eoEnergyParametersSampleRate
ENERGY-OBJECT-MIB ·
.1.3.6.1.2.1.229.1.4.1.7
Object
The sampling rate, in milliseconds, at which the Energy Object should poll power usage in order to compute the average eoEnergyConsumed, eoEnergyProvided measurements in the table eoEnergyTable. The Energy Object should initially set this sampling rate to a reasonable value, i.e., a compromise between intervals that will provide good accuracy by not being too long, but not so short that they affect the Energy Object performance by requesting continuous polling. If the sampling rate is unknown, the value 0 is reported. The sampling rate should be selected so that eoEnergyParametersIntervalWindow is a multiple of eoEnergyParametersSampleRate. The default value is one second.
Context
- MIB
- ENERGY-OBJECT-MIB
- OID
.1.3.6.1.2.1.229.1.4.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Units
- Milliseconds
- Parent
- eoEnergyParametersEntry
- Table
- eoEnergyParametersTable
- Siblings
- 7
Syntax
Milliseconds SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eoEnergyParametersIndex This object specifies the index of the Energy Parameters
setting for collection of energy measurements for an
Energy Object. An Energy Object can have multiple
eoEnergyParameters… | column | Integer32 | .1.3.6.1.2.1.229.1.4.1.2 |
| eoEnergyParametersIntervalLength This object indicates the length of time in hundredths
of a second over which to compute the average
eoEnergyConsumed measurement in the eoEnergyTable table.
The computation is ba… | column | SNMPv2-TCTimeInterval | .1.3.6.1.2.1.229.1.4.1.3 |
| eoEnergyParametersIntervalNumber The number of intervals maintained in the eoEnergyTable.
Each interval is characterized by a specific
eoEnergyCollectionStartTime, used as an index to the
table eoEnergyTable. Wh… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.2.1.229.1.4.1.4 |
| eoEnergyParametersIntervalMode A control object to define the mode of interval
calculation for the computation of the average
eoEnergyConsumed or eoEnergyProvided measurement in the
eoEnergyTable table.
… | column | Enumeration | .1.3.6.1.2.1.229.1.4.1.5 |
| eoEnergyParametersIntervalWindow The length of the duration window between the starting
time of one sliding window and the next starting time in
hundredths of seconds, used to compute the average of
eoEnergyConsu… | column | SNMPv2-TCTimeInterval | .1.3.6.1.2.1.229.1.4.1.6 |
| eoEnergyParametersStorageType This variable indicates the storage type for this row. | column | SNMPv2-TCStorageType | .1.3.6.1.2.1.229.1.4.1.8 |
| eoEnergyParametersStatus The status of this row. The eoEnergyParametersStatus is
used to start or stop energy usage logging. An entry
status may not be active(1) unless all objects in the
entry have an … | column | SNMPv2-TCRowStatus | .1.3.6.1.2.1.229.1.4.1.9 |