CPQCR-MIB

Imported Objects
CPQHOST-MIB compaq cpqHoTrapFlags
RFC-1212 OBJECT-TYPE
RFC-1215 TRAP-TYPE
RFC1155-SMI Counter enterprises Gauge
RFC1213-MIB DisplayString sysName
Objects (94)
cpqClusteredRAID .1.3.6.1.4.1.232.141
cpqCrMibRev .1.3.6.1.4.1.232.141.1
cpqCrMibRevMajor mandatory Integer32 .1.3.6.1.4.1.232.141.1.1
cpqCrMibRevMinor mandatory Integer32 .1.3.6.1.4.1.232.141.1.2
cpqCrMibCondition mandatory Enumeration .1.3.6.1.4.1.232.141.1.3
cpqCrComponent .1.3.6.1.4.1.232.141.2
cpqCrInterface .1.3.6.1.4.1.232.141.2.1
cpqCrOsCommon .1.3.6.1.4.1.232.141.2.1.4
cpqCrOsCommonPollFreq mandatory r/w Integer32 .1.3.6.1.4.1.232.141.2.1.4.1
cpqCrCntlr .1.3.6.1.4.1.232.141.2.2
cpqCrCntlrTable mandatory .1.3.6.1.4.1.232.141.2.2.1
cpqCrCntlrEntry mandatory cpqCrCntlrIndex .1.3.6.1.4.1.232.141.2.2.1.1
cpqCrCntlrIndex mandatory Integer32 .1.3.6.1.4.1.232.141.2.2.1.1.1
cpqCrCntlrRebuildRate mandatory Integer32 .1.3.6.1.4.1.232.141.2.2.1.1.10
cpqCrCntlrCreateRate mandatory Integer32 .1.3.6.1.4.1.232.141.2.2.1.1.11
cpqCrCntlrCacheSize mandatory Integer32 .1.3.6.1.4.1.232.141.2.2.1.1.12
cpqCrCntlrSimmSizeA mandatory Integer32 .1.3.6.1.4.1.232.141.2.2.1.1.13
cpqCrCntlrSimmSizeB mandatory Integer32 .1.3.6.1.4.1.232.141.2.2.1.1.14
cpqCrCntlrSerialNumber mandatory OctetString .1.3.6.1.4.1.232.141.2.2.1.1.2
cpqCrCntlrFWRev mandatory OctetString .1.3.6.1.4.1.232.141.2.2.1.1.3
cpqCrCntlrCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.2.1.1.4
cpqCrCntlrCurrentRole mandatory Enumeration .1.3.6.1.4.1.232.141.2.2.1.1.8
cpqCrCntlrDriveOwnership mandatory Enumeration .1.3.6.1.4.1.232.141.2.2.1.1.9
cpqCrLogDrv .1.3.6.1.4.1.232.141.2.3
cpqCrLogDrvTable mandatory .1.3.6.1.4.1.232.141.2.3.1
cpqCrLogDrvEntry mandatory cpqCrLogDrvCntlrIndexcpqCrLogDrvIndex .1.3.6.1.4.1.232.141.2.3.1.1
cpqCrLogDrvCntlrIndex mandatory Integer32 .1.3.6.1.4.1.232.141.2.3.1.1.1
cpqCrLogDrvCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.3.1.1.10
cpqCrLogDrvPartitionIDs mandatory OctetString .1.3.6.1.4.1.232.141.2.3.1.1.11
cpqCrLogDrvIndex mandatory Integer32 .1.3.6.1.4.1.232.141.2.3.1.1.2
cpqCrLogDrvRAIDLevel mandatory Enumeration .1.3.6.1.4.1.232.141.2.3.1.1.3
cpqCrLogDrvStatus mandatory Enumeration .1.3.6.1.4.1.232.141.2.3.1.1.4
cpqCrLogDrvRebuildPercentage mandatory Integer32 .1.3.6.1.4.1.232.141.2.3.1.1.5
cpqCrLogDrvAvailSpares mandatory OctetString .1.3.6.1.4.1.232.141.2.3.1.1.7
cpqCrLogDrvSize mandatory Integer32 .1.3.6.1.4.1.232.141.2.3.1.1.8
cpqCrLogDrvPhyDrvIDs mandatory OctetString .1.3.6.1.4.1.232.141.2.3.1.1.9
cpqCrSpareDrv .1.3.6.1.4.1.232.141.2.4
cpqCrSpareTable mandatory .1.3.6.1.4.1.232.141.2.4.1
cpqCrSpareEntry mandatory cpqCrSpareCntlrIndexcpqCrSparePhyDrvIndex .1.3.6.1.4.1.232.141.2.4.1.1
cpqCrSpareCntlrIndex mandatory Integer32 .1.3.6.1.4.1.232.141.2.4.1.1.1
cpqCrSparePhyDrvIndex mandatory Integer32 .1.3.6.1.4.1.232.141.2.4.1.1.2
cpqCrSpareStatus mandatory Enumeration .1.3.6.1.4.1.232.141.2.4.1.1.3
cpqCrSpareCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.4.1.1.4
cpqCrSpareScsiID mandatory Integer32 .1.3.6.1.4.1.232.141.2.4.1.1.5
cpqCrPhyDrv .1.3.6.1.4.1.232.141.2.5
cpqCrPhyDrvTable mandatory .1.3.6.1.4.1.232.141.2.5.1
cpqCrPhyDrvEntry mandatory cpqCrPhyDrvCntlrIndexcpqCrPhyDrvIndex .1.3.6.1.4.1.232.141.2.5.1.1
