.1.3.6.1.4.1.19536.10.1.1.2 · 1 row entry · 17 columns
Aggregate Object with number of entries equal to pdug5NumberPDU .
pdug5IdentEntry entry .1.3.6.1.4.1.19536.10.1.1.2.1
The Identity table entry containing the name, model, manufacturer,
firmware version, part number, etc.
Indexes
No indexes recorded
Column Syntax OID
pdug5IdentIndex
Index for the pdug5IdentEntry table.
Integer32 .1.3.6.1.4.1.19536.10.1.1.2.1.1
pdug5Name
The string identify the device in daisy chain. Example PDU A.
OctetStringr/w .1.3.6.1.4.1.19536.10.1.1.2.1.2
pdug5Model
The Device Model.
OctetString .1.3.6.1.4.1.19536.10.1.1.2.1.3
pdug5Manufacturer
The Device Manufacturer Name.
OctetString .1.3.6.1.4.1.19536.10.1.1.2.1.4
pdug5FirmwareVersion
The firmware revision level of the device.
OctetString .1.3.6.1.4.1.19536.10.1.1.2.1.5
pdug5FirmwareVersionTimeStamp
Timestamp of when the PDU firmware was last updated
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.1.2.1.6
pdug5PartNumber
The device part number. Example P36E09M.
OctetString .1.3.6.1.4.1.19536.10.1.1.2.1.7
pdug5SerialNumber
The device serial number, 10-digit.
OctetString .1.3.6.1.4.1.19536.10.1.1.2.1.8
pdug5Status
The overall status of the device. A value of OK(2) indicates the device is operating normally.
A value of degraded(3) indicates the device is operating with warning indicators. A value of
failed(4) indicates the devic…
Enumeration .1.3.6.1.4.1.19536.10.1.1.2.1.9
pdug5Controllable
This object indicates whether or not the device is controllable.
Enumeration .1.3.6.1.4.1.19536.10.1.1.2.1.10
pdug5InputPhaseCount
The number of input phase on this pdu 1 or 3.
Integer32 .1.3.6.1.4.1.19536.10.1.1.2.1.11
pdug5GroupCount
The number of groups (breakers) on this pdu.
Integer32 .1.3.6.1.4.1.19536.10.1.1.2.1.12
pdug5OutletCount
The number of outlets in this PDU.
Integer32 .1.3.6.1.4.1.19536.10.1.1.2.1.13
pdug5MACAddress
The assigned MAC address for this PDU.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.1.2.1.14
pdug5IPv4Address
The current IPv4 Address.
A value of 0.0.0.0 indicates an error or an unset option.
SNMPv2-SMIIpAddress
Textual Convention: SNMPv2-SMIIpAddress OctetString
Type Constraints:
range: 4
.1.3.6.1.4.1.19536.10.1.1.2.1.15
pdug5IPv6Address
The current IPv6 Address.
A value of 0.0.0.0.0.0 indicates an error or an unset option.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.1.2.1.16
pdug5HWVersion
The current Hardware Version.
1.0 - G5 (STM) No Powershare,
1.5 - G5 (STM) with Powershare,
2.0 - G6 Processor
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.1.2.1.17
.1.3.6.1.4.1.19536.10.1.1.3 · 1 row entry · 12 columns
Aggregate Object with number of entries equal to pdug5NumberPDU.
pdug5ConfigEntry entry .1.3.6.1.4.1.19536.10.1.1.3.1
Read Configuration data from the PDU being queried.
Indexes
No indexes recorded
Column Syntax OID
pdug5ConfigIndex
The index of PDU configuration entry.
Integer32 .1.3.6.1.4.1.19536.10.1.1.3.1.1
pdug5ConfigSsh
Setting this OID to off(0) will disable the SSH connection.
Setting this OID to on(1) will enable the SSH connection. iNC reboot will be required for the settings to take effect.
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.3.1.2
pdug5ConfigFtps
Setting this OID to off(0) will disable the FTPS connection.
Setting this OID to on(1) will enable the FTPS connection. iNC reboot will be required for the settings to take effect
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.3.1.3
pdug5ConfigHttp
Setting this OID to off(0) will disable the HTTP connection.
Setting this OID to on(1) will enable the HTTP connection.iNC reboot will be required for the settings to take effect
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.3.1.4
pdug5ConfigHttps
Setting this OID to off(0) will disable the HTTPS connection.
Setting this OID to on(1) will enable the HTTPS connection.iNC reboot will be required for the settings to take effect
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.3.1.5
pdug5ConfigIPv4IPv6Switch
Setting this OID to IPv4(1) will enable the IPv4 configuration.
Setting this OID to IPv6(2) will enable the IPv6 configuration.
Setting this OID to IPv4&IPv6(3) will enable both IPv4 and IPv6 configuration.iNC reboot wi…
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.3.1.6
pdug5ConfigRedfishAPI
Setting this OID to off(0) will disable the Redfish API.
Setting this OID to on(1) will enable the Redfish API.iNC reboot will be required for the settings to take effect
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.3.1.7
pdug5ConfigOledDispalyOrientation
Indicates the intended physical orientation of OLED display.
displayNormal(1) indicates normal orientation.
displayReverse(2) indicates upside down orientation.
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.3.1.8
pdug5ConfigEnergyReset
Setting this OID to reset(2) will cause the device energy meter value
to be reset to zero. Getting this OID in models that support this feature
will do nothing and return the noOperation(1) value. Models that do not
sup…
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.3.1.9
pdug5ConfigNetworkManagementCardReset
Getting this OID will return noOperation(0).
Getting this OID to reset(1) will reset iNC.
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.3.1.10
pdug5ConfigDaisyChainStatus
Setting this OID will change daisychain mode. 0:QNA,1:DNA.
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.3.1.11
pdug5ConfigTelnet
Setting this OID to off(0) will disable the Telnet connection.
