ACS8000-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
21
Rows
21
Columns
400
.1.3.6.1.4.1.10418.26.2.1.10 · 1 row entry · 12 columns
This table contains the list of the scheduled tasks.
acsScheduledTasksTableEntry entry .1.3.6.1.4.1.10418.26.2.1.10.1
each entry has the information about the scheduled task
Indexes
acsScheduledTasksTableIndex
Column Syntax OID
acsScheduledTasksTableIndex
A unique index representing an entry in this table.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.26.2.1.10.1.1
acsScheduledTasksTableType
The type of the scheduled task.
Enumeration
Enumerated Values:
1custom
2cell-modem-ip-test
3cell-modem-signal-check
4save-config-cli
.1.3.6.1.4.1.10418.26.2.1.10.1.2
acsScheduledTasksTableName
Name of the scheduled task.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.1.10.1.3
acsScheduledTasksTableStatus
When set to enabled, the task will be run according to the schedule
defined by acsScheduledTasksTableFrequency.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.10418.26.2.1.10.1.4
acsScheduledTasksTableFrequency
This object defines how often the task will be run.

When set to hourly(1), the task will be run every hour.

When set to daily(2), the task will be run every day at the time
specified by ac…
Enumerationr/w
Enumerated Values:
1hourly
2daily
3weekly
4monthly
.1.3.6.1.4.1.10418.26.2.1.10.1.5
acsScheduledTasksTableDay
Only used if acsScheduledTasksTableFrequency is set to weekly(3).
The task will be run every week on this day, at the time
specified by acsScheduledTasksTableTime.
Enumerationr/w
Enumerated Values:
1sunday
2monday
3tuesday
4wednesday
5thursday
6friday
7saturday
.1.3.6.1.4.1.10418.26.2.1.10.1.6
acsScheduledTasksTableDate
Only used if acsScheduledTasksTableFrequency is set to monthly(4).
The task will be run every month on this day, at the time
specified by acsScheduledTasksTableTime.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.1.10.1.7
acsScheduledTasksTableTime
The time of day the task will run. Format must be HH:MM.
OctetStringr/w
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.1.10.1.8
acsScheduledTasksTableLastStarted
The timestamp of the last time the task started running.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.1.10.1.9
acsScheduledTasksTableLastResult
The result of the last time the task was run.
OctetString
Constraints:
range: 0-256
.1.3.6.1.4.1.10418.26.2.1.10.1.10
acsScheduledTasksTableScript
The script command used by the task. Only used if
acsScheduledTasksTableType is set to custom(1).
OctetStringr/w
Constraints:
range: 0-128
.1.3.6.1.4.1.10418.26.2.1.10.1.11
acsScheduledTasksTableIpAddress
The IP address used by the cell-modem-ip task. Not used
by all tasks.
OctetStringr/w
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.1.10.1.12
.1.3.6.1.4.1.10418.26.2.2.2 · 1 row entry · 8 columns
This table contains the list of active sessions.
acsActiveSessionsTableEntry entry .1.3.6.1.4.1.10418.26.2.2.2.1
each entry has the information about the active session
Indexes
acsActiveSessionsTableIndex
Column Syntax OID
acsActiveSessionsTableIndex
A unique index representing an entry in this table.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.26.2.2.2.1.1
acsActiveSessionsTableUser
The name of the user that opens this session.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.2.2.1.2
acsActiveSessionsTableGroup
The name of the group that the user belongs to.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.2.2.1.3
acsActiveSessionsTableType
The session type.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.2.2.1.4
acsActiveSessionsTableConnection
Connection type.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.2.2.1.5
acsActiveSessionsTableSessionTime
Time of the session
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.2.2.1.6
acsActiveSessionsTableFrom
The source IP address of the session.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.2.2.1.7
acsActiveSessionsTableKill
A set value of killSession(2) will kill the session.
noAction(1) = always returned in a GET. Does nothing if SET.
killSession(2)= when SET the appliance immediately kills the session.
Enumerationr/w
Enumerated Values:
1noAction
2killSession
.1.3.6.1.4.1.10418.26.2.2.2.1.8
.1.3.6.1.4.1.10418.26.2.3.2 · 1 row entry · 23 columns
This table contains information about serial ports.
acsSerialPortTableEntry entry .1.3.6.1.4.1.10418.26.2.3.2.1
each entry has the information about specific serial port.
Indexes
acsSerialPortTableNumber
Column Syntax OID
acsSerialPortTableNumber
A unique index representing an entry in this table.
It is the number of the serial port. For AUX port,
the number will be the number of physical serial ports plus 1.
Integer32
Constraints:
range: 1-49
.1.3.6.1.4.1.10418.26.2.3.2.1.1
acsSerialPortTableDeviceName
The associated device name for the serial port.
OctetString
Constraints:
range: 0-25
.1.3.6.1.4.1.10418.26.2.3.2.1.2
acsSerialPortTableStatus
The status of the serial port:
disabled(1) = it was configured as disable.
idle(2) = there is not any session opened in this port.
inUse(3) = there is session(s) opened in this port.
