ENERGY-OBJECT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
33
.1.3.6.1.2.1.229.1.1 · 1 row entry · 1 columns
This table is useful for helping applications determine
the monitoring capabilities supported by the local
management agents.  It is possible for applications to
know which tables are usable without going through a
trial-and-error process.
eoMeterCapabilitiesEntry entry .1.3.6.1.2.1.229.1.1.1
An entry describes the metering capability of an Energy
Object.
Indexes
ENTITY-MIBentPhysicalIndex
Column Syntax OID
eoMeterCapability
An indication of the energy-monitoring capabilities
supported by this agent. This object use a BITS syntax
and indicates the MIB groups supported by the probe. By
reading the value of this object, it is possible to
de…
Bits
Enumerated Values:
0none
1powermetering
2energymetering
3powerattributes
.1.3.6.1.2.1.229.1.1.1.1
.1.3.6.1.2.1.229.1.2 · 1 row entry · 10 columns
This table lists Energy Objects.
eoPowerEntry entry .1.3.6.1.2.1.229.1.2.1
An entry describes the power usage of an Energy Object.
Indexes
ENTITY-MIBentPhysicalIndex
Column Syntax OID
eoPower
This object indicates the power measured for the Energy
Object. For alternating current, this value is obtained
as an average over fixed number of AC cycles. This value
is specified in SI units of watts with the magni…
wattsSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.2.1.229.1.2.1.1
eoPowerNameplate
This object indicates the rated maximum consumption for
the fully populated Energy Object. The nameplate power
requirements are the maximum power numbers given in SI
watts and, in almost all cases, are well above the
e…
wattsSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.2.1.2
eoPowerUnitMultiplier
The magnitude of watts for the usage value in eoPower
and eoPowerNameplate.
UnitMultiplier
Textual Convention: UnitMultiplier Enumeration
Type Values:
-24yocto
-21zepto
-18atto
-15femto
-12pico
-9nano
-6micro
-3milli
0units
3kilo
6mega
9giga
12tera
15peta
18exa
21zetta
24yotta
.1.3.6.1.2.1.229.1.2.1.3
eoPowerAccuracy
This object indicates a percentage value, in hundredths of a
percent, representing the assumed accuracy of the usage
reported by eoPower. For example, the value 1010 means
the reported usage is accurate to +/- 10.1 per…
hundredths of percentInteger32
Constraints:
range: 0-10000
.1.3.6.1.2.1.229.1.2.1.4
eoPowerMeasurementCaliber
This object specifies how the usage value reported by
eoPower was obtained:

- unavailable(1): Indicates that the usage is not
available. In such a case, the eoPower value must be 0
for devices that canno…
Enumeration
Enumerated Values:
1unavailable
2unknown
3actual
4estimated
5static
.1.3.6.1.2.1.229.1.2.1.5
eoPowerCurrentType
This object indicates whether the eoPower for the
Energy Object reports alternating current 'ac', direct
current 'dc', or that the current type is unknown.
Enumeration
Enumerated Values:
1ac
2dc
3unknown
.1.3.6.1.2.1.229.1.2.1.6
eoPowerMeasurementLocal
This object indicates the source of power measurement
and can be useful when modeling the power usage of