Setting this OID to on(1) will enable the Telnet connection. iNC reboot will be required for the settings to take effect.
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.3.1.12
.1.3.6.1.4.1.19536.10.1.1.4 · 1 row entry · 7 columns
Aggregate Object with number of entries equal to number of PDUs and Power share
pdug5PowershareEntry entry .1.3.6.1.4.1.19536.10.1.1.4.1
The Power share entry containing the available, input, output etc.
Indexes
No indexes recorded
Column Syntax OID
pdug5PowershareIndex
The index of the PDU Power share table entry
Integer32 .1.3.6.1.4.1.19536.10.1.1.4.1.1
pdug5PowershareFunctionStatus
Power share function status on PDU.
Enumeration .1.3.6.1.4.1.19536.10.1.1.4.1.2
pdug5PowershareFunctionUpstreamStatus
Power share function status on upstream PDU
Enumeration .1.3.6.1.4.1.19536.10.1.1.4.1.3
pdug5PowershareOutput
Power share output status.
Enumeration .1.3.6.1.4.1.19536.10.1.1.4.1.4
pdug5PowershareInput
Power share input status.
Enumeration .1.3.6.1.4.1.19536.10.1.1.4.1.5
pdug5PowershareOptMode
Power share operation status of PDU. 0 meaning pdu is using powershare to power the NMC, 1 meaning pdu is using mains power to power the NMC
Enumeration .1.3.6.1.4.1.19536.10.1.1.4.1.6
pdug5PowershareFunc
Enable/Disable Powershare function of PDU. Set 1 to enable powershare. Set 0 to disable powershare
Enumerationr/w .1.3.6.1.4.1.19536.10.1.1.4.1.7
.1.3.6.1.4.1.19536.10.1.2.1 · 1 row entry · 11 columns
Aggregate Object with number of entries equal to pdug5NumberPDU .
pdug5InputEntry entry .1.3.6.1.4.1.19536.10.1.2.1.1
The ident table entry containing the VA, Watts, WH, etc.
Indexes
No indexes recorded
Column Syntax OID
pdug5InputType
Type of input - single phase, split phase, three phase delta, or three
phase wye.
Enumeration .1.3.6.1.4.1.19536.10.1.2.1.1.1
pdug5InputFrequency
The measured input frequency from the PDU meters in tenths of Hz.
Integer32 .1.3.6.1.4.1.19536.10.1.2.1.1.2
pdug5InputFrequencyStatus
Status of the measured input frequency relative to the nominal frequency and the admitted tolerance.
Enumeration .1.3.6.1.4.1.19536.10.1.2.1.1.3
pdug5InputPowerVA
A total input VA of all phases. Units are VA. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.1.1.4
pdug5InputPowerWatts
A total input Watts of all phases. Units are Watts. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.1.1.5
pdug5InputTotalEnergy
A total input Watt-Hour value for all phases. Units are KWh. This value is accumulated since PDU in service.
A negative value indicates that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.1.1.6
pdug5InputPowerWattHourTimer
A Timestamp of when the Total Input WH was last reset.
OctetString .1.3.6.1.4.1.19536.10.1.2.1.1.7
pdug5InputResettableEnergy
A total input Watt-Hour value for all phases. Units are Wh. This value can be reset to 0
using GUI. In that case, the pdug5InputPowerWattHourTimer will be reset as well
A negative value indicates that this object is no…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.1.1.8
pdug5InputPowerFactor
An input PF value. Units are in hundredths, for example a power factor
of 0.95 would be returned as 95, and 0.92 would be returned as 92.
A negative value indicates that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.1.1.9
pdug5InputPowerVAR
An input VAR value. Units are VAR. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.1.1.10
pdug5InputTotalCurrent
All phases total current value. Units are 0.01 amps.
For 3 phase, mathematically add totally 3 phase current together.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.1.1.11
.1.3.6.1.4.1.19536.10.1.2.2 · 1 row entry · 43 columns
Aggregate Object with number of entries equal to number of PDUs (pdug5NumberPDU) and
number of input phase (pdug5InputPhaseCount).
pdug5InputPhaseEntry entry .1.3.6.1.4.1.19536.10.1.2.2.1
The input table entry containing the voltage, current, frequency, power for each phase.
Entries are given with number of pdu and number of input phase 1, 2, or 3.
Indexes
No indexes recorded
Column Syntax OID
pdug5InputPhaseIndex
Index for the pdug5InputEntry table.
Integer32 .1.3.6.1.4.1.19536.10.1.2.2.1.1
pdug5InputPhaseVoltageMeasType
Value indicates what input voltage is being measured in this table row - single phase
voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2,
phase 2 to phase 3, or phase 3 to phase 1.
Enumeration .1.3.6.1.4.1.19536.10.1.2.2.1.2
pdug5InputPhaseVoltage
An input voltage measurement value. Values is in 0.1 V.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.3
pdug5InputPhaseVoltageThStatus
Status of the measured input voltage relative to the configured thresholds.
Enumeration .1.3.6.1.4.1.19536.10.1.2.2.1.4
pdug5InputPhaseVoltageThLowerWarning
Lower warning threshold. Units are 0.1 volts. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.5
pdug5InputPhaseVoltageThLowerCritical
Lower critical threshold. Units are 0.1 volts. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.6
pdug5InputPhaseVoltageThUpperWarning
Upper warning threshold. Units are 0.1 volts. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.7
pdug5InputPhaseVoltageThUpperCritical
Upper critical threshold. Units are 0.1 volts. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.8
pdug5InputPhaseCurrentMeasType
Which input wire is being measured in this table row - single phase, neutral, phase 1,
phase 2, or phase 3.
Enumeration .1.3.6.1.4.1.19536.10.1.2.2.1.9
pdug5InputPhaseCurrentRating
Rated current capacity of the input. A negative value indicates that
the hardware current capacity is unknown. Units are 0.01 amps.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.10
pdug5InputPhaseCurrent
An input current measurement value. Units are 0.01 amps.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.11
pdug5InputPhaseCurrentThStatus
Status of the measured input current relative to the configured thresholds.
