CPDU-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
26
Rows
26
Columns
224
.1.3.6.1.4.1.318.1.1.32.1.2
·
1 row entry
·
16 columns
A table of PDU nameplate data
Nameplate data from the PDU being queried. The numbers of entries equals the value of pduNamePlateTableSize.
Indexes
pduNamePlateIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
pduNamePlateIndex
mandatory
The index of the PDU nameplate table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.1.2.1.1 |
||||||
|
pduNamePlateName
mandatory
A user-defined string identifying the PDU
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.1.2.1.2 |
||||||
|
pduNamePlateLocation
mandatory
A user-defined string identifying the location of PDU
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.1.2.1.3 |
||||||
|
pduNamePlateInetAddressType
mandatory
The type of address format
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.1.2.1.4 |
||||||
|
pduNamePlateIPAddress
mandatory
The current IP address. A value of 0.0.0.0 indicates an error or an unset option
|
INET-ADDRESS-MIBInetAddress Textual Convention: INET-ADDRESS-MIBInetAddress OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.318.1.1.32.1.2.1.5 |
||||||
|
pduNamePlateInetNetMask
mandatory
The current netmask. A value of 0.0.0.0 indiates an error or an unset option
|
INET-ADDRESS-MIBInetAddress Textual Convention: INET-ADDRESS-MIBInetAddress OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.318.1.1.32.1.2.1.6 |
||||||
|
pduNamePlateInetGateway
mandatory
The current gateway. A value of 0.0.0.0 indicates an error or an unset option
|
INET-ADDRESS-MIBInetAddress Textual Convention: INET-ADDRESS-MIBInetAddress OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.318.1.1.32.1.2.1.7 |
||||||
|
pduNamePlateMACAddress
mandatory
The assigned MAC address for the PDU
|
SNMPv2-TCMacAddress Textual Convention: SNMPv2-TCMacAddress OctetStringType Constraints: range: 6 |
.1.3.6.1.4.1.318.1.1.32.1.2.1.8 |
||||||
|
pduNamePlateUTCTimeOffset
mandatory
The difference in hours and minutes from Coordinated Universal
Time(UTC) for the time used in a particular time zone |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.1.2.1.9 |
||||||
|
pduNamePlateModelNumber
mandatory
The PDU model number
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.1.2.1.10 |
||||||
|
pduNamePlatePartNumber
mandatory
The PDU part number
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.1.2.1.11 |
||||||
|
pduNamePlateSerialNumber
mandatory
The PDU serial number
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.1.2.1.12 |
||||||
|
pduNamePlateDateofManufacture
mandatory
The date the PDU was manufactured in mm/dd/yyyy format
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.1.2.1.13 |
||||||
|
pduNamePlateFirmwareVersion
mandatory
The PDU firmware version
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.1.2.1.14 |
||||||
|
pduNamePlateFirmwareVersionTimeStamp
mandatory
Timestamp of when the PDU firmware was last updated
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.1.2.1.15 |
||||||
|
pduNamePlateType
mandatory
The type of input
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.1.2.1.16 |
.1.3.6.1.4.1.318.1.1.32.2.2
·
1 row entry
·
20 columns
A table of PDU configuration data
Configuration data from the PDU being queried. The number of entries equals the value of pduUnitTableSize
Indexes
pduUnitConfigIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
pduUnitConfigIndex
mandatory
The index of the PDU Unit Config Entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.2.2.1.1 |
||||||||
|
pduUnitConfigName
mandatory
A user-defined string identifying the PDU
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.2.1.2 |
||||||||
|
pduUnitConfigLocation
mandatory
A user-defined string identifying the location of the PDU
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.2.1.3 |
||||||||
|
pduUnitConfigDisplayOrientation
mandatory
Indicates the intended physical orientation of the oLED display
displayNormal (1) indicates normal orientation. displayReverse (2) indicates upside down orientation NOTE: This OID is compatible only with the two displa… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.2.1.4 |
||||||||
|
pduUnitConfigOledDisplayControl
mandatory
Used to turn oled display On or Off
displayOff (1) to turn dispaly OFF. displayOn (2) to turn dispaly ON |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.2.1.5 |
||||||||
|
pduUnitConfigColdstartDelay
mandatory
The amount of time, specified in seconds, between when power
is provided to the PDU and when the PDU start providing basic master power to the outlets |
Unsigned32r/w Constraints: range: 0-3600 |
.1.3.6.1.4.1.318.1.1.32.2.2.1.6 |
||||||||
|
pduUnitConfigGlobalOutletStateOnStartup
mandatory
The outlet state on device startup; applies to all outlets
unless overridden at the outlet level |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.2.1.7 |
||||||||
|
pduUnitConfigLowerCriticalThreshold
mandatory
User-defined lower critical unit active power alarm threshold measured in Watts
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.2.2.1.8 |
||||||||
|
pduUnitConfigLowerWarningThreshold
mandatory
User-defined lower non-critical (warning) unit active power alarm threshold measured in Watts
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.2.2.1.9 |
||||||||
|
pduUnitConfigUpperCriticalThreshold
mandatory
User-defined upper critical unit active power alarm threshold measured in Watts
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.2.2.1.10 |
||||||||
|
pduUnitConfigUpperWarningThreshold
mandatory
User-defined upper non-critical (warning) unit active power alarm threshold measured in Watts
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.2.2.1.11 |
||||||||
|
pduUnitConfigAlarmResetThreshold
mandatory
The hysteresis used for deassertions in Watts
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.2.2.1.12 |
||||||||
|
pduUnitConfigAlarmStateChangeDelay
mandatory
The delay measured in samples before a state is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecutive…
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.2.2.1.13 |
||||||||
|
pduUnitConfigEnabledThresholds
mandatory
A bit string indicating which alarm thresholds are enabled
|
Bitsr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.2.1.14 |
||||||||
|
pduUnitConfigPeakPowerReset
mandatory
Setting this OID to reset (2) will cause the existing peak power value
to be replaced by the current load power value. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.2.1.15 |
||||||||
|
pduUnitConfigEnergyReset
mandatory
Setting this OID to reset (2) will cause the device energy meter value
to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.2.1.16 |
||||||||
|
pduUnitConfigOutletPeakPowerReset
mandatory
Setting this OID to reset (2) will cause the outlet peak power meter value
to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.2.1.17 |
||||||||
|
pduUnitConfigOutletEnergyReset
mandatory
Setting this OID to reset (2) will cause the outlet energy meter value
to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.2.1.18 |
||||||||
|
pduUnitConfigSsh
mandatory
Setting this OID to off(0) will disable the SSH connection. Setting this OID to on(1) will enable the SSH connection.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.2.1.19 |
||||||||
|
pduUnitConfigResetNetworkManagementCard
mandatory
Getting this OID will return noOperation(0). Setting this OID to reset(1) will reset NMC.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.2.1.20 |
.1.3.6.1.4.1.318.1.1.32.2.3
·
1 row entry
·
16 columns
A table of PDU properties
A unit properties entry containing objects for a particular unit.
