ES-RACKTIVITY-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
9
Rows
9
Columns
411
eESNTable
table.1.3.6.1.4.1.34097.9.65.1
·
1 row entry
·
65 columns
Temperature Humidity Presure Airflow Waterleak
Temperature Humidity Presure Airflow Waterleak
Indexes
esnModuleIndex esnIndex
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
aGeneralModuleStatus
General status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.65.1.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aSpecificModuleStatus
Specific status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.65.1.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aCurrentTime
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
|
UNIXSNMPv2-SMITimeTicksr/w Textual Convention: SNMPv2-SMITimeTicks Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.65.1.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aVoltage
Gets the voltage of a power module. (unit: 0.01V)
|
VUhundredth Textual Convention: Uhundredth Unsigned32 |
.1.3.6.1.4.1.34097.9.65.1.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aStatePortCur
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
|
CURPORTSTATE Textual Convention: CURPORTSTATE EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aTemperature
Gets the current temperature of a temperature sensor. (unit: 0.1K)
|
KUtenth Textual Convention: Utenth Unsigned32 |
.1.3.6.1.4.1.34097.9.65.1.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aHumidity
Gets the relative humidity. (unit: 0.1RH)
|
RHUtenth Textual Convention: Utenth Unsigned32 |
.1.3.6.1.4.1.34097.9.65.1.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aAirflow
Gets the current airflow level. (unit: 0.1m/s)
|
m/sUtenth Textual Convention: Utenth Unsigned32 |
.1.3.6.1.4.1.34097.9.65.1.1.23 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aDewPoint
Gets the current dewpoint. Taking the current humidity into consideration, condensation will occur if the temperature drops below this level. (unit: 0.1K)
|
KUnsigned32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.65.1.1.25 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aPressure
Gets the atmospheric pressure. (unit: 0.1hPa)
|
hPaUtenth Textual Convention: Utenth Unsigned32 |
.1.3.6.1.4.1.34097.9.65.1.1.26 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aAnalogueInput
Gets the value of an analog input (voltage). (unit: mV)
|
mVSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.65.1.1.27 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aWaterleak
Gets the current state of the water leak sensor.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.65.1.1.28 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMotionDetected
Gets or resets whether motion has been detected.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.65.1.1.29 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aIOPort
Gets the state of a digital input.
|
Unsigned32 Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.65.1.1.30 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aHighCurrent
The current for high values (unit: 0.1A)
|
AInteger32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.65.1.1.41 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aHighPower
The power for high values (unit: 0.01kW)
|
kWInteger32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.65.1.1.43 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aModuleName
Gets, sets or defaults the module name.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.65.1.1.10001 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aFirmwareVersion
Gets the version of the module's firmware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.65.1.1.10002 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aHardwareVersion
Gets the version of a module's hardware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.65.1.1.10003 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aFirmwareID
Gets the ID of the module's firmware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.65.1.1.10004 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aHardwareID
Gets the ID of a module's hardware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.65.1.1.10005 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aDisplayTimeOn
Gets, sets or defaults the display sleep timer. If the display is inactive for longer than this time, the display turns off to save power. Time is in minutes. (unit: min)
|
minUnsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.65.1.1.10032 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMaxVoltageWarning
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
|
VUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.65.1.1.10047 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMinVoltageWarning
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
|
VUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.65.1.1.10049 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMinTemperatureWarning
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.65.1.1.10052 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMaxTemperatureWarning
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.65.1.1.10053 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMinHumidityWarning
Gets, sets or defaults the minimum relative humidity warning level (use DEF accessor to reset). (unit: 0.1RH)
|
RHUnsigned32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.34097.9.65.1.1.10054 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMaxHumidityWarning
Gets, sets or defaults the maximum relative humidity warning level (use DEF accessor to reset). (unit: 0.1RH)
|
RHUnsigned32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.34097.9.65.1.1.10055 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aCurrentWarningEvent
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10078 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aPowerWarningEvent
Enables or disables the SNMP trap if the power warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10080 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aVoltageWarningEvent
Enables or disables the SNMP trap if the voltage warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10086 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aTemperatureWarningEvent
Enables or disables the SNMP trap if the temperature warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10087 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aHumidityWarningEvent
Enables or disables the SNMP trap if the humidity warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10088 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aDewPointWarning
Gets, sets or defaults the dewpoint warning level. If the temperature difference between the current temperature and the dewpoint temperature drops below this value, an event is generated. (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.65.1.1.10092 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aDewPointWarningEvent
Enables or disables the SNMP trap if the dewpoint warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10093 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aDewPointViolationEvent
Enables or disables the SNMP trap if the dewpoint temperature is reached.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10094 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aPressureWarningEvent
Enables or disables the SNMP trap if the atmospheric pressure warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10095 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMinPressureWarning
Gets, sets or defaults the minimum atmospheric pressure warning level. (unit: 0.1hPa)
|
hPaUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.65.1.1.10096 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMaxPressureWarning
Gets, sets or defaults the maximum atmospheric pressure warning level. (unit: 0.1hPa)
|
hPaUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.65.1.1.10097 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aDisplayBrightness
Gets, sets or defaults the display brightness (if supported).
|
Unsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.65.1.1.10098 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMotionSensitivity
Gets, sets or defaults the sensitivity of a motion sensor.
|
Unsigned32r/w Constraints: range: 0-127 |
.1.3.6.1.4.1.34097.9.65.1.1.10107 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aExternalSensorLabel
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.65.1.1.10109 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aRelayLabel
Gets, sets or defaults an Energy Sensor relay label.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.65.1.1.10110 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMinAnalogueInputWarning
Gets, sets or defaults the lower warning level for an analog input. A warning is generated if this level is exceeded. (unit: mV)
|
mVUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.65.1.1.10111 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMaxAnalogueInputWarning
Gets, sets or defaults the upper warning level for an analog input. A warning is generated if this level is exceeded.
|
Unsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.65.1.1.10112 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aWaterleakWarning
Gets, sets or defaults the water leak detection state (0 = disabled, other values = enabled).
|
Unsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.65.1.1.10113 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMinAirflowWarning
Gets, sets or defaults the minimum warning level for an airflow sensor. A warning is generated if this level is exceeded.
|
Unsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.65.1.1.10114 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMaxAirflowWarning
Gets, sets or defaults the maximum warning level for an airflow sensor. A warning is generated if this level is exceeded.
|
Unsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.65.1.1.10115 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aAnalogueInputWarningEvent
Enables or disables the SNMP trap if the analog input warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10116 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aWaterleakWarningEvent
Enables or disables the SNMP trap if a water leak is detected.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10117 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aAirflowWarningEvent
Enables or disables the SNMP trap if the airflow warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10118 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aRelayAssertActionEvent
Enables or disables the SNMP trap if an Energy Sensor relay is asserted.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10119 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aRelayDeassertActionEvent
Enables or disables the SNMP trap if an Energy Sensor relay is deasserted.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10120 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMotionWarning
Gets, sets or defaults the motion warning threshold.
