pduUnitPropertiesRatedMaxCurrent
CPDU-MIB ·
.1.3.6.1.4.1.318.1.1.32.2.3.1.11
Object
The PDU current rating in Amps
Context
- MIB
- CPDU-MIB
- OID
.1.3.6.1.4.1.318.1.1.32.2.3.1.11- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- pduUnitPropertiesEntry
- Table
- pduUnitPropertiesTable
- Siblings
- 15
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduUnitPropertiesIndex mandatory The index of the PDU properties table entry | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.1 |
| pduUnitPropertiesRatedVoltage mandatory The PDU voltage rating in Volts | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.32.2.3.1.10 |
| pduUnitPropertiesRatedFrequency mandatory The PDU frequency rating in Hz | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.32.2.3.1.12 |
| pduUnitPropertiesRatedPower mandatory The PDU VA (VoltAmps) rating. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.32.2.3.1.13 |
| pduUnitPropertiesOrientation mandatory The PDU orientation | column | Enumeration | .1.3.6.1.4.1.318.1.1.32.2.3.1.14 |
| pduUnitPropertiesOutletLayout mandatory The outlet layout for the PDU. Getting this OID will return outlet layout for the device.
seqPhaseToNeutral(1) indicates outlet layout as follows:
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,..… | column | Enumeration | .1.3.6.1.4.1.318.1.1.32.2.3.1.15 |
| pduUnitPropertiesCascadeMemberType mandatory The cascading member type | column | Enumeration | .1.3.6.1.4.1.318.1.1.32.2.3.1.16 |
| pduUnitPropertiesName mandatory A user-defined string identifying the PDU | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.32.2.3.1.2 |
| pduUnitPropertiesOutletCount mandatory The total number of outlets on the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.3 |
| pduUnitPropertiesSwitchedOutletCount mandatory The total number of switched outlets on the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.4 |
| pduUnitPropertiesMeteredOutletCount mandatory The total number of metered outlets on the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.5 |
| pduUnitPropertiesInputPhaseCount mandatory The total number of phases on the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.6 |
| pduUnitPropertiesCircuitBreakerCount mandatory The total number of circuit breaker on the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.7 |
| pduUnitPropertiesMaxExternalSensorCount mandatory The maximum number of external sensors that can be connected to the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.8 |
| pduUnitPropertiesConnExternalSensorCount mandatory The current number of external sensors connected to the PDU | column | Integer32 | .1.3.6.1.4.1.318.1.1.32.2.3.1.9 |