CPDU-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
26
Rows
26
Columns
224

pduNamePlateTable

table mandatory
.1.3.6.1.4.1.318.1.1.32.1.2 · 1 row entry · 16 columns
A table of PDU nameplate data
pduNamePlateEntry entry .1.3.6.1.4.1.318.1.1.32.1.2.1
Nameplate data from the PDU being queried. The numbers of entries equals the value of pduNamePlateTableSize.
Indexes
pduNamePlateIndex
Column Syntax OID
pduNamePlateIndex mandatory
The index of the PDU nameplate table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.1.2.1.1
pduNamePlateName mandatory
A user-defined string identifying the PDU
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.1.2.1.2
pduNamePlateLocation mandatory
A user-defined string identifying the location of PDU
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.1.2.1.3
pduNamePlateInetAddressType mandatory
The type of address format
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.1.2.1.4
pduNamePlateIPAddress mandatory
The current IP address. A value of 0.0.0.0 indicates an error or an unset option
INET-ADDRESS-MIBInetAddress
Textual Convention: INET-ADDRESS-MIBInetAddress OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.318.1.1.32.1.2.1.5
pduNamePlateInetNetMask mandatory
The current netmask. A value of 0.0.0.0 indiates an error or an unset option
INET-ADDRESS-MIBInetAddress
Textual Convention: INET-ADDRESS-MIBInetAddress OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.318.1.1.32.1.2.1.6
pduNamePlateInetGateway mandatory
The current gateway. A value of 0.0.0.0 indicates an error or an unset option
INET-ADDRESS-MIBInetAddress
Textual Convention: INET-ADDRESS-MIBInetAddress OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.318.1.1.32.1.2.1.7
pduNamePlateMACAddress mandatory
The assigned MAC address for the PDU
SNMPv2-TCMacAddress
Textual Convention: SNMPv2-TCMacAddress OctetString
Type Constraints:
range: 6
.1.3.6.1.4.1.318.1.1.32.1.2.1.8
pduNamePlateUTCTimeOffset mandatory
The difference in hours and minutes from Coordinated Universal
Time(UTC) for the time used in a particular time zone
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.1.2.1.9
pduNamePlateModelNumber mandatory
The PDU model number
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.1.2.1.10
pduNamePlatePartNumber mandatory
The PDU part number
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.1.2.1.11
pduNamePlateSerialNumber mandatory
The PDU serial number
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.1.2.1.12
pduNamePlateDateofManufacture mandatory
The date the PDU was manufactured in mm/dd/yyyy format
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.1.2.1.13
pduNamePlateFirmwareVersion mandatory
The PDU firmware version
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.1.2.1.14
pduNamePlateFirmwareVersionTimeStamp mandatory
Timestamp of when the PDU firmware was last updated
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.1.2.1.15
pduNamePlateType mandatory
The type of input
Enumeration
Enumerated Values:
1singlePhase
2delta
3wye
.1.3.6.1.4.1.318.1.1.32.1.2.1.16

pduUnitConfigTable

table mandatory
.1.3.6.1.4.1.318.1.1.32.2.2 · 1 row entry · 20 columns
A table of PDU configuration data
pduUnitConfigEntry entry .1.3.6.1.4.1.318.1.1.32.2.2.1
Configuration data from the PDU being queried. The number of entries equals the value of pduUnitTableSize
Indexes
pduUnitConfigIndex
Column Syntax OID
pduUnitConfigIndex mandatory
The index of the PDU Unit Config Entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.2.2.1.1
pduUnitConfigName mandatory
A user-defined string identifying the PDU
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.2.1.2
pduUnitConfigLocation mandatory
A user-defined string identifying the location of the PDU
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.2.1.3
pduUnitConfigDisplayOrientation mandatory
Indicates the intended physical orientation of the oLED display
displayNormal (1) indicates normal orientation.
displayReverse (2) indicates upside down orientation
NOTE:
This OID is compatible only with the two displa…
Enumerationr/w
Enumerated Values:
1displayNormal
2displayReverse
.1.3.6.1.4.1.318.1.1.32.2.2.1.4
pduUnitConfigOledDisplayControl mandatory
Used to turn oled display On or Off
displayOff (1) to turn dispaly OFF.
displayOn (2) to turn dispaly ON
Enumerationr/w
Enumerated Values:
1displayOff
2displayOn
.1.3.6.1.4.1.318.1.1.32.2.2.1.5
pduUnitConfigColdstartDelay mandatory
The amount of time, specified in seconds, between when power
is provided to the PDU and when the PDU start providing basic master
power to the outlets
Unsigned32r/w
Constraints:
range: 0-3600
.1.3.6.1.4.1.318.1.1.32.2.2.1.6
pduUnitConfigGlobalOutletStateOnStartup mandatory
The outlet state on device startup; applies to all outlets
unless overridden at the outlet level
Enumerationr/w
Enumerated Values:
0off
1on
2lastKnownState
.1.3.6.1.4.1.318.1.1.32.2.2.1.7
pduUnitConfigLowerCriticalThreshold mandatory
User-defined lower critical unit active power alarm threshold measured in Watts
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.2.2.1.8
pduUnitConfigLowerWarningThreshold mandatory
User-defined lower non-critical (warning) unit active power alarm threshold measured in Watts
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.2.2.1.9
pduUnitConfigUpperCriticalThreshold mandatory
User-defined upper critical unit active power alarm threshold measured in Watts
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.2.2.1.10
pduUnitConfigUpperWarningThreshold mandatory
User-defined upper non-critical (warning) unit active power alarm threshold measured in Watts
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.2.2.1.11
pduUnitConfigAlarmResetThreshold mandatory
The hysteresis used for deassertions in Watts
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.2.2.1.12
pduUnitConfigAlarmStateChangeDelay mandatory
The delay measured in samples before a state is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecutive…
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.2.2.1.13
pduUnitConfigEnabledThresholds mandatory
A bit string indicating which alarm thresholds are enabled
Bitsr/w
Enumerated Values:
0lowerCritical
1lowerWarning
2upperWarning
3upperCritical
.1.3.6.1.4.1.318.1.1.32.2.2.1.14
pduUnitConfigPeakPowerReset mandatory
Setting this OID to reset (2) will cause the existing peak power value
to be replaced by the current load power value. Getting this OID will
do nothing and return the noOperation(1) value.
Enumerationr/w
Enumerated Values:
1noOperation
2reset
.1.3.6.1.4.1.318.1.1.32.2.2.1.15
pduUnitConfigEnergyReset mandatory
Setting this OID to reset (2) will cause the device energy meter value
to be reset to zero. Getting this OID in models that support this
feature will do nothing and return the noOperation(1) value. Models
that do not…
Enumerationr/w
Enumerated Values:
1noOperation
2reset
3notSupported
.1.3.6.1.4.1.318.1.1.32.2.2.1.16
pduUnitConfigOutletPeakPowerReset mandatory
Setting this OID to reset (2) will cause the outlet peak power meter value
to be reset to zero. Getting this OID in models that support this
feature will do nothing and return the noOperation(1) value. Models
that do…
Enumerationr/w
Enumerated Values:
1noOperation
2reset
3notSupported
.1.3.6.1.4.1.318.1.1.32.2.2.1.17
pduUnitConfigOutletEnergyReset mandatory
Setting this OID to reset (2) will cause the outlet energy meter value
to be reset to zero. Getting this OID in models that support this
feature will do nothing and return the noOperation(1) value. Models
that do not…
Enumerationr/w
Enumerated Values:
1noOperation
2reset
3notSupported
.1.3.6.1.4.1.318.1.1.32.2.2.1.18
pduUnitConfigSsh mandatory
Setting this OID to off(0) will disable the SSH connection. Setting this OID to on(1) will enable the SSH connection.
Enumerationr/w
Enumerated Values:
0off
1on
.1.3.6.1.4.1.318.1.1.32.2.2.1.19
pduUnitConfigResetNetworkManagementCard mandatory
Getting this OID will return noOperation(0). Setting this OID to reset(1) will reset NMC.
Enumerationr/w
Enumerated Values:
0noOperation
1reset
.1.3.6.1.4.1.318.1.1.32.2.2.1.20

