pdug5GroupCurrent
PANDUIT-MIB ·
.1.3.6.1.4.1.19536.10.1.3.1.1.12
Object
column
SNMPv2-SMIInteger32
A group current measurement value. Units are 0.01 amps.
Context
- MIB
- PANDUIT-MIB
- OID
.1.3.6.1.4.1.19536.10.1.3.1.1.12- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pdug5GroupEntry
- Table
- pdug5GroupTable
- Siblings
- 27
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pdug5GroupIndex Index for the pdug5GroupEntry table. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.3.1.1.1 |
| pdug5GroupVoltageThUpperCritical Upper critical threshold. Units are 0.1 volts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.3.1.1.10 |
| pdug5groupCurrentRating Rated current capacity of the group. Units are 0.01 amps. A negative
value indicates that the hardware current capacity is unknown (it
will always be unknown for custom groups). | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.3.1.1.11 |
| pdug5GroupCurrentThStatus Status of the measured group current relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.19536.10.1.3.1.1.13 |
| pdug5GroupCurrentThLowerWarning Lower warning threshold. Units are 0.01 amps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.3.1.1.14 |
| pdug5GroupCurrentThLowerCritical Lower critical threshold. Units are 0.01 amps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.3.1.1.15 |
| pdug5GroupCurrentThUpperWarning Upper warning threshold. Units are 0.01 amps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.3.1.1.16 |
| pdug5GroupCurrentThUpperCritical Upper critical threshold. Units are 0.01 amps. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.3.1.1.17 |
| pdug5GroupCurrentPercentLoad Current percent load, based on the rated current capacity. Units are
percentage, for example 80% will be returned as 80. A negative
value indicates that this object is not avail… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.3.1.1.18 |
| pdug5GroupPowerVA A group VA value. Units are VA. A negative value indicates
that this object is not available. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.3.1.1.19 |
| pdug5GroupName A descriptive name for the group. | column | OctetString | .1.3.6.1.4.1.19536.10.1.3.1.1.2 |
| pdug5GroupPowerWatts A group power value. Units are Watts. A negative value indicates
that this object is not available. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.3.1.1.20 |
| pdug5GroupPowerWattHour A Watt-Hour value for each section. Units are WH. This value can be reset to 0
using GUI. In that case, the pdug5GroupPowerWattHourTimer will be reset as well.
A negative value i… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.3.1.1.21 |
| pdug5GroupPowerWattHourTimer Timestamp of when group Watt-hours (groupWh) was last reset. | column | OctetString | .1.3.6.1.4.1.19536.10.1.3.1.1.22 |
| pdug5GroupPowerFactor A group PF value. Units are in hundredths, for example a power factor
of 0.95 would be returned as 95, and 0.92 would be returned as 92.
A negative value indicates that this obje… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.3.1.1.23 |
| pdug5GroupPowerVAR A group VAR value. Units are VAR. A negative value indicates
that this object is not available. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.3.1.1.24 |
| pdug5GroupOutletCount The number of outlets in each group (breaker). | column | Integer32 | .1.3.6.1.4.1.19536.10.1.3.1.1.25 |
| pdug5GroupBreakerStatus Only applicable to groups with breaker. Indicates whether a breaker is turned
off or on. | column | Enumeration | .1.3.6.1.4.1.19536.10.1.3.1.1.26 |
| pdug5GroupVoltageThCtrl Circuit Breaker voltage alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disab… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.3.1.1.27 |
| pdug5GroupCurrentThCtrl Circuit Breaker current alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disab… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.3.1.1.28 |
| pdug5GroupType The type of the group. (5) has no breaker | column | Enumeration | .1.3.6.1.4.1.19536.10.1.3.1.1.3 |
| pdug5GroupVoltageMeasType Value indicates what input voltage is being measured in this table row - single phase
voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2,
phas… | column | Enumeration | .1.3.6.1.4.1.19536.10.1.3.1.1.4 |
| pdug5GroupVoltage Units are 0.1 volts. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.3.1.1.5 |
| pdug5GroupVoltageThStatus Status of the measured group voltage relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.19536.10.1.3.1.1.6 |
| pdug5GroupVoltageThLowerWarning Lower warning threshold. Units are 0.1 volts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.3.1.1.7 |
| pdug5GroupVoltageThLowerCritical Lower critical threshold. Units are 0.1 volts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.3.1.1.8 |
| pdug5GroupVoltageThUpperWarning Upper warning threshold. Units are 0.1 volts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.3.1.1.9 |