Indexes
pduUnitPropertiesIndex
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduUnitPropertiesIndex
mandatory
The index of the PDU properties table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.2.3.1.1 |
||||||||||||||||||
|
pduUnitPropertiesName
mandatory
A user-defined string identifying the PDU
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.3.1.2 |
||||||||||||||||||
|
pduUnitPropertiesOutletCount
mandatory
The total number of outlets on the PDU
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.2.3.1.3 |
||||||||||||||||||
|
pduUnitPropertiesSwitchedOutletCount
mandatory
The total number of switched outlets on the PDU
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.2.3.1.4 |
||||||||||||||||||
|
pduUnitPropertiesMeteredOutletCount
mandatory
The total number of metered outlets on the PDU
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.2.3.1.5 |
||||||||||||||||||
|
pduUnitPropertiesInputPhaseCount
mandatory
The total number of phases on the PDU
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.2.3.1.6 |
||||||||||||||||||
|
pduUnitPropertiesCircuitBreakerCount
mandatory
The total number of circuit breaker on the PDU
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.32.2.3.1.7 |
||||||||||||||||||
|
pduUnitPropertiesMaxExternalSensorCount
mandatory
The maximum number of external sensors that can be connected to the PDU
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.32.2.3.1.8 |
||||||||||||||||||
|
pduUnitPropertiesConnExternalSensorCount
mandatory
The current number of external sensors connected to the PDU
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.32.2.3.1.9 |
||||||||||||||||||
|
pduUnitPropertiesRatedVoltage
mandatory
The PDU voltage rating in Volts
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.3.1.10 |
||||||||||||||||||
|
pduUnitPropertiesRatedMaxCurrent
mandatory
The PDU current rating in Amps
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.3.1.11 |
||||||||||||||||||
|
pduUnitPropertiesRatedFrequency
mandatory
The PDU frequency rating in Hz
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.3.1.12 |
||||||||||||||||||
|
pduUnitPropertiesRatedPower
mandatory
The PDU VA (VoltAmps) rating.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.3.1.13 |
||||||||||||||||||
|
pduUnitPropertiesOrientation
mandatory
The PDU orientation
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.3.1.14 |
||||||||||||||||||
|
pduUnitPropertiesOutletLayout
mandatory
The outlet layout for the PDU. Getting this OID will return outlet layout for the device.
seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... seqPhaseToPhase(2) indicates outlet la… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.3.1.15 |
||||||||||||||||||
|
pduUnitPropertiesCascadeMemberType
mandatory
The cascading member type
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.3.1.16 |
.1.3.6.1.4.1.318.1.1.32.2.4
·
1 row entry
·
12 columns
A table of PDU status information
Status information from the PDU being queried
Indexes
pduUnitStatusIndex
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduUnitStatusIndex
mandatory
The index of the PDU status table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.2.4.1.1 |
||||||||||
|
pduUnitStatusName
mandatory
A user-defined string identifying the PDU
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.4.1.2 |
||||||||||
|
pduUnitStatusLoadState
mandatory
Returns the present load status of the PDU based on Active Power.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.4.1.3 |
||||||||||
|
pduUnitStatusActivePower
mandatory
Returns power consumption, in Watts(W),
of the PDU being queried. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.2.4.1.4 |
||||||||||
|
pduUnitStatusApparentPower
mandatory
Returns power consumption, in Volt-Amps(VA)
of the PDU load being queried. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.2.4.1.5 |
||||||||||
|
pduUnitStatusPeakPower
mandatory
Returns peak power consumption, in Watts(W),
of the PDU being queried. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.2.4.1.6 |
||||||||||
|
pduUnitStatusPeakPowerTimestamp
mandatory
Indicates the date and time that peak power consumption occurred
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.4.1.7 |
||||||||||
|
pduUnitStatusPeakPowerStartTime
mandatory
Indicates the date and time of the last device peak power reset
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.4.1.8 |
||||||||||
|
pduUnitStatusEnergy
mandatory
Returns total energy consumed, in tenths of Kilowatt-Hours(kWh), of the PDU over its lifetime.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.2.4.1.9 |
||||||||||
|
pduUnitStatusResettableEnergy
mandatory
A user resettable energy meter measuring PDU energy consumption
in tenths of kilowatt-hours(kWh). |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.2.4.1.10 |
||||||||||
|
pduUnitStatusEnergyStartTime
mandatory
Indicates the date and time of the last device energy meter reset
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.4.1.11 |
||||||||||
|
pduUnitStatusOutletsEnergyStartTime
mandatory
Indicates the date and time of the last outlets energy meter reset
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.2.4.1.12 |
.1.3.6.1.4.1.318.1.1.32.2.5
·
1 row entry
·
4 columns
Aggregate Object with number of entries equal to number of PDUs and Power share
The Power share entry containing the avaliable, input, output etc.
