cpqCrEMUPowerSupplyStatus
CPQCR-MIB ·
.1.3.6.1.4.1.232.141.2.7.8
Object
scalar
mandatory
Enumeration
Primary enclosure power supply status.
The primary enclosure power supply status is:
OK (2)
Status is normal.
Critical (3)
Power supply is installed and marked as failed.
Not Installed (4)
One of the redundant power supplies has been removed.
Unknown (5)
Information unavailable.
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | other |
2 | emuPwrSupplyOK |
3 | emuPwrSupplyCritical |
4 | emuPwrSupplyNotInstalled |
5 | emuPwrSupplyUnknown |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqCrEMUBoardTemperatureStatus obsolete Environmental Monitoring Unit (EMU) Board Temperature status.
The System Board Temperature status as determined by the EMU is:
Not Installed (2)
The … | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.1 |
| cpqCrEMUTemperatureStatus mandatory Primary enclosure temperature status.
The primary enclosure temperature status is:
OK (2)
Status is normal.
Critical (3)
C… | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.10 |
| cpqCrEMUTemperatureLevel mandatory Primary enclosure temperature.
Indicates the temperature within the primary enclosure in degrees
Celsius. | scalar | Integer32 | .1.3.6.1.4.1.232.141.2.7.11 |
| cpqCrEMUTemperatureCondition mandatory Primary enclosure temperature condition.
This value represents the overall condition of the
temperature in the primary enclosure. | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.12 |
| cpqCrEMUEnclosureTemperatureStatus obsolete Environmental Monitoring Unit (EMU) Enclosure Temperature status.
The Enclosure Housing Temperature status as determined by the EMU is:
Not Installed (2)
… | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.2 |
| cpqCrEMUBoardTemperatureLevel obsolete Environmental Monitoring Unit (EMU) Board Temperature.
Indicates the System Board temperature in degrees Fahrenheit. | scalar | Integer32 | .1.3.6.1.4.1.232.141.2.7.3 |
| cpqCrEMUEnclosureTemperatureLevel obsolete Environmental Monitoring Unit (EMU) Enclosure Temperature.
Indicates the Enclosure Housing temperature in degrees Fahrenheit. | scalar | Integer32 | .1.3.6.1.4.1.232.141.2.7.4 |
| cpqCrEMUCondition mandatory Primary enclosure condition.
This value represents the overall condition of the primary
enclosure. | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.5 |
| cpqCrEMUFanStatus mandatory Primary enclosure fan status.
The primary enclosure fan status is:
OK (2)
Status is normal.
Critical (3)
Fan has failed.
Unknow… | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.6 |
| cpqCrEMUFanCondition mandatory Primary enclosure fan condition.
This value represents the overall condition of the fan
in the primary enclosure. | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.7 |
| cpqCrEMUPowerSupplyCondition mandatory Primary enclosure power supply condition.
This value represents the overall condition of the power
supply in the primary enclosure. | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.9 |