cpqCrPhyDrvCntlrIndex mandatory Integer32 .1.3.6.1.4.1.232.141.2.5.1.1.1
cpqCrPhyDrvIndex mandatory Integer32 .1.3.6.1.4.1.232.141.2.5.1.1.2
cpqCrPhyDrvVendor mandatory OctetString .1.3.6.1.4.1.232.141.2.5.1.1.3
cpqCrPhyDrvModel mandatory OctetString .1.3.6.1.4.1.232.141.2.5.1.1.4
cpqCrPhyDrvRevision mandatory OctetString .1.3.6.1.4.1.232.141.2.5.1.1.5
cpqCrPhyDrvStatus mandatory Enumeration .1.3.6.1.4.1.232.141.2.5.1.1.6
cpqCrPhyDrvSize mandatory Integer32 .1.3.6.1.4.1.232.141.2.5.1.1.7
cpqCrPhyDrvCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.5.1.1.8
cpqCrPhyDrvScsiID mandatory Integer32 .1.3.6.1.4.1.232.141.2.5.1.1.9
cpqCrEMU .1.3.6.1.4.1.232.141.2.7
cpqCrEMUBoardTemperatureStatus obsolete Enumeration .1.3.6.1.4.1.232.141.2.7.1
cpqCrEMUTemperatureStatus mandatory Enumeration .1.3.6.1.4.1.232.141.2.7.10
cpqCrEMUTemperatureLevel mandatory Integer32 .1.3.6.1.4.1.232.141.2.7.11
cpqCrEMUTemperatureCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.7.12
cpqCrEMUEnclosureTemperatureStatus obsolete Enumeration .1.3.6.1.4.1.232.141.2.7.2
cpqCrEMUBoardTemperatureLevel obsolete Integer32 .1.3.6.1.4.1.232.141.2.7.3
cpqCrEMUEnclosureTemperatureLevel obsolete Integer32 .1.3.6.1.4.1.232.141.2.7.4
cpqCrEMUCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.7.5
cpqCrEMUFanStatus mandatory Enumeration .1.3.6.1.4.1.232.141.2.7.6
cpqCrEMUFanCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.7.7
cpqCrEMUPowerSupplyStatus mandatory Enumeration .1.3.6.1.4.1.232.141.2.7.8
cpqCrEMUPowerSupplyCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.7.9
cpqCrExpCab .1.3.6.1.4.1.232.141.2.8
cpqCrExpCabPowerSupplyStatus mandatory Enumeration .1.3.6.1.4.1.232.141.2.8.1
cpqCrExpCabTemperatureCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.8.10
cpqCrExpCabFanStatus mandatory Enumeration .1.3.6.1.4.1.232.141.2.8.2
cpqCrExpCabTemperatureStatus mandatory Enumeration .1.3.6.1.4.1.232.141.2.8.3
cpqCrExpCabCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.8.6
cpqCrExpCabPowerSupplyCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.8.7
cpqCrExpCabFanCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.8.9
cpqCrPartition .1.3.6.1.4.1.232.141.2.9
cpqCrPartitionTable mandatory .1.3.6.1.4.1.232.141.2.9.1
cpqCrPartitionEntry mandatory cpqCrPartitionLogDrvIndexcpqCrPartitionIndex .1.3.6.1.4.1.232.141.2.9.1.1
cpqCrPartitionLogDrvIndex mandatory Integer32 .1.3.6.1.4.1.232.141.2.9.1.1.1
cpqCrPartitionIndex mandatory Integer32 .1.3.6.1.4.1.232.141.2.9.1.1.2
cpqCrPartitionRAIDLevel mandatory Enumeration .1.3.6.1.4.1.232.141.2.9.1.1.3
cpqCrPartitionStatus mandatory Enumeration .1.3.6.1.4.1.232.141.2.9.1.1.4
cpqCrPartitionSize mandatory Integer32 .1.3.6.1.4.1.232.141.2.9.1.1.5
cpqCrPartitionCondition mandatory Enumeration .1.3.6.1.4.1.232.141.2.9.1.1.6
cpqCrTrap .1.3.6.1.4.1.232.141.3
cpqCrInterfaceTrap .1.3.6.1.4.1.232.141.3.1
cpqCrCntlrTrap .1.3.6.1.4.1.232.141.3.2
cpqCrLogDrvTrap .1.3.6.1.4.1.232.141.3.3
cpqCrSpareDrvTrap .1.3.6.1.4.1.232.141.3.4
cpqCrPhyDrvTrap .1.3.6.1.4.1.232.141.3.5
cpqCrEMUTrap .1.3.6.1.4.1.232.141.3.7
cpqCrExpCabTrap .1.3.6.1.4.1.232.141.3.8
Notifications / Traps (34)
NameOIDDescription
cpqCrController1FailureTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.2.0.1
The primary controller in the subsytem has failed.
          