Indexes
pduUnitPsIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
pduUnitPsIndex
mandatory
The index of the PDU Power share table entry
|
Integer32 Constraints: range: 1-4 |
.1.3.6.1.4.1.318.1.1.32.2.5.1.1 |
||||
|
pduUnitPsSupportUpstreamStatus
mandatory
Power share support status on upstream PDU
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.5.1.2 |
||||
|
pduUnitPsSupportDownstreamStatus
mandatory
Power share support status on downstream PDU
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.5.1.3 |
||||
|
pduUnitPsOptMode
mandatory
Operating power status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.2.5.1.4 |
.1.3.6.1.4.1.318.1.1.32.3.2
·
1 row entry
·
17 columns
A table of PDU Input Phase configuration data
An input phase entry containing objects for a particular input phase.
Indexes
pduUnitConfigIndex pduInputPhaseConfigIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
pduInputPhaseConfigIndex
mandatory
The index of the PDU Input Phase configuration table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.1 |
||||||||
|
pduInputPhaseConfigCount
mandatory
The total number of Input Phases
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.2 |
||||||||
|
pduInputPhaseConfigOverloadRestriction
mandatory
This OID controls the behavior of a Switched PDU Input Phase when an
overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allow th… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.3.2.1.3 |
||||||||
|
pduInputPhaseConfigCurrentLowerCriticalThreshold
mandatory
User-defined lower critical input phase current alarm threshold in hundredths of Amps(A).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.4 |
||||||||
|
pduInputPhaseConfigCurrentLowerWarningThreshold
mandatory
User-defined lower non-critical (warning) input phase current alarm threshold in hundredths of Amps(A).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.5 |
||||||||
|
pduInputPhaseConfigCurrentUpperCriticalThreshold
mandatory
User-defined upper critical input phase current alarm threshold in hundredths of Amps(A).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.6 |
||||||||
|
pduInputPhaseConfigCurrentUpperWarningThreshold
mandatory
User-defined upper non-critical (warning) input phase current alarm threshold in hundredths of Amps(A).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.7 |
||||||||
|
pduInputPhaseConfigVoltageLowerCriticalThreshold
mandatory
User-defined lower critical input phase voltage alarm threshold in Volts(V).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.8 |
||||||||
|
pduInputPhaseConfigVoltageLowerWarningThreshold
mandatory
User-defined lower non-critical (warning) input phase voltage alarm threshold in Volts(V).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.9 |
||||||||
|
pduInputPhaseConfigVoltageUpperCriticalThreshold
mandatory
User-defined upper critical input phase voltage alarm threshold in Volts(V).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.10 |
||||||||
|
pduInputPhaseConfigVoltageUpperWarningThreshold
mandatory
User-defined upper non-critical (warning) input phase voltage alarm threshold in Volts(V).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.11 |
||||||||
|
pduInputPhaseConfigCurrentAlarmResetThreshold
mandatory
The hysteresis used for current alarm deassertions in hundredths of Amps(A).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.12 |
||||||||
|
pduInputPhaseConfigCurrentAlarmStateChangeDelay
mandatory
The delay measured in samples before a current state is asserted. If the
value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 … |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.13 |
||||||||
|
pduInputPhaseConfigCurrentEnabledThresholds
mandatory
A bit string indicating which current alarm thresholds are enabled.
|
Bitsr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.3.2.1.14 |
||||||||
|
pduInputPhaseConfigVoltageAlarmResetThreshold
mandatory
The hysteresis used for voltage alarm deassertions in Volts(V).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.15 |
||||||||
|
pduInputPhaseConfigVoltageAlarmStateChangeDelay
mandatory
The delay measured in samples before a voltage state is asserted. If the
value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 … |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.3.2.1.16 |
||||||||
|
pduInputPhaseConfigVoltageEnabledThresholds
mandatory
A bit string indicating which voltage alarm thresholds are enabled.
|
Bitsr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.3.2.1.17 |
.1.3.6.1.4.1.318.1.1.32.3.3
·
1 row entry
·
2 columns
A table of PDU Input Phase properties
An input phase properties entry containing objects for a particular input phase.
Indexes
pduUnitPropertiesIndex pduInputPhasePropertiesIndex
| Column | Syntax | OID |
|---|---|---|
|
pduInputPhasePropertiesIndex
mandatory
The index of the PDU Input Phase status entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.3.3.1.1 |
|
pduInputPhasePropertiesCount
mandatory
The numeric Input Phase ID
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.3.3.1.2 |
.1.3.6.1.4.1.318.1.1.32.3.4
·
1 row entry
·
9 columns
A table of PDU Input Phase status data
An input phase status entry containing objects for a particular input phase.
