cpqCrPartitionStatus
CPQCR-MIB ·
.1.3.6.1.4.1.232.141.2.9.1.1.4
Object
column
mandatory
Enumeration
Logical Drive Status.
The logical drive can be in one of the following states:
Good (2)
Indicates that the logical drive is fully operational.
Reduced (3)
Indicates that the logical drive is operating in a degraded or
reduced state. One or more of the physical disks which make
up the logical drive are either missing or failed, but the
logical drive can continue to operate without data loss.
Failed (4)
Indicates that the logical drive is not operational.
Reconstructing (5)
Indicates that the logical drive is regenerating a failed
physical drive's data onto a replacement drive that is part
of the logical drive.
All user data remains available during the reconstruction
process, but some performance reduction may occur when a
request requires access to the device being reconstructed.
Initializing (6)
Indicates that the controller is writing its file structure
onto the logical drive's member devices.
Context
- MIB
- CPQCR-MIB
- OID
.1.3.6.1.4.1.232.141.2.9.1.1.4- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqCrPartitionEntry
- Table
- cpqCrPartitionTable
- Siblings
- 5
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | other |
2 | good |
3 | reduced |
4 | failed |
5 | reconstructing |
6 | initializing |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqCrPartitionLogDrvIndex mandatory Clustered RAID Logical Drive Index.
This maps the logical drives into their respective RAIDsets.
RAIDset index 'i' under the RAIDset group owns the
associated drive… | column | Integer32 | .1.3.6.1.4.1.232.141.2.9.1.1.1 |
| cpqCrPartitionIndex mandatory Clustered RAID Logical Drive Index.
This logical drive number keeps track of multiple instances of
logical drives which are part of the same RAIDset. For each
RAID… | column | Integer32 | .1.3.6.1.4.1.232.141.2.9.1.1.2 |
| cpqCrPartitionRAIDLevel mandatory Logical Drive RAID Level.
This shows the RAID level of the logical drive.
To change the RAID level, run the CR3500 Array
Configuration Utility.
The f… | column | Enumeration | .1.3.6.1.4.1.232.141.2.9.1.1.3 |
| cpqCrPartitionSize mandatory Logical Drive Size.
This is the size of the logical drive in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturer… | column | Integer32 | .1.3.6.1.4.1.232.141.2.9.1.1.5 |
| cpqCrPartitionCondition mandatory Logical drive condition.
This value represents the overall condition of this logical
drive and any associated physical drives. | column | Enumeration | .1.3.6.1.4.1.232.141.2.9.1.1.6 |