsPhaseOutputTableIndex
Column Syntax OID
upsPhaseOutputTableIndex mandatory
The index to the UPS Phase Output entry.
Integer32
Constraints:
range: 3-3
.1.3.6.1.4.1.3808.1.1.1.9.2.2.1.1
upsPhaseOutputVoltage mandatory
Getting this OID will return the output voltage that each phase of the UPS can provide. It is represented in 1/10 VAC.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.2.2.1.2
upsPhaseOutputCurrent mandatory
Getting this OID will return the output current that each phase of the UPS can provide. It is represented in 1/10 Amps.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.2.2.1.3
upsPhaseOutputFrequency mandatory
Getting this OID will return the output frequency that each phase of the UPS can provide. It is represented in 1/10 Hz.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.2.2.1.4
upsPhaseOutputPowerFactor mandatory
Getting this OID will return the output power factor that each phase of the UPS can provide. It is represented in 1/100.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.2.2.1.5
upsPhaseOutputPower mandatory
Getting this OID will return the output power that each phase of the UPS can provide. It is represented in Watt.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.2.2.1.6

upsPhaseBypassTable

table mandatory
.1.3.6.1.4.1.3808.1.1.1.9.3.2 · 1 row entry · 5 columns
Allows for getting the Phase Bypass in the UPS
upsPhaseBypassEntry entry .1.3.6.1.4.1.3808.1.1.1.9.3.2.1
The UPS Phase Bypass Access.
Indexes
upsPhaseBypassTableIndex
Column Syntax OID
upsPhaseBypassTableIndex mandatory
The index to the UPS Phase Bypass entry.
Integer32
Constraints:
range: 3-3
.1.3.6.1.4.1.3808.1.1.1.9.3.2.1.1
upsPhaseBypassVoltage mandatory
Getting this OID will return the bypass voltage that each phase of the UPS can provide. It is represented in 1/10 VAC.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.3.2.1.2
upsPhaseBypassCurrent mandatory
Getting this OID will return the bypass current that each phase of the UPS can provide. It is represented in 1/10 Amps.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.3.2.1.3
upsPhaseBypassFrequency mandatory
Getting this OID will return the bypass frequency that each phase of the UPS can provide. It is represented in 1/10 Hz.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.3.2.1.4
upsPhaseBypassPowerFactor mandatory
Getting this OID will return the bypass power factor that each phase of the UPS can provide. It is represented in 1/100.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.1.9.3.2.1.5

eSwitchBaseTable

table mandatory
.1.3.6.1.4.1.3808.1.1.2.2.2 · 1 row entry · 3 columns
A list of switch information. The number of entries is given
by the value of eSwitchNumber.
eSwitchBaseEntry entry .1.3.6.1.4.1.3808.1.1.2.2.2.1
An entry information of the individual switch.
Indexes
eSwitchID
Column Syntax OID
eSwitchID mandatory
The power switch ID number.
Integer32
Constraints:
range: 0-16
.1.3.6.1.4.1.3808.1.1.2.2.2.1.1
eSwitchOutletNum mandatory
The number of outlets provided in the switch.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.2.2.2.1.2
eSwitchOutletState mandatory
Getting this OID will reply the status of all outlets in the switch.
'0' for outlet off, '1' for outlet on.
The index from left to right is outlet#8, #7, #6, #5, #4, #3, #2, #1.
For Example:
If the string is '01011010',…
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.2.2.2.1.3

eSwitchBaseCtrTable

table mandatory
.1.3.6.1.4.1.3808.1.1.2.2.3 · 1 row entry · 3 columns
A list of switch control parameters. The number of entries is given
by the value of eSwitchNumber.
eSwitchBaseCtrEntry entry .1.3.6.1.4.1.3808.1.1.2.2.3.1
An entry control information of individual switches.
Indexes
eSwitchCtrID
Column Syntax OID
eSwitchCtrID mandatory
Select the switch ID to be controlled.
Integer32r/w
Constraints:
range: 0-16
.1.3.6.1.4.1.3808.1.1.2.2.3.1.1
eSwitchActOutlet mandatory
The action outlets to be controlled.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.2.2.3.1.2
eSwitchActType mandatory
The on/off type of the action outlets.
1 for duration off, 2 for duration on,
3 for immediately off, 4 for immediately on,
and 5 for reboot.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.2.2.3.1.3

ePDULoadDevBankTable

table mandatory
.1.3.6.1.4.1.3808.1.1.3.2.1.6 · 1 row entry · 3 columns
Allows for getting the Bank Max Load in the Rack PDU.
ePDULoadDevBankEntry entry .1.3.6.1.4.1.3808.1.1.3.2.1.6.1
The Rack PDU Banks Access.
Indexes
ePDULoadDevBankIndex
Column Syntax OID
ePDULoadDevBankIndex mandatory
The index to the Rack PDU bank entry.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.3.2.1.6.1.1
ePDULoadDevBankNumber mandatory
Getting this OID will return the bank number.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.1.6.1.2
ePDULoadDevBankMaxLoad mandatory
Getting this OID will return the maximum rated power
that each bank of the Rack PDU can provide. It is
represented in Amps.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.1.6.1.3
.1.3.6.1.4.1.3808.1.1.3.2.1.8 · 1 row entry · 3 columns
Allows for getting the Max Outlet Load in an Outlet Monitored Rack PDU.
ePDULoadDevMaxOutletEntry entry .1.3.6.1.4.1.3808.1.1.3.2.1.8.1
This gives access to Max Outlet Load of an Outlet Monitored Rack PDU
Indexes
ePDULoadDevOutletIndex
Column Syntax OID
ePDULoadDevOutletIndex mandatory
The index to the Outlet Monitored Rack PDU Max Outlet Load entry.
Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.3808.1.1.3.2.1.8.1.1
ePDULoadDevOutletNumber mandatory
Getting this OID will return the Outlet number.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.1.8.1.2
ePDULoadDevMaxOutletLoad mandatory
Getting this OID will return the maximum rated power
that each Outlet of an Outlet Monitored Rack PDU can provide. It is
represented in Amps.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.1.8.1.3
.1.3.6.1.4.1.3808.1.1.3.2.2.1 · 1 row entry · 5 columns
Allows for configuration of each Rack PDU phase.
The number of entries is contained in the
ePDULoadDevNumPhases OID.
ePDULoadPhaseConfigEntry entry .1.3.6.1.4.1.3808.1.1.3.2.2.1.1
The Rack PDU phase to configure.
Indexes
ePDULoadPhaseConfigIndex
Column Syntax OID
ePDULoadPhaseConfigIndex mandatory
The index to the Rack PDU phase entry.
Enumeration
Enumerated Values:
1phase1
2phase2
3phase3
.1.3.6.1.4.1.3808.1.1.3.2.2.1.1.1
ePDULoadPhaseConfigLowLoadThreshold mandatory
A threshold that indicates the power consumption of
the load is nearing a low consumption condition. It is
represented in Amps. A warning will be issued when the
load is less than the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.2.1.1.2
ePDULoadPhaseConfigNearOverloadThreshold mandatory
A threshold that indicates the power consumption of
the load is nearing an overload condition. It is
represented in Amps. A warning will be issued when the
load is greater than or equal to the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.2.1.1.3
ePDULoadPhaseConfigOverloadThreshold mandatory
A threshold that indicates the power consumption of
the load has entered an overload condition. It is
represented in Amps. A warning will be issued when the
load is greater than or equal to the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.2.1.1.4
ePDULoadPhaseConfigAlarm mandatory
Getting this OID will return the current Phase Alarm.
Enumeration
Enumerated Values:
1noLoadAlarm
2underCurrentAlarm
3nearOverCurrentAlarm
4overCurrentAlarm
.1.3.6.1.4.1.3808.1.1.3.2.2.1.1.5

ePDULoadStatusTable

table mandatory
.1.3.6.1.4.1.3808.1.1.3.2.3.1 · 1 row entry · 11 columns
Allows for getting of status of each Rack PDU phase/bank.
The number of entries is calculated by adding
the number of phases (ePDULoadDevNumPhases OID) and
the number of banks of outlets (ePDULoadDevNumBanks)
Number of entries = #phases + #banks.
NOTE: If a device has phase and bank information, all phase information
shall precede the bank information.
ePDULoadStatusEntry entry .1.3.6.1.4.1.3808.1.1.3.2.3.1.1
The Rack PDU phase/bank to gather status from.
Indexes
ePDULoadStatusIndex
Column Syntax OID
ePDULoadStatusIndex mandatory
The index to the Rack PDU phase/bank entry. All phase information will precede
any bank information
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.3.2.3.1.1.1
ePDULoadStatusLoad mandatory
Getting this OID will return the phase/bank load measured
in tenths of Amps.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.3.2.3.1.1.2
ePDULoadStatusLoadState mandatory
Getting this OID will return the phase/bank load state.

loadNormal(1) indicates that the phase/bank is operating
properly within the ePDULoadConfigLowLoadThreshold
and ePDULoadConfigNearOverloadThreshol…
Enumeration
Enumerated Values:
1loadNormal
2loadLow
3loadNearOverload
4loadOverload
.1.3.6.1.4.1.3808.1.1.3.2.3.1.1.3
ePDULoadStatusPhaseNumber mandatory
The phase number to which this record refers.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.3.1.1.4
ePDULoadStatusBankNumber mandatory
The bank number to which this record refers. A value of 0 will be returned if
any bank is not present or if it is phase related.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.3.1.1.5
ePDULoadStatusVoltage mandatory
Getting this OID will return the phase/bank voltage measured
in 0.1 volts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.3.1.1.6
ePDULoadStatusActivePower mandatory
Getting this OID will return the phase/bank active power measured
in watts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.3.1.1.7
ePDULoadStatusApparentPower mandatory
Getting this OID will return the phase/bank apparent power measured
in VA.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.3.1.1.8
ePDULoadStatusPowerFactor mandatory
Getting this OID will return power factor of the output measured in hundredths.
A value of 100 representing a unity power factor (1.00).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.3.1.1.9
ePDULoadStatusEnergy mandatory
Getting this OID will return the phase/bank apparent power measured
in 0.1 kilowatt-hours.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.3.1.1.10
ePDULoadStatusEnergyStartTime mandatory
Getting this OID will return the date and time of the last energy
meter reset
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.3.2.3.1.1.11
.1.3.6.1.4.1.3808.1.1.3.2.4.1 · 1 row entry · 5 columns
Allows for configuration of each Rack PDU bank.
The number of entries is contained in the 
ePDULoadDevNumBanks OID.
ePDULoadBankConfigEntry entry .1.3.6.1.4.1.3808.1.1.3.2.4.1.1
The Rack PDU bank to configure.
Indexes
ePDULoadBankConfigIndex
Column Syntax OID
ePDULoadBankConfigIndex mandatory
The index to the Rack PDU bank entry.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.3.2.4.1.1.1
ePDULoadBankConfigLowLoadThreshold mandatory
A threshold that indicates the power consumption of
the load is nearing a low consumption condition. It is
represented in Amps. A warning will be issued when the
load is less than the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.4.1.1.2
ePDULoadBankConfigNearOverloadThreshold mandatory
A threshold that indicates the power consumption of
the load is nearing an overload condition. It is
represented in Amps. A warning will be issued when the
load is greater than or equal to the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.4.1.1.3
ePDULoadBankConfigOverloadThreshold mandatory
A threshold that indicates the power consumption of
the load has entered an overload condition. It is
represented in Amps. A warning will be issued when the
load is greater than or equal to the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.2.4.1.1.4
ePDULoadBankConfigAlarm mandatory
Getting this OID will return the current Bank Alarm.
Enumeration
Enumerated Values:
1noLoadAlarm
2underCurrentAlarm
3nearOverCurrentAlarm
4overCurrentAlarm
.1.3.6.1.4.1.3808.1.1.3.2.4.1.1.5

ePDUOutletPhaseTable

table mandatory
.1.3.6.1.4.1.3808.1.1.3.3.2.1 · 1 row entry · 2 columns
Allows for management of outlets on a per phase basis.
ePDUOutletPhaseEntry entry .1.3.6.1.4.1.3808.1.1.3.3.2.1.1
The phase to manage.
Indexes
ePDUOutletPhaseIndex
Column Syntax OID
ePDUOutletPhaseIndex mandatory
The index to the Switched Rack PDU phase entry.
Enumeration
Enumerated Values:
1phase1
2phase2
3phase3
.1.3.6.1.4.1.3808.1.1.3.3.2.1.1.1
ePDUOutletPhaseOverloadRestriction mandatory
This OID controls the behavior of a Switched Rack PDU
phase when an overload condition is possible and
additional outlets are requested to be turned on.

Setting this OID to alwaysAllowTurnON (1) will al…
Enumerationr/w
Enumerated Values:
1alwaysAllowTurnON
2restrictOnNearOverload
3restrictOnOverload
.1.3.6.1.4.1.3808.1.1.3.3.2.1.1.2

ePDUOutletControlTable

table mandatory
.1.3.6.1.4.1.3808.1.1.3.3.3.1 · 1 row entry · 5 columns
Allows for control of the individual outlets.
The number of entries is contained in the 
ePDUOutletDevNumCntrlOutlets OID.
ePDUOutletControlEntry entry .1.3.6.1.4.1.3808.1.1.3.3.3.1.1
The outlet to control.
Indexes
ePDUOutletControlIndex
Column Syntax OID
ePDUOutletControlIndex mandatory
The index to the outlet entry.
Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.3808.1.1.3.3.3.1.1.1
ePDUOutletControlOutletName mandatory
The name of the outlet. The maximum string size is device dependent.
An error will be returned if the set request exceeds the max size.
This OID is provided for informational purposes only.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.3.3.3.1.1.2
ePDUOutletControlOutletPhase mandatory
The phase/s associated with this outlet.