pduUnitPropertiesTable

table mandatory
.1.3.6.1.4.1.318.1.1.32.2.3 · 1 row entry · 16 columns
A table of PDU properties
pduUnitPropertiesEntry entry .1.3.6.1.4.1.318.1.1.32.2.3.1
A unit properties entry containing objects for a particular unit.
Indexes
pduUnitPropertiesIndex
Column Syntax OID
pduUnitPropertiesIndex mandatory
The index of the PDU properties table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.2.3.1.1
pduUnitPropertiesName mandatory
A user-defined string identifying the PDU
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.3.1.2
pduUnitPropertiesOutletCount mandatory
The total number of outlets on the PDU
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.2.3.1.3
pduUnitPropertiesSwitchedOutletCount mandatory
The total number of switched outlets on the PDU
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.2.3.1.4
pduUnitPropertiesMeteredOutletCount mandatory
The total number of metered outlets on the PDU
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.2.3.1.5
pduUnitPropertiesInputPhaseCount mandatory
The total number of phases on the PDU
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.2.3.1.6
pduUnitPropertiesCircuitBreakerCount mandatory
The total number of circuit breaker on the PDU
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.318.1.1.32.2.3.1.7
pduUnitPropertiesMaxExternalSensorCount mandatory
The maximum number of external sensors that can be connected to the PDU
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.318.1.1.32.2.3.1.8
pduUnitPropertiesConnExternalSensorCount mandatory
The current number of external sensors connected to the PDU
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.318.1.1.32.2.3.1.9
pduUnitPropertiesRatedVoltage mandatory
The PDU voltage rating in Volts
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.3.1.10
pduUnitPropertiesRatedMaxCurrent mandatory
The PDU current rating in Amps
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.3.1.11
pduUnitPropertiesRatedFrequency mandatory
The PDU frequency rating in Hz
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.3.1.12
pduUnitPropertiesRatedPower mandatory
The PDU VA (VoltAmps) rating.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.3.1.13
pduUnitPropertiesOrientation mandatory
The PDU orientation
Enumeration
Enumerated Values:
1horizontal
2vertical
.1.3.6.1.4.1.318.1.1.32.2.3.1.14
pduUnitPropertiesOutletLayout mandatory
The outlet layout for the PDU. Getting this OID will return outlet layout for the device.
seqPhaseToNeutral(1) indicates outlet layout as follows:
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,...
seqPhaseToPhase(2) indicates outlet la…
Enumeration
Enumerated Values:
1seqPhaseToNuetral
2seqPhaseToPhase
3seqPhToNeu21PhToPh
4seqPhToPhGrouped
5seqPhToNGrouped
6seqPToN1516PToPGrouped
7seqPhToPh2xGrouped
8seqPhToN2xGrouped
9seqNotApplicable
.1.3.6.1.4.1.318.1.1.32.2.3.1.15
pduUnitPropertiesCascadeMemberType mandatory
The cascading member type
Enumeration
Enumerated Values:
1standalone
2parent
3child
.1.3.6.1.4.1.318.1.1.32.2.3.1.16

pduUnitStatusTable

table mandatory
.1.3.6.1.4.1.318.1.1.32.2.4 · 1 row entry · 12 columns
A table of PDU status information
pduUnitStatusEntry entry .1.3.6.1.4.1.318.1.1.32.2.4.1
Status information from the PDU being queried
Indexes
pduUnitStatusIndex
Column Syntax OID
pduUnitStatusIndex mandatory
The index of the PDU status table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.2.4.1.1
pduUnitStatusName mandatory
A user-defined string identifying the PDU
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.4.1.2
pduUnitStatusLoadState mandatory
Returns the present load status of the PDU based on Active Power.
Enumeration
Enumerated Values:
1upperCritical
2upperWarning
3lowerWarning
4lowerCritical
5normal
.1.3.6.1.4.1.318.1.1.32.2.4.1.3
pduUnitStatusActivePower mandatory
Returns power consumption, in Watts(W),
of the PDU being queried.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.2.4.1.4
pduUnitStatusApparentPower mandatory
Returns power consumption, in Volt-Amps(VA)
of the PDU load being queried.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.2.4.1.5
pduUnitStatusPeakPower mandatory
Returns peak power consumption, in Watts(W),
of the PDU being queried.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.2.4.1.6
pduUnitStatusPeakPowerTimestamp mandatory
Indicates the date and time that peak power consumption occurred
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.4.1.7
pduUnitStatusPeakPowerStartTime mandatory
Indicates the date and time of the last device peak power reset
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.4.1.8
pduUnitStatusEnergy mandatory
Returns total energy consumed, in tenths of Kilowatt-Hours(kWh), of the PDU over its lifetime.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.2.4.1.9
pduUnitStatusResettableEnergy mandatory
A user resettable energy meter measuring PDU energy consumption
in tenths of kilowatt-hours(kWh).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.2.4.1.10
pduUnitStatusEnergyStartTime mandatory
Indicates the date and time of the last device energy meter reset
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.4.1.11
pduUnitStatusOutletsEnergyStartTime mandatory
Indicates the date and time of the last outlets energy meter reset
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.2.4.1.12

