pdug5OutletCurrentRating
PANDUIT-MIB ·
.1.3.6.1.4.1.19536.10.1.5.1.1.4
Object
column
SNMPv2-SMIInteger32
Rated current capacity of this outlet. Units are 0.01 amps. A negative value indicates that the hardware current capacity is unknown.
Context
- MIB
- PANDUIT-MIB
- OID
.1.3.6.1.4.1.19536.10.1.5.1.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pdug5OutletEntry
- Table
- pdug5OutletTable
- Siblings
- 20
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pdug5OutletIndex Index for each outlet, value from 1 to the number of outlets per PDU. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.5.1.1.1 |
| pdug5OutletActivePowerThUpperCritical Upper critical threshold. Units are Watts(W). A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.5.1.1.10 |
| pdug5OutletCurrentPercentLoad Current percent load, based on the rated current capacity. Units are
percentage, for example 80% will be returned as 80. A negative
value indicates that this object is not avail… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.5.1.1.11 |
| pdug5OutletVA A outlet VA value. Units are VA. A negative value indicates
that this object is not available. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.5.1.1.12 |
| pdug5OutletWatts A outlet Watts value. Units are Watts. A negative value indicates
that this object is not available. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.5.1.1.13 |
| pdug5OutletWh A Watt-Hour value for each outlet. Units are WH.
This object is writable so that it can be reset to 0. When it is
written to, the pdug5OutletWhTimer will be reset updated as wel… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.5.1.1.14 |
| pdug5OutletWhTimer Timestamp (date and time) of outlet Watt-hours was last reset. | column | OctetString | .1.3.6.1.4.1.19536.10.1.5.1.1.15 |
| pdug5OutletPowerFactor An outlet PF value. Units are in hundredths, for example a power factor
of 0.95 would be returned as 95, and 0.92 would be returned
as 92. A negative value indicates that this o… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.5.1.1.16 |
| pdug5OutletVAR An outlet VAR value. Units are VAR. A negative value indicates
that this object is not available. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.5.1.1.17 |
| pdug5OutletBranch The branch number outlet located. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.5.1.1.18 |
| pdug5OutletActivePowerThResetThld The Reset threshold is the number of watss the reading needs to fall below
the threshold setting for the condition to be cleared. Units are watts. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.5.1.1.19 |
| pdug5OutletName A descriptive name for the outlet. | column | OctetString | .1.3.6.1.4.1.19536.10.1.5.1.1.2 |
| pdug5OutletActivePowerThChangeDelay The number of consecutive sample that the condition is present before
an alarm is raised. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.5.1.1.20 |
| pdug5OutletActivePowerThCtrl Outlet Active Power alarm threshold control:
bit 0: up critical alarm control bit, 0 - enable, 1 - disable
bit 1: up warning alarm control bit, 0 - enable, 1 - disable
b… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.5.1.1.21 |
| pdug5OutletType Type of this outlet - C13, C19, 5-20R, iecC13/C15 COMBO, iecC13/C15/C19 COMBO... | column | Enumeration | .1.3.6.1.4.1.19536.10.1.5.1.1.3 |
| pdug5OutletCurrent A outlet current measurement value. Units are 0.01 amps. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.5.1.1.5 |
| pdug5OutletActivePowerThStatus Status of the measured outlet active power relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.19536.10.1.5.1.1.6 |
| pdug5OutletActivePowerThLowerWarning Lower warning threshold. Units are Watts(W). A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.5.1.1.7 |
| pdug5OutletActivePowerThLowerCritical Lower critical threshold. Units are Watts(W). A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.5.1.1.8 |
| pdug5OutletActivePowerThUpperWarning Upper warning threshold. Units are Watts(W). A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.19536.10.1.5.1.1.9 |