For single phase devices, this object will always
return phase1(1).

For 3-phase devices, this object will return phase1 (1),
phase2 (2), or phase3…
Enumeration
Enumerated Values:
1phase1
2phase2
3phase3
4phase1-2
5phase2-3
6phase3-1
.1.3.6.1.4.1.3808.1.1.3.3.3.1.1.3
ePDUOutletControlOutletCommand mandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOn (1) value will be returned.
If the outlet is off, the immediateOff (2) value will be
returned.


Set…
Enumerationr/w
Enumerated Values:
1immediateOn
2immediateOff
3immediateReboot
4delayedOn
5delayedOff
6delayedReboot
7cancelPendingCommand
8outletIdentify
.1.3.6.1.4.1.3808.1.1.3.3.3.1.1.4
ePDUOutletControlOutletBank mandatory
The bank associated with this outlet.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.3.3.1.1.5

ePDUOutletConfigTable

table mandatory
.1.3.6.1.4.1.3808.1.1.3.3.4.1 · 1 row entry · 7 columns
Allows for configuration of individual outlets. The number of
entries is contained in the ePDUOutletDevNumCntrlOutlets OID.
ePDUOutletConfigEntry entry .1.3.6.1.4.1.3808.1.1.3.3.4.1.1
The outlet to configure.
Indexes
ePDUOutletConfigIndex
Column Syntax OID
ePDUOutletConfigIndex mandatory
The index to the outlet entry.
Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.3808.1.1.3.3.4.1.1.1
ePDUOutletConfigOutletName mandatory
The name of the outlet. The maximum string size is device dependent.
An error will be returned if the set request exceeds the max size.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.3.3.4.1.1.2
ePDUOutletConfigOutletPhase mandatory
The phase/s associated with this outlet.

For single phase devices, this object will always
return phase1(1).

For 3-phase devices, this object will return phase1 (1),
phase2 (2), or phase3…
Enumeration
Enumerated Values:
1phase1
2phase2
3phase3
4phase1-2
5phase2-3
6phase3-1
.1.3.6.1.4.1.3808.1.1.3.3.4.1.1.3
ePDUOutletConfigPowerOnTime mandatory
The amount of time (in seconds) the outlet will delay
powering on at coldstart or when a command that requires
a turn-on delay is issued.

Allowed values are:

-1 - never powe…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.3.4.1.1.4
ePDUOutletConfigPowerOffTime mandatory
The amount of time (in seconds) the outlet will delay
powering off when a command that requires
a turn-off delay is issued.

Allowed values are:

-1 - never power off.
0 - po…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.3.4.1.1.5
ePDUOutletConfigRebootDuration mandatory
During a reboot sequence, power is turned off and then
back on. This OID defines the amount of time to wait,
in seconds, after turning the power off, at the start
of the sequence, before turning power back on, at the
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.3.4.1.1.6
ePDUOutletConfigOutletBank mandatory
The bank associated with this outlet.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.3.4.1.1.7
.1.3.6.1.4.1.3808.1.1.3.3.4.3 · 1 row entry · 8 columns
Allows for getting/setting of outlet thresholds of an Outlet Monitored Rack PDU.
ePDUOutletConfigMonitoredEntry entry .1.3.6.1.4.1.3808.1.1.3.3.4.3.1
This gives access to Monitored Outlet entries
Indexes
ePDUOutletConfigMonitoredIndex
Column Syntax OID
ePDUOutletConfigMonitoredIndex mandatory
The index to the RACK PDU Phase entry.
Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.3808.1.1.3.3.4.3.1.1
ePDUOutletConfigMonitoredName mandatory
The name of the Monitored Outlet. The maximum string size is device dependent.
An error will be returned if the set request exceeds the max size.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.3.3.4.3.1.2
ePDUOutletConfigMonitoredNumber mandatory
The outlet number of an Outlet Monitored RACK PDU.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.3.4.3.1.3
ePDUOutletConfigMonitoredLowLoadThreshold mandatory
A threshold that indicates the power consumption of
the load is nearing a low consumption condition. It is
represented in watts. A warning will be issued when
the load is less than the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.3.4.3.1.4
ePDUOutletConfigMonitoredNearOverloadThreshold mandatory
A threshold that indicates the power consumption of
the load is nearing an overload condition. It is
represented in watts. A warning
will be issued when the load is greater than or equal
to the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.3.4.3.1.5
ePDUOutletConfigMonitoredOverloadThreshold mandatory
A threshold that indicates the power consumption of
the load has entered an overload condition. It is
represented in watts. A warning
will be issued when the load is greater than or equal
to the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.3.4.3.1.6
ePDUOutletConfigMonitoredPeakLoadReset mandatory
Setting this OID to reset (2) will cause the existing peak power value
to be replaced by the current load power value.

Getting this oid will do nothing and return noAction (1) if the PDU
support this fe…
Enumerationr/w
Enumerated Values:
1noAction
2reset
3notSupport
.1.3.6.1.4.1.3808.1.1.3.3.4.3.1.7
ePDUOutletConfigMonitoredEnergyReset mandatory
Setting this OID to reset (2) will cause the device energy meter value
to be reset to zero.

Getting this oid will do nothing and return noAction (1) if the PDU
support this feature, return notSupport (3…
Enumerationr/w
Enumerated Values:
1noAction
2reset
3notSupport
.1.3.6.1.4.1.3808.1.1.3.3.4.3.1.8

ePDUOutletStatusTable

table mandatory
.1.3.6.1.4.1.3808.1.1.3.3.5.1 · 1 row entry · 14 columns
Allows for getting of status of individual outlets. The number of
entries is contained in the ePDUOutletDevNumCntrlOutlets OID.
ePDUOutletStatusEntry entry .1.3.6.1.4.1.3808.1.1.3.3.5.1.1
The outlet to gather status from.
Indexes
ePDUOutletStatusIndex
Column Syntax OID
ePDUOutletStatusIndex mandatory
The index to the outlet entry.
Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.1
ePDUOutletStatusOutletName mandatory
The name of the outlet. The maximum string size is device dependent.
This OID is provided for informational purposes only.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.2
ePDUOutletStatusOutletPhase mandatory
The phase/s associated with this outlet.

For single phase devices, this object will always
return phase1(1).

For 3-phase devices, this object will return phase1 (1),
phase2 (2), or phase3…
Enumeration
Enumerated Values:
1phase1
2phase2
3phase3
4phase1-2
5phase2-3
6phase3-1
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.3
ePDUOutletStatusOutletState mandatory
Getting this variable will return the outlet state. If
the outlet is on, the outletStatusOn (1) value will be returned.
If the outlet is off, the outletStatusOff (2) value will be
returned.
Enumeration
Enumerated Values:
1outletStatusOn
2outletStatusOff
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.4
ePDUOutletStatusCommandPending mandatory
Getting this variable will return the command pending
state of the outlet. If a command is pending on the
outlet, the outletStatusCommandPending (1) value
will be returned. If there is not a command pending
on the outl…
Enumeration
Enumerated Values:
1outletStatusCommandPending
2outletStatusNoCommandPending
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.5
ePDUOutletStatusOutletBank mandatory
The bank associated with this outlet.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.6
ePDUOutletStatusLoad mandatory
Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU
in tenths of Amps.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.7
ePDUOutletStatusActivePower mandatory
Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU
in watts
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.8
ePDUOutletStatusAlarm mandatory
Getting this OID will return the current outlet alarm
Enumeration
Enumerated Values:
1noLoadAlarm
2underCurrentAlarm
3nearOverCurrentAlarm
4overCurrentAlarm
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.9
ePDUOutletStatusPeakPower mandatory
The peak power consumption of the Rack PDU load in watts.
This value can be reset by setting the oid
ePDUOutletConfigMonitoredPeakLoadReset to reset (2)
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.10
ePDUOutletStatusPeakPowerTime mandatory
Get this oid shows the date and time that peak power consumption occurred
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.11
ePDUOutletStatusPeakPowerStart mandatory
Get this oid shows the date and time that peak power consumption started
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.12
ePDUOutletStatusEnergy mandatory
Energy meter measuring Rack PDU load energy consumption
in tenths of kilowatt-hours. This value can be reset by setting
the oid ePDUOutletConfigMonitoredEnergyReset to reset (2)
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.13
ePDUOutletStatusEnergyStartTime mandatory
Indicates the date and time of the last device energy
meter reset
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.14

ePDUOutletBankTable

table mandatory
.1.3.6.1.4.1.3808.1.1.3.3.6.1 · 1 row entry · 2 columns
Allows for management of outlets on a per bank basis.
ePDUOutletBankEntry entry .1.3.6.1.4.1.3808.1.1.3.3.6.1.1
The bank to manage.
Indexes
ePDUOutletBankIndex
Column Syntax OID
ePDUOutletBankIndex mandatory
The index to the Switched Rack PDU bank entry.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.3.3.6.1.1.1
ePDUOutletBankOverloadRestriction mandatory
This OID controls the behavior of a Switched Rack PDU
bank when an overload condition is possible and
additional outlets are requested to be turned on.

Setting this OID to alwaysAllowTurnON (1) will al…
Enumerationr/w
Enumerated Values:
1alwaysAllowTurnON
2restrictOnNearOverload
3restrictOnOverload
.1.3.6.1.4.1.3808.1.1.3.3.6.1.1.2

ePDUStatusBankTable

table mandatory
.1.3.6.1.4.1.3808.1.1.3.5.2 · 1 row entry · 3 columns
Allows for getting of status of each Rack PDU Bank
ePDUStatusBankEntry entry .1.3.6.1.4.1.3808.1.1.3.5.2.1
This gives access to Bank entries
Indexes
ePDUStatusBankIndex
Column Syntax OID
ePDUStatusBankIndex mandatory
The index to the RACK PDU Bank entry.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.3.5.2.1.1
ePDUStatusBankNumber mandatory
Getting this OID will return the bank number.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.5.2.1.2
ePDUStatusBankState mandatory
Getting this OID will return the bank load state.

bankLoadNormal(1) indicates that the bank is
operating properly within the ePDULoadBankConfigLowLoadThreshold
and ePDULoadBankConfigNearOverloadThreshol…
Enumeration
Enumerated Values:
1bankLoadNormal
2bankLoadLow
3bankLoadNearOverload
4bankLoadOverload
.1.3.6.1.4.1.3808.1.1.3.5.2.1.3

ePDUStatusPhaseTable

table mandatory
.1.3.6.1.4.1.3808.1.1.3.5.4 · 1 row entry · 3 columns
Allows for getting of status of each Rack PDU Phase
ePDUStatusPhaseEntry entry .1.3.6.1.4.1.3808.1.1.3.5.4.1
This gives access to Phase entries
Indexes
ePDUStatusPhaseIndex
Column Syntax OID
ePDUStatusPhaseIndex mandatory
The index to the RACK PDU Phase entry.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.3.5.4.1.1
ePDUStatusPhaseNumber mandatory
Getting this OID will return the phase number.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.5.4.1.2
ePDUStatusPhaseState mandatory
Getting this OID will return the Phase load state.

phaseLoadNormal(1) indicates that the Phase is
operating properly within the ePDULoadPhaseConfigLowLoadThreshold
and ePDULoadPhaseConfigNearOverloadThr…
Enumeration
Enumerated Values:
1phaseLoadNormal
2phaseLoadLow
3phaseLoadNearOverload
4phaseLoadOverload
.1.3.6.1.4.1.3808.1.1.3.5.4.1.3

ePDUStatusOutletTable

table mandatory
.1.3.6.1.4.1.3808.1.1.3.5.6 · 1 row entry · 3 columns
Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU.
ePDUStatusOutletEntry entry .1.3.6.1.4.1.3808.1.1.3.5.6.1
This gives access to Outlet entries
Indexes
ePDUStatusOutletIndex
Column Syntax OID
ePDUStatusOutletIndex mandatory
The index to the RACK PDU Outlet entry.
Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.3808.1.1.3.5.6.1.1
ePDUStatusOutletNumber mandatory
Getting this OID will return the Outlet number.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.3.5.6.1.2
ePDUStatusOutletState mandatory
Getting this OID will return the Outlet load state.

