eoEnergyParametersIntervalNumber
ENERGY-OBJECT-MIB ·
.1.3.6.1.2.1.229.1.4.1.4
Object
The number of intervals maintained in the eoEnergyTable. Each interval is characterized by a specific eoEnergyCollectionStartTime, used as an index to the table eoEnergyTable. Whenever the maximum number of entries is reached, the measurement over the new interval replaces the oldest measurement. There is one exception to this rule: when the eoEnergyMaxConsumed and/or eoEnergyMaxProduced are in (one of) the two oldest measurement(s), they are left untouched and the next oldest measurement is replaced.
Context
- MIB
- ENERGY-OBJECT-MIB
- OID
.1.3.6.1.2.1.229.1.4.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- eoEnergyParametersEntry
- Table
- eoEnergyParametersTable
- Siblings
- 7
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eoEnergyParametersIndex This object specifies the index of the Energy Parameters
setting for collection of energy measurements for an
Energy Object. An Energy Object can have multiple
eoEnergyParameters… | column | Integer32 | .1.3.6.1.2.1.229.1.4.1.2 |
| eoEnergyParametersIntervalLength This object indicates the length of time in hundredths
of a second over which to compute the average
eoEnergyConsumed measurement in the eoEnergyTable table.
The computation is ba… | column | SNMPv2-TCTimeInterval | .1.3.6.1.2.1.229.1.4.1.3 |
| eoEnergyParametersIntervalMode A control object to define the mode of interval
calculation for the computation of the average
eoEnergyConsumed or eoEnergyProvided measurement in the
eoEnergyTable table.
… | column | Enumeration | .1.3.6.1.2.1.229.1.4.1.5 |
| eoEnergyParametersIntervalWindow The length of the duration window between the starting
time of one sliding window and the next starting time in
hundredths of seconds, used to compute the average of
eoEnergyConsu… | column | SNMPv2-TCTimeInterval | .1.3.6.1.2.1.229.1.4.1.6 |
| eoEnergyParametersSampleRate The sampling rate, in milliseconds, at which the Energy
Object should poll power usage in order to compute the
average eoEnergyConsumed, eoEnergyProvided measurements
in the table… | column | Milliseconds SNMPv2-SMIUnsigned32 | .1.3.6.1.2.1.229.1.4.1.7 |
| eoEnergyParametersStorageType This variable indicates the storage type for this row. | column | SNMPv2-TCStorageType | .1.3.6.1.2.1.229.1.4.1.8 |
| eoEnergyParametersStatus The status of this row. The eoEnergyParametersStatus is
used to start or stop energy usage logging. An entry
status may not be active(1) unless all objects in the
entry have an … | column | SNMPv2-TCRowStatus | .1.3.6.1.2.1.229.1.4.1.9 |