eoEnergyParametersIntervalLength
ENERGY-OBJECT-MIB ·
.1.3.6.1.2.1.229.1.4.1.3
Object
This object indicates the length of time in hundredths of a second over which to compute the average eoEnergyConsumed measurement in the eoEnergyTable table. The computation is based on the Energy Object's internal sampling rate of power consumed or produced by the Energy Object. The sampling rate is the rate at which the Energy Object can read the power usage and may differ based on device capabilities. The average energy consumption is then computed over the length of the interval. The default value of 15 minutes is a common interval used in industry.
Context
- MIB
- ENERGY-OBJECT-MIB
- OID
.1.3.6.1.2.1.229.1.4.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- eoEnergyParametersEntry
- Table
- eoEnergyParametersTable
- Siblings
- 7
Values & Constraints
Type Constraints
range: 0..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eoEnergyParametersIndex This object specifies the index of the Energy Parameters
setting for collection of energy measurements for an
Energy Object. An Energy Object can have multiple
eoEnergyParameters… | column | Integer32 | .1.3.6.1.2.1.229.1.4.1.2 |
| eoEnergyParametersIntervalNumber The number of intervals maintained in the eoEnergyTable.
Each interval is characterized by a specific
eoEnergyCollectionStartTime, used as an index to the
table eoEnergyTable. Wh… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.2.1.229.1.4.1.4 |
| eoEnergyParametersIntervalMode A control object to define the mode of interval
calculation for the computation of the average
eoEnergyConsumed or eoEnergyProvided measurement in the
eoEnergyTable table.
… | column | Enumeration | .1.3.6.1.2.1.229.1.4.1.5 |
| eoEnergyParametersIntervalWindow The length of the duration window between the starting
time of one sliding window and the next starting time in
hundredths of seconds, used to compute the average of
eoEnergyConsu… | column | SNMPv2-TCTimeInterval | .1.3.6.1.2.1.229.1.4.1.6 |
| eoEnergyParametersSampleRate The sampling rate, in milliseconds, at which the Energy
Object should poll power usage in order to compute the
average eoEnergyConsumed, eoEnergyProvided measurements
in the table… | column | Milliseconds SNMPv2-SMIUnsigned32 | .1.3.6.1.2.1.229.1.4.1.7 |
| eoEnergyParametersStorageType This variable indicates the storage type for this row. | column | SNMPv2-TCStorageType | .1.3.6.1.2.1.229.1.4.1.8 |
| eoEnergyParametersStatus The status of this row. The eoEnergyParametersStatus is
used to start or stop energy usage logging. An entry
status may not be active(1) unless all objects in the
entry have an … | column | SNMPv2-TCRowStatus | .1.3.6.1.2.1.229.1.4.1.9 |