outletLoadNormal(1) indicates that the Outlet is
operating properly within the ePDUOutletConfigMonitoredLowLoadThreshold
and ePDUOutletConfigMonitored…
Enumeration
Enumerated Values:
1outletLoadNormal
2outletLoadLow
3outletLoadNearOverload
4outletLoadOverload
.1.3.6.1.4.1.3808.1.1.3.5.6.1.3

envirContactTable

table mandatory
.1.3.6.1.4.1.3808.1.1.4.4.2 · 1 row entry · 4 columns
Allows for getting of information of each contact of the environment sensor.
envirContactEntry entry .1.3.6.1.4.1.3808.1.1.4.4.2.1
This gives access to contact entries.
Indexes
envirContactIndex
Column Syntax OID
envirContactIndex mandatory
The index to the contact of the environment sensor.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.4.4.2.1.1
envirContactName mandatory
Getting or setting the name of the contact of the environment sensor.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.4.4.2.1.2
envirContactStatus mandatory
Getting this OID will return the Contact Status.
Enumeration
Enumerated Values:
1contactNormal
2contactAbnormal
.1.3.6.1.4.1.3808.1.1.4.4.2.1.3
envirContactNormalState mandatory
Set the contact normal state.
Enumerationr/w
Enumerated Values:
1normalOpen
2normalClose
.1.3.6.1.4.1.3808.1.1.4.4.2.1.4
.1.3.6.1.4.1.3808.1.1.5.2.1.10 · 1 row entry · 5 columns
A list of power supply table entries.
atsStatusPowerSupplyEntry entry .1.3.6.1.4.1.3808.1.1.5.2.1.10.1
An entry containing power supply information applicable to a
particular input.
Indexes
atsStatusPowerSupplyTableIndex
Column Syntax OID
atsStatusPowerSupplyTableIndex mandatory
The input identifier.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.5.2.1.10.1.1
atsStatusPowerSupplyInputSource mandatory
The input source to the power supply.
Enumeration
Enumerated Values:
1sourceA
2sourceB
.1.3.6.1.4.1.3808.1.1.5.2.1.10.1.2
atsStatusPowerSupply12VStatus mandatory
This variable returns the status of the power supply A 12V in system.
Enumeration
Enumerated Values:
1powerSupplyOK
2powerSupplyFailure
.1.3.6.1.4.1.3808.1.1.5.2.1.10.1.3
atsStatusPowerSupply5VStatus mandatory
This variable returns the status of the power supply A 5V in system.
Enumeration
Enumerated Values:
1powerSupplyOK
2powerSupplyFailure
.1.3.6.1.4.1.3808.1.1.5.2.1.10.1.4
atsStatusPowerSupply3p3VStatus mandatory
This variable returns the status of the power supply A 3.3V in system.
Enumeration
Enumerated Values:
1powerSupplyOK
2powerSupplyFailure
.1.3.6.1.4.1.3808.1.1.5.2.1.10.1.5

atsStatusInputTable

table mandatory
.1.3.6.1.4.1.3808.1.1.5.2.2.2 · 1 row entry · 8 columns
A list of input table entries.  The number of entries
is given by the value of atsNumInputs.
atsStatusInputEntry entry .1.3.6.1.4.1.3808.1.1.5.2.2.2.1
An entry containing information applicable to a
particular input.
Indexes
atsStatusInputTableIndex
Column Syntax OID
atsStatusInputTableIndex mandatory
The input identifier.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.5.2.2.2.1.1
atsStatusInputName mandatory
A name given to a particular input.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.5.2.2.2.1.2
atsStatusNumInputPhase mandatory
The number of input phases utilized in this device.
The sum of all the atsStatusNumInputPhase variable
indicates the number of rows in the status input
phase table.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.2.2.2.1.3
atsStatusInputVoltageOrientation mandatory
The input voltage orientation:
1: unknown for this Source
2: singlePhase - phase 1 voltage is between Phase 1
and Neutral.
3: splitPhase - phase 1 voltage is between Phase 1 and
Neutral; phase 2 voltage is between Pha…
Enumeration
Enumerated Values:
1unknown
2singlePhase
3splitPhase
4threePhasePhaseToNeutral
5threePhasePhaseToPhase
.1.3.6.1.4.1.3808.1.1.5.2.2.2.1.4
atsStatusInputVoltage mandatory
The input voltage in 0.1 Volt.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.2.2.2.1.5
atsStatusInputFrequency mandatory
The input frequency in 0.1 Hertz.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.2.2.2.1.6
atsStatusInputVolState mandatory
The input voltage status.
Enumeration
Enumerated Values:
1normal
2overVoltage
3underVoltage
.1.3.6.1.4.1.3808.1.1.5.2.2.2.1.7
atsStatusInputFreqState mandatory
The input frequency status.
Enumeration
Enumerated Values:
1normal
2overFrequency
3underFrequency
.1.3.6.1.4.1.3808.1.1.5.2.2.2.1.8
.1.3.6.1.4.1.3808.1.1.5.2.2.3 · 1 row entry · 5 columns
A list of input table entries.  The number of entries
is given by the sum of the atsNumInputPhases.
atsStatusInputPhaseEntry entry .1.3.6.1.4.1.3808.1.1.5.2.2.3.1
An entry containing information applicable to a
particular input phase.
Indexes
atsStatusInputPhaseTableIndex atsStatusInputPhaseIndex
Column Syntax OID
atsStatusInputPhaseTableIndex mandatory
The input identifier.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.5.2.2.3.1.1
atsStatusInputPhaseIndex mandatory
The input phase identifier.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.5.2.2.3.1.2
atsStatusInputPhaseVoltage mandatory
The input voltage in VAC, or -1 if it's unsupported
by this Source.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.2.2.3.1.3
atsStatusInputPhaseCurrent mandatory
The input current in amperes, or -1 if it's
unsupported by this Source.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.2.2.3.1.4
atsStatusInputPhasePower mandatory
The input power in Watts, or -1 if it's unsupported
by this Source.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.2.2.3.1.5

atsLoadDevPhaseTable

table mandatory
.1.3.6.1.4.1.3808.1.1.5.5.1.2 · 1 row entry · 3 columns
Allows for getting the Phase Max Load in the ATS.
atsLoadDevPhaseEntry entry .1.3.6.1.4.1.3808.1.1.5.5.1.2.1
The ATS Phases Access.
Indexes
atsLoadDevPhaseTableIndex
Column Syntax OID
atsLoadDevPhaseTableIndex mandatory
The index to ATS phase entry.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.5.5.1.2.1.1
atsLoadDevPhase mandatory
For single phase devices, this object will always
return phase1(1).

For 3-phase devices, this object will return phase1 (1),
phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2,
phase2-3 (5) for ph…
Enumeration
Enumerated Values:
1phase1
2phase2
3phase3
4phase1-2
5phase2-3
6phase3-1
.1.3.6.1.4.1.3808.1.1.5.5.1.2.1.2
atsLoadDevPhaseMaxLoad mandatory
Getting this OID will return the maximum rated power that each
phase of the ATS can provide. It is represented in Amps.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.1.2.1.3

atsLoadDevBankTable

table mandatory
.1.3.6.1.4.1.3808.1.1.5.5.1.4 · 1 row entry · 2 columns
Allows for getting the Bank Max Load in the ATS.
atsLoadDevBankEntry entry .1.3.6.1.4.1.3808.1.1.5.5.1.4.1
The ATS Banks Access.
Indexes
atsLoadDevBankTableIndex
Column Syntax OID
atsLoadDevBankTableIndex mandatory
The index to the ATS bank entry.
Enumeration
Enumerated Values:
1total
2bank1
3bank2
4bank3
.1.3.6.1.4.1.3808.1.1.5.5.1.4.1.1
atsLoadDevBankMaxLoad mandatory
Getting this OID will return the maximum rated power
that each bank of the ATS can provide. It is
represented in Amps.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.1.4.1.2
.1.3.6.1.4.1.3808.1.1.5.5.2.2 · 1 row entry · 5 columns
Allows for getting the Phase Load status in the ATS.
atsLoadStatusPhaseEntry entry .1.3.6.1.4.1.3808.1.1.5.5.2.2.1
The ATS Phases Access.
Indexes
atsLoadStatusPhaseTableIndex
Column Syntax OID
atsLoadStatusPhaseTableIndex mandatory
The index to ATS phase entry.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.5.5.2.2.1.1
atsLoadStatusPhase mandatory
For single phase devices, this object will always
return phase1(1).

For 3-phase devices, this object will return phase1 (1),
phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2,
phase2-3 (5) for ph…
Enumeration
Enumerated Values:
1phase1
2phase2
3phase3
4phase1-2
5phase2-3
6phase3-1
.1.3.6.1.4.1.3808.1.1.5.5.2.2.1.2
atsLoadStatusPhaseLoad mandatory
The output current in 0.1 amperes drawn
by the load on the ATS
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.2.2.1.3
atsLoadStatusPhaseLoadState mandatory
Getting this OID will return the phase load state.
Enumeration
Enumerated Values:
1normal
2lowLoad
3nearOverLoad
4overLoad
.1.3.6.1.4.1.3808.1.1.5.5.2.2.1.4
atsLoadStatusPhasePower mandatory
The output power in Watts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.2.2.1.5

atsLoadStatusBankTable

table mandatory
.1.3.6.1.4.1.3808.1.1.5.5.2.4 · 1 row entry · 7 columns
Allows for getting the Bank Load status in the ATS.
atsLoadStatusBankEntry entry .1.3.6.1.4.1.3808.1.1.5.5.2.4.1
The ATS Bank Access.
Indexes
atsLoadStatusBankTableIndex
Column Syntax OID
atsLoadStatusBankTableIndex mandatory
The index to ATS bank entry.
Enumeration
Enumerated Values:
1total
2bank1
3bank2
4bank3
.1.3.6.1.4.1.3808.1.1.5.5.2.4.1.1
atsLoadStatusBankPhase mandatory
Getting this OID will return the phase number.
Enumeration
Enumerated Values:
1phase1
2phase2
3phase3
4phase1-2
5phase2-3
6phase3-1
.1.3.6.1.4.1.3808.1.1.5.5.2.4.1.2
atsLoadStatusBankLoad mandatory
The output current in 0.1 amperes drawn
by the load on the ATS
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.2.4.1.3
atsLoadStatusBankLoadState mandatory
Getting this OID will return the bank load state.
Enumeration
Enumerated Values:
1normal
2lowLoad
3nearOverLoad
4overLoad
.1.3.6.1.4.1.3808.1.1.5.5.2.4.1.4
atsLoadStatusBankPower mandatory
The output power in Watts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.2.4.1.5
atsLoadStatusBankEnergy mandatory
Getting this OID will return the phase/bank apparent power measured in 0.1 kilowatt-hours.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.2.4.1.6
atsLoadStatusBankStartTime mandatory
Getting this OID will return the date and time of the last energy meter reset
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.2.4.1.7

atsLoadCfgPhaseTable

table mandatory
.1.3.6.1.4.1.3808.1.1.5.5.3.2 · 1 row entry · 6 columns
Allows for configuration of each ATS phase.
atsLoadCfgPhaseEntry entry .1.3.6.1.4.1.3808.1.1.5.5.3.2.1
The ATS phase to configure.
Indexes
atsLoadCfgPhaseTableIndex
Column Syntax OID
atsLoadCfgPhaseTableIndex mandatory
The index to the ATS phase entry.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.5.5.3.2.1.1
atsLoadCfgPhase mandatory
For single phase devices, this object will always
return phase1(1).

For 3-phase devices, this object will return phase1 (1),
phase2 (2), phase3 (3), phase1-2 (4) for phases 1 and 2,
phase2-3 (5) for ph…
Enumeration
Enumerated Values:
1phase1
2phase2
3phase3
4phase1-2
5phase2-3
6phase3-1
.1.3.6.1.4.1.3808.1.1.5.5.3.2.1.2
atsLoadCfgPhaseLowLoad mandatory
A threshold that indicates the power consumption of
the load is nearing a low consumption condition. It is
represented in Amps. A warning will be issued when the
load is less than the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.3.2.1.3
atsLoadCfgPhaseNearOverLoad mandatory
A threshold that indicates the power consumption of
the load is nearing an overload condition. It is
represented in Amps. A warning will be issued when the
load is greater than or equal to the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.3.2.1.4
atsLoadCfgPhaseOverLoad mandatory
A threshold that indicates the power consumption of
the load has entered an overload condition. It is
represented in Amps. A warning will be issued when the
load is greater than or equal to the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.3.2.1.5
atsLoadCfgPhaseOutletRestriction mandatory
This OID controls the behavior of a ATS phase when an overload
condition is possible and additional outlets are requested to be
turned on.

Setting this OID to alwaysAllowTurnON (1) will always allow
t…
Enumerationr/w
Enumerated Values:
1alwaysAllowTurnON
2restrictOnNearOverload
3restrictOnOverload
.1.3.6.1.4.1.3808.1.1.5.5.3.2.1.6

atsLoadCfgBankTable

table mandatory
.1.3.6.1.4.1.3808.1.1.5.5.3.4 · 1 row entry · 6 columns
Allows for configuration of each ATS bank.
atsLoadCfgBankEntry entry .1.3.6.1.4.1.3808.1.1.5.5.3.4.1
The ATS phase to configure.
Indexes
atsLoadCfgBankTableIndex
Column Syntax OID
atsLoadCfgBankTableIndex mandatory
The index to the ATS bank entry.
Enumeration
Enumerated Values:
1total
2bank1
3bank2
4bank3
.1.3.6.1.4.1.3808.1.1.5.5.3.4.1.1
atsLoadCfgBankLowLoad mandatory
A threshold that indicates the power consumption of
the load is nearing a low consumption condition. It is
represented in Amps. A warning will be issued when the
load is less than the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.3.4.1.2
atsLoadCfgBankNearOverLoad mandatory
A threshold that indicates the power consumption of
the load is nearing an overload condition. It is
represented in Amps. A warning will be issued when the
load is greater than or equal to the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.3.4.1.3
atsLoadCfgBankOverLoad mandatory
A threshold that indicates the power consumption of
the load has entered an overload condition. It is
represented in Amps. A warning will be issued when the
load is greater than or equal to the threshold value.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.5.3.4.1.4
atsLoadCfgBankOutletRestriction mandatory
This OID controls the behavior of a ATS phase when an overload
condition is possible and additional outlets are requested to be
turned on.