Details:
  The primary Controller has failed.
          
User Action:
  Replace controller.  Possible causes are controller physically
  removed, actual hardware failure.
cpqCrController1InformationTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.2.0.2
The primary controller in the subsytem has recovered.
          
Details:
  The primary controller has recovered.
          
User Action:
  None.
cpqCrController2FailureTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.2.0.3
The secondary controller in the subsytem has failed.
          
Details:
  The secondary controller has failed.
          
User Action:
  Replace controller.  Possible causes are controller
  physically removed, actual hardware failure.
cpqCrController2InformationTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.2.0.4
The secondary controller in the subsytem has recovered.
          
Details:
  The secondary controller has recovered.
          
User Action:
  None.
cpqCrLogDriveInformationTrap .1.3.6.1.4.1.232.141.3.3.0.5
A RAIDset has become optimal.
          
Details:
  A RAIDset has become optimal due to a successful completion
  of the reconstruction process.
          
User Action:
  None.
cpqCrLogDriveFailureTrap .1.3.6.1.4.1.232.141.3.3.0.6
A RAIDset has failed.
          
Details:
  The RAIDset has failed and is off-line.
          
User Action:
  Possible cause is too many failed disk drives that make up
  the RAIDset, the OS can no longer communicate with the RAIDset
  for other reasons.
cpqCrLogDriveReconstructTrap .1.3.6.1.4.1.232.141.3.3.0.7
A RAIDset has started the reconstruction process.
          
Details:
  The RAIDset has started the reconstruction process but is available
  for normal use.
  Possible causes are an available disk drive was created as
  a spare to be inserted into the set, an existing spare was
  automatically added to the set for reconstruction upon failure
  of a member disk device.
          
User Action:
  None.
cpqCrLogDriveReducedTrap .1.3.6.1.4.1.232.141.3.3.0.8
A RAIDset has become degraded.
          
Details:
  A RAIDset has become degraded due to a member disk device
  failure.
          
User Action:
  Replace the failed disk device; add a spare to the system
  to cause a reconstruct.
cpqCrLogDriveInitializingTrap .1.3.6.1.4.1.232.141.3.3.0.9
A RAIDset is initializing.
          
Details:
  A RAIDset is in the process of being intialized.
          
User Action:
  None.
cpqCrDiskInformationTrap .1.3.6.1.4.1.232.141.3.5.0.10
A disk drive has recovered.
          
Details:
  A disk device has recovered.
          
User Action:
  None.
cpqCrDiskFailureTrap .1.3.6.1.4.1.232.141.3.5.0.11
A disk drive has failed.
          
Details:
  A disk device has failed.
          
User Action:
  Replace the disk device.
cpqCrDiskReconstructTrap .1.3.6.1.4.1.232.141.3.5.0.12
A disk drive has started the reconstruction process.
          
Details:
  A disk member of a logical drive has begun the reconstruction
  process and will be available for use when reconstruction is
  complete.
          
User Action:
  Wait for the reconstruction to complete.
cpqCrDiskAvailableTrap .1.3.6.1.4.1.232.141.3.5.0.13
A disk drive has been made available for use.
          
Details:
  A disk drive has been physically added or set to the
  Available state. It can be used as a RAIDset member or as a Spare.
          
User Action:
  None.
cpqCrDiskSpareTrap .1.3.6.1.4.1.232.141.3.5.0.14
A disk drive has been made a Spare.
          
Details:
  A disk drive has been set to Spare status from Available and
  may be used in a RAID 1, RAID 0+1 or RAID 5 logical disk should
  a member device fail in one of those RAIDsets.
          
User Action:
  None.
cpqCrPhyDiskInformationTrap .1.3.6.1.4.1.232.141.3.5.0.30
A disk drive has recovered.
          
Details:
  A disk device has recovered.
          
