CPQCR-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
41

cpqCrCntlrTable

table mandatory
.1.3.6.1.4.1.232.141.2.2.1 · 1 row entry · 11 columns
Clustered RAID Array Controller Table.
cpqCrCntlrEntry entry .1.3.6.1.4.1.232.141.2.2.1.1
Clustered RAID Array Controller Entry.
Indexes
cpqCrCntlrIndex
Column Syntax OID
cpqCrCntlrIndex mandatory
Clustered RAID Array Controller Index.

This value is a logical number whose meaning is OS dependent.
Each physical controller has one unique controller number
associated with it.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.2.1.1.1
cpqCrCntlrSerialNumber mandatory
CR3500 Controller Serial Number.
OctetString
Constraints:
range: 0-9
.1.3.6.1.4.1.232.141.2.2.1.1.2
cpqCrCntlrFWRev mandatory
Clustered RAID Array Controller Firmware Revision.

The firmware revision of the Clustered RAID Controller.
This value can be used to help identify a particular revision
of the controller.
OctetString
Constraints:
range: 0-9
.1.3.6.1.4.1.232.141.2.2.1.1.3
cpqCrCntlrCondition mandatory
The condition of the device. This value represents the overall
condition of this controller, and any associated logical drives,
physical drives, and array accelerators.
Enumeration
Enumerated Values:
1other
2ok
3degraded
4failed
.1.3.6.1.4.1.232.141.2.2.1.1.4
cpqCrCntlrCurrentRole mandatory
Clustered RAID Array Controller Current Role.

For duplexed array controllers, this is the controllers current
role. The following values are valid:

other (1)
Indicates that the instrumen…
Enumeration
Enumerated Values:
1other
2notDuplexed
3active
4backup
.1.3.6.1.4.1.232.141.2.2.1.1.8
cpqCrCntlrDriveOwnership mandatory
Clustered RAID Array Controller Drive Ownership.

For duplexed controllers, indicates to which controller slot
the shared devices are associated.

The following values are valid:
Enumeration
Enumerated Values:
1other
2owner
3notOwner
.1.3.6.1.4.1.232.141.2.2.1.1.9
cpqCrCntlrRebuildRate mandatory
Clustered RAID Array Controller Rebuild Rate.

Determines the rate at which disks are to be rebuilt if
there is I/O activity.

1 = Minimum rate
100 = Maximum rate
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.232.141.2.2.1.1.10
cpqCrCntlrCreateRate mandatory
Clustered RAID Array Controller Create Rate.

Determines the rate at which RAIDsets are to be created if
there is I/O activity.

1 = Minimum rate
100 = maximum rate
Integer32
Constraints:
range: 1-100
.1.3.6.1.4.1.232.141.2.2.1.1.11
cpqCrCntlrCacheSize mandatory
Clustered RAID Array Controller Cache Size.

Size of the controller's cache in MB.
Integer32
Constraints:
range: 0-512
.1.3.6.1.4.1.232.141.2.2.1.1.12
cpqCrCntlrSimmSizeA mandatory
Clustered RAID Array Controller Memory Module Size.

Size of the memory module in slot A in MB.
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.232.141.2.2.1.1.13
cpqCrCntlrSimmSizeB mandatory
Clustered RAID Array Controller Memory Module Size.

Size of the memory module in slot B in MB.
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.232.141.2.2.1.1.14

cpqCrLogDrvTable

table mandatory
.1.3.6.1.4.1.232.141.2.3.1 · 1 row entry · 10 columns
Clustered RAID RAIDset Table.
          
A table of RAIDset entries.
cpqCrLogDrvEntry entry .1.3.6.1.4.1.232.141.2.3.1.1
Clustered RAID RAIDset Entry.

A RAIDset entry.
Indexes
cpqCrLogDrvCntlrIndex cpqCrLogDrvIndex
Column Syntax OID
cpqCrLogDrvCntlrIndex mandatory
Clustered RAID RAIDset Controller Index.

This maps the RAIDsets into their respective controllers.
Controller index 'i' under the controller group owns the
associated drives in the RAIDset which use that …
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.3.1.1.1
cpqCrLogDrvIndex mandatory
Clustered RAID RAIDset Index.

This logical drive number keeps track of multiple instances of
logical drives which are on the same controller. For each
controller index value, the logical drive index star…
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.3.1.1.2
cpqCrLogDrvRAIDLevel mandatory
RAID Level.

This shows the RAID level of the RAIDset.
To change the RAID level, run the CL1850 Array
Configuration Utility.

