cpqCrCntlrCurrentRole
CPQCR-MIB ·
.1.3.6.1.4.1.232.141.2.2.1.1.8
Object
column
mandatory
Enumeration
Clustered RAID Array Controller Current Role.
For duplexed array controllers, this is the controllers current
role. The following values are valid:
other (1)
Indicates that the instrument agent does not recognize the
role of the controller. You may need to upgrade the instrument
agent.
notDuplexed (2)
This array controller is not duplexed.
active (3)
This duplexed array controller is the active controller.
backup (4)
This duplexed array controller is the backup controller.
Context
- MIB
- CPQCR-MIB
- OID
.1.3.6.1.4.1.232.141.2.2.1.1.8- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqCrCntlrEntry
- Table
- cpqCrCntlrTable
- Siblings
- 10
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | other |
2 | notDuplexed |
3 | active |
4 | backup |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqCrCntlrIndex mandatory Clustered RAID Array Controller Index.
This value is a logical number whose meaning is OS dependent.
Each physical controller has one unique controller number
assoc… | column | Integer32 | .1.3.6.1.4.1.232.141.2.2.1.1.1 |
| cpqCrCntlrRebuildRate mandatory Clustered RAID Array Controller Rebuild Rate.
Determines the rate at which disks are to be rebuilt if
there is I/O activity.
1 = Minimum rate
100 =… | column | Integer32 | .1.3.6.1.4.1.232.141.2.2.1.1.10 |
| cpqCrCntlrCreateRate mandatory Clustered RAID Array Controller Create Rate.
Determines the rate at which RAIDsets are to be created if
there is I/O activity.
1 = Minimum rate
100… | column | Integer32 | .1.3.6.1.4.1.232.141.2.2.1.1.11 |
| cpqCrCntlrCacheSize mandatory Clustered RAID Array Controller Cache Size.
Size of the controller's cache in MB. | column | Integer32 | .1.3.6.1.4.1.232.141.2.2.1.1.12 |
| cpqCrCntlrSimmSizeA mandatory Clustered RAID Array Controller Memory Module Size.
Size of the memory module in slot A in MB. | column | Integer32 | .1.3.6.1.4.1.232.141.2.2.1.1.13 |
| cpqCrCntlrSimmSizeB mandatory Clustered RAID Array Controller Memory Module Size.
Size of the memory module in slot B in MB. | column | Integer32 | .1.3.6.1.4.1.232.141.2.2.1.1.14 |
| cpqCrCntlrSerialNumber mandatory CR3500 Controller Serial Number. | column | OctetString | .1.3.6.1.4.1.232.141.2.2.1.1.2 |
| cpqCrCntlrFWRev mandatory Clustered RAID Array Controller Firmware Revision.
The firmware revision of the Clustered RAID Controller.
This value can be used to help identify a particular revi… | column | OctetString | .1.3.6.1.4.1.232.141.2.2.1.1.3 |
| cpqCrCntlrCondition mandatory The condition of the device. This value represents the overall
condition of this controller, and any associated logical drives,
physical drives, and array accelerators. | column | Enumeration | .1.3.6.1.4.1.232.141.2.2.1.1.4 |
| cpqCrCntlrDriveOwnership mandatory Clustered RAID Array Controller Drive Ownership.
For duplexed controllers, indicates to which controller slot
the shared devices are associated.
The … | column | Enumeration | .1.3.6.1.4.1.232.141.2.2.1.1.9 |