User Action:
  None.
cpqCrPhyDiskFailureTrap .1.3.6.1.4.1.232.141.3.5.0.31
A disk drive has failed.
          
Details:
  A disk device has failed.
          
User Action:
  Replace the disk device.
cpqCrPhyDiskReconstructTrap .1.3.6.1.4.1.232.141.3.5.0.32
A disk drive has started the reconstruction process.
          
Details:
  A disk member of a logical drive has begun the reconstruction
  process and will be available for use when reconstruction is
  complete.
          
User Action:
  Wait for the reconstruction to complete.
cpqCrPhyDiskAvailableTrap .1.3.6.1.4.1.232.141.3.5.0.33
A disk drive has been made available for use.
          
Details:
  A disk drive has been physically added or set to the
  Available state. It can be used as a RAIDset member or as a Spare.
          
User Action:
  None.
cpqCrPhyDiskSpareTrap .1.3.6.1.4.1.232.141.3.5.0.34
A disk drive has been made a Spare.
          
Details:
  A disk drive has been set to Spare status from Available and
  may be used in a RAID 1, RAID 0+1 or RAID 5 logical disk should
  a member device fail in one of those RAIDsets.
          
User Action:
  None.
cpqCrEMUNormalTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.7.0.15
Primary enclosure state is normal.
          
Details:
  The overall condition of the primary enclosure has returned
  to normal.
          
          
User Action:
  None.
cpqCrEMUFanFailureTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.7.0.16
Fan has failed.
          
Details:
  One of the cooling fans in the primary enclosure has
  failed.
          
User Action:
  Replace the cooling fan. Possible causes are fan
  physically removed, actual hardware failure.
cpqCrEMUFanInformationTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.7.0.17
The fan has recovered.
          
Details:
  The cooling fan in the primary enclosure has recovered.
          
User Action:
  None.
cpqCrEMUPowerSupplyFailureTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.7.0.18
Power supply has failed.
          
Details:
  One of the power supplies in the primary enclosure has
  failed.
          
User Action:
  Replace the power supply. Possible causes are power
  supply physically removed, power cord unplugged, actual
  hardware failure.
cpqCrEMUPowerSupplyInformationTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.7.0.19
The power supply has recovered.
          
Details:
  The power supply in the primary enclosure has recovered.
          
User Action:
  None.
cpqCrEMUTemperatureWarningTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.7.0.23
Primary enclosure temperature warning.
          
Details:
  The temperature in the primary enclosure has triggered a
  warning condition detected by the controller.
          
User Action:
  Check the cooling fans in the primary enclosure.
cpqCrEMUTemperatureCriticalTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.7.0.24
Primary enclosure temperature critical!.
          
Details:
  The temperature in the primary enclosure has triggered a
  critical condition detected by the controller.
          
User Action:
  Check the cooling fans in the primary enclosure.
cpqCrEMUTemperatureInformationTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.7.0.25
Primary enclosure temperature normal.
          
Details:
  The temperature in the primary enclosure has
  returned to normal.
          
User Action:
  None.
cpqCrExpCabFanFailureTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.8.0.20
Fan has failed in expansion cabinet.
          
Details:
  One of the cooling fans in the expansion cabinet has
  failed.
          
User Action:
  Replace the cooling fan. Possible causes are fan
  physically removed, actual hardware failure.
cpqCrExpCabFanInformationTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.8.0.21
Fan has recovered.
          
Details:
  A cooling fan in the expansion cabinet has returned to a
  normal state.
          
User Action:
  None.
cpqCrExpCabPowerSupplyFailureTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.8.0.22
Power supply has failed.
          
Details:
  One of the power supplies in the expansion cabinet has
  failed.
          
User Action:
  Replace the power supply. Possible causes are power
  supply physically removed, power cord unplugged, actual
  hardware failure.
cpqCrExpCabTemperatureWarningTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.8.0.26
Expansion cabinet temperature warning.
          
Details:
  The temperature in the expansion cabinet has triggered a
  warning condition detected by the controller.
          
User Action:
  Check the cooling fans in the expansion cabinet.
cpqCrExpCabTemperatureCriticalTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.8.0.27
Expansion cabinet temperature critical!
          
Details:
  The temperature in the expansion cabinet has triggered a
  critical condition detected by the controller.
          
User Action:
  Check the cooling fans in the expansion cabinet.
cpqCrExpCabTemperatureInformationTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.8.0.28
Expansion cabinet temperature normal.
          
Details:
  The temperature in the expansion cabinet has returned to
  normal.
          
User Action:
  None.
cpqCrExpCabPowerSupplyInformationTrap
RFC1213-MIBsysName
.1.3.6.1.4.1.232.141.3.8.0.29
The power supply has recovered.
          
Details:
  The power supply in the expansion cabinet has recovered.
          
User Action:
  None.