qVoltageWarningEvent
ES-RACKTIVITY-MIB ·
.1.3.6.1.4.1.34097.9.81.1.1.10086
Object
column
r/w
EVENTFLAGS
Enables or disables the SNMP trap if the voltage warning level is exceeded.
Context
- MIB
- ES-RACKTIVITY-MIB
- OID
.1.3.6.1.4.1.34097.9.81.1.1.10086- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- eMeasuring3PhaseEntry
- Table
- eMeasuring3PhaseTable
- Siblings
- 42
Syntax
EVENTFLAGS
- Source
- EVENTFLAGS
- Base type
Enumeration
Values & Constraints
Type Values
0 | sNMPTrapOff |
1 | sNMPTrapOn |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| qGeneralModuleStatus General status of a module. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.1 |
| qApparentEnergy Gets the apparent energy used by an outlet. (unit: 0.001kVAh) | column | kVAh Uthousandth | .1.3.6.1.4.1.34097.9.81.1.1.10 |
| qStatus status of a module | column | Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.1000 |
| qModuleName Gets, sets or defaults the module name. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.34097.9.81.1.1.10001 |
| qFirmwareVersion Gets the version of the module's firmware. | column | Version | .1.3.6.1.4.1.34097.9.81.1.1.10002 |
| qHardwareVersion Gets the version of a module's hardware. | column | Version | .1.3.6.1.4.1.34097.9.81.1.1.10003 |
| qFirmwareID Gets the ID of the module's firmware. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.34097.9.81.1.1.10004 |
| qHardwareID Gets the ID of a module's hardware. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.34097.9.81.1.1.10005 |
| qPortState Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead. | column | Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.10035 |
| qMaxVoltageWarning Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V) | column | V Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.10047 |
| qMinVoltageWarning Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V) | column | V Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.10049 |
| qMinTemperatureWarning Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | column | K Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.10052 |
| qMaxTemperatureWarning Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | column | K Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.10053 |
| qPortStateEvent Enables or disables the SNMP trap if the state of an outlet is changed. | column | EVENTFLAGS | .1.3.6.1.4.1.34097.9.81.1.1.10076 |
| qCurrentWarningEvent Enables or disables the SNMP trap if the outlet current warning level is exceeded. | column | EVENTFLAGS | .1.3.6.1.4.1.34097.9.81.1.1.10078 |
| qPowerWarningEvent Enables or disables the SNMP trap if the power warning level is exceeded. | column | EVENTFLAGS | .1.3.6.1.4.1.34097.9.81.1.1.10080 |
| qTemperatureWarningEvent Enables or disables the SNMP trap if the temperature warning level is exceeded. | column | EVENTFLAGS | .1.3.6.1.4.1.34097.9.81.1.1.10087 |
| qMicroIntTimeThreshold The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms) | column | ms Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.10135 |
| qMicroIntEvent Enables or disables the SNMP trap if a microinterruption on the voltage is detected. | column | EVENTFLAGS | .1.3.6.1.4.1.34097.9.81.1.1.10136 |
| qDeviceID The ID of the device. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.34097.9.81.1.1.10150 |
| qDeviceVersion The version of the device. | column | Version | .1.3.6.1.4.1.34097.9.81.1.1.10151 |
| qMaxBigCurrentWarning Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.0001A) | column | A Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.10193 |
| qMaxBigPowerWarning Gets, sets or defaults the maximum power warning level of an outlet. (unit: 0.001W) | column | W Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.10194 |
| qCurrentSensorSelector Selection of the currentsensor connected to port. To enter your own value you need to use 255 and fill in guid 10190. | column | Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.10197 |
| qMinBigCurrentWarning Gets, sets or defaults the minimum current warning level of a port. (unit: 0.0001A) | column | A Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.10209 |
| qkWhMode Set the mode when to count kWh, 0 = always, 1 = only positive, 2= only negative | column | Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.10234 |
| qTemperature Gets the current temperature of a temperature sensor. (unit: 0.1K) | column | K Utenth | .1.3.6.1.4.1.34097.9.81.1.1.11 |
| qPowerFactor Gets the power factor of an outlet. (unit: %) | column | % SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.16 |
| qSpecificModuleStatus Specific status of a module. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.2 |
| qTimeOnline Gets the amount of seconds since the last reset. (unit: s) | column | s SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.24 |
| qCurrentTime Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX) | column | UNIX SNMPv2-SMITimeTicks | .1.3.6.1.4.1.34097.9.81.1.1.3 |
| qIOPort Gets the state of a digital input. | column | Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.30 |
| qVoltage Gets the voltage of a power module. (unit: 0.01V) | column | V Uhundredth | .1.3.6.1.4.1.34097.9.81.1.1.4 |
| qFrequency Gets the frequency of the input voltage of a power module. (unit: 0.001Hz) | column | Hz Uthousandth | .1.3.6.1.4.1.34097.9.81.1.1.5 |
| qTotalHarmonicDistortion total harmonic distortion - outlet (unit: 0.1%) | column | % Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.50 |
| qPhase the phase between 2 waves (unit: degr) | column | degr Unsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.51 |
| qBigCurrent Gets the current of an outlet. (unit: 0.0001A) | column | A SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.81.1.1.52 |
| qBigPower Gets the power of an outlet. (unit: 0.001W) | column | W Uthousandth | .1.3.6.1.4.1.34097.9.81.1.1.53 |
| qBigApparentPower Gets the apparent power of an outlet. (unit: 0.001VA) | column | VA Uthousandth | .1.3.6.1.4.1.34097.9.81.1.1.54 |
| measuring3phaseIndex Index for the selected Measuring3Phase Module | column | Integer32 | .1.3.6.1.4.1.34097.9.81.1.1.65537 |
| measuring3phaseModuleIndex Selected Measuring3Phase Module | column | Integer32 | .1.3.6.1.4.1.34097.9.81.1.1.65538 |
| qActiveEnergy Gets the energy used by an outlet. (unit: 0.001kWh) | column | kWh Uthousandth | .1.3.6.1.4.1.34097.9.81.1.1.9 |