pduUnitPropertiesOutletLayout
CPDU-MIB ·
.1.3.6.1.4.1.318.1.1.32.2.3.1.15
Object
column
mandatory
Enumeration
The outlet layout for the PDU. Getting this OID will return outlet layout for the device. seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... seqPhaseToPhase(2) indicates outlet layout as follows: 1:1-2,2:2-3,3:3-1,4:1-2,5:2-3,... seqPhToNeu21PhToPh(3) indicates outlet layout as follows: 1:1-N,2:2-N...21:3-N,22:1-2,23:2-3,24:3-1,... seqPhToPhGrouped(4) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-2, Group 2:2-3, Group 3:3-1. seqPhToNGrouped(5) indicates outlet layout as follows: This unit has 3 outlet groups. Group 1:1-N, Group 2:2-N, Group 3:3-N. seqPToN1516PToPGrouped(6) indicates outlet layout as follows: This unit has 4 outlet groups. Group 1 (Outlets 1-14):1-2, Group 2 (Outlets 15-16):1-N, Group 3:2-3, Group 4:3-1. seqPhToPh2xGrouped(7) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-2, Group 2:1-2, Group 3:2-3, Group 4:2-3, Group 5:3-1, Group 6:3-1. seqPhToN2xGrouped(8) indicates outlet layout as follows: This unit has 6 outlet groups. Group 1:1-N, Group 2:1-N, Group 3:2-N, Group 4:2-N, Group 5:3-N, Group 6:3-N. seqNotApplicable(9):
Context
- MIB
- CPDU-MIB
- OID
.1.3.6.1.4.1.318.1.1.32.2.3.1.15- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- pduUnitPropertiesEntry
- Table
- pduUnitPropertiesTable
- Siblings
- 15
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | seqPhaseToNuetral |
2 | seqPhaseToPhase |
3 | seqPhToNeu21PhToPh |
4 | seqPhToPhGrouped |
5 | seqPhToNGrouped |
6 | seqPToN1516PToPGrouped |
7 | seqPhToPh2xGrouped |
8 | seqPhToN2xGrouped |
9 | seqNotApplicable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduUnitPropertiesIndex mandatory The index of the PDU properties table entry | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.1 |
| pduUnitPropertiesRatedVoltage mandatory The PDU voltage rating in Volts | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.32.2.3.1.10 |
| pduUnitPropertiesRatedMaxCurrent mandatory The PDU current rating in Amps | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.32.2.3.1.11 |
| pduUnitPropertiesRatedFrequency mandatory The PDU frequency rating in Hz | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.32.2.3.1.12 |
| pduUnitPropertiesRatedPower mandatory The PDU VA (VoltAmps) rating. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.32.2.3.1.13 |
| pduUnitPropertiesOrientation mandatory The PDU orientation | column | Enumeration | .1.3.6.1.4.1.318.1.1.32.2.3.1.14 |
| pduUnitPropertiesCascadeMemberType mandatory The cascading member type | column | Enumeration | .1.3.6.1.4.1.318.1.1.32.2.3.1.16 |
| pduUnitPropertiesName mandatory A user-defined string identifying the PDU | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.32.2.3.1.2 |
| pduUnitPropertiesOutletCount mandatory The total number of outlets on the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.3 |
| pduUnitPropertiesSwitchedOutletCount mandatory The total number of switched outlets on the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.4 |
| pduUnitPropertiesMeteredOutletCount mandatory The total number of metered outlets on the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.5 |
| pduUnitPropertiesInputPhaseCount mandatory The total number of phases on the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.6 |
| pduUnitPropertiesCircuitBreakerCount mandatory The total number of circuit breaker on the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.7 |
| pduUnitPropertiesMaxExternalSensorCount mandatory The maximum number of external sensors that can be connected to the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.8 |
| pduUnitPropertiesConnExternalSensorCount mandatory The current number of external sensors connected to the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.9 |