|
Unsigned32r/w Constraints: range: 0-127 |
.1.3.6.1.4.1.34097.9.65.1.1.10141 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMotionWarningEvent
Enables or disables the SNMP trap if the motion warning threshold is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10149 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aDeviceID
The ID of the device.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.65.1.1.10150 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aDeviceVersion
The version of the device.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.65.1.1.10151 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aSysName
The full name of the device.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.65.1.1.10152 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMaxHighCurrentWarning
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
|
AInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.65.1.1.10165 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMinHighCurrentWarning
Gets sets or defaults the minimum high current warning level. (unit: 0.1A)
|
AInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.65.1.1.10176 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMinHighPowerWarning
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
|
kWInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.65.1.1.10177 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aMaxHighPowerWarning
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
|
kWInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.65.1.1.10178 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
aIOPortWarningEvent
Enables or disables the SNMP trap if the IO Port change state.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.65.1.1.10192 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
esnIndex
Index for the selected ESN Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.65.1.1.65537 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
esnModuleIndex
Selected ESN Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.65.1.1.65538 |
eThreePhasePowerTable
table.1.3.6.1.4.1.34097.9.66.1
·
1 row entry
·
2 columns
NO_INFO
NO_INFO
Indexes
threephasepowerModuleIndex threephasepowerIndex
| Column | Syntax | OID |
|---|---|---|
|
threephasepowerIndex
Index for the selected ThreePhasePower Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.66.1.1.65537 |
|
threephasepowerModuleIndex
Selected ThreePhasePower Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.66.1.1.65538 |
eDisplayModuleTable
table.1.3.6.1.4.1.34097.9.68.1
·
1 row entry
·
15 columns
NO_INFO
NO_INFO
Indexes
displaymoduleModuleIndex displaymoduleIndex
| Column | Syntax | OID |
|---|---|---|
|
dGeneralModuleStatus
General status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.68.1.1.1 |
|
dSpecificModuleStatus
Specific status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.68.1.1.2 |
|
dCurrentTime
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
|
UNIXSNMPv2-SMITimeTicksr/w Textual Convention: SNMPv2-SMITimeTicks Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.68.1.1.3 |
|
dTemperature
Gets the current temperature of a temperature sensor. (unit: 0.1K)
|
KUtenth Textual Convention: Utenth Unsigned32 |
.1.3.6.1.4.1.34097.9.68.1.1.11 |
|
dTimeOnline
Gets the amount of seconds since the last reset. (unit: s)
|
sSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.68.1.1.24 |
|
dModuleName
Gets, sets or defaults the module name.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.68.1.1.10001 |
|
dFirmwareVersion
Gets the version of the module's firmware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.68.1.1.10002 |
|
dHardwareVersion
Gets the version of a module's hardware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.68.1.1.10003 |
|
dFirmwareID
Gets the ID of the module's firmware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.68.1.1.10004 |
|
dHardwareID
Gets the ID of a module's hardware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.68.1.1.10005 |
|
dMinTemperatureWarning
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.68.1.1.10052 |
|
dMaxTemperatureWarning
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.68.1.1.10053 |
|
dDisplayAllDevices
If a display need to show all devices or just a small list
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.68.1.1.10237 |
|
displaymoduleIndex
Index for the selected DisplayModule Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.68.1.1.65537 |
|
displaymoduleModuleIndex
Selected DisplayModule Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.68.1.1.65538 |
eEnergyMonitorTable
table.1.3.6.1.4.1.34097.9.69.1
·
1 row entry
·
43 columns
NO_INFO
NO_INFO
Indexes
energymonitorModuleIndex energymonitorIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
eGeneralModuleStatus
General status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.69.1.1.1 |
||||
|
eSpecificModuleStatus
Specific status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.69.1.1.2 |
||||
|
eCurrentTime
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
|
UNIXSNMPv2-SMITimeTicksr/w Textual Convention: SNMPv2-SMITimeTicks Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.69.1.1.3 |
||||
|
eVoltage
Gets the voltage of a power module. (unit: 0.01V)
|
VUhundredth Textual Convention: Uhundredth Unsigned32 |
.1.3.6.1.4.1.34097.9.69.1.1.4 |
||||
|
eFrequency
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
|
HzUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.69.1.1.5 |
||||
|
eCurrent
Gets the current of an outlet. (unit: 0.001A)
|
AUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.69.1.1.6 |
||||
|
ePower
Gets the power of an outlet. (unit: W)
|
WSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.69.1.1.7 |
||||
|
eActiveEnergy
Gets the energy used by an outlet. (unit: 0.001kWh)
|
kWhUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.69.1.1.9 |
||||
|
eApparentEnergy
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
|
kVAhUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.69.1.1.10 |
||||
|
eTemperature
Gets the current temperature of a temperature sensor. (unit: 0.1K)
|
KUtenth Textual Convention: Utenth Unsigned32 |
.1.3.6.1.4.1.34097.9.69.1.1.11 |
||||
|
eApparentPower
Gets the apparent power of an outlet. (unit: VA)
|
VASNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.69.1.1.15 |
||||
|
ePowerFactor
Gets the power factor of an outlet. (unit: %)
|
%SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.69.1.1.16 |
||||
|
eTotalCurrent
Gets the total current of a power module. (unit: 0.001A)
|
AUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.69.1.1.17 |
||||
|
eTotalRealPower
Gets the total power level of a power module. (unit: W)
|
WSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.69.1.1.18 |
||||
|
eTotalApparentPower
Gets the total apparent power of a power module. (unit: VA)
|
VASNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.69.1.1.19 |
||||
|
eTotalActiveEnergy
Gets the total energy of a power module. (unit: 0.001kWh)
|
kWhUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.69.1.1.20 |
||||
|
eTotalApparentEnergy
Gets the total apparent energy of a power module. (unit: 0.001kVAh)
|
kVAhUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.69.1.1.21 |
||||
|
eTotalPowerFactor
Gets the total power factor of a power module. (unit: %)
|
%SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.69.1.1.22 |
||||
|
eTimeOnline
Gets the amount of seconds since the last reset. (unit: s)
|
sSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.69.1.1.24 |
||||
|
eTotalHarmonicDistortion
total harmonic distortion - outlet (unit: 0.1%)
|
%Unsigned32 Constraints: range: 0-1000 |
.1.3.6.1.4.1.34097.9.69.1.1.50 |
||||
|
eModuleName
Gets, sets or defaults the module name.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.69.1.1.10001 |
||||
|
eFirmwareVersion
Gets the version of the module's firmware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.69.1.1.10002 |
||||
|
eHardwareVersion
Gets the version of a module's hardware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.69.1.1.10003 |
||||
|
eFirmwareID
Gets the ID of the module's firmware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.69.1.1.10004 |
||||
|
eHardwareID