The following values are valid for the RAIDset RAID
Level:
Enumeration
Enumerated Values:
1other
2jbod
3raid0
4raid1
5raid0plus1
6raid4
7raid5
.1.3.6.1.4.1.232.141.2.3.1.1.3
cpqCrLogDrvStatus mandatory
RAIDset Status.

The RAIDset can be in one of the following states:

Good (2)
Indicates that the RAIDset is fully operational.

Reduced (3)
Indicates that the RAIDset is ope…
Enumeration
Enumerated Values:
1other
2good
3reduced
4failed
5reconstructing
6initializing
.1.3.6.1.4.1.232.141.2.3.1.1.4
cpqCrLogDrvRebuildPercentage mandatory
RAIDset Rebuild Percentage Complete.

After a failed physical drive has been replaced, the physical
drive must have its data rebuilt. This value shows how far
the rebuild process has progressed as a perce…
Integer32
Constraints:
range: 0-100
.1.3.6.1.4.1.232.141.2.3.1.1.5
cpqCrLogDrvAvailSpares mandatory
RAIDset Available Spares.

This indicates if this RAIDset has one or more spares
designated for it that are not currently in use by another drive.
Each octet present will be a physical drive ID that is an
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.3.1.1.7
cpqCrLogDrvSize mandatory
RAIDset Size.

This is the size of the RAIDset in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturers sometimes use the number 1,000,000 as a
megabyte w…
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.232.141.2.3.1.1.8
cpqCrLogDrvPhyDrvIDs mandatory
RAIDset Physical Drive IDs.

This lists the physical drive IDs which are associated with this
RAIDset. These are the same IDs which can be used as
indices into the physical drive table. Each byte of the st…
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.3.1.1.9
cpqCrLogDrvCondition mandatory
RAIDset condition.

This value represents the overall condition of this RAIDset
and any associated physical drives.
Enumeration
Enumerated Values:
1other
2ok
3degraded
4failed
.1.3.6.1.4.1.232.141.2.3.1.1.10
cpqCrLogDrvPartitionIDs mandatory
RAIDset Logical Drive IDs.

This lists the logical drive IDs which are associated with this
RAIDset. These are the same IDs which can be used as
indices into the logical drive table. Each byte of the strin…
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.3.1.1.11

cpqCrSpareTable

table mandatory
.1.3.6.1.4.1.232.141.2.4.1 · 1 row entry · 5 columns
Clustered RAID Spare Table.
          
A table of spare entries.
cpqCrSpareEntry entry .1.3.6.1.4.1.232.141.2.4.1.1
Clustered RAID Spare Entry.

An entry in the spare table.
Indexes
cpqCrSpareCntlrIndex cpqCrSparePhyDrvIndex
Column Syntax OID
cpqCrSpareCntlrIndex mandatory
Spare Controller Index.

This index maps the spare drive back to the controller to which
it is attached. The value of this index is the same as the one
used under the controller group.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.4.1.1.1
cpqCrSparePhyDrvIndex mandatory
Physical Drive Index.

This index maps the spare to the physical drive it represents.
The value of this index is the same as the one used with the
physical drive table.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.4.1.1.2
cpqCrSpareStatus mandatory
Spare Status.

This shows the status of the on-line spare drive.

The following values are valid for the spare status:

Hot Spare(5)
The drive attached to this channel…
Enumeration
Enumerated Values:
1other
2empty
3offline
4online
5hotSpare
6warmSpare
7creating
8rebuilding
9addingSpare
10formatting
.1.3.6.1.4.1.232.141.2.4.1.1.3
cpqCrSpareCondition mandatory
Spare Drive condition.

This value represents the overall condition of this spare drive
and any associated physical drives.
Enumeration
Enumerated Values:
1other
2ok
3degraded
4failed
.1.3.6.1.4.1.232.141.2.4.1.1.4
cpqCrSpareScsiID mandatory
SCSI ID.

This value represents the SCSI identifier of this spare drive.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.4.1.1.5

cpqCrPhyDrvTable

table mandatory
.1.3.6.1.4.1.232.141.2.5.1 · 1 row entry · 9 columns
Clustered RAID Physical Drive Table.
          
A table of physical drive entries.
cpqCrPhyDrvEntry entry .1.3.6.1.4.1.232.141.2.5.1.1
Clustered RAID Physical Drive Entry.

A physical drive entry.
Indexes
cpqCrPhyDrvCntlrIndex cpqCrPhyDrvIndex
Column Syntax OID
cpqCrPhyDrvCntlrIndex mandatory
Clustered RAID Physical Drive Controller Index.