Setting this OID to alwaysAllowTurnON (1) will always allow
t…
Enumerationr/w
Enumerated Values:
1alwaysAllowTurnON
2restrictOnNearOverload
3restrictOnOverload
.1.3.6.1.4.1.3808.1.1.5.5.3.4.1.5
atsLoadCfgBankEnergyReset mandatory
Setting this OID to reset (2) will cause the bank energy meter value to be reset to zero.
Getting this OID will do nothing and return the noOperation(1) value.
Enumerationr/w
Enumerated Values:
1noOperation
2reset
.1.3.6.1.4.1.3808.1.1.5.5.3.4.1.6

atsOutletStatusTable

table mandatory
.1.3.6.1.4.1.3808.1.1.5.6.3 · 1 row entry · 6 columns
Allows for getting of status of individual outlets.
atsOutletStatusEntry entry .1.3.6.1.4.1.3808.1.1.5.6.3.1
The outlet to gather status from.
Indexes
atsOutletStatusTableIndex
Column Syntax OID
atsOutletStatusTableIndex mandatory
The index to the outlet entry.
Integer32
Constraints:
range: 1-19
.1.3.6.1.4.1.3808.1.1.5.6.3.1.1
atsOutletStatusOutletName mandatory
The name of the outlet. The maximum string size is device dependent.
This OID is provided for informational purposes only.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.5.6.3.1.2
atsOutletStatusOutletState mandatory
Getting this variable will return the outlet state. If
the outlet is on, the outletStatusOn (1) value will be returned.
If the outlet is off, the outletStatusOff (2) value will be
returned.
Enumeration
Enumerated Values:
1outletStatusOn
2outletStatusOff
.1.3.6.1.4.1.3808.1.1.5.6.3.1.3
atsOutletStatusOutletCmdPending mandatory
Getting this variable will return the command pending
state of the outlet. If a command is pending on the
outlet, the outletStatusCommandPending (1) value
will be returned. If there is not a command pending
on the outl…
Enumeration
Enumerated Values:
1outletStatusCommandPending
2outletStatusNoCommandPending
.1.3.6.1.4.1.3808.1.1.5.6.3.1.4
atsOutletStatusOutletPhase mandatory
The phase/s associated with this outlet.

For single phase devices, this object will always
return phase1(1).

For 3-phase devices, this object will return phase1 (1),
phase2 (2), or phase3…
Enumeration
Enumerated Values:
1phase1
2phase2
3phase3
4phase1-2
5phase2-3
6phase3-1
.1.3.6.1.4.1.3808.1.1.5.6.3.1.5
atsOutletStatusOutletBank mandatory
The bank associated with this outlet.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.6.3.1.6

atsOutletCtrlTable

table mandatory
.1.3.6.1.4.1.3808.1.1.5.6.5 · 1 row entry · 3 columns
Allows for control of the individual outlets.
atsOutletCtrlEntry entry .1.3.6.1.4.1.3808.1.1.5.6.5.1
The outlet to control.
Indexes
atsOutletCtrlTableIndex
Column Syntax OID
atsOutletCtrlTableIndex mandatory
The index to the outlet entry.
Integer32
Constraints:
range: 1-19
.1.3.6.1.4.1.3808.1.1.5.6.5.1.1
atsOutletCtrlOutletName mandatory
The name of the outlet. The maximum string size is device dependent.
An error will be returned if the set request exceeds the max size.
This OID is provided for informational purposes only.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.5.6.5.1.2
atsOutletCtrlCommand mandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOn (2) value will be returned.
If the outlet is off, the immediateOff (2) value will be
returned.

Setting this varia…
Enumerationr/w
Enumerated Values:
1none
2immediateOn
3immediateOff
4immediateReboot
5delayedOn
6delayedOff
7delayedReboot
8cancelPendingCommand
.1.3.6.1.4.1.3808.1.1.5.6.5.1.3

atsOutletCfgTable

table mandatory
.1.3.6.1.4.1.3808.1.1.5.6.7 · 1 row entry · 5 columns
Allows for configuration of individual outlets.
atsOutletCfgEntry entry .1.3.6.1.4.1.3808.1.1.5.6.7.1
The outlet to configure.
Indexes
atsOutletCfgTableIndex
Column Syntax OID
atsOutletCfgTableIndex mandatory
The index to the outlet entry.
Integer32
Constraints:
range: 1-19
.1.3.6.1.4.1.3808.1.1.5.6.7.1.1
atsOutletCfgOutletName mandatory
The name of the outlet. The maximum string size is device dependent.
An error will be returned if the set request exceeds the max size.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.5.6.7.1.2
atsOutletCfgPowerOnTime mandatory
The amount of time (in seconds) the outlet will delay
powering on at coldstart or when a command that requires
a turn-on delay is issued.

Allowed values are:
-1 - never power on.
0 - powe…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.6.7.1.3
atsOutletCfgPowerOffTime mandatory
The amount of time (in seconds) the outlet will delay
powering off when a command that requires
a turn-off delay is issued.

Allowed values are:

-1 - never power off.
0 - po…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.6.7.1.4
atsOutletCfgRebootDuration mandatory
During a reboot sequence, power is turned off and then
back on. This OID defines the amount of time to wait,
in seconds, after turning the power off, at the start
of the sequence, before turning power back on, at the
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.5.6.7.1.5

ePDU2IdentTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.2.2 · 1 row entry · 11 columns
A table of Rack PDU identification information.
ePDU2IdentEntry entry .1.3.6.1.4.1.3808.1.1.6.2.2.1
Identification data from Rack PDU being queried.
Indexes
ePDU2IdentIndex
Column Syntax OID
ePDU2IdentIndex mandatory
The index to the Rack PDU identification table entry.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.6.2.2.1.1
ePDU2IdentModuleIndex mandatory
The Rack PDU identification table entry numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.2.2.1.2
ePDU2IdentName mandatory
A user-defined string identifying the name of the Rack PDU.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.2.2.1.3
ePDU2IdentLocation mandatory
A user-defined string identifying the location of the Rack PDU.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.2.2.1.4
ePDU2IdentContact mandatory
A user-defined string identifying the person to contact of the Rack PDU.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.2.2.1.5
ePDU2IdentHardwareRev mandatory
The Rack PDU hardware version.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.2.2.1.6
ePDU2IdentFirmwareRev mandatory
The Rack PDU firmware version.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.2.2.1.7
ePDU2IdentDateOfManufacture mandatory
The date the Rack PDU was manufactured in mm/dd/yyyy format.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.2.2.1.8
ePDU2IdentModelName mandatory
The Rack PDU model number.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.2.2.1.9
ePDU2IdentSerialNumber mandatory
The Rack PDU serial number.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.2.2.1.10
ePDU2IdentIndicator mandatory
PDU will perform a panel indicator test when the variable
is set to testIndicators(2).

It is no effective to set this value to noTestIndicators(1).
Enumerationr/w
Enumerated Values:
1noTestIndicators
2testIndicators
.1.3.6.1.4.1.3808.1.1.6.2.2.1.11

ePDU2DeviceConfigTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.3.2 · 1 row entry · 15 columns
A table of Rack PDU configuration data.
ePDU2DeviceConfigEntry entry .1.3.6.1.4.1.3808.1.1.6.3.2.1
Configuration data from Rack PDU being queried.
Indexes
ePDU2DeviceConfigIndex
Column Syntax OID
ePDU2DeviceConfigIndex mandatory
The index to the Rack PDU table entry.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.6.3.2.1.1
ePDU2DeviceConfigModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.2.1.2
ePDU2DeviceConfigName mandatory
A user-defined string identifying the name of Rack PDU.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.3.2.1.3
ePDU2DeviceConfigLocation mandatory
A user-defined string identifying the location of the Rack PDU.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.3.2.1.4
ePDU2DeviceConfigContact mandatory
A user-defined string identifying the person to contact of the Rack PDU.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.3.2.1.5
ePDU2DeviceConfigDisplayOrientation mandatory
Getting this OID will return the intended physical orientation of the Seven-Segment Display.

displayNormal(1) indicates Normal.
displayReverse(2)indicates Upside-Down.
displayRotate90(3) indicates rotate …
Enumerationr/w
Enumerated Values:
1displayNormal
2displayReverse
3displayRotate90
4displayRotate270
5displayAuto
.1.3.6.1.4.1.3808.1.1.6.3.2.1.6
ePDU2DeviceConfigColdstartDelay mandatory
The amount of delay, measured in seconds, between
when power is provided to the Rack PDU and when
the Rack PDU provides basic master power to the
outlets.

Allowed values are:
-1 - never apply power autom…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.2.1.7
ePDU2DeviceConfigCurrentLowLoadThreshold mandatory
User-defined low current draw alarm threshold, measured in Amps.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.2.1.8
ePDU2DeviceConfigCurrentNearOverloadThreshold mandatory
User-defined near overload current threshold, measured in Amps.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.2.1.9
ePDU2DeviceConfigCurrentOverloadThreshold mandatory
User-defined current overload threshold, measured in Amps.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.2.1.10
ePDU2DeviceConfigPeakLoadReset mandatory
Setting this OID to resetAll (2) will cause the existing peak current value
of Rack PDU and its outlets to be replaced by the current load current value.
Setting this OID to resetDevice (3) to reset the Rack PDU only.
Enumerationr/w
Enumerated Values:
1noOperation
2resetAll
3resetDevice
4resetOutlets
.1.3.6.1.4.1.3808.1.1.6.3.2.1.11
ePDU2DeviceConfigEnergyReset mandatory
Setting this OID to resetAll (2) will cause the device energy meter value
to be reset to zero.
Setting this OID to resetDevice (3) to reset the Rack PDU only.
Setting this OID to resetOutlets (4) to reset the PDU outle…
Enumerationr/w
Enumerated Values:
1noOperation
2resetAll
3resetDevice
4resetOutlets
.1.3.6.1.4.1.3808.1.1.6.3.2.1.12
ePDU2DeviceConfigPowerLowLoadThreshold mandatory
User-defined low power draw alarm threshold, measured in Watts.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.2.1.13
ePDU2DeviceConfigPowerNearOverloadThreshold mandatory
User-defined near overload power threshold, measured in Watts.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.2.1.14
ePDU2DeviceConfigPowerOverloadThreshold mandatory
User-defined power overload threshold, measured in Watts.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.2.1.15

ePDU2DeviceInfoTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.3.3 · 1 row entry · 13 columns
A table of Rack PDU information.
ePDU2DeviceInfoEntry entry .1.3.6.1.4.1.3808.1.1.6.3.3.1
Information of the Rack PDU being queried.
Indexes
ePDU2DeviceInfoIndex
Column Syntax OID
ePDU2DeviceInfoIndex mandatory
The index to the Rack PDU Information table entry.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.6.3.3.1.1
ePDU2DeviceInfoModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.3.1.2
ePDU2DeviceInfoName mandatory
A user-defined string identifying the name of the Rack PDU.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.3.3.1.3
ePDU2DeviceInfoRating mandatory
The electrical rating of the Rack PDU.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.3.1.4
ePDU2DeviceInfoNumOutlets mandatory
The number of outlets on the Rack PDU.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.3.1.5
ePDU2DeviceInfoSwitchedOutlets mandatory
The number of switched outlets on the Rack PDU.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.3.1.6
ePDU2DeviceInfoMeteredOutlets mandatory
The number of metered outlets on the Rack PDU.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.3.1.7
ePDU2DeviceInfoNumPhases mandatory
The number of phases present in the Rack PDU.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.3.1.8
ePDU2DeviceInfoNumBreakers mandatory
The number of metered banks present in the Rack PDU.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.3.1.9
ePDU2DeviceInfoBreakerRating mandatory
The maximum current rating, measured in Amps, for the Rack PDU.
Getting this OID will return rating of the circuit breakers on
the device if it has any.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.3.1.10
ePDU2DeviceInfoOrientation mandatory
Rack PDU orientation.
Enumeration
Enumerated Values:
1orientHorizontal
2orientVertical
.1.3.6.1.4.1.3808.1.1.6.3.3.1.11
ePDU2DeviceInfoOutletLayout mandatory
Getting this OID will return outlet layout for the device.