Gets the ID of a module's hardware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.69.1.1.10005 |
||||
|
eMaxCurrentWarning
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.001A)
|
AUnsigned32r/w Constraints: range: 100-8000 |
.1.3.6.1.4.1.34097.9.69.1.1.10039 |
||||
|
eMaxPowerWarning
Gets, sets or defaults the maximum power warning level of an outlet. (unit: W)
|
WUnsigned32r/w Constraints: range: 20-2000 |
.1.3.6.1.4.1.34097.9.69.1.1.10041 |
||||
|
eMaxTotalCurrentWarning
Gets, sets or defaults the total maximum current warning level of a power module. (unit: 0.001A)
|
AUnsigned32r/w Constraints: range: 100-16000 |
.1.3.6.1.4.1.34097.9.69.1.1.10043 |
||||
|
eMaxTotalPowerWarning
Gets, sets or defaults the maximum total power warning level. (unit: W)
|
WUnsigned32r/w Constraints: range: 20-4000 |
.1.3.6.1.4.1.34097.9.69.1.1.10045 |
||||
|
eMaxVoltageWarning
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
|
VUnsigned32r/w Constraints: range: 5000-30000 |
.1.3.6.1.4.1.34097.9.69.1.1.10047 |
||||
|
eMinVoltageWarning
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
|
VUnsigned32r/w Constraints: range: 5000-30000 |
.1.3.6.1.4.1.34097.9.69.1.1.10049 |
||||
|
eMinTemperatureWarning
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.69.1.1.10052 |
||||
|
eMaxTemperatureWarning
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.69.1.1.10053 |
||||
|
eCurrentWarningEvent
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.69.1.1.10078 |
||||
|
ePowerWarningEvent
Enables or disables the SNMP trap if the power warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.69.1.1.10080 |
||||
|
eTotalCurrentWarningEvent
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.69.1.1.10082 |
||||
|
eTotalPowerWarningEvent
Enables or disables the SNMP trap if the total power warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.69.1.1.10084 |
||||
|
eVoltageWarningEvent
Enables or disables the SNMP trap if the voltage warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.69.1.1.10086 |
||||
|
eTemperatureWarningEvent
Enables or disables the SNMP trap if the temperature warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.69.1.1.10087 |
||||
|
eMicroIntTimeThreshold
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
|
msUnsigned32r/w Constraints: range: 10-65535 |
.1.3.6.1.4.1.34097.9.69.1.1.10135 |
||||
|
eMicroIntEvent
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.69.1.1.10136 |
||||
|
energymonitorIndex
Index for the selected EnergyMonitor Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.69.1.1.65537 |
||||
|
energymonitorModuleIndex
Selected EnergyMonitor Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.69.1.1.65538 |
eMasterTable
table.1.3.6.1.4.1.34097.9.77.1
·
1 row entry
·
126 columns
NO_INFO
NO_INFO
Indexes
masterModuleIndex masterIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
mGeneralModuleStatus
General status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.77.1.1.1 |
||||
|
mSpecificModuleStatus
Specific status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.77.1.1.2 |
||||
|
mCurrentTime
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
|
UNIXSNMPv2-SMITimeTicksr/w Textual Convention: SNMPv2-SMITimeTicks Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.77.1.1.3 |
||||
|
mVoltage
Gets the voltage of a power module. (unit: 0.01V)
|
VUhundredth Textual Convention: Uhundredth Unsigned32 |
.1.3.6.1.4.1.34097.9.77.1.1.4 |
||||
|
mTemperature
Gets the current temperature of a temperature sensor. (unit: 0.1K)
|
KUtenth Textual Convention: Utenth Unsigned32 |
.1.3.6.1.4.1.34097.9.77.1.1.11 |
||||
|
mCurrentIP
Gets the current IP address. To set the IP address, use IPADDR instead.
|
SNMPv2-SMIIpAddress Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.14 |
||||
|
mTotalCurrent
Gets the total current of a power module. (unit: 0.001A)
|
AUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.77.1.1.17 |
||||
|
mTotalRealPower
Gets the total power level of a power module. (unit: W)
|
WSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.77.1.1.18 |
||||
|
mTotalActiveEnergy
Gets the total energy of a power module. (unit: 0.001kWh)
|
kWhUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.77.1.1.20 |
||||
|
mLineCurrent
Gets the current line current. (unit: 0.001A)
|
AUnsigned32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.32 |
||||
|
mFuseCurrent
Gets the current through a fuse. (unit: 0.001A)
|
AUnsigned32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.33 |
||||
|
mCurrentSubNetMask
Gets the current subnet mask. To set the subnet mask use SNMSK instead.
|
SNMPv2-SMIIpAddress Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.34 |
||||
|
mCurrentDNSServer
Gets the current DNS server. To set the DNS server use DNSSRV instead.
|
SNMPv2-SMIIpAddress Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.35 |
||||
|
mCurrentStdGateway
Gets the current standard gateway. To set the standard gateway use STDGW instead.
|
SNMPv2-SMIIpAddress Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.36 |
||||
|
mUPSPresent
Checks if a UPS is present.
|
Unsigned32 Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.37 |
||||
|
mUPSStatus
Gets the working status of a UPS (if its working on its batteries or not).
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.77.1.1.38 |
||||
|
mUPSEstimatedRunTime
Gets the estimated run time of a UPS. (unit: min)
|
minUnsigned32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.39 |
||||
|
mUPSBatteryLevel
The current UPS battery level. (unit: 0.1%)
|
%Unsigned32 Constraints: range: 0-1000 |
.1.3.6.1.4.1.34097.9.77.1.1.40 |
||||
|
mHighCurrent
The current for high values (unit: 0.1A)
|
AStenth Textual Convention: Stenth Integer32 |
.1.3.6.1.4.1.34097.9.77.1.1.41 |
||||
|
mUpsCommunicationStatus
Status information of communication with the UPS
|
Unsigned32 Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.42 |
||||
|
mHighPower
The power for high values (unit: 0.01kW)
|
kWInteger32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.77.1.1.43 |
||||
|
mTotalHighCurrent
The current for high values (unit: 0.1A)
|
AInteger32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.44 |
||||
|
mTotalHighPower
The power for high values (unit: 0.01kW)
|
kWInteger32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.77.1.1.45 |
||||
|
mPositiveEnergy
Gets the positive energy used by an outlet. (unit: 0.001kWh)
|
kWhUnsigned32 Constraints: range: 0-4294967295 |
.1.3.6.1.4.1.34097.9.77.1.1.46 |
||||
|
mNegativeEnergy
Gets the negative energy used by an outlet. (unit: 0.001kWh)
|
kWhUnsigned32 Constraints: range: 0-4294967295 |
.1.3.6.1.4.1.34097.9.77.1.1.47 |
||||
|
mTotalPositiveEnergy
Gets the positive energy of the module. (unit: 0.001kWh)
|
kWhUnsigned32 Constraints: range: 0-4294967295 |
.1.3.6.1.4.1.34097.9.77.1.1.48 |
||||
|
mTotalNegativeEnergy
Gets the negative energy of the module. (unit: 0.001kWh)
|
kWhUnsigned32 Constraints: range: 0-4294967295 |
.1.3.6.1.4.1.34097.9.77.1.1.49 |
||||
|
mCloudStatus
Gets the status of the connection with the cloud. 0 = Idle state; 1 = Disabled; 2 = Initialising; 3 = Initialising - No connection; 4 = Initialising - No key; 5 = Connection Ok; 6 = Connection Failed; 7 = Connection Fai…
|
Unsigned32 Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.77.1.1.56 |
||||
|
mStatus
status of a module
|
Unsigned32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.1000 |
||||
|
mModuleName
Gets, sets or defaults the module name.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10001 |
||||
|
mFirmwareVersion
Gets the version of the module's firmware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.10002 |
||||
|
mHardwareVersion
Gets the version of a module's hardware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.10003 |
||||
|
mFirmwareID
Gets the ID of the module's firmware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10004 |
||||
|
mHardwareID
Gets the ID of a module's hardware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10005 |
||||
|
mRackName
Gets, sets or defaults the name of the rack.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10006 |
||||
|
mRackPosition
Gets, sets or defaults the position in the rack.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10007 |
||||
|
mIPAddress
Gets, sets or defaults the IP address (when DHCP is disabled).