Indexes
pduUnitStatusIndex pduInputPhaseStatusIndex
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduInputPhaseStatusIndex
mandatory
The index of the PDU Input Phase status entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.3.4.1.1 |
||||||||||
|
pduInputPhaseStatusCount
mandatory
The numeric Input Phase ID
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.3.4.1.2 |
||||||||||
|
pduInputPhaseStatusCurrentState
mandatory
Indicates the present current status of the PDU Phase in case of Y connection or PDU Line in case of Delta conneciton.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.3.4.1.3 |
||||||||||
|
pduInputPhaseStatusVoltageState
mandatory
Indicates the present voltage status of the PDU Input Phase being queried
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.3.4.1.4 |
||||||||||
|
pduInputPhaseStatusCurrent
mandatory
Returns the current draw, in hundredths of Amps(A)
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.3.4.1.5 |
||||||||||
|
pduInputPhaseStatusVoltage
mandatory
Returns the voltage, in Volts(V)
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.3.4.1.6 |
||||||||||
|
pduInputPhaseStatusActivePower
mandatory
Returns power consumption, in Watts(W)
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.3.4.1.7 |
||||||||||
|
pduInputPhaseStatusApparentPower
mandatory
Returns power consumption, in Volt-Amps(VA)
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.3.4.1.8 |
||||||||||
|
pduInputPhaseStatusPowerFactor
mandatory
Returns the ratio of active to apparent power of the PDU.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.3.4.1.9 |
.1.3.6.1.4.1.318.1.1.32.4.2
·
1 row entry
·
11 columns
A table of PDU Circuit Breaker configuration data
A circuit breaker configuration entry containing objects for a particular circuit breaker.
Indexes
pduUnitConfigIndex pduCircuitBreakerConfigIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
pduCircuitBreakerConfigIndex
mandatory
The index of the PDU Circuit Breaker configuration table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.4.2.1.1 |
||||||||
|
pduCircuitBreakerConfigCount
mandatory
The number of circuit breakers on the PDU
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.32.4.2.1.2 |
||||||||
|
pduCircuitBreakerName
mandatory
The label of the circuit breaker
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.4.2.1.3 |
||||||||
|
pduCircuitBreakerConfigOverloadRestriction
mandatory
This OID controls the behavior of a Switched PDU Circuit
Breaker when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always allo… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.4.2.1.4 |
||||||||
|
pduCircuitBreakerConfigLowerCriticalThreshold
mandatory
User-defined lower critical circuit breaker current alarm threshold in hundredths of Amps(A).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.4.2.1.5 |
||||||||
|
pduCircuitBreakerConfigLowerWarningThreshold
mandatory
User-defined lower non-critical (warning) circuit breaker current alarm threshold in hundredths of Amps(A).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.4.2.1.6 |
||||||||
|
pduCircuitBreakerConfigUpperCriticalThreshold
mandatory
User-defined upper critical circuit breaker current alarm threshold in hundredths of Amps(A).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.4.2.1.7 |
||||||||
|
pduCircuitBreakerConfigUpperWarningThreshold
mandatory
User-defined upper non-critical (warning) circuit breaker current alarm threshold in hundredths of Amps(A).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.4.2.1.8 |
||||||||
|
pduCircuitBreakerConfigAlarmResetThreshold
mandatory
The hysteresis used for deassertions in hundredths of Amps(A).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.4.2.1.9 |
||||||||
|
pduCircuitBreakerConfigAlarmStateChangeDelay
mandatory
The delay measured in samples before a state is asserted.
If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecut… |
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.4.2.1.10 |
||||||||
|
pduCircuitBreakerConfigEnabledThresholds
mandatory
A bit string indicating which alarm thresholds are enabled.
|
Bitsr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.4.2.1.11 |
.1.3.6.1.4.1.318.1.1.32.4.3
·
1 row entry
·
4 columns
A table of PDU circuit breaker properties
A circuit breaker properties entry containing objects for a particular circuit breaker.
Indexes
pduUnitPropertiesIndex pduCircuitBreakerPropertiesIndex
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduCircuitBreakerPropertiesIndex
mandatory
The index of the PDU Circuit Breaker properties table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.4.3.1.1 |
||||||||||||
|
pduCircuitBreakerPropertiesCount
mandatory
The number of Circuit Breakers
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.32.4.3.1.2 |
||||||||||||
|
pduCircuitBreakerPropertiesInputLayout
mandatory
This OID describes the outlet phase connections on
the referenced bank as follows: seqPhase1ToNeutral(1) indicates that outlets attached to circuit breaker are connected from Phase 1 to Neutral. seqPhase2ToNeutral(2… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.4.3.1.3 |
||||||||||||
|
pduCircuitBreakerPropertiesCurrentRating
mandatory
The number of Circuit Breakers
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.32.4.3.1.4 |
.1.3.6.1.4.1.318.1.1.32.4.4
·
1 row entry
·
5 columns
A table of PDU circuit breaker status data
A circuit breaker status entry containing objects for a particular circuit breaker.