SeqPhaseToNeutral(1) indicates outlet layout as follows:
Outlet(1-5 and 16-20):1-N,
outlet(6-10 and 21-25):2-N,
outlet(11-15 and 26-30):3-N,4:…
Enumeration
Enumerated Values:
1seqPhaseToNeutral
2seqPhaseToPhase
3seqOther
.1.3.6.1.4.1.3808.1.1.6.3.3.1.12
ePDU2DeviceInfoPowerLimit mandatory
The maximum power limit, measured in Watt, for the Rack PDU.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.3.1.13

ePDU2DeviceStatusTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.3.4 · 1 row entry · 19 columns
A table of Rack PDU current status.
ePDU2DeviceStatusEntry entry .1.3.6.1.4.1.3808.1.1.6.3.4.1
Status data from the Rack PDU being queried.
Indexes
ePDU2DeviceStatusIndex
Column Syntax OID
ePDU2DeviceStatusIndex mandatory
The index to the Rack PDU status table entry.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.6.3.4.1.1
ePDU2DeviceStatusModuleIndex mandatory
The Rack PDU numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.4.1.2
ePDU2DeviceStatusName mandatory
A user-defined string identifying the name of the Rack PDU.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.3.4.1.3
ePDU2DeviceStatusLoadState mandatory
Indicates the present load status of the Rack PDU.
Enumeration
Enumerated Values:
1noLoadAlarm
2underCurrentAlarm
3nearOverCurrentAlarm
4overCurrentAlarm
.1.3.6.1.4.1.3808.1.1.6.3.4.1.4
ePDU2DeviceStatusCurrentLoad mandatory
The power consumption of the Rack PDU load in tenths of Amps.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.3.4.1.5
ePDU2DeviceStatusCurrentPeakLoad mandatory
The peak power consumption of the Rack PDU load in tenths of Amps.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.3.4.1.6
ePDU2DeviceStatusPeakLoadTimestamp mandatory
Indicates the date and time that peak load occurred.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.3.4.1.7
ePDU2DeviceStatusPeakLoadStartTime mandatory
Indicates the date and time of the last device peak load reset.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.3.4.1.8
ePDU2DeviceStatusEnergy mandatory
A user resettable energy meter measuring Rack PDU load
energy consumption in tenths of kilowatt-hours.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.3.4.1.9
ePDU2DeviceStatusEnergyStartTime mandatory
Indicates the date and time of the last device energy
meter reset.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.3.4.1.10
ePDU2DeviceStatusCommandPending mandatory
Indicates whether or not the device
is processing a pending command.
Enumeration
Enumerated Values:
1commandPending
2noCommandPending
.1.3.6.1.4.1.3808.1.1.6.3.4.1.11
ePDU2DeviceStatusPowerSupplyAlarm mandatory
Indicates a power supply alarm is active when value
equals alarm (2).
Enumeration
Enumerated Values:
1normal
2alarm
.1.3.6.1.4.1.3808.1.1.6.3.4.1.12
ePDU2DeviceStatusPowerSupply1Status mandatory
Indicates whether or not an alarm is active in Power
Supply 1.
Enumeration
Enumerated Values:
1normal
2alarm
.1.3.6.1.4.1.3808.1.1.6.3.4.1.13
ePDU2DeviceStatusPowerSupply2Status mandatory
Indicates whether or not an alarm is active in Power
Supply 2.
Enumeration
Enumerated Values:
1normal
2alarm
.1.3.6.1.4.1.3808.1.1.6.3.4.1.14
ePDU2DeviceStatusApparentPower mandatory
The apparent power consumption of the Rack PDU
load in VoltAmps (VA).
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.3.4.1.15
ePDU2DeviceStatusPowerFactor mandatory
The power factor of the Rack PDU load in hundredths.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.3.4.1.16
ePDU2DeviceStatusRoleType mandatory
Get this oid shows the role the PDU played on Daisy Chain Group.
The PDU as a Host can access whole ePDU2 content, and the PDU be standalong
or a Slave can access itself instead.
Enumeration
Enumerated Values:
1standalone
2host
3slave
.1.3.6.1.4.1.3808.1.1.6.3.4.1.17
ePDU2DeviceStatusPowerLoad mandatory
The power consumption of the Rack PDU load in Watts.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.3.4.1.18
ePDU2DeviceStatusPowerPeakLoad mandatory
The peak power consumption of the Rack PDU load in Watts.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.3.4.1.19
.1.3.6.1.4.1.3808.1.1.6.3.5 · 1 row entry · 4 columns
A table of Rack PDU control data.
ePDU2DeviceControlEntry entry .1.3.6.1.4.1.3808.1.1.6.3.5.1
Control data from Rack PDU being queried.
Indexes
ePDU2DeviceControlIndex
Column Syntax OID
ePDU2DeviceControlIndex mandatory
The index to the Rack PDU control table entry.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.6.3.5.1.1
ePDU2DeviceControlModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.3.5.1.2
ePDU2DeviceControlName mandatory
A user-defined string identifying the name of the Rack PDU.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.3.5.1.3
ePDU2DeviceControlCommand mandatory
Setting this OID to immediateAllOn (1) will turn all outlets on immediately.

Setting this OID to immediateAllOff (2) will turn all outlets off immediately.

Setting this OID to immediateAllR…
Enumerationr/w
Enumerated Values:
1immediateAllOn
2immediateAllOff
3immediateAllReboot
4delayedAllOn
5delayedAllOff
6delayedAllReboot
7cancelAllPendingCommand
8noCommand
.1.3.6.1.4.1.3808.1.1.6.3.5.1.4

ePDU2PhaseConfigTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.4.2 · 1 row entry · 8 columns
A table of Rack PDU phase configuration data.
ePDU2PhaseConfigEntry entry .1.3.6.1.4.1.3808.1.1.6.4.2.1
Configuration data from currently queried
Rack PDU phase.
Indexes
ePDU2PhaseConfigIndex
Column Syntax OID
ePDU2PhaseConfigIndex mandatory
The index to the Rack PDU phase configuration
table entry.
Integer32
Constraints:
range: 1-12
.1.3.6.1.4.1.3808.1.1.6.4.2.1.1
ePDU2PhaseConfigModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.4.2.1.2
ePDU2PhaseConfigNumber mandatory
The numeric phase ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.4.2.1.3
ePDU2PhaseConfigOverloadRestriction mandatory
This OID controls the behavior of a Switched Rack PDU
phase when an overload condition is possible and
additional outlets are requested to be turned on.

Setting this OID to alwaysAllowTurnON (1) will a…
Enumerationr/w
Enumerated Values:
-1notSupported
1alwaysAllowTurnON
2restrictOnNearOverload
3restrictOnOverload
.1.3.6.1.4.1.3808.1.1.6.4.2.1.4
ePDU2PhaseConfigLowLoadThreshold mandatory
User-defined low load phase current threshold in Amps.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.4.2.1.5
ePDU2PhaseConfigNearOverloadThreshold mandatory
User-defined near phase overload current warning
threshold in Amps.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.4.2.1.6
ePDU2PhaseConfigOverloadThreshold mandatory
User-defined phase overload current threshold
in Amps
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.4.2.1.7
ePDU2PhaseConfigPhasePeakLoadReset mandatory
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value.

Getting this OID will do nothing and return the noOperation(1) value.
Enumerationr/w
Enumerated Values:
1noOperation
2reset
.1.3.6.1.4.1.3808.1.1.6.4.2.1.8

ePDU2PhaseInfoTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.4.3 · 1 row entry · 3 columns
A table of Rack PDU phase information.
ePDU2PhaseInfoEntry entry .1.3.6.1.4.1.3808.1.1.6.4.3.1
Information data from currently queried Rack PDU phase.
Indexes
ePDU2PhaseInfoIndex
Column Syntax OID
ePDU2PhaseInfoIndex mandatory
The index to the Rack PDU phase properties table entry.
Integer32
Constraints:
range: 1-12
.1.3.6.1.4.1.3808.1.1.6.4.3.1.1
ePDU2PhaseInfoModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.4.3.1.2
ePDU2PhaseInfoNumber mandatory
The numeric phase ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.4.3.1.3

ePDU2PhaseStatusTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.4.4 · 1 row entry · 13 columns
A table of Rack PDU phase status data
ePDU2PhaseStatusEntry entry .1.3.6.1.4.1.3808.1.1.6.4.4.1
Status data from currently queried Rack PDU phase
Indexes
ePDU2PhaseStatusIndex
Column Syntax OID
ePDU2PhaseStatusIndex mandatory
The index to the Rack PDU phase status table entry.
Integer32
Constraints:
range: 1-12
.1.3.6.1.4.1.3808.1.1.6.4.4.1.1
ePDU2PhaseStatusModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.4.4.1.2
ePDU2PhaseStatusNumber mandatory
The numeric phase ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.4.4.1.3
ePDU2PhaseStatusLoadState mandatory
Indicates the present load status of the Rack
PDU phase being queried.
Enumeration
Enumerated Values:
1normal
2lowLoad
3nearOverload
4overload
.1.3.6.1.4.1.3808.1.1.6.4.4.1.4
ePDU2PhaseStatusLoad mandatory
Indicates the current draw, in tenths of Amps, of the load
on the Rack PDU phase being queried.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.4.4.1.5
ePDU2PhaseStatusVoltage mandatory
Indicates the Voltage, in tenths of Volts, of the Rack PDU phase being queried.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.4.4.1.6
ePDU2PhaseStatusPower mandatory
Indicates the load power, in watts,
consumed on the Rack PDU phase being queried
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.4.4.1.7
ePDU2PhaseStatusApparentPower mandatory
Indicates the load apparent power, in VoltAmps (VA),
consumed on the Rack PDU phase being queried
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.4.4.1.8
ePDU2PhaseStatusPowerFactor mandatory
Indicates the load power factor, in hundredths,
of the Rack PDU phase being queried
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.4.4.1.9
ePDU2PhaseStatusPeakLoad mandatory
The peak current of the Rack PDU phase load in tenths of Amps
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.4.4.1.10
ePDU2PhaseStatusPeakLoadTimestamp mandatory
Indicates the date and time the phase peak current occurred.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.4.4.1.11
ePDU2PhaseStatusPeakLoadStartTime mandatory
Indicates the date and time of the last phase peak current reset.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.4.4.1.12
ePDU2PhaseStatusLineToLineVoltage mandatory
Indicates the Line to Line Voltage, in tenths of Volts, of the Rack
PDU phase being queried
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.4.4.1.13

ePDU2BankConfigTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.5.2 · 1 row entry · 8 columns
A table of Rack PDU bank configuration data.
ePDU2BankConfigEntry entry .1.3.6.1.4.1.3808.1.1.6.5.2.1
Configuration data from currently queried
Rack PDU bank.
Indexes
ePDU2BankConfigIndex
Column Syntax OID
ePDU2BankConfigIndex mandatory
The index to the Rack PDU bank configuration
table entry.
Integer32
Constraints:
range: 1-12
.1.3.6.1.4.1.3808.1.1.6.5.2.1.1
ePDU2BankConfigModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.5.2.1.2
ePDU2BankConfigNumber mandatory
The numeric bank ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.5.2.1.3
ePDU2BankConfigOverloadRestriction mandatory
This OID controls the behavior of a Switched Rack PDU
bank when an overload condition is possible and
additional outlets are requested to be turned on.

Setting this OID to alwaysAllowTurnON (1) will al…
Enumerationr/w
Enumerated Values:
1alwaysAllowTurnON
2restrictOnNearOverload
3restrictOnOverload
.1.3.6.1.4.1.3808.1.1.6.5.2.1.4
ePDU2BankConfigLowLoadThreshold mandatory
User-defined low load bank current threshold in Amps.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.5.2.1.5
ePDU2BankConfigNearOverloadThreshold mandatory
User-defined near bank overload current warning
threshold in Amps.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.5.2.1.6
ePDU2BankConfigOverloadThreshold mandatory
User-defined bank overload current threshold
in Amps
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.5.2.1.7
ePDU2BankConfigPeakLoadReset mandatory
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value.

Getting this OID will do nothing and return the noOperation(1) value.
Enumerationr/w
Enumerated Values:
1noOperation
2reset
.1.3.6.1.4.1.3808.1.1.6.5.2.1.8

ePDU2BankInfoTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.5.3 · 1 row entry · 3 columns
A table of Rack PDU bank information.
ePDU2BankInfoEntry entry .1.3.6.1.4.1.3808.1.1.6.5.3.1
Information data from currently queried Rack PDU bank.
Indexes
ePDU2BankInfoIndex
Column Syntax OID
ePDU2BankInfoIndex mandatory
The index to the Rack PDU bank properties table entry.
Integer32
Constraints:
range: 1-12
.1.3.6.1.4.1.3808.1.1.6.5.3.1.1
ePDU2BankInfoModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.5.3.1.2
ePDU2BankInfoNumber mandatory
The numeric bank ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.5.3.1.3

ePDU2BankStatusTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.5.4 · 1 row entry · 8 columns
A table of Rack PDU bank status data
ePDU2BankStatusEntry entry .1.3.6.1.4.1.3808.1.1.6.5.4.1
Status data from currently queried Rack PDU bank
Indexes
ePDU2BankStatusIndex
Column Syntax OID
ePDU2BankStatusIndex mandatory
The index to the Rack PDU bank status table entry.
Integer32
Constraints:
range: 1-12
.1.3.6.1.4.1.3808.1.1.6.5.4.1.1
ePDU2BankStatusModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.5.4.1.2
ePDU2BankStatusNumber mandatory
The numeric bank ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.5.4.1.3
ePDU2BankStatusLoadState mandatory
Indicates the present load status of the Rack
PDU bank being queried.
Enumeration
Enumerated Values:
1normal
2lowLoad
3nearOverload
4overload
.1.3.6.1.4.1.3808.1.1.6.5.4.1.4
ePDU2BankStatusLoad mandatory
Indicates the current draw, in tenths of Amps, of the load
on the Rack PDU bank being queried.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.5.4.1.5
ePDU2BankStatusPeakLoad mandatory
The peak current of the Rack PDU bank load in tenths of Amps.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.5.4.1.6
ePDU2BankStatusPeakLoadTimestamp mandatory
Indicates the date and time the bank peak current occurred.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.5.4.1.7
ePDU2BankStatusPeakLoadStartTime mandatory
Indicates the date and time of the last bank peak current reset.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.5.4.1.8
.1.3.6.1.4.1.3808.1.1.6.6.1.2 · 1 row entry · 7 columns
A table of Rack PDU switched outlet configuration data.
ePDU2OutletSwitchedConfigEntry entry .1.3.6.1.4.1.3808.1.1.6.6.1.2.1
Configuration data from currently queried Rack PDU
switched outlet.
Indexes
ePDU2OutletSwitchedConfigIndex
Column Syntax OID
ePDU2OutletSwitchedConfigIndex mandatory
The index to the Rack PDU switched outlet configuration table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.6.6.1.2.1.1
ePDU2OutletSwitchedConfigModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.2.1.2
ePDU2OutletSwitchedConfigNumber mandatory
The numeric switched outlet ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.2.1.3
ePDU2OutletSwitchedConfigName mandatory
The user-defined switched outlet name string.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.1.2.1.4
ePDU2OutletSwitchedConfigPowerOnTime mandatory
The amount of time (in seconds) the outlet will delay
powering on at coldstart or when a command that requires
a turn-on delay is issued.