|
SNMPv2-SMIIpAddressr/w Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.10011 |
||||
|
mSubNetMask
Gets, sets or defaults the subnet mask (when DHCP is disabled).
|
SNMPv2-SMIIpAddressr/w Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.10012 |
||||
|
mStdGateWay
Gets, sets or defaults the standard gateway (when DHCP is disabled).
|
SNMPv2-SMIIpAddressr/w Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.10013 |
||||
|
mDnsServer
Gets, sets or defaults the IP address of the used DNS server (when DHCP is disabled).
|
SNMPv2-SMIIpAddressr/w Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.10014 |
||||
|
mMAC
Gets the MAC address of a master module.
|
SNMPv2-TCMacAddress Textual Convention: SNMPv2-TCMacAddress OctetStringType Constraints: range: 6 |
.1.3.6.1.4.1.34097.9.77.1.1.10015 |
||||
|
mDHCPEnable
Enables, disables or defaults DHCP. Set to 1 to enable DHCP, or 0 to disable DHCP.
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10016 |
||||
|
mNTPServer
Gets, sets or defaults the NTP (Network Time Protocol) server IP address.
|
SNMPv2-SMIIpAddressr/w Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.10017 |
||||
|
mUseDefaultNTPServer
Enables, disables or defaults the usage of the default NTP (Network Time Protocol) server (pool.ntp.org).
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10018 |
||||
|
mUseNTP
Enables, disables or defaults NTP (Network Time Protocol). Set to 1 to enable NTP, or 0 to disable NTP.
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10019 |
||||
|
mSNMPTrapRecvIP
Gets, sets or defaults the SNMP trap receiver IP address.
|
SNMPv2-SMIIpAddressr/w Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.10020 |
||||
|
mSNMPTrapRecvPort
Gets, sets or defaults the SNMP tap receiver port.
|
Unsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.10021 |
||||
|
mSNMPControl
Enables, disables or defaults write access over SNMP. Set to 1 to disable write access, or 0 to enable write access.
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10024 |
||||
|
mECSServer
Gets, sets or defaults the ECS (Energy Cloud Sentinel) server IP address.
|
SNMPv2-SMIIpAddressr/w Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.10028 |
||||
|
mUseECSServer
Enables, disables or defaults the use of an ECS (Energy Cloud Sentinel) server. Set to 1 to enable or 0 to disable.
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10029 |
||||
|
mDisplayLock
Gets, sets or defaults the display lock. If the display is locked, you can still view information on the display, but you are not allowed to change settings through the menu system.
|
Unsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.77.1.1.10031 |
||||
|
mDisplayTimeOn
Gets, sets or defaults the display sleep timer. If the display is inactive for longer than this time, the display turns off to save power. Time is in minutes. (unit: min)
|
minUnsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.77.1.1.10032 |
||||
|
mMaxVoltageWarning
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
|
VUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.10047 |
||||
|
mMinVoltageWarning
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
|
VUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.10049 |
||||
|
mMinTemperatureWarning
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.77.1.1.10052 |
||||
|
mMaxTemperatureWarning
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.77.1.1.10053 |
||||
|
mGeneralEventEnable
Gets, sets or defaults general events. If set to 0, no events will be generated. Set to 1 to generate events on media indicated by the event bitfields.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10074 |
||||
|
mSNMPSysContact
Gets, sets or defaults the SNMP contact information.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10075 |
||||
|
mCurrentWarningEvent
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10078 |
||||
|
mPowerWarningEvent
Enables or disables the SNMP trap if the power warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10080 |
||||
|
mTotalCurrentWarningEvent
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10082 |
||||
|
mTotalPowerWarningEvent
Enables or disables the SNMP trap if the total power warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10084 |
||||
|
mVoltageWarningEvent
Enables or disables the SNMP trap if the voltage warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10086 |
||||
|
mTemperatureWarningEvent
Enables or disables the SNMP trap if the temperature warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10087 |
||||
|
mDisplayBrightness
Gets, sets or defaults the display brightness (if supported).
|
Unsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.77.1.1.10098 |
||||
|
mECSServerPort
Gets, sets or defaults the ECS (Energy Cloud Sentinel) server port.
|
Unsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.10106 |
||||
|
mExternalSensorLabel
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10109 |
||||
|
mHttpsOnly
Enables or disables the use of HTTPS (secure HTTP). Set to 1 to enable HTTPS only, or 0 to also enable HTTP.
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10127 |
||||
|
mTelnetSsl
Enables or disables the use of Telnet SSL (secure Telnet). Set to 1 to enable Telnet SSL, or 0 to disable Telnet SSL).
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10128 |
||||
|
mCookieTimeToLive
The TTL (Time To Live) of the website cookie. (unit: min)
|
minUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.10130 |
||||
|
mLineCurrentWarningThreshold
Gets, sets the warning threshold of the linecurrent. (unit: 0.001A)
|
AUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.10131 |
||||
|
mLineCurrentOffThreshold
Gets, sets the off threshold of the linecurrent. (unit: 0.001A)
|
AUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.77.1.1.10132 |
||||
|
mLineCurrentWarningEvent
Enables or disables the SNMP trap if the linecurrent warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10133 |
||||
|
mLineCurrentOffEvent
Enables or disables the SNMP trap if the linecurrent off level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10134 |
||||
|
mFuseCurrentWarningThreshold
Gets, sets or defaults the maximum current warning threshold per fuse. (unit: 0.001A)
|
AUnsigned32r/w Constraints: range: 0-32000 |
.1.3.6.1.4.1.34097.9.77.1.1.10142 |
||||
|
mFuseCurrentOffThreshold
Gets, sets or defaults the maximum current off threshold per fuse. (unit: 0.001A)
|
AUnsigned32r/w Constraints: range: 0-32000 |
.1.3.6.1.4.1.34097.9.77.1.1.10143 |
||||
|
mFuseCurrentWarningEvent
Enables or disables the SNMP trap if the fusecurrent warning threshold is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10144 |
||||
|
mFuseCurrentOffEvent
Enables or disables the SNMP trap if the fusecurrent off threshold is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10145 |
||||
|
mDeviceID
The ID of the device.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10150 |
||||
|
mDeviceVersion
The version of the device.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.10151 |
||||
|
mSysName
The full name of the device.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10152 |
||||
|
mElectricalTopology
Gets the electrical topology of the unit.
|
Unsigned32 Constraints: range: 0-2 |
.1.3.6.1.4.1.34097.9.77.1.1.10153 |
||||
|
mFusePortTopology
Gets the topology between the outlets and fuses.
|
Unsigned32 Constraints: range: 0-6 |
.1.3.6.1.4.1.34097.9.77.1.1.10154 |
||||
|
mLineFuseTopology
Gets the topology between the inlet (cable or connection) and the fuses.
|
Unsigned32 Constraints: range: 0-3 |
.1.3.6.1.4.1.34097.9.77.1.1.10155 |
||||
|
mSSOIPAddress
Gets, sets the IP address of an SSO (Smart Style Office).
|
SNMPv2-SMIIpAddressr/w Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.77.1.1.10156 |
||||
|
mSSOLoginCredentials
Gets, sets the login credentials of an SSO (Smart Style Office).