Enumeration .1.3.6.1.4.1.19536.10.1.2.2.1.12
pdug5InputPhaseCurrentThLowerWarning
Lower warning threshold. Units are 0.01 amps. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.13
pdug5InputPhaseCurrentThLowerCritical
Lower critical threshold. Units are 0.01 amps. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.14
pdug5InputPhaseCurrentThUpperWarning
Upper warning threshold. Units are 0.01 amps. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.15
pdug5InputPhaseCurrentThUpperCritical
Upper critical threshold. Units are 0.01 amps. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.16
pdug5InputPhaseCurrentPercentLoad
Current percent load, based on the rated current capacity. Units are
percentage, for example 80% will be returned as 80. A negative
value indicates that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.17
pdug5InputPhasePowerMeasType
Which input wire is being measured in this table row - single phase, neutral, phase 1,
phase 2, or phase 3.
Enumeration .1.3.6.1.4.1.19536.10.1.2.2.1.18
pdug5InputPhasePowerVA
An input VA value. Units are VA. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.19
pdug5InputPhasePowerWatts
An input Watts value. Units are Watts. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.20
pdug5InputPhasePowerWattHour
A Watt-Hour value for each Input phase. Units are WH. This value can be reset to 0
using GUI. In that case, the pdug5InputPhasePowerWattHourTimer will be reset as well
A negative value indicates that this object is not…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.21
pdug5InputPhasePowerWattHourTimer
Timestamp of when input Watt-hours (inputWh) was last reset.
OctetString .1.3.6.1.4.1.19536.10.1.2.2.1.22
pdug5InputPhasePowerFactor
An input PF value. Units are in hundredths, for example a power factor
of 0.95 would be returned as 95, and 0.92 would be returned
as 92. A negative value indicates that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.23
pdug5InputPhasePowerVAR
An input VAR value. Units are VAR. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.24
pdug5InputPhaseVoltageThResetThld
The Reset threshold is the number of volts the reading needs to fall below
the threshold setting for the condition to be cleared. Units are 0.1 volts.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.25
pdug5InputPhaseVoltageThChangeDelay
The number of consecutive sample that the condition is present before
an alarm is raised.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.26
pdug5InputPhaseVoltageThCtrl
Input phase voltage alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disable
bit 2: low warning alarm control bit, 0 …
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.27
pdug5InputPhaseCurrentThResetThld
The Reset threshold is the number of amps the reading needs to fall below
the threshold setting for the condition to be cleared. Units are 0.01 amps.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.28
pdug5InputPhaseCurrentThChangeDelay
The number of consecutive sample that the condition is present before
an alarm is raised.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.29
pdug5InputPhaseCurrentThCtrl
Input phase current alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disable
bit 2: low warning alarm control bit, 0 …
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.30
pdug5InputPowerThresholdThLowerWarning
Lower warning Power threshold. Units are in Watts. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.31
pdug5InputPowerThresholdThLowerCritical
Lower critical Power threshold. Units are in Watts. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.32
pdug5InputPowerThresholdThUpperWarning
Upper warning Power threshold. Units are in Watts. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.33
pdug5InputPowerThresholdThUpperCritical
Upper critical Power threshold. Units are in Watts. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.34
pdug5InputPowerThresholdThResetThld
The Reset threshold is the number of watts the reading needs to fall below
the threshold setting for the condition to be cleared. Units are watts.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.35
pdug5InputPowerThresholdThChangeDelay
The number of consecutive sample that the condition is present before
an alarm is raised.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.36
pdug5InputPowerThresholdThCtrl
Power alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disable
bit 2: low warning alarm control bit, 0 - enable, 1 -…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.37
pdug5InputEnergyThresholdThUpperWarning
Upper warning Energy threshold. Units are in Watts. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.38
pdug5InputEnergyThresholdThUpperCritical
Upper critical Energy threshold. Units are in Watts. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.39
pdug5InputEnergyThresholdThResetThld
The Reset threshold is the number of watts the reading needs to fall below
the threshold setting for the condition to be cleared. Units are watts.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.40
pdug5InputEnergyThresholdThChangeDelay
The number of consecutive sample that the condition is present before
an alarm is raised.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.2.1.41
pdug5InputEnergyThresholdThCtrl
Energy alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disable
bit 2: low warning alarm control bit, 0 - enable, 1 …
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.2.1.42
pdug5InputPhasePowerThStatus
Status of the measured input current relative to the configured thresholds.
Enumeration .1.3.6.1.4.1.19536.10.1.2.2.1.43
.1.3.6.1.4.1.19536.10.1.2.3 · 1 row entry · 9 columns
Aggregate Object with number of entries equal to number of PDUs (pdug5NumberPDU) and
number of RCM modules per PDU.
pdug5InputRcmEntry entry .1.3.6.1.4.1.19536.10.1.2.3.1
The ident table entry containing the RCM Module status, RCM current, RCM module threshold settings, etc.
Indexes
No indexes recorded
Column Syntax OID
pdug5InputRcmEnabled
RCM configuration value
off(0) if the PDU doesn't have RCM,
on(1) if the PDU has RCM.
Enumeration .1.3.6.1.4.1.19536.10.1.2.3.1.1
pdug5InputRcmModStatus
RCM module status
ok(2) if the PDU can communicate with the RCM module,
failed(4) if the PDU cannot communicate with the RCM module,
degraded(3) if the PDU can communicate with the RCM module and the last self-test fail…
Enumeration .1.3.6.1.4.1.19536.10.1.2.3.1.2
pdug5InputRcmThUpperWarning
RCM Current Upper warning threshold. Units are 0.01 amps.
A negative value indicates that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.3.1.3
pdug5InputRcmThUpperCritical
RCM Current Upper critical threshold. Units are 0.01 amps.