Allowed values are:
-1 - never power on.
0 - power on immedia…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.2.1.5
ePDU2OutletSwitchedConfigPowerOffTime mandatory
The amount of time (in seconds) the outlet will delay
powering off when a command that requires a
turn-off delay is issued.

Allowed values are:
-1 - never power off.
0 - power off immediately.
1 t…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.2.1.6
ePDU2OutletSwitchedConfigRebootDuration mandatory
During a reboot sequence, power is turned off and then
back on. This OID defines the amount of time to wait,
in seconds, after turning the power off, at the start
of the sequence, before turning power back on, at the…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.2.1.7
.1.3.6.1.4.1.3808.1.1.6.6.1.3 · 1 row entry · 6 columns
A table of Rack PDU switched outlet information.
ePDU2OutletSwitchedInfoEntry entry .1.3.6.1.4.1.3808.1.1.6.6.1.3.1
Information of the currently queried Rack PDU
switched outlet.
Indexes
ePDU2OutletSwitchedInfoIndex
Column Syntax OID
ePDU2OutletSwitchedInfoIndex mandatory
The index to the Rack PDU switched outlet information table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.6.6.1.3.1.1
ePDU2OutletSwitchedInfoModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.3.1.2
ePDU2OutletSwitchedInfoNumber mandatory
The numeric switched outlet ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.3.1.3
ePDU2OutletSwitchedInfoName mandatory
The numeric switched outlet name.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.1.3.1.4
ePDU2OutletSwitchedInfoPhaseLayout mandatory
This OID describes the phase connections of the referenced outlet as follows:
seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral.
seqPhase2ToNeutral(2) indicates that the outlet is wired fr…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.3.1.5
ePDU2OutletSwitchedInfoBank mandatory
The numeric bank ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.3.1.6
.1.3.6.1.4.1.3808.1.1.6.6.1.4 · 1 row entry · 6 columns
A table of Rack PDU switched outlet status information.
ePDU2OutletSwitchedStatusEntry entry .1.3.6.1.4.1.3808.1.1.6.6.1.4.1
Status information for currently queried Rack PDU switched outlet.
Indexes
ePDU2OutletSwitchedStatusIndex
Column Syntax OID
ePDU2OutletSwitchedStatusIndex mandatory
The index to the Rack PDU switched outlet status information table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.6.6.1.4.1.1
ePDU2OutletSwitchedStatusModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.4.1.2
ePDU2OutletSwitchedStatusNumber mandatory
The numeric switched outlet ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.4.1.3
ePDU2OutletSwitchedStatusName mandatory
The user-defined switched outlet name string.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.1.4.1.4
ePDU2OutletSwitchedStatusState mandatory
Indicates the present switch state of the Rack PDU switched outlet being queried.
Enumeration
Enumerated Values:
1outletStatusOn
2outletStatusOff
.1.3.6.1.4.1.3808.1.1.6.6.1.4.1.5
ePDU2OutletSwitchedStatusCommandPending mandatory
Getting this variable will return the command pending state of the outlet.
If a command is pending on the outlet, the outletStatusCommandPending (1)
value will be returned. If there is not a command pending on the out…
Enumeration
Enumerated Values:
1outletStatusCommandPending
2outletStatusNoCommandPending
.1.3.6.1.4.1.3808.1.1.6.6.1.4.1.6
.1.3.6.1.4.1.3808.1.1.6.6.1.5 · 1 row entry · 5 columns
A table of Rack PDU switched outlet control data.
ePDU2OutletSwitchedControlEntry entry .1.3.6.1.4.1.3808.1.1.6.6.1.5.1
Control data for currently queried Rack PDU switched outlet.
Indexes
ePDU2OutletSwitchedControlIndex
Column Syntax OID
ePDU2OutletSwitchedControlIndex mandatory
The index to the Rack PDU switched outlet control data table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.6.6.1.5.1.1
ePDU2OutletSwitchedControlModuleIndex mandatory
The user-defined Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.5.1.2
ePDU2OutletSwitchedControlNumber mandatory
The numeric switched outlet ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.1.5.1.3
ePDU2OutletSwitchedControlName mandatory
The user-defined switched outlet name string.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.1.5.1.4
ePDU2OutletSwitchedControlCommand mandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOn (1) value will be returned.
If the outlet is off, the immediateOff (2) value will be returned.

Setting this vari…
Enumerationr/w
Enumerated Values:
1immediateOn
2immediateOff
3immediateReboot
4delayedOn
5delayedOff
6delayedReboot
7cancelPendingCommand
8outletIdentify
.1.3.6.1.4.1.3808.1.1.6.6.1.5.1.5
.1.3.6.1.4.1.3808.1.1.6.6.2.2 · 1 row entry · 7 columns
A table of Rack PDU metered outlet configuration data.
ePDU2OutletMeteredConfigEntry entry .1.3.6.1.4.1.3808.1.1.6.6.2.2.1
Configuration data from currently queried Rack PDU metered outlet.
Indexes
ePDU2OutletMeteredConfigIndex
Column Syntax OID
ePDU2OutletMeteredConfigIndex mandatory
The index to the Rack PDU metered outlet configuration table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.6.6.2.2.1.1
ePDU2OutletMeteredConfigModuleIndex mandatory
The user-defined Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.2.1.2
ePDU2OutletMeteredConfigNumber mandatory
The numeric metered outlet ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.2.1.3
ePDU2OutletMeteredConfigName mandatory
The user-defined metered outlet name string.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.2.2.1.4
ePDU2OutletMeteredConfigLowLoadThreshold mandatory
User-defined outlet low load current threshold in Watts.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.2.1.5
ePDU2OutletMeteredConfigNearOverloadThreshold mandatory
User-defined outlet near overload warning threshold in Watts.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.2.1.6
ePDU2OutletMeteredConfigOverloadThreshold mandatory
User-defined outlet overload current threshold in Watts.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.2.1.7
.1.3.6.1.4.1.3808.1.1.6.6.2.3 · 1 row entry · 7 columns
A table of Rack PDU metered outlet information.
ePDU2OutletMeteredInfoEntry entry .1.3.6.1.4.1.3808.1.1.6.6.2.3.1
Information of currently queried Rack PDU metered outlet.
Indexes
ePDU2OutletMeteredInfoIndex
Column Syntax OID
ePDU2OutletMeteredInfoIndex mandatory
The index to the Rack PDU metered information table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.6.6.2.3.1.1
ePDU2OutletMeteredInfoModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.3.1.2
ePDU2OutletMeteredInfoNumber mandatory
The numeric metered outlet ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.3.1.3
ePDU2OutletMeteredInfoName mandatory
The user-defined metered outlet name string.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.2.3.1.4
ePDU2OutletMeteredInfoLayout mandatory
This OID describes the phase connections of the referenced outlet as follows:
seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral.
seqPhase2ToNeutral(2) indicates that the outlet is wired fr…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.3.1.5
ePDU2OutletMeteredInfoRating mandatory
Maximum power rating of Rack PDU metered outlet.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.3.1.6
ePDU2OutletMeteredInfoBank mandatory
This outlet's numeric bank ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.3.1.7
.1.3.6.1.4.1.3808.1.1.6.6.2.4 · 1 row entry · 12 columns
A table of Rack PDU metered outlet status data.
ePDU2OutletMeteredStatusEntry entry .1.3.6.1.4.1.3808.1.1.6.6.2.4.1
Status data from currently queried Rack PDU metered outlet.
Indexes
ePDU2OutletMeteredStatusIndex
Column Syntax OID
ePDU2OutletMeteredStatusIndex mandatory
The index to the Rack PDU metered status table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.1
ePDU2OutletMeteredStatusModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.2
ePDU2OutletMeteredStatusNumber mandatory
The numeric metered outlet ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.3
ePDU2OutletMeteredStatusName mandatory
The user-defined metered outlet name string.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.4
ePDU2OutletMeteredStatusAlarm mandatory
Getting this OID will return the current outlet alarm.
Enumeration
Enumerated Values:
1noLoadAlarm
2underCurrentAlarm
3nearOverCurrentAlarm
4overCurrentAlarm
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.5
ePDU2OutletMeteredStatusLoad mandatory
Getting this OID will return the measured Outlet load
for an Outlet Monitored Rack PDU in tenths of Amps.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.6
ePDU2OutletMeteredStatusActivePower mandatory
Getting this OID will return the measured Outlet load for
an Outlet Monitored Rack PDU in watts.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.7
ePDU2OutletMeteredStatusPeakPower mandatory
The peak power consumption of the Rack PDU load in watts.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.8
ePDU2OutletMeteredStatusPeakPowerTimestamp mandatory
Get this oid shows the date and time that peak power
consumption occurred.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.9
ePDU2OutletMeteredStatusPeakPowerStartTime mandatory
Get this oid shows the date and time that peak power
consumption started.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.10
ePDU2OutletMeteredStatusEnergy mandatory
Energy meter measuring Rack PDU load energy consumption
in tenths of kilowatt-hours.
RFC1155-SMIGauge
Textual Convention: RFC1155-SMIGauge Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.11
ePDU2OutletMeteredStatusEnergyStart mandatory
Indicates the date and time of the last device energy
meter reset.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.2.4.1.12
.1.3.6.1.4.1.3808.1.1.6.6.3.2 · 1 row entry · 4 columns
A table of Rack PDU monitored outlet configuration data.
ePDU2OutletMonitoredConfigEntry entry .1.3.6.1.4.1.3808.1.1.6.6.3.2.1
Configuration data from currently queried Rack PDU monitored outlet.
Indexes
ePDU2OutletMonitoredConfigIndex
Column Syntax OID
ePDU2OutletMonitoredConfigIndex mandatory
The index to the Rack PDU monitored outlet configuration table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.6.6.3.2.1.1
ePDU2OutletMonitoredConfigModuleIndex mandatory
The user-defined Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.3.2.1.2
ePDU2OutletMonitoredConfigNumber mandatory
The numeric monitored outlet ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.3.2.1.3
ePDU2OutletMonitoredConfigName mandatory
The user-defined monitored outlet name string.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.3.2.1.4
.1.3.6.1.4.1.3808.1.1.6.6.3.3 · 1 row entry · 7 columns
A table of Rack PDU monitored outlet information.
ePDU2OutletMonitoredInfoEntry entry .1.3.6.1.4.1.3808.1.1.6.6.3.3.1
Information of currently queried Rack PDU monitored outlet.
Indexes
ePDU2OutletMonitoredInfoIndex
Column Syntax OID
ePDU2OutletMonitoredInfoIndex mandatory
The index to the Rack PDU monitored information table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.6.6.3.3.1.1
ePDU2OutletMonitoredInfoModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.3.3.1.2
ePDU2OutletMonitoredInfoNumber mandatory
The numeric monitored outlet ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.3.3.1.3
ePDU2OutletMonitoredInfoName mandatory
The user-defined monitored outlet name string.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.3.3.1.4
ePDU2OutletMonitoredInfoLayout mandatory
This OID describes the phase connections of the referenced outlet as follows:
seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral.
seqPhase2ToNeutral(2) indicates that the outlet is wired fr…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.3.3.1.5
ePDU2OutletMonitoredInfoRating mandatory
Maximum power rating of Rack PDU monitored outlet.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.3.3.1.6
ePDU2OutletMonitoredInfoBank mandatory
This outlet's numeric bank ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.3.3.1.7
.1.3.6.1.4.1.3808.1.1.6.6.3.4 · 1 row entry · 4 columns
A table of Rack PDU monitored outlet status data.
ePDU2OutletMonitoredStatusEntry entry .1.3.6.1.4.1.3808.1.1.6.6.3.4.1
Status data from currently queried Rack PDU monitored outlet.
Indexes
ePDU2OutletMonitoredStatusIndex
Column Syntax OID
ePDU2OutletMonitoredStatusIndex mandatory
The index to the Rack PDU monitored status table entry.
Integer32
Constraints:
range: 1-96
.1.3.6.1.4.1.3808.1.1.6.6.3.4.1.1
ePDU2OutletMonitoredStatusModuleIndex mandatory
The Rack PDU numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.3.4.1.2
ePDU2OutletMonitoredStatusNumber mandatory
The numeric monitored outlet ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.6.3.4.1.3
ePDU2OutletMonitoredStatusName mandatory
The user-defined monitored outlet name string.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.6.6.3.4.1.4

