cpqCrLogDrvRebuildPercentage

CPQCR-MIB · .1.3.6.1.4.1.232.141.2.3.1.1.5

Object

column mandatory Integer32
RAIDset Rebuild Percentage Complete.
              
After a failed physical drive has been replaced, the physical
drive must have its data rebuilt.  This value shows how far
the rebuild process has progressed as a percentage.
When the value reaches 100, the rebuilding process is complete.
The drive array continues to operate in reduced mode while a
drive is rebuilding.
              
This value is only valid if the RAIDset Status is
reconstructing (6).

Context

MIB
CPQCR-MIB
OID
.1.3.6.1.4.1.232.141.2.3.1.1.5
Type
column
Access
readonly
Status
mandatory
Parent
cpqCrLogDrvEntry
Table
cpqCrLogDrvTable
Siblings
9

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-100

Related Objects

Sibling Objects