ePDU2DeviceConfigCurrentLowLoadThreshold
CPS-MIB ·
.1.3.6.1.4.1.3808.1.1.6.3.2.1.8
Object
column
mandatory
r/w
Integer32
User-defined low current draw alarm threshold, measured in Amps.
Context
- MIB
- CPS-MIB
- OID
.1.3.6.1.4.1.3808.1.1.6.3.2.1.8- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- ePDU2DeviceConfigEntry
- Table
- ePDU2DeviceConfigTable
- Siblings
- 14
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ePDU2DeviceConfigIndex mandatory The index to the Rack PDU table entry. | column | Integer32 | .1.3.6.1.4.1.3808.1.1.6.3.2.1.1 |
| ePDU2DeviceConfigCurrentOverloadThreshold mandatory User-defined current overload threshold, measured in Amps. | column | Integer32 | .1.3.6.1.4.1.3808.1.1.6.3.2.1.10 |
| ePDU2DeviceConfigPeakLoadReset mandatory Setting this OID to resetAll (2) will cause the existing peak current value
of Rack PDU and its outlets to be replaced by the current load current value.
Setting this OID to reset… | column | Enumeration | .1.3.6.1.4.1.3808.1.1.6.3.2.1.11 |
| ePDU2DeviceConfigEnergyReset mandatory Setting this OID to resetAll (2) will cause the device energy meter value
to be reset to zero.
Setting this OID to resetDevice (3) to reset the Rack PDU only.
Setting this OID to… | column | Enumeration | .1.3.6.1.4.1.3808.1.1.6.3.2.1.12 |
| ePDU2DeviceConfigPowerLowLoadThreshold mandatory User-defined low power draw alarm threshold, measured in Watts. | column | Integer32 | .1.3.6.1.4.1.3808.1.1.6.3.2.1.13 |
| ePDU2DeviceConfigPowerNearOverloadThreshold mandatory User-defined near overload power threshold, measured in Watts. | column | Integer32 | .1.3.6.1.4.1.3808.1.1.6.3.2.1.14 |
| ePDU2DeviceConfigPowerOverloadThreshold mandatory User-defined power overload threshold, measured in Watts. | column | Integer32 | .1.3.6.1.4.1.3808.1.1.6.3.2.1.15 |
| ePDU2DeviceConfigModuleIndex mandatory The Rack PDU numeric ID. | column | Integer32 | .1.3.6.1.4.1.3808.1.1.6.3.2.1.2 |
| ePDU2DeviceConfigName mandatory A user-defined string identifying the name of Rack PDU. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.6.3.2.1.3 |
| ePDU2DeviceConfigLocation mandatory A user-defined string identifying the location of the Rack PDU. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.6.3.2.1.4 |
| ePDU2DeviceConfigContact mandatory A user-defined string identifying the person to contact of the Rack PDU. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3808.1.1.6.3.2.1.5 |
| ePDU2DeviceConfigDisplayOrientation mandatory Getting this OID will return the intended physical orientation of the Seven-Segment Display.
displayNormal(1) indicates Normal.
displayReverse(2)indicates Upside-Do… | column | Enumeration | .1.3.6.1.4.1.3808.1.1.6.3.2.1.6 |
| ePDU2DeviceConfigColdstartDelay mandatory The amount of delay, measured in seconds, between
when power is provided to the Rack PDU and when
the Rack PDU provides basic master power to the
outlets.
Allowed v… | column | Integer32 | .1.3.6.1.4.1.3808.1.1.6.3.2.1.7 |
| ePDU2DeviceConfigCurrentNearOverloadThreshold mandatory User-defined near overload current threshold, measured in Amps. | column | Integer32 | .1.3.6.1.4.1.3808.1.1.6.3.2.1.9 |