ePDUOutletStatusCommandPending
CPS-MIB ·
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.5
Object
column
mandatory
Enumeration
Getting this variable will return the command pending state of the outlet. If a command is pending on the outlet, the outletStatusCommandPending (1) value will be returned. If there is not a command pending on the outlet, the outletStatusNoCommandPending (2) will be returned.
Context
- MIB
- CPS-MIB
- OID
.1.3.6.1.4.1.3808.1.1.3.3.5.1.1.5- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- ePDUOutletStatusEntry
- Table
- ePDUOutletStatusTable
- Siblings
- 13
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | outletStatusCommandPending |
2 | outletStatusNoCommandPending |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ePDUOutletStatusIndex mandatory The index to the outlet entry. | column | Integer32 | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.1 |
| ePDUOutletStatusPeakPower mandatory The peak power consumption of the Rack PDU load in watts.
This value can be reset by setting the oid
ePDUOutletConfigMonitoredPeakLoadReset to reset (2) | column | RFC1155-SMIGauge | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.10 |
| ePDUOutletStatusPeakPowerTime mandatory Get this oid shows the date and time that peak power consumption occurred | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.11 |
| ePDUOutletStatusPeakPowerStart mandatory Get this oid shows the date and time that peak power consumption started | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.12 |
| ePDUOutletStatusEnergy mandatory Energy meter measuring Rack PDU load energy consumption
in tenths of kilowatt-hours. This value can be reset by setting
the oid ePDUOutletConfigMonitoredEnergyReset to reset (2) | column | RFC1155-SMIGauge | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.13 |
| ePDUOutletStatusEnergyStartTime mandatory Indicates the date and time of the last device energy
meter reset | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.14 |
| ePDUOutletStatusOutletName mandatory The name of the outlet. The maximum string size is device dependent.
This OID is provided for informational purposes only. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.2 |
| ePDUOutletStatusOutletPhase mandatory The phase/s associated with this outlet.
For single phase devices, this object will always
return phase1(1).
For 3-phase devices, this object will r… | column | Enumeration | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.3 |
| ePDUOutletStatusOutletState mandatory Getting this variable will return the outlet state. If
the outlet is on, the outletStatusOn (1) value will be returned.
If the outlet is off, the outletStatusOff (2) value will b… | column | Enumeration | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.4 |
| ePDUOutletStatusOutletBank mandatory The bank associated with this outlet. | column | Integer32 | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.6 |
| ePDUOutletStatusLoad mandatory Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU
in tenths of Amps. | column | RFC1155-SMIGauge | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.7 |
| ePDUOutletStatusActivePower mandatory Getting this OID will return the measured Outlet load for an Outlet Monitored Rack PDU
in watts | column | RFC1155-SMIGauge | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.8 |
| ePDUOutletStatusAlarm mandatory Getting this OID will return the current outlet alarm | column | Enumeration | .1.3.6.1.4.1.3808.1.1.3.3.5.1.1.9 |