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10157 |
||||
|
mSSOGracefullShutdown
Gets, sets the string to send if the UPS' battery level is below the set threshold.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10158 |
||||
|
mUPSWarningLevel
Gets, sets or defaults the graceful shutdown threshold of a UPS.
|
Unsigned32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.34097.9.77.1.1.10159 |
||||
|
mUPSOffLevel
Gets, sets or defaults the threshold of a UPS to set outlets off.
|
Unsigned32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.34097.9.77.1.1.10160 |
||||
|
mMaxHighCurrentWarning
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
|
AInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.77.1.1.10165 |
||||
|
mUpsMonitoringProtocol
Disables/Enables UPS monitoring and selects the protocol used for UPS monitoring. 0 = Disabled; 1 = Use old APC protocol
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10167 |
||||
|
mUpsEmergencyThreshold
When the UPS battery level goes below this threshold a shutdown request will be sent to all agents (unit: 0.1%)
|
%Unsigned32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.34097.9.77.1.1.10168 |
||||
|
mUpsRecoveryThreshold
When the UPS battery level goes above this threshold a outlets will be powered on as configured by the user (unit: 0.1%)
|
%Unsigned32r/w Constraints: range: 0-1000 |
.1.3.6.1.4.1.34097.9.77.1.1.10169 |
||||
|
mUpsEventFlags
Event flags for events related to the UPS monitoring
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.77.1.1.10170 |
||||
|
mRecoveryPowerThreshold
When the UPS was on battery and it went below UPSEMERGTHRES, the outlets that have a load below the RECOVPOWERTHRES will be power cycled once the UPS is back on mains power and exceeds UPSRECOVTHRES (unit: W)
|
WUnsigned32r/w Constraints: range: 20-4000 |
.1.3.6.1.4.1.34097.9.77.1.1.10171 |
||||
|
mMinHighCurrentWarning
Gets sets or defaults the minimum high current warning level. (unit: 0.1A)
|
AInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.77.1.1.10176 |
||||
|
mMinHighPowerWarning
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
|
kWInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.77.1.1.10177 |
||||
|
mMaxHighPowerWarning
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
|
kWInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.77.1.1.10178 |
||||
|
mHeartbeatInterval
Interval (in seconds) between 2 heartbeat SNMP traps, Set to 0 to disable (unit: s)
|
sUnsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.77.1.1.10179 |
||||
|
mMinTotalHighCurrentWarning
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
|
AInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.77.1.1.10180 |
||||
|
mMaxTotalHighCurrentWarning
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
|
AInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.77.1.1.10181 |
||||
|
mMinTotalHighPowerWarning
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
|
kWInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.77.1.1.10182 |
||||
|
mMaxTotalHighPowerWarning
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
|
kWInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.77.1.1.10183 |
||||
|
mCloudState
Set if the device needs to push info to the init cloud (val=0) or to the normal cloud (val=1)
|
Unsigned32r/w Constraints: range: 0-2 |
.1.3.6.1.4.1.34097.9.77.1.1.10208 |
||||
|
mSensorBias
get or set the DC sensor bias (unit: mV)
|
mVInteger32r/w Constraints: range: -32768-32767 |
.1.3.6.1.4.1.34097.9.77.1.1.10210 |
||||
|
mDaisyChainDeviceMode
allowed modes: 0: standalone (master without daisy chain slaves) 1: daisy chain master 2: daisy chain slave 1 3: daisy chain slave 2 4: daisy chain slave 3
|
Unsigned32r/w Constraints: range: 0-4 |
.1.3.6.1.4.1.34097.9.77.1.1.10211 |
||||
|
mSNMPTrapUser
Gets, sets or defaults the SNMP tap user out of the user list.
|
Unsigned32r/w Constraints: range: 0-4 |
.1.3.6.1.4.1.34097.9.77.1.1.10212 |
||||
|
mUSMUser
Gets, sets or defaults the SNMP USM security user
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10213 |
||||
|
mUSMAuthPassphrase
Gets, sets or defaults the SNMP USM authentication passphrase (Always MD5)
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10214 |
||||
|
mUSMPrivPassphrase
Gets, sets or defaults the SNMP USM private passphrase (Always AES)
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10215 |
||||
|
mSNMPV2GetSetEnable
Gets, sets or defaults the SNMP V2 Enable for get ,set or walk but not for traps.
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10216 |
||||
|
mSNMPV3GetSetEnable
Gets, sets or defaults the SNMP V3 Enable for get ,set or walk but not for traps.