This index maps the physical drive back to the controller to
which it is attached. The value of this index is the same as
the one used under the controller …
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.5.1.1.1
cpqCrPhyDrvIndex mandatory
Clustered RAID Physical Drive Index.

This index is used for selecting the physical drive table entry.
This number, along with the cpqCrPhyDrvCntlrIndex uniquely
identify a specific physical drive.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.5.1.1.2
cpqCrPhyDrvVendor mandatory
Physical Drive Vendor.

This is the name of the manufacturer of the physical drive.
This value is based upon the vendor name as returned by the
SCSI inquiry command but may have been modified due to space
OctetString
Constraints:
range: 0-8
.1.3.6.1.4.1.232.141.2.5.1.1.3
cpqCrPhyDrvModel mandatory
Physical Drive Model.

This is a text description of the physical drive. The text that
appears depends upon who manufactured the drive and the drive
type.

For example, you might see: CP320…
OctetString
Constraints:
range: 0-16
.1.3.6.1.4.1.232.141.2.5.1.1.4
cpqCrPhyDrvRevision mandatory
Physical Drive Revision.

This shows the physical drive revision number.
OctetString
Constraints:
range: 0-4
.1.3.6.1.4.1.232.141.2.5.1.1.5
cpqCrPhyDrvStatus mandatory
Physical Drive Status.

This shows the status of the physical drive.

The following values are valid for the physical drive status:

Offline (3)
The drive attached to this c…
Enumeration
Enumerated Values:
1other
2empty
3offline
4online
5hotSpare
6warmSpare
7creating
8rebuilding
9addingSpare
10formatting
.1.3.6.1.4.1.232.141.2.5.1.1.6
cpqCrPhyDrvSize mandatory
Physical Drive Size in MB.

This is the size of the physical drive in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturers sometimes use the number 1,000…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.141.2.5.1.1.7
cpqCrPhyDrvCondition mandatory
Physical Drive condition.

This value represents the overall condition of this physical drive.
Enumeration
Enumerated Values:
1other
2ok
3degraded
4failed
.1.3.6.1.4.1.232.141.2.5.1.1.8
cpqCrPhyDrvScsiID mandatory
SCSI ID.

This value represents the SCSI identifier of this physical
drive.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.5.1.1.9

cpqCrPartitionTable

table mandatory
.1.3.6.1.4.1.232.141.2.9.1 · 1 row entry · 6 columns
Clustered RAID Logical Drive Table.
          
A table of logical drive entries.
cpqCrPartitionEntry entry .1.3.6.1.4.1.232.141.2.9.1.1
Clustered RAID Logical Drive Entry.

A Logical Drive entry.
Indexes
cpqCrPartitionLogDrvIndex cpqCrPartitionIndex
Column Syntax OID
cpqCrPartitionLogDrvIndex mandatory
Clustered RAID Logical Drive Index.

This maps the logical drives into their respective RAIDsets.
RAIDset index 'i' under the RAIDset group owns the
associated drives in the logical drives which use that i…
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.9.1.1.1
cpqCrPartitionIndex mandatory
Clustered RAID Logical Drive Index.

This logical drive number keeps track of multiple instances of
logical drives which are part of the same RAIDset. For each
RAIDset index value, the logical drive index…
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.141.2.9.1.1.2
cpqCrPartitionRAIDLevel mandatory
Logical Drive RAID Level.

This shows the RAID level of the logical drive.
To change the RAID level, run the CR3500 Array
Configuration Utility.

The following values are valid for the logica…
Enumeration
Enumerated Values:
1other
2jbod
3raid0
4raid1
5raid0plus1
6raid4
7raid5
.1.3.6.1.4.1.232.141.2.9.1.1.3
cpqCrPartitionStatus mandatory
Logical Drive Status.

The logical drive can be in one of the following states:

Good (2)
Indicates that the logical drive is fully operational.

Reduced (3)
Indicates that …
Enumeration
Enumerated Values:
1other
2good
3reduced
4failed
5reconstructing
6initializing
.1.3.6.1.4.1.232.141.2.9.1.1.4
cpqCrPartitionSize mandatory
Logical Drive Size.

This is the size of the logical drive in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturers sometimes use the number 1,000,000 as …
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.232.141.2.9.1.1.5
cpqCrPartitionCondition mandatory
Logical drive condition.

This value represents the overall condition of this logical
drive and any associated physical drives.
Enumeration
Enumerated Values:
1other
2ok
3degraded
4failed
.1.3.6.1.4.1.232.141.2.9.1.1.6