A negative value indicates that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.3.1.4
pdug5InputRcmThResetThld
The Reset threshold is the number of amps the reading needs to fall below
the threshold setting for the condition to be cleared. Units are 0.01 amps.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.3.1.5
pdug5InputRcmThChangeDelay
The number of consecutive sample that the condition is present before
an alarm is raised.
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.3.1.6
pdug5InputRcmThCtrl
Rcm current alarm threshold control:
0 - Enable UC and UW
1 - Disable UC and Enable UW
2 - Enable UC and Disable UW
3 - Disable UC and UW
4 and above - Bad input
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.3.1.7
pdug5InputRcmThStatus
Status of the measured Rcm current relative to the configured thresholds.
Enumeration .1.3.6.1.4.1.19536.10.1.2.3.1.8
pdug5InputRcmCurrent
Rcm module current reading. Units are milliAmps.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.2.3.1.9
.1.3.6.1.4.1.19536.10.1.2.4 · 1 row entry · 10 columns
Aggregate Object with number of entries equal to number of PDUs (pdug5NumberPDU) and
number of Rcm modules per PDU.
pdug5InputRcmSelfTestEntry entry .1.3.6.1.4.1.19536.10.1.2.4.1
The ident table entry containing the Rcm Module Self Test Enable, Schedule, LastRunTime,LastRunStatus etc.
Indexes
No indexes recorded
Column Syntax OID
pdug5InputRcmSelfTestEnable
Rcm Self Test configuration value
Disable(0) if the self test is disabled on the PDU,
Enable(1) if self test is enabled on the PDU .
Enumerationr/w .1.3.6.1.4.1.19536.10.1.2.4.1.1
pdug5InputRcmSelfTestFreq
Rcm module self test run frequency , the time for the test is set from Pdug5RcmSelfTestNextRunTime, the self test will be repeated based on the setting as Daily(1),Weekly(2),First Day Of Month(3),Yearly(4)
Enumerationr/w .1.3.6.1.4.1.19536.10.1.2.4.1.2
pdug5InputRcmSelfTestHour
Rcm module self test schedule hour setting (0 to 23 hour),-1 means feature not available
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.4.1.3
pdug5InputRcmSelfTestMinute
Rcm module self test schedule minute setting (0 to 59 minute),-1 means feature not available
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.4.1.4
pdug5InputRcmSelfTestDay
Rcm module self test schedule day setting
- Can be 0 to 6 when pduInputRcmSelfTestFreq is weekly(2),
- Can be 1 to 31 when pduInputRcmSelfTestFreq is monthly(3) or yearly(4),
- (-1) means feature not available
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.4.1.5
pdug5InputRcmSelfTestMonth
Rcm module self test schedule month setting,-1 means feature not available
Enumerationr/w .1.3.6.1.4.1.19536.10.1.2.4.1.6
pdug5InputRcmSelfTestNextRunTime
next run date and Time for self test.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.2.4.1.7
pdug5InputRcmSelfTestLastRunTime
Date and Time when the self test run previously
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.2.4.1.8
pdug5InputRcmSelfTestLastRunStatus
Status of the lastest self test run
Enumeration .1.3.6.1.4.1.19536.10.1.2.4.1.9
pdug5InputRcmSelfTest
Rcm module on demand self test, 1 to start the on demand self test
Integer32r/w .1.3.6.1.4.1.19536.10.1.2.4.1.10
.1.3.6.1.4.1.19536.10.1.3.1 · 1 row entry · 28 columns
Aggregate Object with number of entries equal to number of PDUs
and number of breakers (pdug5GroupCount).
pdug5GroupEntry entry .1.3.6.1.4.1.19536.10.1.3.1.1
The input table entry containing the name, voltages, currents, power, etc.
Indexes
No indexes recorded
Column Syntax OID
pdug5GroupIndex
Index for the pdug5GroupEntry table.
Integer32 .1.3.6.1.4.1.19536.10.1.3.1.1.1
pdug5GroupName
A descriptive name for the group.
OctetStringr/w .1.3.6.1.4.1.19536.10.1.3.1.1.2
pdug5GroupType
The type of the group. (5) has no breaker
Enumeration .1.3.6.1.4.1.19536.10.1.3.1.1.3
pdug5GroupVoltageMeasType
Value indicates what input voltage is being measured in this table row - single phase
voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2,
phase 2 to phase 3, or phase 3 to phase 1.
Enumeration .1.3.6.1.4.1.19536.10.1.3.1.1.4
pdug5GroupVoltage
Units are 0.1 volts.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.3.1.1.5
pdug5GroupVoltageThStatus
Status of the measured group voltage relative to the configured thresholds.
Enumeration .1.3.6.1.4.1.19536.10.1.3.1.1.6
pdug5GroupVoltageThLowerWarning
Lower warning threshold. Units are 0.1 volts. A negative value indicates
that this object is not available.
Integer32 .1.3.6.1.4.1.19536.10.1.3.1.1.7
pdug5GroupVoltageThLowerCritical
Lower critical threshold. Units are 0.1 volts. A negative value indicates
that this object is not available.
Integer32 .1.3.6.1.4.1.19536.10.1.3.1.1.8
pdug5GroupVoltageThUpperWarning
Upper warning threshold. Units are 0.1 volts. A negative value indicates
that this object is not available.
Integer32 .1.3.6.1.4.1.19536.10.1.3.1.1.9
pdug5GroupVoltageThUpperCritical
Upper critical threshold. Units are 0.1 volts. A negative value indicates
that this object is not available.
Integer32 .1.3.6.1.4.1.19536.10.1.3.1.1.10
pdug5groupCurrentRating
Rated current capacity of the group. Units are 0.01 amps. A negative
value indicates that the hardware current capacity is unknown (it
will always be unknown for custom groups).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.3.1.1.11
pdug5GroupCurrent
A group current measurement value. Units are 0.01 amps.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.3.1.1.12
pdug5GroupCurrentThStatus
Status of the measured group current relative to the configured thresholds.