Indexes
pduUnitStatusIndex pduCircuitBreakerStatusIndex
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduCircuitBreakerStatusIndex
mandatory
The index of the PDU Circuit Breaker status table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.4.4.1.1 |
||||||||||||
|
pduCircuitBreakerStatusCount
mandatory
The number of Circuit Breakers
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.32.4.4.1.2 |
||||||||||||
|
pduCircuitBreakerLabel
mandatory
The label on the PDU identifying the circuit breaker
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.4.4.1.3 |
||||||||||||
|
pduCircuitBreakerStatusLoadState
mandatory
Indicates the present load status of the PDU Circuit
Breaker being queried |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.4.4.1.4 |
||||||||||||
|
pduCircuitBreakerStatusCurrent
mandatory
Returns the current draw, in hundredths of Amps(A), of the load on
the PDU Circuit Breaker being queried. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.4.4.1.5 |
.1.3.6.1.4.1.318.1.1.32.5.2
·
1 row entry
·
6 columns
A table of PDU Switched Outlet configuration data
An outlet configuration entry containing objects for a particular outlet.
Indexes
pduUnitConfigIndex pduOutletSwitchedConfigIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
pduOutletSwitchedConfigIndex
mandatory
The index of the PDU Switched Outlet configuration table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.2.1.1 |
||||||
|
pduOutletSwitchedName
mandatory
The user-defined name for the Switched Outlet
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.5.2.1.2 |
||||||
|
pduOutletSwitchedStateOnStartup
mandatory
The outlet state on device startup; overrides
the global value pduUnitConfigGlobalOutletStateOnStartup. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.5.2.1.3 |
||||||
|
pduOutletSwitchedConfigPowerOnTime
mandatory
The amount of delay, in seconds, between when power is
provided to outlets the outlet and when this outlet starts providing power |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.5.2.1.4 |
||||||
|
pduOutletSwitchedConfigPowerOffTime
mandatory
The amount of time, in seconds, this outlet will delay
powering off |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.5.2.1.5 |
||||||
|
pduOutletSwitchedConfigRebootDuration
mandatory
The amount of time, in seconds, this outlet will remain
in powered off state before returning to power on state during a reboot action. |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.5.2.1.6 |
.1.3.6.1.4.1.318.1.1.32.5.3
·
1 row entry
·
6 columns
A table of PDU Switched Outlet properties
An outlet properties entry containing objects for a particular outlet.
Indexes
pduUnitPropertiesIndex pduOutletSwitchedPropertiesIndex
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduOutletSwitchedPropertiesIndex
mandatory
The index of the PDU Switched Outlet properties table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.3.1.1 |
||||||||||||
|
pduOutletSwitchedPropertiesNumber
mandatory
The numeric Switched Outlet ID
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.3.1.2 |
||||||||||||
|
pduOutletSwitchedPropertiesName
mandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.5.3.1.3 |
||||||||||||
|
pduOutletSwitchedPropertiesInputPhaseLayout
mandatory
This OID describes the outlet phase connections
on the referenced bank as follows: seqPhase1ToNeutral(1) indicates that outlets attached to Switched Outlet are connected from Phase 1 to Neutral. seqPhase2ToNeutral(2… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.5.3.1.4 |
||||||||||||
|
pduOutletSwitchedPropertiesCircuitBreaker
mandatory
The numeric Circuit Breaker ID
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.3.1.5 |
||||||||||||
|
pduOutletSwitchedPropertiesCurrentRating
mandatory
The current rating of outlet in hundreths of ampere
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.3.1.6 |
.1.3.6.1.4.1.318.1.1.32.5.4
·
1 row entry
·
4 columns
A table of PDU Switched Outlet status data
Status data from the PDU Switched Outlet being queried
Indexes
pduUnitStatusIndex pduOutletSwitchedStatusIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
pduOutletSwitchedStatusIndex
mandatory
The index of the PDU Switched Outlet status table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.4.1.1 |
||||
|
pduOutletSwitchedStatusNumber
mandatory
The numeric Switched Outlet ID
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.4.1.2 |
||||
|
pduOutletSwitchedStatusName
mandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.5.4.1.3 |
||||
|
pduOutletSwitchedStatusState
mandatory
Indicates the present switch state of the
PDU switched outlet being queried |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.5.4.1.4 |
.1.3.6.1.4.1.318.1.1.32.5.5
·
1 row entry
·
4 columns
A table of PDU Switched Outlet status data
Status data from the PDU Switched Outlet
being queried
being queried
Indexes
pduUnitConfigIndex pduOutletSwitchedControlIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduOutletSwitchedControlIndex
mandatory
The index to the PDU switched outlet
control data table entry |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.5.1.1 |
||||||||||||||
|
pduOutletSwitchedControlNumber
mandatory
The numeric Switched Outlet ID
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.5.1.2 |
||||||||||||||
|
pduOutletSwitchedControlName
mandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.5.5.1.3 |
||||||||||||||
|
pduOutletSwitchedControlCommand
mandatory
Getting this variable will return the outlet state.
If the outlet is on, the immediateOn (2) value will be returned. If the outlet is off, the immediateOff (1) value will be returned. If the state of the outlet canno… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.5.5.1.4 |
.1.3.6.1.4.1.318.1.1.32.5.7
·
1 row entry
·
9 columns
A table of PDU Metered Outlet configuration data
An outlet configuration entry containing objects for a particular outlet.