attached devices. The power measurement can be performed
by the entity itself or the power measure…
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.2.1.229.1.2.1.7
eoPowerAdminState
This object specifies the desired Power State and the
Power State Set for the Energy Object. Note that other(0)
is not a Power State Set and unknown(255) is not a Power
State as such, but simply an indication that the …
IANAPowerStateSet-MIBPowerStateSetr/w
Textual Convention: IANAPowerStateSet-MIBPowerStateSet Enumeration
Type Values:
0other
255unknown
256ieee1621
257ieee1621Off
258ieee1621Sleep
259ieee1621On
512dmtf
513dmtfOn
514dmtfSleepLight
515dmtfSleepDeep
516dmtfOffHard
517dmtfOffSoft
518dmtfHibernate
519dmtfPowerOffSoft
520dmtfPowerOffHard
521dmtfMasterBusReset
522dmtfDiagnosticInterrapt
523dmtfOffSoftGraceful
524dmtfOffHardGraceful
525dmtfMasterBusResetGraceful
526dmtfPowerCycleOffSoftGraceful
527dmtfPowerCycleHardGraceful
1024eman
1025emanMechOff
1026emanSoftOff
1027emanHibernate
1028emanSleep
1029emanStandby
1030emanReady
1031emanLowMinus
1032emanLow
1033emanMediumMinus
1034emanMedium
1035emanHighMinus
1036emanHigh
.1.3.6.1.2.1.229.1.2.1.8
eoPowerOperState
This object specifies the current operational Power
State and the Power State Set for the Energy Object.
other(0) is not a Power State Set and unknown(255) is not
a Power State as such, but simply an indication that the…
IANAPowerStateSet-MIBPowerStateSet
Textual Convention: IANAPowerStateSet-MIBPowerStateSet Enumeration
Type Values:
0other
255unknown
256ieee1621
257ieee1621Off
258ieee1621Sleep
259ieee1621On
512dmtf
513dmtfOn
514dmtfSleepLight
515dmtfSleepDeep
516dmtfOffHard
517dmtfOffSoft
518dmtfHibernate
519dmtfPowerOffSoft
520dmtfPowerOffHard
521dmtfMasterBusReset
522dmtfDiagnosticInterrapt
523dmtfOffSoftGraceful
524dmtfOffHardGraceful
525dmtfMasterBusResetGraceful
526dmtfPowerCycleOffSoftGraceful
527dmtfPowerCycleHardGraceful
1024eman
1025emanMechOff
1026emanSoftOff
1027emanHibernate
1028emanSleep
1029emanStandby
1030emanReady
1031emanLowMinus
1032emanLow
1033emanMediumMinus
1034emanMedium
1035emanHighMinus
1036emanHigh
.1.3.6.1.2.1.229.1.2.1.9
eoPowerStateEnterReason
This string object describes the reason for the

eoPowerAdminState transition. Alternatively, this string
may contain with the entity that configured this Energy
Object to this Power State.
RMON-MIBOwnerStringr/w
Textual Convention: RMON-MIBOwnerString OctetString
Type Constraints:
range: 0..127
.1.3.6.1.2.1.229.1.2.1.10
.1.3.6.1.2.1.229.1.3 · 1 row entry · 5 columns
This table enumerates the maximum power usage, in watts,
for every single supported Power State of each Energy
Object.
          