Enumeration .1.3.6.1.4.1.19536.10.1.3.1.1.13
pdug5GroupCurrentThLowerWarning
Lower warning threshold. Units are 0.01 amps. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.3.1.1.14
pdug5GroupCurrentThLowerCritical
Lower critical threshold. Units are 0.01 amps. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.3.1.1.15
pdug5GroupCurrentThUpperWarning
Upper warning threshold. Units are 0.01 amps. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.3.1.1.16
pdug5GroupCurrentThUpperCritical
Upper critical threshold. Units are 0.01 amps. A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.3.1.1.17
pdug5GroupCurrentPercentLoad
Current percent load, based on the rated current capacity. Units are
percentage, for example 80% will be returned as 80. A negative
value indicates that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.3.1.1.18
pdug5GroupPowerVA
A group VA value. Units are VA. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.3.1.1.19
pdug5GroupPowerWatts
A group power value. Units are Watts. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.3.1.1.20
pdug5GroupPowerWattHour
A Watt-Hour value for each section. Units are WH. This value can be reset to 0
using GUI. In that case, the pdug5GroupPowerWattHourTimer will be reset as well.
A negative value indicates that this object is not availab…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.3.1.1.21
pdug5GroupPowerWattHourTimer
Timestamp of when group Watt-hours (groupWh) was last reset.
OctetString .1.3.6.1.4.1.19536.10.1.3.1.1.22
pdug5GroupPowerFactor
A group PF value. Units are in hundredths, for example a power factor
of 0.95 would be returned as 95, and 0.92 would be returned as 92.
A negative value indicates that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.3.1.1.23
pdug5GroupPowerVAR
A group VAR value. Units are VAR. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.3.1.1.24
pdug5GroupOutletCount
The number of outlets in each group (breaker).
Integer32 .1.3.6.1.4.1.19536.10.1.3.1.1.25
pdug5GroupBreakerStatus
Only applicable to groups with breaker. Indicates whether a breaker is turned
off or on.
Enumeration .1.3.6.1.4.1.19536.10.1.3.1.1.26
pdug5GroupVoltageThCtrl
Circuit Breaker voltage alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disable
bit 2: low warning alarm control bit…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.3.1.1.27
pdug5GroupCurrentThCtrl
Circuit Breaker current alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disable
bit 2: low warning alarm control bit…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.3.1.1.28
.1.3.6.1.4.1.19536.10.1.4.1 · 1 row entry · 8 columns
A list of environment probe (1 per PDU) for temperature, humidity, and contacts.
The number of entries is given by number of PDUs in daisy chain.
pdug5EnvProbeEntry entry .1.3.6.1.4.1.19536.10.1.4.1.1
Aggregate entries equal to number of PDUs.
Indexes
No indexes recorded
Column Syntax OID
pdug5TemperatureScale
Scale used to return temperature objects.
Enumerationr/w .1.3.6.1.4.1.19536.10.1.4.1.1.1
pdug5TemperatureCount
The number of temperature measurements.The MAX is 6 (1 per probe).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.1.1.2
pdug5HumidityCount
The number of humidity measurements.The MAX is 6(1 per probe).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.1.1.3
pdug5DoorCount
The number of door sensors.The MAX is 6(1 per probe).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.1.1.4
pdug5DryCount
The number of dry sensors.The MAX is 2(1 per probe).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.1.1.5
pdug5SpotCount
The number of spot sensors.The MAX is 2(1 per probe).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.1.1.6
pdug5RopeCount
The number of rope sensors.The MAX is 2(1 per probe).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.1.1.7
pdug5HidCount
The number of hid sensors. The MAX is 2(1 per probe).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.1.1.10
.1.3.6.1.4.1.19536.10.1.4.2 · 1 row entry · 10 columns
A list of temperature probe measurements.  The number of entries are
given by number of pdu and pdug5TemperatureCount.
pdug5TemperatureEntry entry .1.3.6.1.4.1.19536.10.1.4.2.1
An entry for a temperature measurement.
Indexes
No indexes recorded
Column Syntax OID
pdug5TemperatureIndex
A unique value for each temperature probe measurement. Its value
ranges from 1 to temperatureCount.
Integer32 .1.3.6.1.4.1.19536.10.1.4.2.1.1
pdug5TemperatureName
A descriptive name for the temperature probe.
OctetStringr/w .1.3.6.1.4.1.19536.10.1.4.2.1.2
pdug5TemperatureProbeStatus
Indicates whether a probe is connected or not.
Enumeration .1.3.6.1.4.1.19536.10.1.4.2.1.3
pdug5TemperatureValue
Units are degree(either Fahrenheit or Celsius).
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.2.1.4
pdug5TemperatureThStatus
Status of the measured temperature relative to the configured thresholds.
Enumeration .1.3.6.1.4.1.19536.10.1.4.2.1.5
pdug5TemperatureThLowerWarning
Lower warning threshold. Units are degrees. A negative value
indicates that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.4.2.1.6
pdug5TemperatureThLowerCritical
Lower critical threshold. Units are degrees. A negative value
indicates that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.4.2.1.7
pdug5TemperatureThUpperWarning
Upper warning threshold. Units are degrees. A negative value
indicates that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.4.2.1.8
pdug5TemperatureThUpperCritical
Upper critical threshold. Units are degrees. A negative value
indicates that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.4.2.1.9
pdug5TemperatureThCtrl
Temperature alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disable
bit 2: low warning alarm control bit, 0 - enabl…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.2.1.10
.1.3.6.1.4.1.19536.10.1.4.3 · 1 row entry · 10 columns
A list of humidity probe measurements.  The number of entries are
given by number of pdu and pdug5HumidityCount.
pdug5HumidityEntry entry .1.3.6.1.4.1.19536.10.1.4.3.1
An entry for a humidity measurement.
