cpqCrCntlrCreateRate
CPQCR-MIB ·
.1.3.6.1.4.1.232.141.2.2.1.1.11
Object
column
mandatory
Integer32
Clustered RAID Array Controller Create Rate.
Determines the rate at which RAIDsets are to be created if
there is I/O activity.
1 = Minimum rate
100 = maximum rate
Context
- MIB
- CPQCR-MIB
- OID
.1.3.6.1.4.1.232.141.2.2.1.1.11- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqCrCntlrEntry
- Table
- cpqCrCntlrTable
- Siblings
- 10
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-100
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqCrCntlrIndex mandatory Clustered RAID Array Controller Index.
This value is a logical number whose meaning is OS dependent.
Each physical controller has one unique controller number
assoc… | column | Integer32 | .1.3.6.1.4.1.232.141.2.2.1.1.1 |
| cpqCrCntlrRebuildRate mandatory Clustered RAID Array Controller Rebuild Rate.
Determines the rate at which disks are to be rebuilt if
there is I/O activity.
1 = Minimum rate
100 =… | column | Integer32 | .1.3.6.1.4.1.232.141.2.2.1.1.10 |
| cpqCrCntlrCacheSize mandatory Clustered RAID Array Controller Cache Size.
Size of the controller's cache in MB. | column | Integer32 | .1.3.6.1.4.1.232.141.2.2.1.1.12 |
| cpqCrCntlrSimmSizeA mandatory Clustered RAID Array Controller Memory Module Size.
Size of the memory module in slot A in MB. | column | Integer32 | .1.3.6.1.4.1.232.141.2.2.1.1.13 |
| cpqCrCntlrSimmSizeB mandatory Clustered RAID Array Controller Memory Module Size.
Size of the memory module in slot B in MB. | column | Integer32 | .1.3.6.1.4.1.232.141.2.2.1.1.14 |
| cpqCrCntlrSerialNumber mandatory CR3500 Controller Serial Number. | column | OctetString | .1.3.6.1.4.1.232.141.2.2.1.1.2 |
| cpqCrCntlrFWRev mandatory Clustered RAID Array Controller Firmware Revision.
The firmware revision of the Clustered RAID Controller.
This value can be used to help identify a particular revi… | column | OctetString | .1.3.6.1.4.1.232.141.2.2.1.1.3 |
| cpqCrCntlrCondition mandatory The condition of the device. This value represents the overall
condition of this controller, and any associated logical drives,
physical drives, and array accelerators. | column | Enumeration | .1.3.6.1.4.1.232.141.2.2.1.1.4 |
| cpqCrCntlrCurrentRole mandatory Clustered RAID Array Controller Current Role.
For duplexed array controllers, this is the controllers current
role. The following values are valid:
… | column | Enumeration | .1.3.6.1.4.1.232.141.2.2.1.1.8 |
| cpqCrCntlrDriveOwnership mandatory Clustered RAID Array Controller Drive Ownership.
For duplexed controllers, indicates to which controller slot
the shared devices are associated.