This table has cross-reference with the eoPowerTable,
containing rows describing each Power State for the
corresponding Energy Object.  For every Energy Object in
the eoPowerTable, there is a corresponding entry in this
table.
eoPowerStateEntry entry .1.3.6.1.2.1.229.1.3.1
A eoPowerStateEntry extends a corresponding
eoPowerEntry. This entry displays max usage values at
every single possible Power State supported by the Energy
Object.
For example, given the values of a Energy Object
corre…
Indexes
ENTITY-MIBentPhysicalIndex eoPowerStateIndex
Column Syntax OID
eoPowerStateIndex
This object specifies the index of the Power State of
the Energy Object within a Power State Set. The semantics
of the specific Power State can be obtained from the
Power State Set definition.
IANAPowerStateSet-MIBPowerStateSet
Textual Convention: IANAPowerStateSet-MIBPowerStateSet Enumeration
Type Values:
0other
255unknown
256ieee1621
257ieee1621Off
258ieee1621Sleep
259ieee1621On
512dmtf
513dmtfOn
514dmtfSleepLight
515dmtfSleepDeep
516dmtfOffHard
517dmtfOffSoft
518dmtfHibernate
519dmtfPowerOffSoft
520dmtfPowerOffHard
521dmtfMasterBusReset
522dmtfDiagnosticInterrapt
523dmtfOffSoftGraceful
524dmtfOffHardGraceful
525dmtfMasterBusResetGraceful
526dmtfPowerCycleOffSoftGraceful
527dmtfPowerCycleHardGraceful
1024eman
1025emanMechOff
1026emanSoftOff
1027emanHibernate
1028emanSleep
1029emanStandby
1030emanReady
1031emanLowMinus
1032emanLow
1033emanMediumMinus
1034emanMedium
1035emanHighMinus
1036emanHigh
.1.3.6.1.2.1.229.1.3.1.1
eoPowerStateMaxPower
This object indicates the maximum power for the Energy
Object at the particular Power State. This value is
specified in SI units of watts with the magnitude of the
units (milliwatts, kilowatts, etc.) indicated separate…
wattsSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.2.1.229.1.3.1.2
eoPowerStatePowerUnitMultiplier
The magnitude of watts for the usage value in
eoPowerStateMaxPower.
UnitMultiplier
Textual Convention: UnitMultiplier Enumeration
Type Values:
-24yocto
-21zepto
-18atto
-15femto
-12pico
-9nano
-6micro
-3milli
0units
3kilo
6mega
9giga
12tera
15peta
18exa
21zetta
24yotta
.1.3.6.1.2.1.229.1.3.1.3
eoPowerStateTotalTime
This object indicates the total time in hundredths
of a second that the Energy Object has been in this power
state since the last reset, as specified in the
sysUpTime.
SNMPv2-SMITimeTicks
Textual Convention: SNMPv2-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.3.1.4
eoPowerStateEnterCount
This object indicates how often the Energy Object has
entered this power state, since the last reset of the
device as specified in the sysUpTime.
SNMPv2-SMICounter32
Textual Convention: SNMPv2-SMICounter32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.3.1.5
.1.3.6.1.2.1.229.1.4 · 1 row entry · 8 columns
This table is used to configure the parameters for
energy measurement collection in the table eoEnergyTable.
This table allows the configuration of different
measurement settings on the same Energy Object.
Implementation of this table only makes sense for Energy
Objects that an eoPowerMeasurementCaliber of actual.
eoEnergyParametersEntry entry .1.3.6.1.2.1.229.1.4.1
An entry controls an energy measurement in
eoEnergyTable.
Indexes
ENTITY-MIBentPhysicalIndex eoEnergyParametersIndex
Column Syntax OID
eoEnergyParametersIndex
This object specifies the index of the Energy Parameters
setting for collection of energy measurements for an
Energy Object. An Energy Object can have multiple
eoEnergyParametersIndex, depending on the capabilities of
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.2.1.229.1.4.1.2
eoEnergyParametersIntervalLength
This object indicates the length of time in hundredths
of a second over which to compute the average
eoEnergyConsumed measurement in the eoEnergyTable table.
The computation is based on the Energy Object's internal
samp…
SNMPv2-TCTimeIntervalr/w
Textual Convention: SNMPv2-TCTimeInterval Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.229.1.4.1.3
eoEnergyParametersIntervalNumber
The number of intervals maintained in the eoEnergyTable.
Each interval is characterized by a specific
eoEnergyCollectionStartTime, used as an index to the
table eoEnergyTable. Whenever the maximum number of
entries is …
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.4.1.4
eoEnergyParametersIntervalMode
A control object to define the mode of interval
calculation for the computation of the average
eoEnergyConsumed or eoEnergyProvided measurement in the
eoEnergyTable table.

