eoPowerAccuracy
ENERGY-OBJECT-MIB ·
.1.3.6.1.2.1.229.1.2.1.4
Object
column
hundredths of percent Integer32
This object indicates a percentage value, in hundredths of a
percent, representing the assumed accuracy of the usage
reported by eoPower. For example, the value 1010 means
the reported usage is accurate to +/- 10.1 percent. This
value is zero if the accuracy is unknown or not
applicable based upon the measurement method.
ANSI and IEC define the following accuracy classes for
power measurement:
IEC 62053-22 60044-1 class 0.1, 0.2, 0.5, 1 3.
ANSI C12.20 class 0.2, 0.5
Context
- MIB
- ENERGY-OBJECT-MIB
- OID
.1.3.6.1.2.1.229.1.2.1.4- Type
- column
- Access
- readonly
- Status
- current
- Units
- hundredths of percent
- Parent
- eoPowerEntry
- Table
- eoPowerTable
- Siblings
- 9
Syntax
hundredths of percent Integer32
Values & Constraints
Object Constraints
range: 0-10000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eoPower This object indicates the power measured for the Energy
Object. For alternating current, this value is obtained
as an average over fixed number of AC cycles. This value
is speci… | column | watts SNMPv2-SMIInteger32 | .1.3.6.1.2.1.229.1.2.1.1 |
| eoPowerStateEnterReason This string object describes the reason for the
eoPowerAdminState transition. Alternatively, this string
may contain with the entity that configured this Energy
Ob… | column | RMON-MIBOwnerString | .1.3.6.1.2.1.229.1.2.1.10 |
| eoPowerNameplate This object indicates the rated maximum consumption for
the fully populated Energy Object. The nameplate power
requirements are the maximum power numbers given in SI
watts and, i… | column | watts SNMPv2-SMIUnsigned32 | .1.3.6.1.2.1.229.1.2.1.2 |
| eoPowerUnitMultiplier The magnitude of watts for the usage value in eoPower
and eoPowerNameplate. | column | UnitMultiplier | .1.3.6.1.2.1.229.1.2.1.3 |
| eoPowerMeasurementCaliber This object specifies how the usage value reported by
eoPower was obtained:
- unavailable(1): Indicates that the usage is not
available. In such a case, the eoPowe… | column | Enumeration | .1.3.6.1.2.1.229.1.2.1.5 |
| eoPowerCurrentType This object indicates whether the eoPower for the
Energy Object reports alternating current 'ac', direct
current 'dc', or that the current type is unknown. | column | Enumeration | .1.3.6.1.2.1.229.1.2.1.6 |
| eoPowerMeasurementLocal This object indicates the source of power measurement
and can be useful when modeling the power usage of
attached devices. The power measurement can be performed
b… | column | SNMPv2-TCTruthValue | .1.3.6.1.2.1.229.1.2.1.7 |
| eoPowerAdminState This object specifies the desired Power State and the
Power State Set for the Energy Object. Note that other(0)
is not a Power State Set and unknown(255) is not a Power
State as … | column | IANAPowerStateSet-MIBPowerStateSet | .1.3.6.1.2.1.229.1.2.1.8 |
| eoPowerOperState This object specifies the current operational Power
State and the Power State Set for the Energy Object.
other(0) is not a Power State Set and unknown(255) is not
a Power State as… | column | IANAPowerStateSet-MIBPowerStateSet | .1.3.6.1.2.1.229.1.2.1.9 |