pduUnitPsTable

table mandatory
.1.3.6.1.4.1.318.1.1.32.2.5 · 1 row entry · 4 columns
Aggregate Object with number of entries equal to number of PDUs and Power share
pduUnitPsEntry entry .1.3.6.1.4.1.318.1.1.32.2.5.1
The Power share entry containing the avaliable, input, output etc.
Indexes
pduUnitPsIndex
Column Syntax OID
pduUnitPsIndex mandatory
The index of the PDU Power share table entry
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.318.1.1.32.2.5.1.1
pduUnitPsSupportUpstreamStatus mandatory
Power share support status on upstream PDU
Enumeration
Enumerated Values:
0notAvailable
1available
.1.3.6.1.4.1.318.1.1.32.2.5.1.2
pduUnitPsSupportDownstreamStatus mandatory
Power share support status on downstream PDU
Enumeration
Enumerated Values:
0notAvailable
1available
.1.3.6.1.4.1.318.1.1.32.2.5.1.3
pduUnitPsOptMode mandatory
Operating power status.
Enumeration
Enumerated Values:
0backupPower
1mainPower
.1.3.6.1.4.1.318.1.1.32.2.5.1.4
.1.3.6.1.4.1.318.1.1.32.3.2 · 1 row entry · 17 columns
A table of PDU Input Phase configuration data
pduInputPhaseConfigEntry entry .1.3.6.1.4.1.318.1.1.32.3.2.1
An input phase entry containing objects for a particular input phase.
Indexes
pduUnitConfigIndex pduInputPhaseConfigIndex
Column Syntax OID
pduInputPhaseConfigIndex mandatory
The index of the PDU Input Phase configuration table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.3.2.1.1
pduInputPhaseConfigCount mandatory
The total number of Input Phases
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.3.2.1.2
pduInputPhaseConfigOverloadRestriction mandatory
This OID controls the behavior of a Switched PDU Input Phase when an
overload condition is possible and additional outlets are requested
to be turned on. Setting this OID to alwaysAllowTurnON (1) will always
allow th…
Enumerationr/w
Enumerated Values:
1alwaysAllowTurnOn
2restrictOnUpperWarning
3restrictOnUpperCritical
4notSupported
.1.3.6.1.4.1.318.1.1.32.3.2.1.3
pduInputPhaseConfigCurrentLowerCriticalThreshold mandatory
User-defined lower critical input phase current alarm threshold in hundredths of Amps(A).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.3.2.1.4
pduInputPhaseConfigCurrentLowerWarningThreshold mandatory
User-defined lower non-critical (warning) input phase current alarm threshold in hundredths of Amps(A).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.3.2.1.5
pduInputPhaseConfigCurrentUpperCriticalThreshold mandatory
User-defined upper critical input phase current alarm threshold in hundredths of Amps(A).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.3.2.1.6
pduInputPhaseConfigCurrentUpperWarningThreshold mandatory
User-defined upper non-critical (warning) input phase current alarm threshold in hundredths of Amps(A).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.3.2.1.7
pduInputPhaseConfigVoltageLowerCriticalThreshold mandatory
User-defined lower critical input phase voltage alarm threshold in Volts(V).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.3.2.1.8
pduInputPhaseConfigVoltageLowerWarningThreshold mandatory
User-defined lower non-critical (warning) input phase voltage alarm threshold in Volts(V).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.3.2.1.9
pduInputPhaseConfigVoltageUpperCriticalThreshold mandatory
User-defined upper critical input phase voltage alarm threshold in Volts(V).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.3.2.1.10
pduInputPhaseConfigVoltageUpperWarningThreshold mandatory
User-defined upper non-critical (warning) input phase voltage alarm threshold in Volts(V).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.3.2.1.11
pduInputPhaseConfigCurrentAlarmResetThreshold mandatory
The hysteresis used for current alarm deassertions in hundredths of Amps(A).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.3.2.1.12
pduInputPhaseConfigCurrentAlarmStateChangeDelay mandatory
The delay measured in samples before a current state is asserted. If the
value is zero, then the state is asserted as soon as it is
detected; if it is non-zero, say n, then the assertion condition
must exist for n+1 …
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.3.2.1.13
pduInputPhaseConfigCurrentEnabledThresholds mandatory
A bit string indicating which current alarm thresholds are enabled.
Bitsr/w
Enumerated Values:
0lowerCritical
1lowerWarning
2upperWarning
3upperCritical
.1.3.6.1.4.1.318.1.1.32.3.2.1.14
pduInputPhaseConfigVoltageAlarmResetThreshold mandatory
The hysteresis used for voltage alarm deassertions in Volts(V).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.3.2.1.15
pduInputPhaseConfigVoltageAlarmStateChangeDelay mandatory
The delay measured in samples before a voltage state is asserted. If the
value is zero, then the state is asserted as soon as it is
detected; if it is non-zero, say n, then the assertion condition
must exist for n+1 …
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.3.2.1.16
pduInputPhaseConfigVoltageEnabledThresholds mandatory
A bit string indicating which voltage alarm thresholds are enabled.
Bitsr/w
Enumerated Values:
0lowerCritical
1lowerWarning
2upperWarning
3upperCritical
.1.3.6.1.4.1.318.1.1.32.3.2.1.17
.1.3.6.1.4.1.318.1.1.32.3.3 · 1 row entry · 2 columns
A table of PDU Input Phase properties
pduInputPhasePropertiesEntry entry .1.3.6.1.4.1.318.1.1.32.3.3.1
An input phase properties entry containing objects for a particular input phase.
Indexes
pduUnitPropertiesIndex pduInputPhasePropertiesIndex
Column Syntax OID
pduInputPhasePropertiesIndex mandatory
The index of the PDU Input Phase status entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.3.3.1.1
pduInputPhasePropertiesCount mandatory
The numeric Input Phase ID
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.3.3.1.2
.1.3.6.1.4.1.318.1.1.32.3.4 · 1 row entry · 9 columns
A table of PDU Input Phase status data
pduInputPhaseStatusEntry entry .1.3.6.1.4.1.318.1.1.32.3.4.1
An input phase status entry containing objects for a particular input phase.
Indexes
pduUnitStatusIndex pduInputPhaseStatusIndex
Column Syntax OID
pduInputPhaseStatusIndex mandatory
The index of the PDU Input Phase status entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.3.4.1.1
pduInputPhaseStatusCount mandatory
The numeric Input Phase ID