ePDU2SourceConfigTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.9.2 · 1 row entry · 11 columns
A table of Source configuration data.
ePDU2SourceConfigEntry entry .1.3.6.1.4.1.3808.1.1.6.9.2.1
Configuration data from Source being queried.
Indexes
ePDU2SourceConfigIndex
Column Syntax OID
ePDU2SourceConfigIndex mandatory
The index to the Automatic Transfer Switch table entry.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.6.9.2.1.1
ePDU2SourceConfigModuleIndex mandatory
The Automatic Transfer Switch numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.2.1.2
ePDU2SourceConfigPreferredSource mandatory
This variable returns the preferred source of power when both sources are OK
Enumerationr/w
Enumerated Values:
1sourceA
2sourceB
3none
.1.3.6.1.4.1.3808.1.1.6.9.2.1.3
ePDU2SourceConfigFrequencyDeviation mandatory
To configure the frequency deviation.
Integer32r/w
Constraints:
range: 1-3
.1.3.6.1.4.1.3808.1.1.6.9.2.1.4
ePDU2SourceConfigVoltageSensitivity mandatory
This variable defines the sensitivity to changes in voltage:
high(1) for best protection, low(3) for frequent small line
voltage changes.
Enumerationr/w
Enumerated Values:
1high
2medium
3low
.1.3.6.1.4.1.3808.1.1.6.9.2.1.5
ePDU2SourceConfigNominalVoltage mandatory
This variable returns the nominal voltage of the input.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.2.1.6
ePDU2SourceConfigTransferVoltageRange mandatory
This variable defines the range of acceptable voltage from a power source.
If the voltage measured from the selected input source is not within this
range, the Automatic Transfer Switch will switch over (transfer) to th…
Enumerationr/w
Enumerated Values:
1wide
2medium
3narrow
.1.3.6.1.4.1.3808.1.1.6.9.2.1.7
ePDU2SourceConfigNarrowRangeValue mandatory
To configure the Narrow Range value of acceptable voltage
from a power source.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.2.1.8
ePDU2SourceConfigMediumRangeValue mandatory
To configure the Medium Range value of acceptable voltage
from a power source.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.2.1.9
ePDU2SourceConfigWideRangeValue mandatory
To configure the Wide Range value of acceptable voltage
from a power source.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.2.1.10
ePDU2EventCountsReset mandatory
Setting this variable will clear all event counts in Automatic Transfer Switch.
Enumerationr/w
Enumerated Values:
1none
2clear
.1.3.6.1.4.1.3808.1.1.6.9.2.1.11

ePDU2SourceInfoTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.9.3 · 1 row entry · 10 columns
A table of Automatic Transfer Switch information.
ePDU2SourceInfoEntry entry .1.3.6.1.4.1.3808.1.1.6.9.3.1
Information of the Automatic Transfer Switch being queried.
Indexes
ePDU2SourceInfoIndex
Column Syntax OID
ePDU2SourceInfoIndex mandatory
The index to the Automatic Transfer Switch Information table entry.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.6.9.3.1.1
ePDU2SourceInfoModuleIndex mandatory
The Automatic Transfer Switch numeric ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.3.1.2
ePDU2SourceInfoSourceSwitch mandatory
The Source Switch event counts of Automatic Transfer Switch.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.3.1.3
ePDU2SourceInfoSourcePreferenceChange mandatory
The Source Preference Change event counts of Automatic Transfer Switch.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.3.1.4
ePDU2SourceInfoPreferredSourceFreqOutofRange mandatory
The Preferred Source Frequency Out of Range event counts of Automatic Transfer Switch.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.3.1.5
ePDU2SourceInfoPreferredSourceVoltOutofRange mandatory
The Preferred Source Voltage Out of Range event counts of Automatic Transfer Switch.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.3.1.6
ePDU2SourceInfoDeviceCurrentOverload mandatory
The Device Current Overload event counts of Automatic Transfer Switch.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.3.1.7
ePDU2SourceInfoBank1Overload mandatory
The Bank 1 Current Overload event counts of Automatic Transfer Switch.
Models that do not support this feature will respond to this OID
with a value of (-1).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.3.1.8
ePDU2SourceInfoBank2Overload mandatory
The Bank 2 Current Overload event counts of Automatic Transfer Switch.
Models that do not support this feature will respond to this OID
with a value of (-1).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.3.1.9
ePDU2SourceInfoBank3Overload mandatory
The Bank 3 Current Overload event counts of Automatic Transfer Switch.
Models that do not support this feature will respond to this OID
with a value of (-1).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.3.1.10

ePDU2SourceStatusTable

table mandatory
.1.3.6.1.4.1.3808.1.1.6.9.4 · 1 row entry · 16 columns
A table of Automatic Transfer Switch current status.
ePDU2SourceStatusEntry entry .1.3.6.1.4.1.3808.1.1.6.9.4.1
Status data from the Automatic Transfer Switch being queried.
Indexes
ePDU2SourceStatusIndex
Column Syntax OID
ePDU2SourceStatusIndex mandatory
The index to the Automatic Transfer Switch status table entry.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.6.9.4.1.1
ePDU2SourceStatusModuleIndex mandatory
The Automatic Transfer Switch numeric ID
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.4.1.2
ePDU2SourceStatusSelectedSource mandatory
This variable returns the current source of power.
Enumeration
Enumerated Values:
1sourceA
2sourceB
3none
.1.3.6.1.4.1.3808.1.1.6.9.4.1.3
ePDU2SourceStatusNominalFrequency mandatory
The Nominal Frequency in 0.1 Hertz.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.4.1.4
ePDU2SourceStatusSourceAVoltage mandatory
The input voltage of source A in 0.1 Volt.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.4.1.5
ePDU2SourceStatusSourceBVoltage mandatory
The input voltage of source B in 0.1 Volt.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.4.1.6
ePDU2SourceStatusSourceAFrequency mandatory
The input frequency of source A in 0.1 Hertz.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.4.1.7
ePDU2SourceStatusSourceBFrequency mandatory
The input frequency of source B in 0.1 Hertz.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.6.9.4.1.8
ePDU2SourceStatusSourceAVolStatus mandatory
The input voltage status of source A.
Enumeration
Enumerated Values:
1normal
2overVoltage
3underVoltage
.1.3.6.1.4.1.3808.1.1.6.9.4.1.9
ePDU2SourceStatusSourceBVolStatus mandatory
The input voltage status of source B.
Enumeration
Enumerated Values:
1normal
2overVoltage
3underVoltage
.1.3.6.1.4.1.3808.1.1.6.9.4.1.10
ePDU2SourceStatusSourceAFreqStatus mandatory
The input frequency status of source A.
Enumeration
Enumerated Values:
1normal
2overFrequency
3underFrequency
.1.3.6.1.4.1.3808.1.1.6.9.4.1.11
ePDU2SourceStatusSourceBFreqStatus mandatory
The input frequency status of source B.
Enumeration
Enumerated Values:
1normal
2overFrequency
3underFrequency
.1.3.6.1.4.1.3808.1.1.6.9.4.1.12
ePDU2SourceStatusSourcePhaseSync mandatory
This variable returns the status of the phase sync.
Enumeration
Enumerated Values:
1inSync
2outOfSync
.1.3.6.1.4.1.3808.1.1.6.9.4.1.13
ePDU2SourceStatusPowerSupplySourceAStatus mandatory
This variable returns the status of the power supply in system.
normal(1) indicates the power supply of source A in normal.
3.3vFailed(2) indicates the power supply 3.3v of source A is failed.
24vFailed(3) indicates the…
Enumeration
Enumerated Values:
1normal
2failed3p3v
3failed24v
4failed3p3and24v
.1.3.6.1.4.1.3808.1.1.6.9.4.1.14
ePDU2SourceStatusPowerSupplySourceBStatus mandatory
This variable returns the status of the power supply in system.
normal(1) indicates the power supply of source B in normal.
3.3vFailed(2) indicates the power supply 3.3v of source B is failed.
24vFailed(3) indicates the…
Enumeration
Enumerated Values:
1normal
2failed3p3v
3failed24v
4failed3p3and24v
.1.3.6.1.4.1.3808.1.1.6.9.4.1.15
ePDU2SourceStatusRedundancyState mandatory
This variable returns the current redundancy state of the ATS.
atsRedundancyLost(1) indicates that the ATS is unable to switch over to the alternate power source if the current source fails.
atsFullyRedundant(2) indicat…
Enumeration
Enumerated Values:
1atsRedundancyLost
2atsFullyRedundant
.1.3.6.1.4.1.3808.1.1.6.9.4.1.16

bmProbesTable

table mandatory
.1.3.6.1.4.1.3808.1.1.7.5.3 · 1 row entry · 4 columns
The battery probes installation information.
bmProbesEntry entry .1.3.6.1.4.1.3808.1.1.7.5.3.1
The battery probes installation information.
Indexes
bmProbesIndex
Column Syntax OID
bmProbesIndex mandatory
The index of the bmProbesEntry entry.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.5.3.1.1
bmProbesPackIndex mandatory
The pack number the battery probe installed.
Integer32
Constraints:
range: 1-64
.1.3.6.1.4.1.3808.1.1.7.5.3.1.2
bmProbesStringIndex mandatory
The string number the battery probe installed.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.3808.1.1.7.5.3.1.3
bmProbesBattIndex mandatory
The battery number the battery probe installed.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.5.3.1.4

bmProbesVoltageTable

table mandatory
.1.3.6.1.4.1.3808.1.1.7.5.5 · 1 row entry · 10 columns
The batteries voltage information.
bmProbesVoltageEntry entry .1.3.6.1.4.1.3808.1.1.7.5.5.1
The batteries voltage information.
Indexes
bmProbesVoltageIndex
Column Syntax OID
bmProbesVoltageIndex mandatory
The index of the BmProbesVoltageEntry entry.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.5.5.1.1
bmProbesVoltagePackIndex mandatory
The battery pack number the battery voltage reading belongs to.
Integer32
Constraints:
range: 1-64
.1.3.6.1.4.1.3808.1.1.7.5.5.1.2
bmProbesVoltageStringIndex mandatory
The battery string number the battery voltage reading belongs to.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.3808.1.1.7.5.5.1.3
bmProbesVoltageBattIndex mandatory
The battery index to the voltage record within its string.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.5.5.1.4
bmProbesVoltageProbeIndex mandatory
The probe index to the voltage record.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.5.5.1.5
bmProbesVoltageAlarmStatus mandatory
The battery voltage alarm status.
Enumeration
Enumerated Values:
1voltageNormal
2voltageWarnLow
3voltageWarnHigh
4voltageAlarmLow
5voltageAlarmHigh
.1.3.6.1.4.1.3808.1.1.7.5.5.1.6
bmProbesVoltage mandatory
Getting this oid to get battery voltage, unit in 10mV (0.01 volt).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.7.5.5.1.7
bmProbesVoltageEqualPercentage mandatory
Getting this oid to get battery voltage equalizing power, unit in percentage.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.7.5.5.1.8
bmProbesVoltageSocAlarmStatus mandatory
The battery soc alarm status.
Enumeration
Enumerated Values:
1voltageSocNormal
2voltageSocWarnLow
3voltageSocWarnHigh
4voltageSocAlarmLow
5voltageSocAlarmHigh
.1.3.6.1.4.1.3808.1.1.7.5.5.1.9
bmProbesVoltageSoc mandatory
Getting this oid to get battery soc, unit in percentage.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.7.5.5.1.10

bmProbesTempTable

table mandatory
.1.3.6.1.4.1.3808.1.1.7.5.7 · 1 row entry · 7 columns
The batteries temperature information.
bmProbesTempEntry entry .1.3.6.1.4.1.3808.1.1.7.5.7.1
The batteries temperature information.
Indexes
bmProbesTempIndex
Column Syntax OID
bmProbesTempIndex mandatory
The index of the BmProbesTempEntry entry.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.5.7.1.1
bmProbesTempPackIndex mandatory
The battery pack number the battery temperature reading belongs to.
Integer32
Constraints:
range: 1-64
.1.3.6.1.4.1.3808.1.1.7.5.7.1.2
bmProbesTempStringIndex mandatory
The battery string number the battery temperature reading belongs to.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.3808.1.1.7.5.7.1.3
bmProbesTempBattIndex mandatory
The index to the battery.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.5.7.1.4
bmProbesTempProbeIndex mandatory
The index to the probe.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.5.7.1.5
bmProbesTempAlarmStatus mandatory
The alarm status of the temperature.
Enumeration
Enumerated Values:
1temperatureNormal
2temperatureWarnLow
3temperatureWarnHigh
4temperatureAlarmLow
5temperatureAlarmHigh
.1.3.6.1.4.1.3808.1.1.7.5.7.1.6
bmProbesTemperature mandatory
The temperature record, measure in 0.1 degree C.
Integer32
Constraints:
range: -40-100
.1.3.6.1.4.1.3808.1.1.7.5.7.1.7

bmProbesResTable

table mandatory
.1.3.6.1.4.1.3808.1.1.7.5.9 · 1 row entry · 8 columns
The batteries resistance information.
bmProbesResEntry entry .1.3.6.1.4.1.3808.1.1.7.5.9.1
The batteries resistance information.
Indexes
bmProbesResIndex
Column Syntax OID
bmProbesResIndex mandatory
The index of the BmProbesResEntry entry.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.5.9.1.1
bmProbesResPackIndex mandatory
The battery pack number the battery resistance reading belongs to.
Integer32
Constraints:
range: 1-64
.1.3.6.1.4.1.3808.1.1.7.5.9.1.2
bmProbesResStringIndex mandatory
The battery string number the battery resistance reading belongs to.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.3808.1.1.7.5.9.1.3
bmProbesResBattIndex mandatory
The index to the battery.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.5.9.1.4
bmProbesResProbeIndex mandatory
The index to the probe.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.5.9.1.5
bmProbesResAlarmStatus mandatory
The alarm status of the battery resistance.
Enumeration
Enumerated Values:
1resistanceNormal
2resistanceWarnLow
3resistanceWarnHigh
4resistanceAlarmLow
5resistanceAlarmHigh
.1.3.6.1.4.1.3808.1.1.7.5.9.1.6
bmProbesResistance mandatory
The resistance of the battery, unit in 0.01 mOhm.
Integer32
Constraints:
range: 0-100
.1.3.6.1.4.1.3808.1.1.7.5.9.1.7
bmProbesResHealth mandatory
The resistance health status, unit in percentage.
Integer32
Constraints:
range: 0-100
.1.3.6.1.4.1.3808.1.1.7.5.9.1.8