Indexes
No indexes recorded
Column Syntax OID
pdug5HumidityIndex
A unique value for each humidity probe measurement. Its value
ranges from 1 to pdug5HumidityCount per PDU.
Integer32 .1.3.6.1.4.1.19536.10.1.4.3.1.1
pdug5HumidityName
A descriptive name for the humidity probe.
OctetStringr/w .1.3.6.1.4.1.19536.10.1.4.3.1.2
pdug5HumidityProbeStatus
Indicates whether a probe is connected or not.
Enumeration .1.3.6.1.4.1.19536.10.1.4.3.1.3
pdug5HumidityValue
Units are %RH.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.3.1.4
pdug5HumidityThStatus
Status of the measured humidity relative to the configured thresholds.
Enumeration .1.3.6.1.4.1.19536.10.1.4.3.1.5
pdug5HumidityThLowerWarning
Lower warning threshold. Units are %RH. A negative value
indicates that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.4.3.1.6
pdug5HumidityThLowerCritical
Lower critical threshold. Units are %RH. A negative value
indicates that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.4.3.1.7
pdug5HumidityThUpperWarning
Upper warning threshold. Units are %RH. A negative value
indicates that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.4.3.1.8
pdug5HumidityThUpperCritical
Upper critical threshold. Units are %RH. A negative value
indicates that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.4.3.1.9
pdug5HumidityThCtrl
Humidity alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disable
bit 2: low warning alarm control bit, 0 - enable, …
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.3.1.10
.1.3.6.1.4.1.19536.10.1.4.4 · 1 row entry · 4 columns
A list of door sensors.  The number of entries are
given by number of PDU and pdug5DoorCount.
pdug5DoorEntry entry .1.3.6.1.4.1.19536.10.1.4.4.1
An entry for a door sensor
Indexes
No indexes recorded
Column Syntax OID
pdug5DoorIndex
A unique value for each door sensor. Its value ranges from 1 to
doorCount.
Integer32 .1.3.6.1.4.1.19536.10.1.4.4.1.1
pdug5DoorName
A descriptive name for the door sensor.
OctetStringr/w .1.3.6.1.4.1.19536.10.1.4.4.1.2
pdug5DoorProbeStatus
Indicates whether a probe is connected or not.
Will not be returned if the door sensor is internal to the ePDU,
in that case only doorState should be read.
Enumeration .1.3.6.1.4.1.19536.10.1.4.4.1.3
pdug5DoorState
The state of the door sensor.
Enumeration .1.3.6.1.4.1.19536.10.1.4.4.1.4
.1.3.6.1.4.1.19536.10.1.4.5 · 1 row entry · 4 columns
A list of dry sensors.  The number of entries are
given by number of pdu and pdug5DryCount.
pdug5DryEntry entry .1.3.6.1.4.1.19536.10.1.4.5.1
An entry for a contact sensor
Indexes
No indexes recorded
Column Syntax OID
pdug5DryIndex
A unique value for each dry sensor. Its value ranges from 1 to
dryCount.
Integer32 .1.3.6.1.4.1.19536.10.1.4.5.1.1
pdug5DryName
A descriptive name for the dry sensor.
OctetStringr/w .1.3.6.1.4.1.19536.10.1.4.5.1.2
pdug5DryProbeStatus
Indicates whether a probe is connected or not.
Enumeration .1.3.6.1.4.1.19536.10.1.4.5.1.3
pdug5DryState
The state of the dry sensor.
Enumeration .1.3.6.1.4.1.19536.10.1.4.5.1.4
.1.3.6.1.4.1.19536.10.1.4.6 · 1 row entry · 4 columns
A list of contact sensors.  The number of entries are
given by number of pdu and pdug5SpotCount.
pdug5SpotEntry entry .1.3.6.1.4.1.19536.10.1.4.6.1
An entry for a contact sensor
Indexes
No indexes recorded
Column Syntax OID
pdug5SpotIndex
A unique value for each spot sensor. Its value ranges from 1 to
spotCount.
Integer32 .1.3.6.1.4.1.19536.10.1.4.6.1.1
pdug5SpotName
A descriptive name for the spot sensor.
OctetStringr/w .1.3.6.1.4.1.19536.10.1.4.6.1.2
pdug5SpotProbeStatus
Indicates whether a probe is connected or not.
Enumeration .1.3.6.1.4.1.19536.10.1.4.6.1.3
pdug5SpotState
The state of the spot sensor.
Enumeration .1.3.6.1.4.1.19536.10.1.4.6.1.4
.1.3.6.1.4.1.19536.10.1.4.7 · 1 row entry · 4 columns
A list of rope sensors.  The number of entries are
given by number of pdu and pdug5RopeCount.
pdug5RopeEntry entry .1.3.6.1.4.1.19536.10.1.4.7.1
An entry for a contact sensor
Indexes
No indexes recorded
Column Syntax OID
pdug5RopeIndex
A unique value for each rope sensor. Its value ranges from 1 to
ropeCount.
Integer32 .1.3.6.1.4.1.19536.10.1.4.7.1.1
pdug5RopeName
A descriptive name for the rope sensor.
OctetStringr/w .1.3.6.1.4.1.19536.10.1.4.7.1.2
pdug5RopeProbeStatus
Indicates whether a probe is connected or not.
Enumeration .1.3.6.1.4.1.19536.10.1.4.7.1.3
pdug5RopeState
The state of the rope sensor.
Enumeration .1.3.6.1.4.1.19536.10.1.4.7.1.4
.1.3.6.1.4.1.19536.10.1.4.10.1 · 1 row entry · 15 columns
A list of contact sensors.  The number of entries are
given by number of pdu and pdug5HidCount.
pdug5EnvHidEntry entry .1.3.6.1.4.1.19536.10.1.4.10.1.1
An entry for a contact sensor
Indexes
No indexes recorded
Column Syntax OID
pdug5HIDIndex
The index of the PDU HID table entry
Integer32 .1.3.6.1.4.1.19536.10.1.4.10.1.1.1
pdug5HidAisle
Aisle of HID handle.