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.3.4.1.2
pduInputPhaseStatusCurrentState mandatory
Indicates the present current status of the PDU Phase in case of Y connection or PDU Line in case of Delta conneciton.
Enumeration
Enumerated Values:
1upperCritical
2upperWarning
3lowerWarning
4lowerCritical
5normal
.1.3.6.1.4.1.318.1.1.32.3.4.1.3
pduInputPhaseStatusVoltageState mandatory
Indicates the present voltage status of the PDU Input Phase being queried
Enumeration
Enumerated Values:
1upperCritical
2upperWarning
3lowerWarning
4lowerCritical
5normal
.1.3.6.1.4.1.318.1.1.32.3.4.1.4
pduInputPhaseStatusCurrent mandatory
Returns the current draw, in hundredths of Amps(A)
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.3.4.1.5
pduInputPhaseStatusVoltage mandatory
Returns the voltage, in Volts(V)
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.3.4.1.6
pduInputPhaseStatusActivePower mandatory
Returns power consumption, in Watts(W)
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.3.4.1.7
pduInputPhaseStatusApparentPower mandatory
Returns power consumption, in Volt-Amps(VA)
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.3.4.1.8
pduInputPhaseStatusPowerFactor mandatory
Returns the ratio of active to apparent power of the PDU.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.3.4.1.9
.1.3.6.1.4.1.318.1.1.32.4.2 · 1 row entry · 11 columns
A table of PDU Circuit Breaker configuration data
pduCircuitBreakerConfigEntry entry .1.3.6.1.4.1.318.1.1.32.4.2.1
A circuit breaker configuration entry containing objects for a particular circuit breaker.
Indexes
pduUnitConfigIndex pduCircuitBreakerConfigIndex
Column Syntax OID
pduCircuitBreakerConfigIndex mandatory
The index of the PDU Circuit Breaker configuration table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.4.2.1.1
pduCircuitBreakerConfigCount mandatory
The number of circuit breakers on the PDU
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.318.1.1.32.4.2.1.2
pduCircuitBreakerName mandatory
The label of the circuit breaker
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.4.2.1.3
pduCircuitBreakerConfigOverloadRestriction mandatory
This OID controls the behavior of a Switched PDU Circuit
Breaker when an overload condition is possible and additional
outlets are requested to be turned on. Setting this OID to
alwaysAllowTurnON (1) will always allo…
Enumerationr/w
Enumerated Values:
1alwaysAllowTurnOn
2restrictOnUpperWarning
3restrictOnUpperCritical
4notSupported
.1.3.6.1.4.1.318.1.1.32.4.2.1.4
pduCircuitBreakerConfigLowerCriticalThreshold mandatory
User-defined lower critical circuit breaker current alarm threshold in hundredths of Amps(A).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.4.2.1.5
pduCircuitBreakerConfigLowerWarningThreshold mandatory
User-defined lower non-critical (warning) circuit breaker current alarm threshold in hundredths of Amps(A).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.4.2.1.6
pduCircuitBreakerConfigUpperCriticalThreshold mandatory
User-defined upper critical circuit breaker current alarm threshold in hundredths of Amps(A).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.4.2.1.7
pduCircuitBreakerConfigUpperWarningThreshold mandatory
User-defined upper non-critical (warning) circuit breaker current alarm threshold in hundredths of Amps(A).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.4.2.1.8
pduCircuitBreakerConfigAlarmResetThreshold mandatory
The hysteresis used for deassertions in hundredths of Amps(A).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.4.2.1.9
pduCircuitBreakerConfigAlarmStateChangeDelay mandatory
The delay measured in samples before a state is asserted.
If the value is zero, then the state is asserted as soon
as it is detected; if it is non-zero, say n, then the
assertion condition must exist for n+1 consecut…
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.4.2.1.10
pduCircuitBreakerConfigEnabledThresholds mandatory
A bit string indicating which alarm thresholds are enabled.
Bitsr/w
Enumerated Values:
0lowerCritical
1lowerWarning
2upperWarning
3upperCritical
.1.3.6.1.4.1.318.1.1.32.4.2.1.11
.1.3.6.1.4.1.318.1.1.32.4.3 · 1 row entry · 4 columns
A table of PDU circuit breaker properties
pduCircuitBreakerPropertiesEntry entry .1.3.6.1.4.1.318.1.1.32.4.3.1
A circuit breaker properties entry containing objects for a particular circuit breaker.
Indexes
pduUnitPropertiesIndex pduCircuitBreakerPropertiesIndex
Column Syntax OID
pduCircuitBreakerPropertiesIndex mandatory
The index of the PDU Circuit Breaker properties table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.4.3.1.1
pduCircuitBreakerPropertiesCount mandatory
The number of Circuit Breakers
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.318.1.1.32.4.3.1.2
pduCircuitBreakerPropertiesInputLayout mandatory
This OID describes the outlet phase connections on
the referenced bank as follows:
seqPhase1ToNeutral(1) indicates that outlets attached
to circuit breaker are connected from Phase 1 to Neutral.
seqPhase2ToNeutral(2…
Enumeration
Enumerated Values:
1seqPhase1ToNeutral
2seqPhase2ToNeutral
3seqPhase3ToNeutral
4seqPhase1ToPhase2
5seqPhase2ToPhase3
6seqPhase3ToPhase1
.1.3.6.1.4.1.318.1.1.32.4.3.1.3
pduCircuitBreakerPropertiesCurrentRating mandatory
The number of Circuit Breakers
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.318.1.1.32.4.3.1.4
.1.3.6.1.4.1.318.1.1.32.4.4 · 1 row entry · 5 columns
A table of PDU circuit breaker status data
pduCircuitBreakerStatusEntry entry .1.3.6.1.4.1.318.1.1.32.4.4.1
A circuit breaker status entry containing objects for a particular circuit breaker.
Indexes
pduUnitStatusIndex pduCircuitBreakerStatusIndex
Column Syntax OID
pduCircuitBreakerStatusIndex mandatory
The index of the PDU Circuit Breaker status table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.4.4.1.1
pduCircuitBreakerStatusCount mandatory
The number of Circuit Breakers
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.318.1.1.32.4.4.1.2
pduCircuitBreakerLabel mandatory
The label on the PDU identifying the circuit breaker
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.4.4.1.3
pduCircuitBreakerStatusLoadState mandatory
Indicates the present load status of the PDU Circuit
Breaker being queried
Enumeration
Enumerated Values:
1upperCritical
2upperWarning
3lowerWarning
4lowerCritical
5normal
6off
.1.3.6.1.4.1.318.1.1.32.4.4.1.4
pduCircuitBreakerStatusCurrent mandatory
Returns the current draw, in hundredths of Amps(A), of the load on
the PDU Circuit Breaker being queried.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.4.4.1.5
.1.3.6.1.4.1.318.1.1.32.5.2 · 1 row entry · 6 columns
A table of PDU Switched Outlet configuration data
pduOutletSwitchedConfigEntry entry .1.3.6.1.4.1.318.1.1.32.5.2.1
An outlet configuration entry containing objects for a particular outlet.
Indexes
pduUnitConfigIndex pduOutletSwitchedConfigIndex
Column Syntax OID
pduOutletSwitchedConfigIndex mandatory
The index of the PDU Switched Outlet configuration table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.2.1.1
pduOutletSwitchedName mandatory
The user-defined name for the Switched Outlet
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.5.2.1.2
pduOutletSwitchedStateOnStartup mandatory
The outlet state on device startup; overrides
the global value pduUnitConfigGlobalOutletStateOnStartup.
Enumerationr/w
Enumerated Values:
0off
1on
2lastKnownState
.1.3.6.1.4.1.318.1.1.32.5.2.1.3
pduOutletSwitchedConfigPowerOnTime mandatory
The amount of delay, in seconds, between when power is
provided to outlets the outlet and when this outlet
starts providing power
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.5.2.1.4
pduOutletSwitchedConfigPowerOffTime mandatory
The amount of time, in seconds, this outlet will delay
powering off
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.5.2.1.5
pduOutletSwitchedConfigRebootDuration mandatory
The amount of time, in seconds, this outlet will remain
in powered off state before returning to power on state
during a reboot action.
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.5.2.1.6
.1.3.6.1.4.1.318.1.1.32.5.3 · 1 row entry · 6 columns
A table of PDU Switched Outlet properties
pduOutletSwitchedPropertiesEntry entry .1.3.6.1.4.1.318.1.1.32.5.3.1
An outlet properties entry containing objects for a particular outlet.
Indexes
pduUnitPropertiesIndex pduOutletSwitchedPropertiesIndex
Column Syntax OID
pduOutletSwitchedPropertiesIndex mandatory
The index of the PDU Switched Outlet properties table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.3.1.1
pduOutletSwitchedPropertiesNumber mandatory
The numeric Switched Outlet ID
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.3.1.2
pduOutletSwitchedPropertiesName mandatory
The user-defined switched outlet ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.5.3.1.3
pduOutletSwitchedPropertiesInputPhaseLayout mandatory
This OID describes the outlet phase connections
on the referenced bank as follows:
seqPhase1ToNeutral(1) indicates that outlets
attached to Switched Outlet are connected from Phase 1 to Neutral.
seqPhase2ToNeutral(2…
Enumeration
Enumerated Values:
1seqPhase1ToNeutral
2seqPhase2ToNeutral
3seqPhase3ToNeutral
4seqPhase1ToPhase2
5seqPhase2ToPhase3
6seqPhase3ToPhase1
.1.3.6.1.4.1.318.1.1.32.5.3.1.4
pduOutletSwitchedPropertiesCircuitBreaker mandatory
The numeric Circuit Breaker ID
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.3.1.5
pduOutletSwitchedPropertiesCurrentRating mandatory
The current rating of outlet in hundreths of ampere
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.3.1.6
.1.3.6.1.4.1.318.1.1.32.5.4 · 1 row entry · 4 columns
A table of PDU Switched Outlet status data
pduOutletSwitchedStatusEntry entry .1.3.6.1.4.1.318.1.1.32.5.4.1
Status data from the PDU Switched Outlet being queried
Indexes
pduUnitStatusIndex pduOutletSwitchedStatusIndex
Column Syntax OID
pduOutletSwitchedStatusIndex mandatory
The index of the PDU Switched Outlet status table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.4.1.1
pduOutletSwitchedStatusNumber mandatory
The numeric Switched Outlet ID
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.4.1.2
pduOutletSwitchedStatusName mandatory
The user-defined switched outlet ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.5.4.1.3
pduOutletSwitchedStatusState mandatory
Indicates the present switch state of the
PDU switched outlet being queried
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.318.1.1.32.5.4.1.4
.1.3.6.1.4.1.318.1.1.32.5.5 · 1 row entry · 4 columns
A table of PDU Switched Outlet status data
pduOutletSwitchedControlEntry entry .1.3.6.1.4.1.318.1.1.32.5.5.1
Status data from the PDU Switched Outlet
being queried
Indexes
pduUnitConfigIndex pduOutletSwitchedControlIndex
Column Syntax OID
pduOutletSwitchedControlIndex mandatory
The index to the PDU switched outlet
control data table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.5.1.1
pduOutletSwitchedControlNumber mandatory
The numeric Switched Outlet ID
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.5.1.2
pduOutletSwitchedControlName mandatory
The user-defined switched outlet ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.5.5.1.3
pduOutletSwitchedControlCommand mandatory
Getting this variable will return the outlet state.
If the outlet is on, the immediateOn (2)
value will be returned. If the outlet is off,
the immediateOff (1) value will be returned.
If the state of the outlet canno…
Enumerationr/w
Enumerated Values:
1immediateOff
2immediateOn
3delayedOff
4delayedOn
5immediateReboot
6delayedReboot
7outletUnknown
.1.3.6.1.4.1.318.1.1.32.5.5.1.4
.1.3.6.1.4.1.318.1.1.32.5.7 · 1 row entry · 9 columns
A table of PDU Metered Outlet configuration data
pduOutletMeteredConfigEntry entry .1.3.6.1.4.1.318.1.1.32.5.7.1
An outlet configuration entry containing objects for a particular outlet.
Indexes
pduUnitConfigIndex pduOutletMeteredConfigIndex
Column Syntax OID
pduOutletMeteredConfigIndex mandatory
The index of the PDU Metered Outlet
configuration table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.7.1.1
pduOutletMeteredName mandatory
The user-defined name for the Metered Outlet
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.5.7.1.2
pduOutletMeteredConfigLowerCriticalThreshold mandatory
User-defined lower critical outlet active power alarm threshold in Watts(W).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.5.7.1.3
pduOutletMeteredConfigLowerWarningThreshold mandatory