Indexes
pduUnitConfigIndex pduOutletMeteredConfigIndex
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
pduOutletMeteredConfigIndex
mandatory
The index of the PDU Metered Outlet
configuration table entry |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.7.1.1 |
||||||||
|
pduOutletMeteredName
mandatory
The user-defined name for the Metered Outlet
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.5.7.1.2 |
||||||||
|
pduOutletMeteredConfigLowerCriticalThreshold
mandatory
User-defined lower critical outlet active power alarm threshold in Watts(W).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.5.7.1.3 |
||||||||
|
pduOutletMeteredConfigLowerWarningThreshold
mandatory
User-defined lower non-critical (warning) outlet active power alarm threshold in Watts(W).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.5.7.1.4 |
||||||||
|
pduOutletMeteredConfigUpperCriticalThreshold
mandatory
User-defined upper critical outlet active power alarm threshold in Watts(W).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.5.7.1.5 |
||||||||
|
pduOutletMeteredConfigUpperWarningThreshold
mandatory
User-defined upper non-critical (warning) outlet active power alarm threshold in Watts(W).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.5.7.1.6 |
||||||||
|
pduOutletMeteredConfigAlarmResetThreshold
mandatory
The hysteresis used for deassertions in Watts(W).
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.5.7.1.7 |
||||||||
|
pduOutletMeteredConfigAlarmStateChangeDelay
mandatory
The delay measured in samples before a state
is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecu… |
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.5.7.1.8 |
||||||||
|
pduOutletMeteredConfigEnabledThresholds
mandatory
A bit string indicating which alarm
thresholds are enabled. |
Bitsr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.5.7.1.9 |
.1.3.6.1.4.1.318.1.1.32.5.8
·
1 row entry
·
7 columns
A table of PDU Metered Outlet properties
Configuration data from the PDU Metered
Outlet being queried
Outlet being queried
Indexes
pduUnitPropertiesIndex pduOutletMeteredPropertiesIndex
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduOutletMeteredPropertiesIndex
mandatory
The index of the PDU Metered Outlet
properties table entry |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.8.1.1 |
||||||||||||
|
pduOutletMeteredPropertiesNumber
mandatory
The numeric Metered Outlet ID
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.8.1.2 |
||||||||||||
|
pduOutletMeteredPropertiesName
mandatory
The user-defined Metered outlet ID string
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.5.8.1.3 |
||||||||||||
|
pduOutletMeteredPropertiesInputPhaseLayout
mandatory
This OID describes the outlet phase connections
on the referenced bank as follows: seqPhase1ToNeutral(1) indicates that outlets attached to Metered Outlet are connected from Phase 1 to Neutral. seqPhase2ToNeutral(2)… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.5.8.1.4 |
||||||||||||
|
pduOutletMeteredPropertiesCircuitBreaker
mandatory
The numeric Circuit Breaker ID
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.8.1.5 |
||||||||||||
|
pduOutletMeteredPropertiesPowerRating
mandatory
Maximum power rating of the PDU metered outlet
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.5.8.1.6 |
||||||||||||
|
pduOutletMeteredPropertiesCurrentRating
mandatory
Metered outlet current rating in hundreths of ampere
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.5.8.1.7 |
.1.3.6.1.4.1.318.1.1.32.5.9
·
1 row entry
·
11 columns
A table of PDU Metered Outlet status data
Status data from the PDU Metered Outlet being queried
Indexes
pduUnitStatusIndex pduOutletMeteredStatusIndex
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduOutletMeteredStatusIndex
mandatory
The index of the PDU Metered Outlet status table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.9.1.1 |
||||||||||
|
pduOutletMeteredStatusNumber
mandatory
The numeric Metered Outlet ID
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.5.9.1.2 |
||||||||||
|
pduOutletMeteredStatusName
mandatory
The user-defined Metered outlet ID string
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.5.9.1.3 |
||||||||||
|
pduOutletMeteredStatusLoadState
mandatory
Returns the present load status of the PDU metered outlet being queried.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.5.9.1.4 |
||||||||||
|
pduOutletMeteredStatusCurrent
mandatory
Returns the current draw, in hundredths of Amps(A), of the load on the PDU
outlet being queried. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.5.9.1.5 |
||||||||||
|
pduOutletMeteredStatusActivePower
mandatory
Returns the power draw, in Watts(W), of the load
on the PDU outlet being queried. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.5.9.1.6 |
||||||||||
|
pduOutletMeteredStatusPowerFactor
mandatory
Returns the ratio of active to apparent power
of the PDU Outlet being queried |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.5.9.1.7 |
||||||||||
|
pduOutletMeteredStatusPeakPower
mandatory
Returns peak power consumption, in Watts(W),
of the Rack PDU outlet being queried. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.5.9.1.8 |
||||||||||
|
pduOutletMeteredStatusPeakPowerTimeStamp
mandatory
Indicates the date and time that this metered
outlet's peak power consumption occurred |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.5.9.1.9 |
||||||||||
|
pduOutletMeteredStatusPeakPowerStartTime
mandatory
Indicates the start date and time that this metered
outlet began recording peak power observations |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.5.9.1.10 |
||||||||||
|
pduOutletMeteredStatusResettableEnergy
mandatory
A user resettable energy meter measuring outlet load energy
consumption in tenths of Kilowatt-Hours(kWh). |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.5.9.1.11 |
.1.3.6.1.4.1.318.1.1.32.6.2
·
1 row entry
·
8 columns
A table of PDU ExternalSensorNamePlate data
External Sensor Name Plate data from the external
sensor being queried. The number of entries equals
the value of pduExternalSensorNamePlateTableSize.
sensor being queried. The number of entries equals
the value of pduExternalSensorNamePlateTableSize.