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10217 |
||||
|
mUSMAuthPassphraseLength
Gets, sets or defaults the SNMP USM authentication passphrase length
|
Unsigned32r/w Constraints: range: 0-16 |
.1.3.6.1.4.1.34097.9.77.1.1.10218 |
||||
|
mUSMPrivPassphraseLength
Gets, sets or defaults the SNMP USM private passphrase length
|
Unsigned32r/w Constraints: range: 0-16 |
.1.3.6.1.4.1.34097.9.77.1.1.10219 |
||||
|
mSNMPTrapEnable
Gets, sets or defaults the SNMP Trap Enable per trap account
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10222 |
||||
|
mLDAPAttribute
Attribute linked to the LDAPFilter
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10227 |
||||
|
mLDAPPath
Relative Path to be used for the LDAPFilter
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10228 |
||||
|
mLDAPAdminGroupName
GroupName for Admin Credentials in LDAP
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10229 |
||||
|
mLDAPRestrictedGroupName
GroupName for Restricted Credentials in LDAP
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10230 |
||||
|
mLDAPGuestGroupName
GroupName for Guest Credentials in LDAP
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10231 |
||||
|
mLDAPEnable
Enable or disable login via LDAP credentials
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10232 |
||||
|
mLDAPLoginWrapper
Wrapper for login in with LDAP
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10233 |
||||
|
mLDAPServer
NO_INFO
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.77.1.1.10235 |
||||
|
mLocalAuthEnable
Set if local authentication is still possible if LDAP is enabled
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.77.1.1.10236 |
||||
|
masterIndex
Index for the selected Master Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.77.1.1.65537 |
||||
|
masterModuleIndex
Selected Master Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.77.1.1.65538 |
ePowerTable
table.1.3.6.1.4.1.34097.9.80.1
·
1 row entry
·
88 columns
NO_INFO
NO_INFO
Indexes
powerModuleIndex powerIndex
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pGeneralModuleStatus
General status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.80.1.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pSpecificModuleStatus
Specific status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.80.1.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pCurrentTime
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
|
UNIXSNMPv2-SMITimeTicksr/w Textual Convention: SNMPv2-SMITimeTicks Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.80.1.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pVoltage
Gets the voltage of a power module. (unit: 0.01V)
|
VUhundredth Textual Convention: Uhundredth Unsigned32 |
.1.3.6.1.4.1.34097.9.80.1.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pFrequency
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
|
HzUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.80.1.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pCurrent
Gets the current of an outlet. (unit: 0.001A)
|
AUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.80.1.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pPower
Gets the power of an outlet. (unit: W)
|
WSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.80.1.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pStatePortCur
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
|
CURPORTSTATE Textual Convention: CURPORTSTATE EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pActiveEnergy
Gets the energy used by an outlet. (unit: 0.001kWh)
|
kWhUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.80.1.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pApparentEnergy
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
|
kVAhUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.80.1.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTemperature
Gets the current temperature of a temperature sensor. (unit: 0.1K)
|
KUtenth Textual Convention: Utenth Unsigned32 |
.1.3.6.1.4.1.34097.9.80.1.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pApparentPower
Gets the apparent power of an outlet. (unit: VA)
|
VASNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.80.1.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pPowerFactor
Gets the power factor of an outlet. (unit: %)
|
%SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.80.1.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTotalCurrent
Gets the total current of a power module. (unit: 0.001A)
|
AUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.80.1.1.17 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTotalRealPower
Gets the total power level of a power module. (unit: W)
|
WSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.80.1.1.18 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTotalApparentPower
Gets the total apparent power of a power module. (unit: VA)
|
VASNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.80.1.1.19 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTotalActiveEnergy
Gets the total energy of a power module. (unit: 0.001kWh)
|
kWhUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.80.1.1.20 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTotalApparentEnergy
Gets the total apparent energy of a power module. (unit: 0.001kVAh)
|
kVAhUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.80.1.1.21 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTotalPowerFactor
Gets the total power factor of a power module. (unit: %)
|
%SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.80.1.1.22 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTimeOnline
Gets the amount of seconds since the last reset. (unit: s)
|
sSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.80.1.1.24 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTotalHarmonicDistortion
total harmonic distortion - outlet (unit: 0.1%)
|
%Unsigned32 Constraints: range: 0-1000 |
.1.3.6.1.4.1.34097.9.80.1.1.50 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pPhase
the phase between 2 waves (unit: degr)
|
degrUnsigned32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.80.1.1.51 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pBigCurrent
Gets the current of an outlet. (unit: 0.0001A)
|
ASNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.80.1.1.52 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pBigPower
Gets the power of an outlet. (unit: 0.001W)
|
WUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.80.1.1.53 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pBigApparentPower
Gets the apparent power of an outlet. (unit: 0.001VA)
|
VAUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.80.1.1.54 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pDetectedPhase
Gives the best matching Phase per currentsensor. Updated every 8s. returnes 255 if no good phaselink is found
|
Unsigned32 Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.80.1.1.55 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pModuleName
Gets, sets or defaults the module name.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.80.1.1.10001 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pFirmwareVersion
Gets the version of the module's firmware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.80.1.1.10002 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pHardwareVersion
Gets the version of a module's hardware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.80.1.1.10003 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pFirmwareID
Gets the ID of the module's firmware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.80.1.1.10004 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pHardwareID
Gets the ID of a module's hardware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.80.1.1.10005 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pPortName
Gets, sets or defaults the name of an outlet.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.80.1.1.10034 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pPortState
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
|
Unsigned32r/w Constraints: range: 0-2 |
.1.3.6.1.4.1.34097.9.80.1.1.10035 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pCurrentPriorOff
Gets, sets or defaults the priority of an outlet. Priority settings are used when 1 or more outlets must be turned off because the total current of a power module was exceeded.
|
Unsigned32r/w Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.80.1.1.10036 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pDelayOn
Gets, sets or defaults the outlet turn-on delay. Use this to reduce inrush current when the Energy Switch boots. (unit: s)
|
sUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.80.1.1.10037 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxCurrentOff
Gets, sets or defaults the maximum current off level of an outlet. (unit: 0.001A)
|
AUnsigned32r/w Constraints: range: 100-8000 |
.1.3.6.1.4.1.34097.9.80.1.1.10038 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxCurrentWarning
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.001A)
|
AUnsigned32r/w Constraints: range: 100-8000 |
.1.3.6.1.4.1.34097.9.80.1.1.10039 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxPowerOff
Gets, sets or defaults the maximum power off level of an outlet. (unit: W)
|
WUnsigned32r/w Constraints: range: 20-2000 |
.1.3.6.1.4.1.34097.9.80.1.1.10040 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxPowerWarning
Gets, sets or defaults the maximum power warning level of an outlet. (unit: W)
|
WUnsigned32r/w Constraints: range: 20-2000 |
.1.3.6.1.4.1.34097.9.80.1.1.10041 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxTotalCurrentOff
Gets, sets or defaults the total maximum current off level of a power module. (unit: 0.001A)
|
AUnsigned32r/w Constraints: range: 100-16000 |
.1.3.6.1.4.1.34097.9.80.1.1.10042 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxTotalCurrentWarning
Gets, sets or defaults the total maximum current warning level of a power module. (unit: 0.001A)
|
AUnsigned32r/w Constraints: range: 100-16000 |
.1.3.6.1.4.1.34097.9.80.1.1.10043 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxTotalPowerOff
Gets, sets or defaults the maximum total power off level. (unit: W)
|
WUnsigned32r/w Constraints: range: 20-4000 |
.1.3.6.1.4.1.34097.9.80.1.1.10044 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxTotalPowerWarning
Gets, sets or defaults the maximum total power warning level. (unit: W)
|
WUnsigned32r/w Constraints: range: 20-4000 |
.1.3.6.1.4.1.34097.9.80.1.1.10045 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxVoltageWarning
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
|
VUnsigned32r/w Constraints: range: 5000-30000 |
.1.3.6.1.4.1.34097.9.80.1.1.10047 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMinVoltageWarning
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
|
VUnsigned32r/w Constraints: range: 5000-30000 |
.1.3.6.1.4.1.34097.9.80.1.1.10049 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMinTemperatureWarning
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.80.1.1.10052 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxTemperatureWarning
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.80.1.1.10053 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pPortStateEvent
Enables or disables the SNMP trap if the state of an outlet is changed.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10076 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pCurrentOffEvent
Enables or disables the SNMP trap if the outlet current off level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10077 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pCurrentWarningEvent
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10078 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pPowerOffEvent
Enables or disables the SNMP trap if the power off level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10079 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pPowerWarningEvent
Enables or disables the SNMP trap if the power warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10080 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTotalCurrentOffEvent
Enables or disables the SNMP trap if the total outlet current off level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10081 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTotalCurrentWarningEvent
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10082 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTotalPowerOffEvent
Enables or disables the SNMP trap if the total power off level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10083 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTotalPowerWarningEvent
Enables or disables the SNMP trap if the total power warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10084 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pVoltageWarningEvent
Enables or disables the SNMP trap if the voltage warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10086 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pTemperatureWarningEvent
Enables or disables the SNMP trap if the temperature warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10087 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxOverheatingOff
Gets, sets or defaults the maximum overheat temperature off level. (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.80.1.1.10090 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pOverheatingOffEvent
Enables or disables the SNMP trap if the overtemperature off level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10091 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pPowerCycleTime
Gets, sets or defaults the time interval that is used to do a power cycle of an outlet. (unit: s)
|
sUnsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.80.1.1.10099 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pExternalSensorLabel
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.80.1.1.10109 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxOverheatingWarning
Gets, sets or defaults the overheating temperature warning level. (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.80.1.1.10121 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pOverheatingWarningEvent
Enables or disables the SNMP trap if the overheat warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10122 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMicroIntTimeThreshold
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
|
msUnsigned32r/w Constraints: range: 10-65535 |
.1.3.6.1.4.1.34097.9.80.1.1.10135 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMicroIntEvent
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10136 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pSoftFuseCurrentThreshold
The threshold of the soft fuse is a factor of the maximum nominal current off (unit: A)
|
AUnsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.80.1.1.10137 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pSoftFuseDelay
The minimum time the current of an outlet must be above the soft fuse current threshold to switch it off. (unit: ms)
|
msUnsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.80.1.1.10138 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pSoftFuseEvent
Enables or disables the SNMP trap if a soft fuse is triggered.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10139 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pPhaseShiftEvent
Enables or disables the SNMP trap if a phase shift on the voltage is detected.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10140 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pSchedulePortOnTime
Gets, sets or defaults the time for the scheduler to turn on an outlet. (unit: min)
|
minUnsigned32r/w Constraints: range: 0-1439 |
.1.3.6.1.4.1.34097.9.80.1.1.10146 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pSchedulePortOffTime
Gets, sets or defaults the time for the scheduler to turn off an outlet. (unit: min)
|
minUnsigned32r/w Constraints: range: 0-1439 |
.1.3.6.1.4.1.34097.9.80.1.1.10147 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pEnableSchedulePort
Enables or disables the scheduler on an outlet. When enabled the scheduling is repeated daily.