Enumeration .1.3.6.1.4.1.19536.10.1.4.10.1.1.2
pdug5HidHandleOperation
HID handle control operations
Enumerationr/w .1.3.6.1.4.1.19536.10.1.4.10.1.1.3
pduHIDVer
The firmware revision level of the HID
OctetString .1.3.6.1.4.1.19536.10.1.4.10.1.1.4
pdug5MechanicalLock
HID Mechanical operations
Enumeration .1.3.6.1.4.1.19536.10.1.4.10.1.1.5
pduHIDSerial
The Serial Number of the HID
OctetString .1.3.6.1.4.1.19536.10.1.4.10.1.1.6
pduHIDHwVer
The hardware revision level of the HID
OctetString .1.3.6.1.4.1.19536.10.1.4.10.1.1.7
pdug5HIDAutoLockTime
HID Electronic Latch Autolock Time in seconds, Value ranges (0-999)
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.10.1.1.8
pdug5HIDDoorOpenTime
HID Door Open Time in seconds, Value ranges (0-999)
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.10.1.1.9
pdug5HIDMaxDoorOpenTime
HID Max Door Open Time in seconds, Value ranges (0-32400),
critical alarm will be raised if door is left open past this time
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.10.1.1.10
pdug5HIDUserPinLength
Rack Access User minimum PIN Length, value ranges(0-16)
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.10.1.1.11
pdug5HIDUserPinMode
Rack Access User PIN mode setting
Enumerationr/w .1.3.6.1.4.1.19536.10.1.4.10.1.1.12
pdug5HIDAisleControl
Rack Access Aisle Control setting,
when set to standalone each aisle will controlled separately,
when set to combined opposite aisle can be controlled with authenticated control action on either aisle
Enumerationr/w .1.3.6.1.4.1.19536.10.1.4.10.1.1.13
pdug5HIDBeaconFuncControl
Beacon Function Control
Enumerationr/w .1.3.6.1.4.1.19536.10.1.4.10.1.1.14
pdug5HidBeaconColorControl
Beacon Color Control
Enumerationr/w .1.3.6.1.4.1.19536.10.1.4.10.1.1.15
.1.3.6.1.4.1.19536.10.1.4.10.2 · 1 row entry · 10 columns
A list of smartcard.  The number of entries are
given by number of pdu and pdug5HidCount.
pdug5EnvHidControlEntry entry .1.3.6.1.4.1.19536.10.1.4.10.2.1
The smart card table entry containing the username, cardid, cardaisle etc.
Indexes
No indexes recorded
Column Syntax OID
pdug5HidControlIndex
The index of the PDU smartcard table entry
Integer32 .1.3.6.1.4.1.19536.10.1.4.10.2.1.1
pdug5HidControlUserName
User name of smartcard.
Use #delete# to delete the HID user
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.4.10.2.1.2
pdug5HidControlCardID
HID smartcard ID.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.4.10.2.1.3
pdug5HidControlTimestamp
Indicates the date and time of accessing
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.4.10.2.1.4
pdug5HidControlCardAisle
Aisle of authorized card
Enumerationr/w .1.3.6.1.4.1.19536.10.1.4.10.2.1.5
pdug5HidControlStartTime
Indicates the start date and time Rack access user is given access
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.4.10.2.1.6
pdug5HidControlExpireTime
Indicates the date and time when the access of user card will expire, To set expire time first set user as temporary user
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.4.10.2.1.7
pdug5HidControlTempUser
Indicates if the card user has temporary access
Enumerationr/w .1.3.6.1.4.1.19536.10.1.4.10.2.1.8
pdug5HidControlPin
Rack access control entry keypad PIN
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.4.10.2.1.9
pdug5HidControlCardIdStr
Smartrack Access Card ID String
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.4.10.2.1.10
.1.3.6.1.4.1.19536.10.1.5.1 · 1 row entry · 21 columns
Aggregate Object with number of entries equal to Number of PDU (pdug5IdentIndex)
and Number of outlet per PDU (pdug5OutletIndex).
pdug5OutletEntry entry .1.3.6.1.4.1.19536.10.1.5.1.1
The Outlet table entry containing the type, voltage, current etc.
Indexes
No indexes recorded
Column Syntax OID
pdug5OutletIndex
Index for each outlet, value from 1 to the number of outlets per PDU.
Integer32 .1.3.6.1.4.1.19536.10.1.5.1.1.1
pdug5OutletName
A descriptive name for the outlet.
OctetStringr/w .1.3.6.1.4.1.19536.10.1.5.1.1.2
pdug5OutletType
Type of this outlet - C13, C19, 5-20R, iecC13/C15 COMBO, iecC13/C15/C19 COMBO...
Enumeration .1.3.6.1.4.1.19536.10.1.5.1.1.3
pdug5OutletCurrentRating
Rated current capacity of this outlet. Units are 0.01 amps. A negative
value indicates that the hardware current capacity is unknown.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.1.1.4
pdug5OutletCurrent
A outlet current measurement value. Units are 0.01 amps.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.1.1.5
pdug5OutletActivePowerThStatus
Status of the measured outlet active power relative to the configured thresholds.
Enumeration .1.3.6.1.4.1.19536.10.1.5.1.1.6
pdug5OutletActivePowerThLowerWarning
Lower warning threshold. Units are Watts(W). A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.1.1.7
pdug5OutletActivePowerThLowerCritical
Lower critical threshold. Units are Watts(W). A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.1.1.8
pdug5OutletActivePowerThUpperWarning
Upper warning threshold. Units are Watts(W). A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.1.1.9
pdug5OutletActivePowerThUpperCritical
Upper critical threshold. Units are Watts(W). A negative value indicates
that this object is not available.