Indexes
pduNamePlateIndex pduExternalSensorNamePlateIndex
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduExternalSensorNamePlateIndex
mandatory
The index of the PDU External Sensor status table entry
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.32.6.2.1.1 |
||||||||||||||||||||||
|
pduExternalSensorNamePlateName
mandatory
A user-defined string identifying the external sensor
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.6.2.1.2 |
||||||||||||||||||||||
|
pduExternalSensorNamePlateDescription
mandatory
A user-defined description of the external sensor
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.6.2.1.3 |
||||||||||||||||||||||
|
pduExternalSensorNamePlateLocation
mandatory
A user-defined string identifying the location of the PDU
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.6.2.1.4 |
||||||||||||||||||||||
|
pduExternalSensorNamePlateSerialNumber
mandatory
The serial number of the external sensor being queried
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.6.2.1.5 |
||||||||||||||||||||||
|
pduExternalSensorNamePlateType
mandatory
The type of external sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.6.2.1.6 |
||||||||||||||||||||||
|
pduExternalSensorNamePlateUnits
mandatory
The base units the external sensor is measured in.
This parameter does not apply to onOff, trip, vibration, waterDetection, smokeDetection sensors. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.6.2.1.7 |
||||||||||||||||||||||
|
pduExternalSensorNamePlateIdentifier
mandatory
Unique identifier of the external sensor.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.6.2.1.8 |
.1.3.6.1.4.1.318.1.1.32.6.3
·
1 row entry
·
7 columns
A table of PDU External Sensor configuration data
Configuration data from the PDU External
Sensor being queried
Sensor being queried
Indexes
pduUnitConfigIndex pduExternalSensorConfigIndex
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduExternalSensorConfigIndex
mandatory
The index of the PDU External Sensor
configuration table entry |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.32.6.3.1.1 |
||||||||||
|
pduExternalSensorConfigLowerCriticalThreshold
mandatory
User-defined lower critical alarm threshold in pduExternalSensorNamePlateUnits.
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.6.3.1.2 |
||||||||||
|
pduExternalSensorConfigLowerWarningThreshold
mandatory
User-defined lower non-critical (warning) alarm threshold in pduExternalSensorNamePlateUnits.
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.6.3.1.3 |
||||||||||
|
pduExternalSensorConfigUpperCriticalThreshold
mandatory
User-defined upper critical alarm threshold in pduExternalSensorNamePlateUnits.
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.6.3.1.4 |
||||||||||
|
pduExternalSensorConfigUpperWarningThreshold
mandatory
User-defined upper non-critical (warning) alarm threshold in pduExternalSensorNamePlateUnits.
|
Unsigned32r/w Textual Convention: CISCO-ATM-SWITCH-CUG-MIBUnsigned32 Unsigned32 |
.1.3.6.1.4.1.318.1.1.32.6.3.1.5 |
||||||||||
|
pduExternalSensorConfigEnabledThresholds
mandatory
A bit string indicating which alarm
thresholds are enabled. |
Bitsr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.6.3.1.6 |
||||||||||
|
pduExternalSensorConfigAlarmState
mandatory
User defined alarm state of external sensor
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.6.3.1.7 |
.1.3.6.1.4.1.318.1.1.32.6.4
·
1 row entry
·
7 columns
A table of PDU External Sensor status data
Status data from the PDU External Sensor
being queried
being queried
Indexes
pduUnitStatusIndex pduExternalSensorStatusIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pduExternalSensorStatusIndex
mandatory
The index of the PDU External Sensor status table entry
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.32.6.4.1.1 |
||||||||||||||
|
pduExternalSensorStatusName
mandatory
The user-defined name for the External Sensor
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.6.4.1.2 |
||||||||||||||
|
pduExternalSensorStatusCommStatus
mandatory
The communications status of the sensor
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.6.4.1.3 |
||||||||||||||
|
pduExternalSensorStatusState
mandatory
This OID reports the current state of the sensor.
A notPresent (0) response indicates that no sensor is attached. An alarmed (1) response indicates that the sensor is present and its measured reading indicates alarmed… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.6.4.1.4 |
||||||||||||||
|
pduExternalSensorStatusValue
mandatory
Sensor reading in pduExternalSensorConfigUnits value.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.6.4.1.5 |
||||||||||||||
|
pduExternalSensorStatusTimeStamp
mandatory
The sensor reading timestamp.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.6.4.1.6 |
||||||||||||||
|
pduExternalSensorStatusHighPrecisionValue
mandatory
Temperature sensor reading in tenths of pduExternalSensorConfigUnits value.
This OID is applied to temperature sensor only |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.6.4.1.7 |
.1.3.6.1.4.1.318.1.1.32.7.2
·
1 row entry
·
5 columns
A table of Smart Cabinet information
Information of Smart Cabinet
Indexes
pduUnitSmartCabinetIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
pduUnitSmartCabinetIndex
mandatory
The index of the PDU Smart Cabinet table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.7.2.1.1 |
||||
|
pduUnitSmartCabinetCardUserName
mandatory
User name of ID card
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.7.2.1.2 |
||||
|
pduUnitSmartCabinetCardID
mandatory
Card ID.