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.80.1.1.10148 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pBlockSetPortOff
Prevent outlets to be set off (only delay on and powercycle are still possible).
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.80.1.1.10161 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pSchedulePortChangeEvent
event if a port has changed state because of the scheduler
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10166 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pAgentIP
IP address of the agent associated to this outlet
|
SNMPv2-SMIIpAddressr/w Textual Convention: SNMPv2-SMIIpAddress OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.80.1.1.10172 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pAgentPort
Network port on which the associated agent will listen
|
Unsigned32r/w Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.80.1.1.10173 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pAgentCommunicationEventFlags
Event flags for events related to agent communication
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.80.1.1.10174 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pAlwaysOn
Outlets marked as Always On can only be power cycled by the user
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.80.1.1.10175 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pGenericTransducerParameters
sets the slope of the transducer transfer function when the generic transducer type is selected (unit: mA/V)
|
mA/VInteger32r/w Constraints: range: 2000-2000000000 |
.1.3.6.1.4.1.34097.9.80.1.1.10190 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxBigCurrentWarning
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.0001A)
|
AUnsigned32r/w Constraints: range: 100-400000000 |
.1.3.6.1.4.1.34097.9.80.1.1.10193 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMaxBigPowerWarning
Gets, sets or defaults the maximum power warning level of an outlet. (unit: 0.001W)
|
WUnsigned32r/w Constraints: range: 2000-2000000000 |
.1.3.6.1.4.1.34097.9.80.1.1.10194 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pGroupNumber
Group number per port to group ports
|
Unsigned32r/w Constraints: range: 0-5 |
.1.3.6.1.4.1.34097.9.80.1.1.10195 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pPhaseLink
Link the current port with a voltage phase
|
Unsigned32r/w Constraints: range: 0-8 |
.1.3.6.1.4.1.34097.9.80.1.1.10196 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pCurrentSensorSelector
Selection of the currentsensor connected to port. To enter your own value you need to use 255 and fill in guid 10190.
|
Unsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.80.1.1.10197 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pMinBigCurrentWarning
Gets, sets or defaults the minimum current warning level of a port. (unit: 0.0001A)
|
AUnsigned32r/w Constraints: range: 0-400000000 |
.1.3.6.1.4.1.34097.9.80.1.1.10209 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
powerIndex
Index for the selected Power Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.80.1.1.65537 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
powerModuleIndex
Selected Power Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.80.1.1.65538 |
eMeasuring3PhaseTable
table.1.3.6.1.4.1.34097.9.81.1
·
1 row entry
·
43 columns
NO_INFO
NO_INFO
Indexes
measuring3phaseModuleIndex measuring3phaseIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
qGeneralModuleStatus
General status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.81.1.1.1 |
||||
|
qSpecificModuleStatus
Specific status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.81.1.1.2 |
||||
|
qCurrentTime
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
|
UNIXSNMPv2-SMITimeTicksr/w Textual Convention: SNMPv2-SMITimeTicks Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.81.1.1.3 |
||||
|
qVoltage
Gets the voltage of a power module. (unit: 0.01V)
|
VUhundredth Textual Convention: Uhundredth Unsigned32 |
.1.3.6.1.4.1.34097.9.81.1.1.4 |
||||
|
qFrequency
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
|
HzUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.81.1.1.5 |
||||
|
qActiveEnergy
Gets the energy used by an outlet. (unit: 0.001kWh)
|
kWhUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.81.1.1.9 |
||||
|
qApparentEnergy
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
|
kVAhUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.81.1.1.10 |
||||
|
qTemperature
Gets the current temperature of a temperature sensor. (unit: 0.1K)
|
KUtenth Textual Convention: Utenth Unsigned32 |
.1.3.6.1.4.1.34097.9.81.1.1.11 |
||||
|
qPowerFactor
Gets the power factor of an outlet. (unit: %)
|
%SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.81.1.1.16 |
||||
|
qTimeOnline
Gets the amount of seconds since the last reset. (unit: s)
|
sSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.81.1.1.24 |
||||
|
qIOPort
Gets the state of a digital input.