A mode of period(1) specifies no…
Enumerationr/w
Enumerated Values:
1period
2sliding
3total
.1.3.6.1.2.1.229.1.4.1.5
eoEnergyParametersIntervalWindow
The length of the duration window between the starting
time of one sliding window and the next starting time in
hundredths of seconds, used to compute the average of
eoEnergyConsumed, eoEnergyProvided measurements in th…
SNMPv2-TCTimeIntervalr/w
Textual Convention: SNMPv2-TCTimeInterval Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.2.1.229.1.4.1.6
eoEnergyParametersSampleRate
The sampling rate, in milliseconds, at which the Energy
Object should poll power usage in order to compute the
average eoEnergyConsumed, eoEnergyProvided measurements
in the table eoEnergyTable. The Energy Object shoul…
MillisecondsSNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.4.1.7
eoEnergyParametersStorageType
This variable indicates the storage type for this row.
SNMPv2-TCStorageTyper/w
Textual Convention: SNMPv2-TCStorageType Enumeration
Type Values:
1other
2volatile
3nonVolatile
4permanent
5readOnly
.1.3.6.1.2.1.229.1.4.1.8
eoEnergyParametersStatus
The status of this row. The eoEnergyParametersStatus is
used to start or stop energy usage logging. An entry
status may not be active(1) unless all objects in the
entry have an appropriate value. If this object is no…
SNMPv2-TCRowStatusr/w
Textual Convention: SNMPv2-TCRowStatus Enumeration
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
.1.3.6.1.2.1.229.1.4.1.9
.1.3.6.1.2.1.229.1.5 · 1 row entry · 9 columns
This table lists Energy Object energy measurements.
Entries in this table are only created if the
corresponding value of object eoPowerMeasurementCaliber
is active(3), i.e., if the power is actually metered.
eoEnergyEntry entry .1.3.6.1.2.1.229.1.5.1
An entry describing energy measurements.
Indexes
eoEnergyParametersIndex eoEnergyCollectionStartTime
Column Syntax OID
eoEnergyCollectionStartTime
The time (in hundredths of a second) since the
network management portion of the system was last
re-initialized, as specified in the sysUpTime RFC 3418.
This object specifies the start time of the energy
measurement sam…
hundredths of a secondSNMPv2-SMITimeTicks
Textual Convention: SNMPv2-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.1
eoEnergyConsumed
This object indicates the energy consumed in units of
watt-hours for the Energy Object over the defined
interval. This value is specified in the common billing
units of watt-hours with the magnitude of watt-hours
kWh, …
Watt-hoursSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.2
eoEnergyProvided
This object indicates the energy produced in units of
watt-hours for the Energy Object over the defined
interval.

This value is specified in the common billing units of
watt-hours with the magnitude of wa…
Watt-hoursSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.3
eoEnergyStored
This object indicates the difference of the energy
consumed and energy produced for an Energy Object in
units of watt-hours for the Energy Object over the
defined interval. This value is specified in the common
billing…
Watt-hoursSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.4
eoEnergyUnitMultiplier
This object is the magnitude of watt-hours for the
energy field in eoEnergyConsumed, eoEnergyProvided,
eoEnergyStored, eoEnergyMaxConsumed, and
eoEnergyMaxProduced.
UnitMultiplier
Textual Convention: UnitMultiplier Enumeration
Type Values:
-24yocto
-21zepto
-18atto
-15femto
-12pico
-9nano
-6micro
-3milli
0units
3kilo
6mega
9giga
12tera
15peta
18exa
21zetta
24yotta
.1.3.6.1.2.1.229.1.5.1.5
eoEnergyAccuracy
This object indicates a percentage accuracy, in hundredths
of a percent, of Energy usage reporting. eoEnergyAccuracy
is applicable to all Energy measurements in the
eoEnergyTable.

For example, 1010 means…
hundredths of percentInteger32
Constraints:
range: 0-10000
.1.3.6.1.2.1.229.1.5.1.6
eoEnergyMaxConsumed
This object is the maximum energy observed in
eoEnergyConsumed since the monitoring started or was
reinitialized. This value is specified in the common
billing units of watt-hours with the magnitude of
watt-hours (kWh,…
Watt-hoursSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.7
eoEnergyMaxProduced
This object is the maximum energy ever observed in
eoEnergyEnergyProduced since the monitoring started. This
value is specified in the units of watt-hours with the
magnitude of watt-hours (kWh, MWh, etc.) indicated
sep…
Watt-hoursSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.229.1.5.1.8
eoEnergyDiscontinuityTime
The value of sysUpTime RFC 3418 on the most recent
occasion at which any one or more of this entity's energy
counters in this table suffered a discontinuity:
eoEnergyConsumed, eoEnergyProvided or eoEnergyStored. If
no …
SNMPv2-TCTimeStamp
Textual Convention: SNMPv2-TCTimeStamp Unsigned32
.1.3.6.1.2.1.229.1.5.1.9