pduInputPhaseConfigVoltageEnabledThresholds
CPDU-MIB ·
.1.3.6.1.4.1.318.1.1.32.3.2.1.17
Object
column
mandatory
r/w
Bits
A bit string indicating which voltage alarm thresholds are enabled.
Context
- MIB
- CPDU-MIB
- OID
.1.3.6.1.4.1.318.1.1.32.3.2.1.17- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- pduInputPhaseConfigEntry
- Table
- pduInputPhaseConfigTable
- Siblings
- 16
Syntax
Bits
Values & Constraints
Enumerated Values
0 | lowerCritical |
1 | lowerWarning |
2 | upperWarning |
3 | upperCritical |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduInputPhaseConfigIndex mandatory The index of the PDU Input Phase configuration table entry | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.1 |
| pduInputPhaseConfigVoltageUpperCriticalThreshold mandatory User-defined upper critical input phase voltage alarm threshold in Volts(V). | column | Unsigned32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.10 |
| pduInputPhaseConfigVoltageUpperWarningThreshold mandatory User-defined upper non-critical (warning) input phase voltage alarm threshold in Volts(V). | column | Unsigned32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.11 |
| pduInputPhaseConfigCurrentAlarmResetThreshold mandatory The hysteresis used for current alarm deassertions in hundredths of Amps(A). | column | Unsigned32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.12 |
| pduInputPhaseConfigCurrentAlarmStateChangeDelay mandatory The delay measured in samples before a current state is asserted. If the
value is zero, then the state is asserted as soon as it is
detected; if it is non-zero, say n, then the … | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.13 |
| pduInputPhaseConfigCurrentEnabledThresholds mandatory A bit string indicating which current alarm thresholds are enabled. | column | Bits | .1.3.6.1.4.1.318.1.1.32.3.2.1.14 |
| pduInputPhaseConfigVoltageAlarmResetThreshold mandatory The hysteresis used for voltage alarm deassertions in Volts(V). | column | Unsigned32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.15 |
| pduInputPhaseConfigVoltageAlarmStateChangeDelay mandatory The delay measured in samples before a voltage state is asserted. If the
value is zero, then the state is asserted as soon as it is
detected; if it is non-zero, say n, then the … | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.16 |
| pduInputPhaseConfigCount mandatory The total number of Input Phases | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.2 |
| pduInputPhaseConfigOverloadRestriction mandatory This OID controls the behavior of a Switched PDU Input Phase when an
overload condition is possible and additional outlets are requested
to be turned on. Setting this OID to alw… | column | Enumeration | .1.3.6.1.4.1.318.1.1.32.3.2.1.3 |
| pduInputPhaseConfigCurrentLowerCriticalThreshold mandatory User-defined lower critical input phase current alarm threshold in hundredths of Amps(A). | column | Unsigned32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.4 |
| pduInputPhaseConfigCurrentLowerWarningThreshold mandatory User-defined lower non-critical (warning) input phase current alarm threshold in hundredths of Amps(A). | column | Unsigned32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.5 |
| pduInputPhaseConfigCurrentUpperCriticalThreshold mandatory User-defined upper critical input phase current alarm threshold in hundredths of Amps(A). | column | Unsigned32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.6 |
| pduInputPhaseConfigCurrentUpperWarningThreshold mandatory User-defined upper non-critical (warning) input phase current alarm threshold in hundredths of Amps(A). | column | Unsigned32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.7 |
| pduInputPhaseConfigVoltageLowerCriticalThreshold mandatory User-defined lower critical input phase voltage alarm threshold in Volts(V). | column | Unsigned32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.8 |
| pduInputPhaseConfigVoltageLowerWarningThreshold mandatory User-defined lower non-critical (warning) input phase voltage alarm threshold in Volts(V). | column | Unsigned32 | .1.3.6.1.4.1.318.1.1.32.3.2.1.9 |