User-defined lower non-critical (warning) outlet active power alarm threshold in Watts(W).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.5.7.1.4
pduOutletMeteredConfigUpperCriticalThreshold mandatory
User-defined upper critical outlet active power alarm threshold in Watts(W).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.5.7.1.5
pduOutletMeteredConfigUpperWarningThreshold mandatory
User-defined upper non-critical (warning) outlet active power alarm threshold in Watts(W).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.5.7.1.6
pduOutletMeteredConfigAlarmResetThreshold mandatory
The hysteresis used for deassertions in Watts(W).
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.5.7.1.7
pduOutletMeteredConfigAlarmStateChangeDelay mandatory
The delay measured in samples before a state
is asserted. If the value is zero, then the state
is asserted as soon as it is detected; if it is
non-zero, say n, then the assertion condition must
exist for n+1 consecu…
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.5.7.1.8
pduOutletMeteredConfigEnabledThresholds mandatory
A bit string indicating which alarm
thresholds are enabled.
Bitsr/w
Enumerated Values:
0lowerCritical
1lowerWarning
2upperWarning
3upperCritical
.1.3.6.1.4.1.318.1.1.32.5.7.1.9
.1.3.6.1.4.1.318.1.1.32.5.8 · 1 row entry · 7 columns
A table of PDU Metered Outlet properties
pduOutletMeteredPropertiesEntry entry .1.3.6.1.4.1.318.1.1.32.5.8.1
Configuration data from the PDU Metered
Outlet being queried
Indexes
pduUnitPropertiesIndex pduOutletMeteredPropertiesIndex
Column Syntax OID
pduOutletMeteredPropertiesIndex mandatory
The index of the PDU Metered Outlet
properties table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.8.1.1
pduOutletMeteredPropertiesNumber mandatory
The numeric Metered Outlet ID
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.8.1.2
pduOutletMeteredPropertiesName mandatory
The user-defined Metered outlet ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.5.8.1.3
pduOutletMeteredPropertiesInputPhaseLayout mandatory
This OID describes the outlet phase connections
on the referenced bank as follows:
seqPhase1ToNeutral(1) indicates that outlets attached
to Metered Outlet are connected from Phase 1 to Neutral.
seqPhase2ToNeutral(2)…
Enumeration
Enumerated Values:
1seqPhase1ToNeutral
2seqPhase2ToNeutral
3seqPhase3ToNeutral
4seqPhase1ToPhase2
5seqPhase2ToPhase3
6seqPhase3ToPhase1
.1.3.6.1.4.1.318.1.1.32.5.8.1.4
pduOutletMeteredPropertiesCircuitBreaker mandatory
The numeric Circuit Breaker ID
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.8.1.5
pduOutletMeteredPropertiesPowerRating mandatory
Maximum power rating of the PDU metered outlet
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.5.8.1.6
pduOutletMeteredPropertiesCurrentRating mandatory
Metered outlet current rating in hundreths of ampere
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.5.8.1.7
.1.3.6.1.4.1.318.1.1.32.5.9 · 1 row entry · 11 columns
A table of PDU Metered Outlet status data
pduOutletMeteredStatusEntry entry .1.3.6.1.4.1.318.1.1.32.5.9.1
Status data from the PDU Metered Outlet being queried
Indexes
pduUnitStatusIndex pduOutletMeteredStatusIndex
Column Syntax OID
pduOutletMeteredStatusIndex mandatory
The index of the PDU Metered Outlet status table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.9.1.1
pduOutletMeteredStatusNumber mandatory
The numeric Metered Outlet ID
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.5.9.1.2
pduOutletMeteredStatusName mandatory
The user-defined Metered outlet ID string
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.5.9.1.3
pduOutletMeteredStatusLoadState mandatory
Returns the present load status of the PDU metered outlet being queried.
Enumeration
Enumerated Values:
1upperCritical
2upperWarning
3lowerWarning
4lowerCritical
5normal
.1.3.6.1.4.1.318.1.1.32.5.9.1.4
pduOutletMeteredStatusCurrent mandatory
Returns the current draw, in hundredths of Amps(A), of the load on the PDU
outlet being queried.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.5.9.1.5
pduOutletMeteredStatusActivePower mandatory
Returns the power draw, in Watts(W), of the load
on the PDU outlet being queried.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.5.9.1.6
pduOutletMeteredStatusPowerFactor mandatory
Returns the ratio of active to apparent power
of the PDU Outlet being queried
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.5.9.1.7
pduOutletMeteredStatusPeakPower mandatory
Returns peak power consumption, in Watts(W),
of the Rack PDU outlet being queried.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.5.9.1.8
pduOutletMeteredStatusPeakPowerTimeStamp mandatory
Indicates the date and time that this metered
outlet's peak power consumption occurred
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.5.9.1.9
pduOutletMeteredStatusPeakPowerStartTime mandatory
Indicates the start date and time that this metered
outlet began recording peak power observations
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.5.9.1.10
pduOutletMeteredStatusResettableEnergy mandatory
A user resettable energy meter measuring outlet load energy
consumption in tenths of Kilowatt-Hours(kWh).
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.5.9.1.11
.1.3.6.1.4.1.318.1.1.32.6.2 · 1 row entry · 8 columns
A table of PDU ExternalSensorNamePlate data
pduExternalSensorNamePlateEntry entry .1.3.6.1.4.1.318.1.1.32.6.2.1
External Sensor Name Plate data from the external
sensor being queried. The number of entries equals
the value of pduExternalSensorNamePlateTableSize.
Indexes
pduNamePlateIndex pduExternalSensorNamePlateIndex
Column Syntax OID
pduExternalSensorNamePlateIndex mandatory
The index of the PDU External Sensor status table entry
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.318.1.1.32.6.2.1.1
pduExternalSensorNamePlateName mandatory
A user-defined string identifying the external sensor
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.6.2.1.2
pduExternalSensorNamePlateDescription mandatory
A user-defined description of the external sensor
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.6.2.1.3
pduExternalSensorNamePlateLocation mandatory
A user-defined string identifying the location of the PDU
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.6.2.1.4
pduExternalSensorNamePlateSerialNumber mandatory
