pdug5InputFrequency
PANDUIT-MIB ·
.1.3.6.1.4.1.19536.10.1.2.1.1.2
Object
column
Integer32
The measured input frequency from the PDU meters in tenths of Hz.
Context
- MIB
- PANDUIT-MIB
- OID
.1.3.6.1.4.1.19536.10.1.2.1.1.2- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pdug5InputEntry
- Table
- pdug5InputTable
- Siblings
- 10
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pdug5InputType Type of input - single phase, split phase, three phase delta, or three
phase wye. | column | Enumeration | .1.3.6.1.4.1.19536.10.1.2.1.1.1 |
| pdug5InputPowerVAR An input VAR value. Units are VAR. A negative value indicates
that this object is not available. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.2.1.1.10 |
| pdug5InputTotalCurrent All phases total current value. Units are 0.01 amps.
For 3 phase, mathematically add totally 3 phase current together. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.2.1.1.11 |
| pdug5InputFrequencyStatus Status of the measured input frequency relative to the nominal frequency and the admitted tolerance. | column | Enumeration | .1.3.6.1.4.1.19536.10.1.2.1.1.3 |
| pdug5InputPowerVA A total input VA of all phases. Units are VA. A negative value indicates
that this object is not available. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.2.1.1.4 |
| pdug5InputPowerWatts A total input Watts of all phases. Units are Watts. A negative value indicates
that this object is not available. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.2.1.1.5 |
| pdug5InputTotalEnergy A total input Watt-Hour value for all phases. Units are KWh. This value is accumulated since PDU in service.
A negative value indicates that this object is not available. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.2.1.1.6 |
| pdug5InputPowerWattHourTimer A Timestamp of when the Total Input WH was last reset. | column | OctetString | .1.3.6.1.4.1.19536.10.1.2.1.1.7 |
| pdug5InputResettableEnergy A total input Watt-Hour value for all phases. Units are Wh. This value can be reset to 0
using GUI. In that case, the pdug5InputPowerWattHourTimer will be reset as well
A negativ… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.2.1.1.8 |
| pdug5InputPowerFactor An input PF value. Units are in hundredths, for example a power factor
of 0.95 would be returned as 95, and 0.92 would be returned as 92.
A negative value indicates that this obj… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.19536.10.1.2.1.1.9 |