bmStringsTable

table mandatory
.1.3.6.1.4.1.3808.1.1.7.10.3 · 1 row entry · 3 columns
Allows for getting of status of strings.
bmStringsEntry entry .1.3.6.1.4.1.3808.1.1.7.10.3.1
The status of strings installation to gather status from.
Indexes
bmStringsIndex
Column Syntax OID
bmStringsIndex mandatory
Strings table index
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.7.10.3.1.1
bmStringsPackIndex mandatory
The battery pack number the string installed.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.7.10.3.1.2
bmStringsProbeCount mandatory
The probe number installed in string.
Integer32
Constraints:
range: 1-960
.1.3.6.1.4.1.3808.1.1.7.10.3.1.3

bmStringsVoltageTable

table mandatory
.1.3.6.1.4.1.3808.1.1.7.10.5 · 1 row entry · 6 columns
Allows for getting of voltage of strings.
bmStringsVoltageEntry entry .1.3.6.1.4.1.3808.1.1.7.10.5.1
The status of string voltage installation to gather status from.
Indexes
bmStringsVoltageIndex
Column Syntax OID
bmStringsVoltageIndex mandatory
Strings table index
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.7.10.5.1.1
bmStringsVoltagePackIndex mandatory
The battery pack number the string installed.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.1.1.7.10.5.1.2
bmStringsVoltageAlarmStatus mandatory
The string voltage alarm status.
Enumeration
Enumerated Values:
1stringvoltageNormal
2stringvoltageWarnLow
3stringvoltageWarnHigh
4stringvoltageAlarmLow
5stringvoltageAlarmHigh
.1.3.6.1.4.1.3808.1.1.7.10.5.1.3
bmStringsVoltage mandatory
Getting this oid to get string voltage, unit in 10mV (0.01 V).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.7.10.5.1.4
bmStringsVoltageSocAlarmStatus mandatory
The string soc alarm status.
Enumeration
Enumerated Values:
1stringvoltageSocNormal
2stringvoltageSocWarnLow
3stringvoltageSocWarnHigh
4stringvoltageSocAlarmLow
5stringvoltageSocAlarmHigh
.1.3.6.1.4.1.3808.1.1.7.10.5.1.5
bmStringsVoltageSoc mandatory
Getting this oid to get string soc, unit in 1%.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.7.10.5.1.6

envir2IdentTable

table mandatory
.1.3.6.1.4.1.3808.1.1.8.1.2 · 1 row entry · 5 columns
A table of environment sensor identification information.
envir2IdentEntry entry .1.3.6.1.4.1.3808.1.1.8.1.2.1
Identification data from environment sensor being queried.
Indexes
envir2IdentIndex
Column Syntax OID
envir2IdentIndex mandatory
The index to the environment sensor table entry.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.3808.1.1.8.1.2.1.1
envir2IdentModulePosition mandatory
The position of environment sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.1.2.1.2
envir2IdentName mandatory
The name of the environment sensor.
The maximum string size is device dependent.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.8.1.2.1.3
envir2IdentLocation mandatory
The location of the environment sensor.
The maximum string size is device dependent.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.8.1.2.1.4
envir2IdentSerialNumber mandatory
The serial number of the environment sensor.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.8.1.2.1.5

envir2TempTable

table mandatory
.1.3.6.1.4.1.3808.1.1.8.2.3 · 1 row entry · 7 columns
A table of environment sensor identification information in temperature.
envir2TempEntry entry .1.3.6.1.4.1.3808.1.1.8.2.3.1
Identification data from environment sensor being queried.
Indexes
envir2TemperatureIndex
Column Syntax OID
envir2TemperatureIndex mandatory
The index to the environment sensor table entry.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.3808.1.1.8.2.3.1.1
envir2TempModulePosition mandatory
The position of environment sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.2.3.1.2
envir2Temperature mandatory
The environment temperature expressed in 1/100.
The value is determined by temperature unit which can be changed in envir2TempUnit.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.2.3.1.3
envir2TempHighThreshold mandatory
The high temperature threshold of the environment sensor.
The value is determined by temperature unit which can be changed in envir2TempUnit.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.2.3.1.4
envir2TempLowThreshold mandatory
The low temperature threshold of the environment sensor.
The value is determined by temperature unit which can be changed in envir2TempUnit.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.2.3.1.5
envir2TempRateOfChange mandatory
The rate of change of the temperature.
The value expressed in degree per 5 minute.
The value is determined by temperature unit which can be changed in envir2TempUnit.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.2.3.1.6
envir2TempHysteresis mandatory
The number of degrees beyond the temperature thresholds
at which an active temperature alarm will be cleared.
This configuration setting applies to all temperature thresholds.
The value is determined by temperature …
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.2.3.1.7

envir2HumidTable

table mandatory
.1.3.6.1.4.1.3808.1.1.8.3.2 · 1 row entry · 7 columns
A table of environment sensor identification information in humidity.
envir2HumidEntry entry .1.3.6.1.4.1.3808.1.1.8.3.2.1
Identification data from environment sensor being queried.
Indexes
envir2HumidityIndex
Column Syntax OID
envir2HumidityIndex mandatory
The index to the environment sensor table entry.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.3808.1.1.8.3.2.1.1
envir2HumidModulePosition mandatory
The position of environment sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.3.2.1.2
envir2Humidity mandatory
The environment relative humidity expressed in 1/100.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.3.2.1.3
envir2HumidHighThreshold mandatory
The high relative humidity threshold of the environment sensor.
The value expressed in persentage.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.3.2.1.4
envir2HumidLowThreshold mandatory
The low relative humidity threshold of the environment sensor.
The value expressed in persentage.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.3.2.1.5
envir2HumidRateOfChange mandatory
The rate of change of the relative humidity.
The value expressed in persentage per 5 minute.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.3.2.1.6
envir2HumidHysteresis mandatory
The number of degrees beyond the relative humidity thresholds
at which an active relative humidity alarm will be cleared.
This configuration setting applies to all relative humidity
thresholds.
Units are displayed in pe…
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.3.2.1.7

envir2ContactTable

table mandatory
.1.3.6.1.4.1.3808.1.1.8.4.2 · 1 row entry · 6 columns
Allows for getting of information of each contact of the environment sensor.
envir2ContactEntry entry .1.3.6.1.4.1.3808.1.1.8.4.2.1
This gives access to contact entries
Indexes
envir2ContactIndex
Column Syntax OID
envir2ContactIndex mandatory
The index to the contact of the environment sensor.
Integer32
Constraints:
range: 1-32
.1.3.6.1.4.1.3808.1.1.8.4.2.1.1
envir2ContactModulePosition mandatory
The position of environment sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.4.2.1.2
envir2ContactModuleNumber mandatory
The numeric contact ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.8.4.2.1.3
envir2ContactName mandatory
Getting or setting the name of the contact of the environment sensor.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.8.4.2.1.4
envir2ContactStatus mandatory
Getting this OID will return the Contact Status.
Enumeration
Enumerated Values:
1contactNormal
2contactAbnormal
.1.3.6.1.4.1.3808.1.1.8.4.2.1.5
envir2ContactNormalState mandatory
Set the contact normal state.
Enumerationr/w
Enumerated Values:
1normalOpen
2normalClose
.1.3.6.1.4.1.3808.1.1.8.4.2.1.6

currIdentTable

table mandatory
.1.3.6.1.4.1.3808.1.1.50.1.6 · 1 row entry · 4 columns
Current probe identification table.
currIdentEntry entry .1.3.6.1.4.1.3808.1.1.50.1.6.1
Current probe identification entry.
Indexes
currIdentIndex
Column Syntax OID
currIdentIndex mandatory
The current probe ident index.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.50.1.6.1.1
currIdentName mandatory
The current probe ident name.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.50.1.6.1.2
currIdentLocation mandatory
The current probe ident location.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.50.1.6.1.3
currIdentMeasureNum mandatory
Number of the current flow measure by the current probe.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.1.6.1.4

currConfigTable

table mandatory
.1.3.6.1.4.1.3808.1.1.50.2.2 · 1 row entry · 14 columns
Table provides current flow's configuration parameters.
currConfigEntry entry .1.3.6.1.4.1.3808.1.1.50.2.2.1
The current flow's configration parameters entry.
Indexes
currConfigIndex
Column Syntax OID
currConfigIndex mandatory
Entry index.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.50.2.2.1.1
currConfigCurrentSensorRating mandatory
Connecting current sensor element's rating, unit in 1 A.
Sets to 0 if you do not use current sensor for this measure channel.
Gets as 0 if this measure channel had not used.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.2
currConfigChargeCurrentWarningLow mandatory
Warning threshold for low charge current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.3
currConfigChargeCurrentWarningHigh mandatory
Warning threshold for high charge current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.4
currConfigChargeCurrentAlarmLow mandatory
Alarm threshold for low charge current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.5
currConfigChargeCurrentAlarmHigh mandatory
Alarm threshold for high charge current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.6
currConfigDischargeCurrentWarningLow mandatory
Warning threshold for low discharge current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.7
currConfigDischargeCurrentWarningHigh mandatory
Warning threshold for high discharge current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.8
currConfigDischargeCurrentAlarmLow mandatory
Alarm threshold for low discharge current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.9
currConfigDischargeCurrentAlarmHigh mandatory
Alarm threshold for high discharge current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.10
currConfigRMSCurrentWarninigLow mandatory
Warning threshold for low RMS current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.11
currConfigRMSCurrentWarningHigh mandatory
Warning threshold for high RMS current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.12
currConfigRMSCurrentAlarmLow mandatory
Alarm threshold for low RMS current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.13
currConfigRMSCurrentAlarmHigh mandatory
Alarm threshold for high RMS current, unit in 0.01A.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.2.2.1.14

currMeasureTable

table mandatory
.1.3.6.1.4.1.3808.1.1.50.3.2 · 1 row entry · 7 columns
Table for the current probe's measurement.
currMeasureEntry entry .1.3.6.1.4.1.3808.1.1.50.3.2.1
The status of current sensors installation to gather status from.
Indexes
currMeasureIndex
Column Syntax OID
currMeasureIndex mandatory
The current measurement's index.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.3808.1.1.50.3.2.1.1
currMeasureIdentName mandatory
The current measurement's current probe name.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.50.3.2.1.2
currMeasureDescription mandatory
Current flow measurement's description.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.1.1.50.3.2.1.3
currMeasureAlarmStatus mandatory
The current alarm status.
For battery system, abnormal value can be (2) to (9).
For AC measure condition, abnormal value can be (50) to (53).
Enumeration
Enumerated Values:
1currentNormal
2chargeCurrentWarnLow
3chargeCurrentWarnHigh
4chargeCurrentAlarmLow
5chargeCurrentAlarmHigh
6dischargeCurrentWarnLow
7dischargeCurrentWarnHigh
8dischargeCurrentAlarmLow
9dischargeCurrentAlarmHigh
10rmsCurrentWarnLow
11rmsCurrentWarnHigh
12rmsCurrentAlarmLow
13rmsCurrentAlarmHigh
.1.3.6.1.4.1.3808.1.1.50.3.2.1.4
currMeasureChargingState mandatory
For battery system to get battery charging state.
Enumeration
Enumerated Values:
1batteryCharging
2batteryDischarging
3notDetermine
.1.3.6.1.4.1.3808.1.1.50.3.2.1.5
currMeasureCurrent mandatory
Getting this oid to get current measurement, unit in 10mA (0.01 A).
For battery system, negative value indicates the discharge state.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3808.1.1.50.3.2.1.6
currMeasureFunction mandatory
Getting this oid to check the configuration be matched with actual installation.
Setting this oid to tell system what the measure target is.
For the DC current(prefix as dc), charge/discharge threshold would be consid…
Enumerationr/w
Enumerated Values:
1dcBatteryStringA
2dcBatteryStringB
3dcBatteryStringC
4dcBatteryStringD
5dcBatteryStringE
6dcBatteryStringF
7dcBatteryStringG
8dcBatteryStringH
9dcReserved
20acInputCurrent
.1.3.6.1.4.1.3808.1.1.50.3.2.1.7
.1.3.6.1.4.1.3808.2.1.2 · 1 row entry · 5 columns
A list of receivers to send traps to. The numbers of
entries are given by the value of mconfigNumTrapAccepters.
mconfigTrapAccepterEntry entry .1.3.6.1.4.1.3808.2.1.2.1
The receivers to send traps to.
Indexes
trapIndex
Column Syntax OID
trapIndex mandatory
The trap receiver entry index.
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.3808.2.1.2.1.1
accepterAddr mandatory
The trap receiver IP address.
RFC1155-SMIIpAddressr/w
Textual Convention: RFC1155-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.3808.2.1.2.1.2
communityString mandatory
The trap receiver community name.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.3808.2.1.2.1.3
severityDegree mandatory
The trap receiver severity level. Traps are marked in severity level
as informational(1), warning(2), severe(3). Only send the traps of
equal or greater severity than this value to the receiver.
Enumeration
Enumerated Values:
1information
2warning
3severe
.1.3.6.1.4.1.3808.2.1.2.1.4
accepterActive mandatory
A receiver will accept traps if yes, and none if no.
Enumerationr/w
Enumerated Values:
1yes
2no