The serial number of the external sensor being queried
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.6.2.1.5
pduExternalSensorNamePlateType mandatory
The type of external sensor.
Enumeration
Enumerated Values:
1temperature
2humidity
3doorSwitch
4dryContact
5spotFluid
6ropeFluid
7smoke
8beacon
9airVelocity
17modbusAdapter
18hidAdapter
.1.3.6.1.4.1.318.1.1.32.6.2.1.6
pduExternalSensorNamePlateUnits mandatory
The base units the external sensor is measured in.
This parameter does not apply to onOff, trip, vibration,
waterDetection, smokeDetection sensors.
Enumeration
Enumerated Values:
0logic
1degreeC
2degreeF
3percent
4mps
.1.3.6.1.4.1.318.1.1.32.6.2.1.7
pduExternalSensorNamePlateIdentifier mandatory
Unique identifier of the external sensor.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.6.2.1.8
.1.3.6.1.4.1.318.1.1.32.6.3 · 1 row entry · 7 columns
A table of PDU External Sensor configuration data
pduExternalSensorConfigEntry entry .1.3.6.1.4.1.318.1.1.32.6.3.1
Configuration data from the PDU External
Sensor being queried
Indexes
pduUnitConfigIndex pduExternalSensorConfigIndex
Column Syntax OID
pduExternalSensorConfigIndex mandatory
The index of the PDU External Sensor
configuration table entry
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.318.1.1.32.6.3.1.1
pduExternalSensorConfigLowerCriticalThreshold mandatory
User-defined lower critical alarm threshold in pduExternalSensorNamePlateUnits.
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.6.3.1.2
pduExternalSensorConfigLowerWarningThreshold mandatory
User-defined lower non-critical (warning) alarm threshold in pduExternalSensorNamePlateUnits.
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.6.3.1.3
pduExternalSensorConfigUpperCriticalThreshold mandatory
User-defined upper critical alarm threshold in pduExternalSensorNamePlateUnits.
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.6.3.1.4
pduExternalSensorConfigUpperWarningThreshold mandatory
User-defined upper non-critical (warning) alarm threshold in pduExternalSensorNamePlateUnits.
Unsigned32r/w
Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32
.1.3.6.1.4.1.318.1.1.32.6.3.1.5
pduExternalSensorConfigEnabledThresholds mandatory
A bit string indicating which alarm
thresholds are enabled.
Bitsr/w
Enumerated Values:
0lowerCritical
1lowerWarning
2upperWarning
3upperCritical
4binarySensorAlarm
.1.3.6.1.4.1.318.1.1.32.6.3.1.6
pduExternalSensorConfigAlarmState mandatory
User defined alarm state of external sensor
Enumerationr/w
Enumerated Values:
0off
1on
.1.3.6.1.4.1.318.1.1.32.6.3.1.7
.1.3.6.1.4.1.318.1.1.32.6.4 · 1 row entry · 7 columns
A table of PDU External Sensor status data
pduExternalSensorStatusEntry entry .1.3.6.1.4.1.318.1.1.32.6.4.1
Status data from the PDU External Sensor
being queried
Indexes
pduUnitStatusIndex pduExternalSensorStatusIndex
Column Syntax OID
pduExternalSensorStatusIndex mandatory
The index of the PDU External Sensor status table entry
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.318.1.1.32.6.4.1.1
pduExternalSensorStatusName mandatory
The user-defined name for the External Sensor
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.6.4.1.2
pduExternalSensorStatusCommStatus mandatory
The communications status of the sensor
Enumeration
Enumerated Values:
1notInstalled
2commsOk
3commsLost
.1.3.6.1.4.1.318.1.1.32.6.4.1.3
pduExternalSensorStatusState mandatory
This OID reports the current state of the sensor.
A notPresent (0) response indicates that no sensor is attached.
An alarmed (1) response indicates that the sensor is present
and its measured reading indicates alarmed…
Enumeration
Enumerated Values:
0notPresent
1alarmed
2normal
3belowLowerCritical
4belowLowerWarning
5aboveUpperWarning
6aboveUpperCritical
.1.3.6.1.4.1.318.1.1.32.6.4.1.4
pduExternalSensorStatusValue mandatory
Sensor reading in pduExternalSensorConfigUnits value.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.6.4.1.5
pduExternalSensorStatusTimeStamp mandatory
The sensor reading timestamp.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.6.4.1.6
pduExternalSensorStatusHighPrecisionValue mandatory
Temperature sensor reading in tenths of pduExternalSensorConfigUnits value.
This OID is applied to temperature sensor only
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.6.4.1.7
.1.3.6.1.4.1.318.1.1.32.7.2 · 1 row entry · 5 columns
A table of Smart Cabinet information
pduUnitSmartCabinetEntry entry .1.3.6.1.4.1.318.1.1.32.7.2.1
Information of Smart Cabinet
Indexes
pduUnitSmartCabinetIndex
Column Syntax OID
pduUnitSmartCabinetIndex mandatory
The index of the PDU Smart Cabinet table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.7.2.1.1
pduUnitSmartCabinetCardUserName mandatory
User name of ID card
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.7.2.1.2
pduUnitSmartCabinetCardID mandatory
Card ID.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.7.2.1.3
pduUnitSmartCabinetTimestamp mandatory
Indicates the date and time of information update
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.7.2.1.4
pduUnitSmartCabinetDoor mandatory
Aisle of Smart Cabinet.
Enumeration
Enumerated Values:
1hotAisle
2coldAisle
.1.3.6.1.4.1.318.1.1.32.7.2.1.5
.1.3.6.1.4.1.318.1.1.32.7.4 · 1 row entry · 5 columns
A table of Smart Cabinet aisle state control
pduUnitSmartCabinetLockStateEntry entry .1.3.6.1.4.1.318.1.1.32.7.4.1
Information of Smart Cabinet Lock State
Indexes
pduUnitSmartCabinetLockStateIndex
Column Syntax OID
pduUnitSmartCabinetLockStateIndex mandatory
The index of the PDU Smart Cabinet table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.7.4.1.1
pduUnitSmartCabinetColdAisleLockState mandatory
Smart Cabinet ColdAisle lock state
Enumerationr/w
Enumerated Values:
0unlock
1lock
2notPresent
.1.3.6.1.4.1.318.1.1.32.7.4.1.2
pduUnitSmartCabinetHotAisleLockState mandatory
Smart Cabinet HotAisle lock state
Enumerationr/w
Enumerated Values:
0unlock
1lock
2notPresent
.1.3.6.1.4.1.318.1.1.32.7.4.1.3
pduUnitSmartCabinetColdAisleLockLabel mandatory
Label of cold aisle smartcabinet
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.7.4.1.4
pduUnitSmartCabinetHotAisleLockLabel mandatory
Label of hot aisle smartcabinet
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.7.4.1.5

