cpqCrEMUBoardTemperatureStatus
CPQCR-MIB ·
.1.3.6.1.4.1.232.141.2.7.1
Object
scalar
obsolete
Enumeration
Environmental Monitoring Unit (EMU) Board Temperature status.
The System Board Temperature status as determined by the EMU is:
Not Installed (2)
The board temperature can not be detected in the unit.
Normal (3)
The board temperature detected by the EMU is normal.
Below Normal (4)
The board temperature detected by the EMU is below normal.
Above Normal (5)
The board temperature detected by the EMU is above normal.
Far Below Normal (6)
The board temperature detected by the EMU is far below normal.
Far Above Normal (7)
The board temperature detected by the EMU is far above normal.
Back To Normal (8)
The board temperature detected by the EMU has returned to normal.
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | other |
2 | emuBoardTempNotInstalled |
3 | emuBoardTempNormal |
4 | emuBoardTempBelowNormal |
5 | emuBoardTempAboveNormal |
6 | emuBoardTempFarBelowNormal |
7 | emuBoardTempFarAboveNormal |
8 | emuBoardTempBackToNormal |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqCrEMUTemperatureStatus mandatory Primary enclosure temperature status.
The primary enclosure temperature status is:
OK (2)
Status is normal.
Critical (3)
C… | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.10 |
| cpqCrEMUTemperatureLevel mandatory Primary enclosure temperature.
Indicates the temperature within the primary enclosure in degrees
Celsius. | scalar | Integer32 | .1.3.6.1.4.1.232.141.2.7.11 |
| cpqCrEMUTemperatureCondition mandatory Primary enclosure temperature condition.
This value represents the overall condition of the
temperature in the primary enclosure. | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.12 |
| cpqCrEMUEnclosureTemperatureStatus obsolete Environmental Monitoring Unit (EMU) Enclosure Temperature status.
The Enclosure Housing Temperature status as determined by the EMU is:
Not Installed (2)
… | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.2 |
| cpqCrEMUBoardTemperatureLevel obsolete Environmental Monitoring Unit (EMU) Board Temperature.
Indicates the System Board temperature in degrees Fahrenheit. | scalar | Integer32 | .1.3.6.1.4.1.232.141.2.7.3 |
| cpqCrEMUEnclosureTemperatureLevel obsolete Environmental Monitoring Unit (EMU) Enclosure Temperature.
Indicates the Enclosure Housing temperature in degrees Fahrenheit. | scalar | Integer32 | .1.3.6.1.4.1.232.141.2.7.4 |
| cpqCrEMUCondition mandatory Primary enclosure condition.
This value represents the overall condition of the primary
enclosure. | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.5 |
| cpqCrEMUFanStatus mandatory Primary enclosure fan status.
The primary enclosure fan status is:
OK (2)
Status is normal.
Critical (3)
Fan has failed.
Unknow… | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.6 |
| cpqCrEMUFanCondition mandatory Primary enclosure fan condition.
This value represents the overall condition of the fan
in the primary enclosure. | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.7 |
| cpqCrEMUPowerSupplyStatus mandatory Primary enclosure power supply status.
The primary enclosure power supply status is:
OK (2)
Status is normal.
Critical (3)
Power supply is… | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.8 |
| cpqCrEMUPowerSupplyCondition mandatory Primary enclosure power supply condition.
This value represents the overall condition of the power
supply in the primary enclosure. | scalar | Enumeration | .1.3.6.1.4.1.232.141.2.7.9 |