ePowerWarningEvent
ES-RACKTIVITY-MIB ·
.1.3.6.1.4.1.34097.9.69.1.1.10080
Object
column
r/w
EVENTFLAGS
Enables or disables the SNMP trap if the power warning level is exceeded.
Context
- MIB
- ES-RACKTIVITY-MIB
- OID
.1.3.6.1.4.1.34097.9.69.1.1.10080- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- eEnergyMonitorEntry
- Table
- eEnergyMonitorTable
- Siblings
- 42
Syntax
EVENTFLAGS
- Source
- EVENTFLAGS
- Base type
Enumeration
Values & Constraints
Type Values
0 | sNMPTrapOff |
1 | sNMPTrapOn |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eGeneralModuleStatus General status of a module. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.1 |
| eApparentEnergy Gets the apparent energy used by an outlet. (unit: 0.001kVAh) | column | kVAh Uthousandth | .1.3.6.1.4.1.34097.9.69.1.1.10 |
| eModuleName Gets, sets or defaults the module name. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.34097.9.69.1.1.10001 |
| eFirmwareVersion Gets the version of the module's firmware. | column | Version | .1.3.6.1.4.1.34097.9.69.1.1.10002 |
| eHardwareVersion Gets the version of a module's hardware. | column | Version | .1.3.6.1.4.1.34097.9.69.1.1.10003 |
| eFirmwareID Gets the ID of the module's firmware. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.34097.9.69.1.1.10004 |
| eHardwareID Gets the ID of a module's hardware. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.34097.9.69.1.1.10005 |
| eMaxCurrentWarning Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.001A) | column | A Unsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.10039 |
| eMaxPowerWarning Gets, sets or defaults the maximum power warning level of an outlet. (unit: W) | column | W Unsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.10041 |
| eMaxTotalCurrentWarning Gets, sets or defaults the total maximum current warning level of a power module. (unit: 0.001A) | column | A Unsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.10043 |
| eMaxTotalPowerWarning Gets, sets or defaults the maximum total power warning level. (unit: W) | column | W Unsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.10045 |
| eMaxVoltageWarning Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V) | column | V Unsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.10047 |
| eMinVoltageWarning Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V) | column | V Unsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.10049 |
| eMinTemperatureWarning Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | column | K Unsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.10052 |
| eMaxTemperatureWarning Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K) | column | K Unsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.10053 |
| eCurrentWarningEvent Enables or disables the SNMP trap if the outlet current warning level is exceeded. | column | EVENTFLAGS | .1.3.6.1.4.1.34097.9.69.1.1.10078 |
| eTotalCurrentWarningEvent Enables or disables the SNMP trap if the total outlet current warning level is exceeded. | column | EVENTFLAGS | .1.3.6.1.4.1.34097.9.69.1.1.10082 |
| eTotalPowerWarningEvent Enables or disables the SNMP trap if the total power warning level is exceeded. | column | EVENTFLAGS | .1.3.6.1.4.1.34097.9.69.1.1.10084 |
| eVoltageWarningEvent Enables or disables the SNMP trap if the voltage warning level is exceeded. | column | EVENTFLAGS | .1.3.6.1.4.1.34097.9.69.1.1.10086 |
| eTemperatureWarningEvent Enables or disables the SNMP trap if the temperature warning level is exceeded. | column | EVENTFLAGS | .1.3.6.1.4.1.34097.9.69.1.1.10087 |
| eMicroIntTimeThreshold The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms) | column | ms Unsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.10135 |
| eMicroIntEvent Enables or disables the SNMP trap if a microinterruption on the voltage is detected. | column | EVENTFLAGS | .1.3.6.1.4.1.34097.9.69.1.1.10136 |
| eTemperature Gets the current temperature of a temperature sensor. (unit: 0.1K) | column | K Utenth | .1.3.6.1.4.1.34097.9.69.1.1.11 |
| eApparentPower Gets the apparent power of an outlet. (unit: VA) | column | VA SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.15 |
| ePowerFactor Gets the power factor of an outlet. (unit: %) | column | % SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.16 |
| eTotalCurrent Gets the total current of a power module. (unit: 0.001A) | column | A Uthousandth | .1.3.6.1.4.1.34097.9.69.1.1.17 |
| eTotalRealPower Gets the total power level of a power module. (unit: W) | column | W SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.18 |
| eTotalApparentPower Gets the total apparent power of a power module. (unit: VA) | column | VA SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.19 |
| eSpecificModuleStatus Specific status of a module. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.2 |
| eTotalActiveEnergy Gets the total energy of a power module. (unit: 0.001kWh) | column | kWh Uthousandth | .1.3.6.1.4.1.34097.9.69.1.1.20 |
| eTotalApparentEnergy Gets the total apparent energy of a power module. (unit: 0.001kVAh) | column | kVAh Uthousandth | .1.3.6.1.4.1.34097.9.69.1.1.21 |
| eTotalPowerFactor Gets the total power factor of a power module. (unit: %) | column | % SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.22 |
| eTimeOnline Gets the amount of seconds since the last reset. (unit: s) | column | s SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.24 |
| eCurrentTime Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX) | column | UNIX SNMPv2-SMITimeTicks | .1.3.6.1.4.1.34097.9.69.1.1.3 |
| eVoltage Gets the voltage of a power module. (unit: 0.01V) | column | V Uhundredth | .1.3.6.1.4.1.34097.9.69.1.1.4 |
| eFrequency Gets the frequency of the input voltage of a power module. (unit: 0.001Hz) | column | Hz Uthousandth | .1.3.6.1.4.1.34097.9.69.1.1.5 |
| eTotalHarmonicDistortion total harmonic distortion - outlet (unit: 0.1%) | column | % Unsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.50 |
| eCurrent Gets the current of an outlet. (unit: 0.001A) | column | A Uthousandth | .1.3.6.1.4.1.34097.9.69.1.1.6 |
| energymonitorIndex Index for the selected EnergyMonitor Module | column | Integer32 | .1.3.6.1.4.1.34097.9.69.1.1.65537 |
| energymonitorModuleIndex Selected EnergyMonitor Module | column | Integer32 | .1.3.6.1.4.1.34097.9.69.1.1.65538 |
| ePower Gets the power of an outlet. (unit: W) | column | W SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.34097.9.69.1.1.7 |
| eActiveEnergy Gets the energy used by an outlet. (unit: 0.001kWh) | column | kWh Uthousandth | .1.3.6.1.4.1.34097.9.69.1.1.9 |