trapsInfoTable

table mandatory
.1.3.6.1.4.1.318.1.1.32.8.1.1 · 1 row entry · 7 columns
A list of Trap Information entries. The number of
entries are given by the value of pduUnitTableSize.
trapsInfoEntry entry .1.3.6.1.4.1.318.1.1.32.8.1.1.1
An entry containing objects used in traps
Indexes
trapsInfoIndex
Column Syntax OID
trapsInfoIndex mandatory
The index of the traps table entry
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.1
userName mandatory
The user currently logged in.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.2
userUpdated mandatory
The user added, deleted, or modified.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.3
firmwareVersion mandatory
The version of Firmware.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.4
roleUpdated mandatory
The role added, deleted, or modified.
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.5
smtpRecipients mandatory
Comma separated list of SMTP recipients
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.6
smtpServer mandatory
The IP address/host name of the SMTP server
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.7

pduEhandleTable

table mandatory
.1.3.6.1.4.1.318.1.1.32.9.1 · 1 row entry · 13 columns
A list of contact sensors.  The number of entries are
given by number of pdu and pduEhandleCount.
pduEhandleEntry entry .1.3.6.1.4.1.318.1.1.32.9.1.1
An entry for a contact sensor
Indexes
pduEhandleIndex
Column Syntax OID
pduEhandleIndex mandatory
The index of the PDU HID table entry
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.318.1.1.32.9.1.1.1
pduEhandleAisle mandatory
Aisle of HID handle.
Enumeration
Enumerated Values:
1hot
2cold
.1.3.6.1.4.1.318.1.1.32.9.1.1.2
pduEhandleHandleOperation mandatory
HID handle control opterations
Enumerationr/w
Enumerated Values:
1unlock
2lock
.1.3.6.1.4.1.318.1.1.32.9.1.1.3
pduEhandleFwVer mandatory
The firmware revision level of the HID
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.9.1.1.4
pduEhandleMechanicalLock mandatory
HID Mechanical opterations
Enumeration
Enumerated Values:
1unlock
2lock
.1.3.6.1.4.1.318.1.1.32.9.1.1.5
pduEhandleSerial mandatory
The Serial Number of the HID
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.9.1.1.6
pduEhandleHwVer mandatory
The hardware revision level of the HID
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.9.1.1.7
pduEhandleAutoLockTime mandatory
HID Electronic Latch Autolock Time in seconds, Value ranges (0-999)
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.9.1.1.8
pduEhandleDoorOpenTime mandatory
HID Door Open Time in seconds, Value ranges (0-999)
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.9.1.1.9
pduEhandleMaxDoorOpenTime mandatory
HID Max Door Open Time in seconds, Value ranges (0-32400),
critical alarm will be raised if door is left open past this time
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.9.1.1.10
pduEhandleUserPinLength mandatory
Rack Access User minimum PIN Length, value ranges(1-15)
Integer32r/w
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.318.1.1.32.9.1.1.11
pduEhandleUserPinMode mandatory
Rack Access User PIN mode setting
Enumerationr/w
Enumerated Values:
1visible
2hidden
.1.3.6.1.4.1.318.1.1.32.9.1.1.12
pduEhandleAisleControl mandatory
Rack Access Aisle Control setting,
when set to standalone each aisle will controlled seprately,
when set to combined opposite aisle can be controlled with authenticated control action on either aisle
Enumerationr/w
Enumerated Values:
1combined
2standalone
.1.3.6.1.4.1.318.1.1.32.9.1.1.13

pduEhandleControlTable

table mandatory
.1.3.6.1.4.1.318.1.1.32.9.2 · 1 row entry · 9 columns
A list of smartcard.  The number of entries are
given by number of pdu and pduEhandleCount.
pduEhandleControlEntry entry .1.3.6.1.4.1.318.1.1.32.9.2.1
The smart card table entry containing the usrname, cardid, cardaisle etc.
Indexes
pduEhandleControlIndex
Column Syntax OID
pduEhandleControlIndex mandatory
The index of the PDU smartcard table entry
Integer32
Constraints:
range: 1-200
.1.3.6.1.4.1.318.1.1.32.9.2.1.1
pduEhandleControlUserName mandatory
User name of smartcard
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.9.2.1.2
pduEhandleControlCardIdStr mandatory
smartcard ID.
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.9.2.1.3
pduEhandleControlTimestamp mandatory
Indicates the date and time of accessing
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.9.2.1.4
pduEhandleControlCardAisle mandatory
Aisle of authorized card
Enumerationr/w
Enumerated Values:
1hot
2cold
3both
.1.3.6.1.4.1.318.1.1.32.9.2.1.5
pduEhandleControlStartTime mandatory
Indicates the start date and time Rack access user is given access
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.9.2.1.6
pduEhandleControlExpireTime mandatory
Indicates the date and time when the access of user card will expire, To set expire time first set user as temporary user
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.9.2.1.7
pduEhandleControlTempUser mandatory
Indicates if the card user has temporary access
Enumerationr/w
Enumerated Values:
1no
2yes
.1.3.6.1.4.1.318.1.1.32.9.2.1.8
pduEhandleControlPin mandatory
Rack acess control entry keypad PIN
RFC1213-MIBDisplayStringr/w
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.318.1.1.32.9.2.1.9