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.1.1.10
pdug5OutletCurrentPercentLoad
Current percent load, based on the rated current capacity. Units are
percentage, for example 80% will be returned as 80. A negative
value indicates that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.1.1.11
pdug5OutletVA
A outlet VA value. Units are VA. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.1.1.12
pdug5OutletWatts
A outlet Watts value. Units are Watts. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.1.1.13
pdug5OutletWh
A Watt-Hour value for each outlet. Units are WH.
This object is writable so that it can be reset to 0. When it is
written to, the pdug5OutletWhTimer will be reset updated as well
A negative value indicates that this o…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.1.1.14
pdug5OutletWhTimer
Timestamp (date and time) of outlet Watt-hours was last reset.
OctetString .1.3.6.1.4.1.19536.10.1.5.1.1.15
pdug5OutletPowerFactor
An outlet PF value. Units are in hundredths, for example a power factor
of 0.95 would be returned as 95, and 0.92 would be returned
as 92. A negative value indicates that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.1.1.16
pdug5OutletVAR
An outlet VAR value. Units are VAR. A negative value indicates
that this object is not available.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.1.1.17
pdug5OutletBranch
The branch number outlet located.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.1.1.18
pdug5OutletActivePowerThResetThld
The Reset threshold is the number of watss the reading needs to fall below
the threshold setting for the condition to be cleared. Units are watts.
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.1.1.19
pdug5OutletActivePowerThChangeDelay
The number of consecutive sample that the condition is present before
an alarm is raised.
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.1.1.20
pdug5OutletActivePowerThCtrl
Outlet Active Power alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disable
bit 2: low warning alarm control bit, 0 …
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.1.1.21
.1.3.6.1.4.1.19536.10.1.5.2 · 1 row entry · 10 columns
Aggregate Object with number of entries equal to Number of PDU (pdug5IdentIndex)
and Number of outlets per PDU (pdug5OutletIndex).
pdug5OutletControlEntry entry .1.3.6.1.4.1.19536.10.1.5.2.1
The Outlet table entry containing the type, voltage, current etc.
Indexes
No indexes recorded
Column Syntax OID
pdug5OutletControlStatus
current state of a control outlet.
Enumeration .1.3.6.1.4.1.19536.10.1.5.2.1.1
pdug5OutletControlOffCmd
When write, once issued, the outlet will turn Off immediately.
0-n: Time in seconds until the outlet command is issued
-1: Cancel a pending outlet Off command
When read, returns -1 if no command is pending, or the curre…
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.2.1.2
pdug5OutletControlOnCmd
When write, once issued, the outlet will turn On immediately.
0-n: Time in seconds until the outlet command is issued
-1: Cancel a pending outlet On command
When read, returns -1 if no command is pending, or the current…
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.2.1.3
pdug5OutletControlRebootCmd
When write, for outlets that are On prior to this Reboot command, they will
switch Off immediately when the command is issued, remain Off for
outletControlRebootOffTime seconds, and then turn back On.
For outlets that a…
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.2.1.4
pdug5OutletControlPowerOnState
Determines the outlet state when power is applied to the unit.
1 : not restart at device startup
2 : should sequence back ON in line with outletControlSequenceTime
3 : should take the state the outlet had when power was…
Enumerationr/w .1.3.6.1.4.1.19536.10.1.5.2.1.5
pdug5OutletControlSequenceDelay
Time delay in seconds from when a Global Sequence On command is issued to when
the command is executed on this outlet. This delay is also used as a power-on delay.
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.2.1.6
pdug5OutletControlRebootOffTime
Time delay in seconds that the outlet should remain in the Off state when executing a Reboot command.
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.2.1.7
pdug5OutletControlSwitchable
Determines the outlet capability to be controlled On/Off from the communication channels.
1 : control On/Off enabled
2 : control On/Off disabled.
Enumerationr/w .1.3.6.1.4.1.19536.10.1.5.2.1.8
pdug5OutletControlShutoffDelay
Time delay in seconds that could be taken in account before shutting of the outlet.
An application which need to shutoff properly an outlet will read this parameter first
then write it to the command pdug5OutletControlO…
Integer32r/w .1.3.6.1.4.1.19536.10.1.5.2.1.9
pdug5OutletControlCommand
Getting this variable will return the outlet state.
If the outlet is on, the immediateOn (2)
value will be returned. If the outlet is off,
the immediateOff (1) value will be returned.
If the state of the outlet cannot b…
Enumerationr/w .1.3.6.1.4.1.19536.10.1.5.2.1.10
.1.3.6.1.4.1.19536.10.1.5.3 · 1 row entry · 6 columns
Aggregate Object with Number of outlets per Group (pdug5OutletGroupsIndex).
pdug5OutletGroupEntry entry .1.3.6.1.4.1.19536.10.1.5.3.1
The Outlet Group table entry containing the count, name, member etc.
Indexes
No indexes recorded
Column Syntax OID
pdug5OutletGroupCount
The numeric Switched Outlet Groups Count
Integer32 .1.3.6.1.4.1.19536.10.1.5.3.1.1
pdug5OutletGroupName
The user-defined switched outlet Groups Name string
OctetStringr/w .1.3.6.1.4.1.19536.10.1.5.3.1.2
pdug5OutletGroupMemberID
The user-defined switched outlet Group Members string
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.5.3.1.3
pdug5OutletGroupControl
Getting this variable will return the group state.
If the group is on, the immediateOn (2)
value will be returned. If the group is off,
the immediateOff (1) value will be returned.
If the state of the group cannot be de…
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.19536.10.1.5.3.1.4
pdug5OutletGroupActivePower
The Sum of Active power of all Grouped Outlet.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.3.1.5
pdug5OutletGroupApparentPower
The Sum of Apparent power of all Grouped Outlet.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.19536.10.1.5.3.1.6