|
Unsigned32 Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.81.1.1.30 |
||||
|
qTotalHarmonicDistortion
total harmonic distortion - outlet (unit: 0.1%)
|
%Unsigned32 Constraints: range: 0-1000 |
.1.3.6.1.4.1.34097.9.81.1.1.50 |
||||
|
qPhase
the phase between 2 waves (unit: degr)
|
degrUnsigned32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.81.1.1.51 |
||||
|
qBigCurrent
Gets the current of an outlet. (unit: 0.0001A)
|
ASNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.81.1.1.52 |
||||
|
qBigPower
Gets the power of an outlet. (unit: 0.001W)
|
WUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.81.1.1.53 |
||||
|
qBigApparentPower
Gets the apparent power of an outlet. (unit: 0.001VA)
|
VAUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.81.1.1.54 |
||||
|
qStatus
status of a module
|
Unsigned32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.81.1.1.1000 |
||||
|
qModuleName
Gets, sets or defaults the module name.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.81.1.1.10001 |
||||
|
qFirmwareVersion
Gets the version of the module's firmware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.81.1.1.10002 |
||||
|
qHardwareVersion
Gets the version of a module's hardware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.81.1.1.10003 |
||||
|
qFirmwareID
Gets the ID of the module's firmware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.81.1.1.10004 |
||||
|
qHardwareID
Gets the ID of a module's hardware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.81.1.1.10005 |
||||
|
qPortState
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.81.1.1.10035 |
||||
|
qMaxVoltageWarning
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
|
VUnsigned32r/w Constraints: range: 5000-30000 |
.1.3.6.1.4.1.34097.9.81.1.1.10047 |
||||
|
qMinVoltageWarning
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
|
VUnsigned32r/w Constraints: range: 5000-30000 |
.1.3.6.1.4.1.34097.9.81.1.1.10049 |
||||
|
qMinTemperatureWarning
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.81.1.1.10052 |
||||
|
qMaxTemperatureWarning
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
|
KUnsigned32r/w Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.81.1.1.10053 |
||||
|
qPortStateEvent
Enables or disables the SNMP trap if the state of an outlet is changed.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.81.1.1.10076 |
||||
|
qCurrentWarningEvent
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.81.1.1.10078 |
||||
|
qPowerWarningEvent
Enables or disables the SNMP trap if the power warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.81.1.1.10080 |
||||
|
qVoltageWarningEvent
Enables or disables the SNMP trap if the voltage warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.81.1.1.10086 |
||||
|
qTemperatureWarningEvent
Enables or disables the SNMP trap if the temperature warning level is exceeded.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.81.1.1.10087 |
||||
|
qMicroIntTimeThreshold
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
|
msUnsigned32r/w Constraints: range: 10-65535 |
.1.3.6.1.4.1.34097.9.81.1.1.10135 |
||||
|
qMicroIntEvent
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
|
EVENTFLAGSr/w Textual Convention: EVENTFLAGS EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.81.1.1.10136 |
||||
|
qDeviceID
The ID of the device.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.81.1.1.10150 |
||||
|
qDeviceVersion
The version of the device.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.81.1.1.10151 |
||||
|
qMaxBigCurrentWarning
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.0001A)
|
AUnsigned32r/w Constraints: range: 100-400000000 |
.1.3.6.1.4.1.34097.9.81.1.1.10193 |
||||
|
qMaxBigPowerWarning
Gets, sets or defaults the maximum power warning level of an outlet. (unit: 0.001W)
|
WUnsigned32r/w Constraints: range: 2000-2000000000 |
.1.3.6.1.4.1.34097.9.81.1.1.10194 |
||||
|
qCurrentSensorSelector
Selection of the currentsensor connected to port. To enter your own value you need to use 255 and fill in guid 10190.
|
Unsigned32r/w Constraints: range: 0-255 |
.1.3.6.1.4.1.34097.9.81.1.1.10197 |
||||
|
qMinBigCurrentWarning
Gets, sets or defaults the minimum current warning level of a port. (unit: 0.0001A)
|
AUnsigned32r/w Constraints: range: 0-400000000 |
.1.3.6.1.4.1.34097.9.81.1.1.10209 |
||||
|
qkWhMode
Set the mode when to count kWh, 0 = always, 1 = only positive, 2= only negative
|
Unsigned32r/w Constraints: range: 0-2 |
.1.3.6.1.4.1.34097.9.81.1.1.10234 |
||||
|
measuring3phaseIndex
Index for the selected Measuring3Phase Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.81.1.1.65537 |
||||
|
measuring3phaseModuleIndex
Selected Measuring3Phase Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.81.1.1.65538 |
ePCTable
table.1.3.6.1.4.1.34097.9.85.1
·
1 row entry
·
16 columns
NO_INFO
NO_INFO
Indexes
pcModuleIndex pcIndex
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
uGeneralModuleStatus
General status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.85.1.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uSpecificModuleStatus
Specific status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.85.1.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uCurrentTime
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
|
UNIXSNMPv2-SMITimeTicksr/w Textual Convention: SNMPv2-SMITimeTicks Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.85.1.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uVoltage
Gets the voltage of a power module. (unit: 0.01V)
|
VUnsigned32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.85.1.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uCurrent
Gets the current of an outlet. (unit: 0.001A)
|
AUnsigned32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.34097.9.85.1.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uStatePortCur
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
|
CURPORTSTATE Textual Convention: CURPORTSTATE EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.85.1.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uTemperature
Gets the current temperature of a temperature sensor. (unit: 0.1K)
|
KUnsigned32 Constraints: range: 2232-4732 |
.1.3.6.1.4.1.34097.9.85.1.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uHumidity
Gets the relative humidity. (unit: 0.1RH)
|
RHUnsigned32 Constraints: range: 0-1000 |
.1.3.6.1.4.1.34097.9.85.1.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uModuleName
Gets, sets or defaults the module name.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.85.1.1.10001 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uFirmwareVersion
Gets the version of the module's firmware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.85.1.1.10002 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uHardwareVersion
Gets the version of a module's hardware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.85.1.1.10003 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uFirmwareID
Gets the ID of the module's firmware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.85.1.1.10004 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uHardwareID
Gets the ID of a module's hardware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.85.1.1.10005 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
uPortState
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.34097.9.85.1.1.10035 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pcIndex
Index for the selected PC Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.85.1.1.65537 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
pcModuleIndex
Selected PC Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.85.1.1.65538 |
eTestModuleTable
table.1.3.6.1.4.1.34097.9.89.1
·
1 row entry
·
13 columns
Module to test the R-bus
Module to test the R-bus
Indexes
testmoduleModuleIndex testmoduleIndex
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
yGeneralModuleStatus
General status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.89.1.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
ySpecificModuleStatus
Specific status of a module.
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.89.1.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
yCurrentTime
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
|
UNIXSNMPv2-SMITimeTicksr/w Textual Convention: SNMPv2-SMITimeTicks Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.89.1.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
yCurrent
Gets the current of an outlet. (unit: 0.001A)
|
AUthousandth Textual Convention: Uthousandth Unsigned32 |
.1.3.6.1.4.1.34097.9.89.1.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
yStatePortCur
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
|
CURPORTSTATE Textual Convention: CURPORTSTATE EnumerationType Values:
|
.1.3.6.1.4.1.34097.9.89.1.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
yAnalogueInput
Gets the value of an analog input (voltage). (unit: mV)
|
mVSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.34097.9.89.1.1.27 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
yModuleName
Gets, sets or defaults the module name.
|
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.89.1.1.10001 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
yFirmwareVersion
Gets the version of the module's firmware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.89.1.1.10002 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
yHardwareVersion
Gets the version of a module's hardware.
|
Version Textual Convention: Version OctetStringType Constraints: range: 4 |
.1.3.6.1.4.1.34097.9.89.1.1.10003 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
yFirmwareID
Gets the ID of the module's firmware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.89.1.1.10004 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
yHardwareID
Gets the ID of a module's hardware.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.34097.9.89.1.1.10005 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
testmoduleIndex
Index for the selected TestModule Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.89.1.1.65537 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
testmoduleModuleIndex
Selected TestModule Module
|
Integer32 Constraints: range: 1-8 |
.1.3.6.1.4.1.34097.9.89.1.1.65538 |