eoEnergyCollectionStartTime
ENERGY-OBJECT-MIB ·
.1.3.6.1.2.1.229.1.5.1.1
Object
The time (in hundredths of a second) since the network management portion of the system was last re-initialized, as specified in the sysUpTime RFC 3418. This object specifies the start time of the energy measurement sample.
Context
- MIB
- ENERGY-OBJECT-MIB
- OID
.1.3.6.1.2.1.229.1.5.1.1- Type
- column
- Access
- noaccess
- Status
- current
- Units
- hundredths of a second
- Parent
- eoEnergyEntry
- Table
- eoEnergyTable
- Siblings
- 8
Syntax
hundredths of a second SNMPv2-SMITimeTicks
- Source
- SNMPv2-SMITimeTicks
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eoEnergyConsumed This object indicates the energy consumed in units of
watt-hours for the Energy Object over the defined
interval. This value is specified in the common billing
units of watt-hour… | column | Watt-hours SNMPv2-SMIUnsigned32 | .1.3.6.1.2.1.229.1.5.1.2 |
| eoEnergyProvided This object indicates the energy produced in units of
watt-hours for the Energy Object over the defined
interval.
This value is specified in the common billing unit… | column | Watt-hours SNMPv2-SMIUnsigned32 | .1.3.6.1.2.1.229.1.5.1.3 |
| eoEnergyStored This object indicates the difference of the energy
consumed and energy produced for an Energy Object in
units of watt-hours for the Energy Object over the
defined interval. This … | column | Watt-hours SNMPv2-SMIUnsigned32 | .1.3.6.1.2.1.229.1.5.1.4 |
| eoEnergyUnitMultiplier This object is the magnitude of watt-hours for the
energy field in eoEnergyConsumed, eoEnergyProvided,
eoEnergyStored, eoEnergyMaxConsumed, and
eoEnergyMaxProduced. | column | UnitMultiplier | .1.3.6.1.2.1.229.1.5.1.5 |
| eoEnergyAccuracy This object indicates a percentage accuracy, in hundredths
of a percent, of Energy usage reporting. eoEnergyAccuracy
is applicable to all Energy measurements in the
eoEnergyTable… | column | hundredths of percent Integer32 | .1.3.6.1.2.1.229.1.5.1.6 |
| eoEnergyMaxConsumed This object is the maximum energy observed in
eoEnergyConsumed since the monitoring started or was
reinitialized. This value is specified in the common
billing units of watt-hour… | column | Watt-hours SNMPv2-SMIUnsigned32 | .1.3.6.1.2.1.229.1.5.1.7 |
| eoEnergyMaxProduced This object is the maximum energy ever observed in
eoEnergyEnergyProduced since the monitoring started. This
value is specified in the units of watt-hours with the
magnitude of w… | column | Watt-hours SNMPv2-SMIUnsigned32 | .1.3.6.1.2.1.229.1.5.1.8 |
| eoEnergyDiscontinuityTime The value of sysUpTime RFC 3418 on the most recent
occasion at which any one or more of this entity's energy
counters in this table suffered a discontinuity:
eoEnergyConsumed, eoE… | column | SNMPv2-TCTimeStamp | .1.3.6.1.2.1.229.1.5.1.9 |