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.7.2.1.3 |
||||
|
pduUnitSmartCabinetTimestamp
mandatory
Indicates the date and time of information update
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.7.2.1.4 |
||||
|
pduUnitSmartCabinetDoor
mandatory
Aisle of Smart Cabinet.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.7.2.1.5 |
.1.3.6.1.4.1.318.1.1.32.7.4
·
1 row entry
·
5 columns
A table of Smart Cabinet aisle state control
Information of Smart Cabinet Lock State
Indexes
pduUnitSmartCabinetLockStateIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
pduUnitSmartCabinetLockStateIndex
mandatory
The index of the PDU Smart Cabinet table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.7.4.1.1 |
||||||
|
pduUnitSmartCabinetColdAisleLockState
mandatory
Smart Cabinet ColdAisle lock state
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.7.4.1.2 |
||||||
|
pduUnitSmartCabinetHotAisleLockState
mandatory
Smart Cabinet HotAisle lock state
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.7.4.1.3 |
||||||
|
pduUnitSmartCabinetColdAisleLockLabel
mandatory
Label of cold aisle smartcabinet
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.7.4.1.4 |
||||||
|
pduUnitSmartCabinetHotAisleLockLabel
mandatory
Label of hot aisle smartcabinet
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.7.4.1.5 |
.1.3.6.1.4.1.318.1.1.32.8.1.1
·
1 row entry
·
7 columns
A list of Trap Information entries. The number of entries are given by the value of pduUnitTableSize.
An entry containing objects used in traps
Indexes
trapsInfoIndex
| Column | Syntax | OID |
|---|---|---|
|
trapsInfoIndex
mandatory
The index of the traps table entry
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.1 |
|
userName
mandatory
The user currently logged in.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.2 |
|
userUpdated
mandatory
The user added, deleted, or modified.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.3 |
|
firmwareVersion
mandatory
The version of Firmware.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.4 |
|
roleUpdated
mandatory
The role added, deleted, or modified.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.5 |
|
smtpRecipients
mandatory
Comma separated list of SMTP recipients
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.6 |
|
smtpServer
mandatory
The IP address/host name of the SMTP server
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.8.1.1.1.7 |
.1.3.6.1.4.1.318.1.1.32.9.1
·
1 row entry
·
13 columns
A list of contact sensors. The number of entries are given by number of pdu and pduEhandleCount.
An entry for a contact sensor
Indexes
pduEhandleIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
pduEhandleIndex
mandatory
The index of the PDU HID table entry
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.318.1.1.32.9.1.1.1 |
||||
|
pduEhandleAisle
mandatory
Aisle of HID handle.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.9.1.1.2 |
||||
|
pduEhandleHandleOperation
mandatory
HID handle control opterations
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.9.1.1.3 |
||||
|
pduEhandleFwVer
mandatory
The firmware revision level of the HID
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.9.1.1.4 |
||||
|
pduEhandleMechanicalLock
mandatory
HID Mechanical opterations
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.9.1.1.5 |
||||
|
pduEhandleSerial
mandatory
The Serial Number of the HID
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.9.1.1.6 |
||||
|
pduEhandleHwVer
mandatory
The hardware revision level of the HID
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.9.1.1.7 |
||||
|
pduEhandleAutoLockTime
mandatory
HID Electronic Latch Autolock Time in seconds, Value ranges (0-999)
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.9.1.1.8 |
||||
|
pduEhandleDoorOpenTime
mandatory
HID Door Open Time in seconds, Value ranges (0-999)
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.9.1.1.9 |
||||
|
pduEhandleMaxDoorOpenTime
mandatory
HID Max Door Open Time in seconds, Value ranges (0-32400),
critical alarm will be raised if door is left open past this time |
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.9.1.1.10 |
||||
|
pduEhandleUserPinLength
mandatory
Rack Access User minimum PIN Length, value ranges(1-15)
|
Integer32r/w Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.32.9.1.1.11 |
||||
|
pduEhandleUserPinMode
mandatory
Rack Access User PIN mode setting
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.9.1.1.12 |
||||
|
pduEhandleAisleControl
mandatory
Rack Access Aisle Control setting,
when set to standalone each aisle will controlled seprately, when set to combined opposite aisle can be controlled with authenticated control action on either aisle |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.9.1.1.13 |
.1.3.6.1.4.1.318.1.1.32.9.2
·
1 row entry
·
9 columns
A list of smartcard. The number of entries are given by number of pdu and pduEhandleCount.
The smart card table entry containing the usrname, cardid, cardaisle etc.
Indexes
pduEhandleControlIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
pduEhandleControlIndex
mandatory
The index of the PDU smartcard table entry
|
Integer32 Constraints: range: 1-200 |
.1.3.6.1.4.1.318.1.1.32.9.2.1.1 |
||||||
|
pduEhandleControlUserName
mandatory
User name of smartcard
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.9.2.1.2 |
||||||
|
pduEhandleControlCardIdStr
mandatory
smartcard ID.
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.9.2.1.3 |
||||||
|
pduEhandleControlTimestamp
mandatory
Indicates the date and time of accessing
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.9.2.1.4 |
||||||
|
pduEhandleControlCardAisle
mandatory
Aisle of authorized card
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.9.2.1.5 |
||||||
|
pduEhandleControlStartTime
mandatory
Indicates the start date and time Rack access user is given access
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.9.2.1.6 |
||||||
|
pduEhandleControlExpireTime
mandatory
Indicates the date and time when the access of user card will expire, To set expire time first set user as temporary user
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.9.2.1.7 |
||||||
|
pduEhandleControlTempUser
mandatory
Indicates if the card user has temporary access
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.32.9.2.1.8 |
||||||
|
pduEhandleControlPin
mandatory
Rack acess control entry keypad PIN
|
RFC1213-MIBDisplayStringr/w Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.318.1.1.32.9.2.1.9 |