Enumeration
Enumerated Values:
1disabled
2idle
3inUse
.1.3.6.1.4.1.10418.26.2.3.2.1.3
acsSerialPortTableName
Name associated with this serial port.
OctetString
Constraints:
range: 0-25
.1.3.6.1.4.1.10418.26.2.3.2.1.4
acsSerialPortTableProfile
Configured profile for this serial port.
Enumeration
Enumerated Values:
1casProfile
2tsProfile
3dialInProfile
4powerProfile
.1.3.6.1.4.1.10418.26.2.3.2.1.5
acsSerialPortTablePinOut
RJ45 Pin-out configured for this serial port.
SerialPortPinOut
Textual Convention: SerialPortPinOut Enumeration
Type Values:
1cyclades
2cisco
3rs422
4rs485
5auto
.1.3.6.1.4.1.10418.26.2.3.2.1.6
acsSerialPortTableComSpeed
Speed configured for this serial port.
SerialPortSpeed
Textual Convention: SerialPortSpeed Enumeration
Type Values:
300speed300bps
600speed600bps
1200speed1200bps
2400speed2400bps
4800speed4800bps
9600speed9600bps
19200speed19200bps
38400speed38400bps
57600speed57600bps
115200speed115200bps
230400speed230400bps
460800speed460800bps
.1.3.6.1.4.1.10418.26.2.3.2.1.7
acsSerialPortTableComParity
Parity configured for this serial port.
Enumeration
Enumerated Values:
1none
2odd
3even
.1.3.6.1.4.1.10418.26.2.3.2.1.8
acsSerialPortTableComDataSize
Data Size configured for this serial port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.3.2.1.9
acsSerialPortTableComStopBits
Number of Stop Bits configured for this serial port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.3.2.1.10
acsSerialPortTableComFlowControl
Flow Control configured for this serial port.
Enumeration
Enumerated Values:
1none
2hardware
3software
.1.3.6.1.4.1.10418.26.2.3.2.1.11
acsSerialPortTableSignalStateDTR
State of the DTR RS-232C signal.
SerialPortSignalState
Textual Convention: SerialPortSignalState Enumeration
Type Values:
1up
2down
.1.3.6.1.4.1.10418.26.2.3.2.1.12
acsSerialPortTableSignalStateDCD
State of the DCD RS-232C signal.
SerialPortSignalState
Textual Convention: SerialPortSignalState Enumeration
Type Values:
1up
2down
.1.3.6.1.4.1.10418.26.2.3.2.1.13
acsSerialPortTableSignalStateRTS
State of the RTS RS-232C signal.
SerialPortSignalState
Textual Convention: SerialPortSignalState Enumeration
Type Values:
1up
2down
.1.3.6.1.4.1.10418.26.2.3.2.1.14
acsSerialPortTableSignalStateCTS
State of the CTS RS-232C signal.
SerialPortSignalState
Textual Convention: SerialPortSignalState Enumeration
Type Values:
1up
2down
.1.3.6.1.4.1.10418.26.2.3.2.1.15
acsSerialPortTableTxBytes
The number of transmited bytes by the serial port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.3.2.1.16
acsSerialPortTableRxBytes
The number of received bytes by the serial port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.3.2.1.17
acsSerialPortTableFrameError
The number of frame error detected in the serial port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.3.2.1.18
acsSerialPortTableParityError
The number of parity error detected in the serial port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.3.2.1.19
acsSerialPortTableBreak
The number of break detected in the serial port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.3.2.1.20
acsSerialPortTableOverrun
The number of overrun error detected in the serial port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.3.2.1.21
acsSerialPortTableResetCounters
Resets counters for all statistics for this serial port.
Resets the countes for TxBytes, RxBytes, frame errors,
parity errors, breaks, and overrun errors.
Enumerationr/w
Enumerated Values:
1no-action
2resetCounters
.1.3.6.1.4.1.10418.26.2.3.2.1.22
acsSerialPortTableXcvrStatus
Activity status of the RS232 transceiver.
SerialPortSignalState
Textual Convention: SerialPortSignalState Enumeration
Type Values:
1up
2down
.1.3.6.1.4.1.10418.26.2.3.2.1.23
.1.3.6.1.4.1.10418.26.2.5.2 · 1 row entry · 5 columns
Information about each serial port thas has PDU connect.
acsPowerMgmtSerialTableEntry entry .1.3.6.1.4.1.10418.26.2.5.2.1
Information about each serial port thas has PDU connect.
Indexes
acsPowerMgmtSerialTableIndex
Column Syntax OID
acsPowerMgmtSerialTableIndex
The index of the register.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.2.1.1
acsPowerMgmtSerialTablePortNumber
The number of the serial port when the PDU is connected.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.2.1.2
acsPowerMgmtSerialTableDeviceName
The device name of this serial port.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.2.1.3
acsPowerMgmtSerialTableNumberPDUs
Total number of units connected in this serial port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.2.1.4
acsPowerMgmtSerialTableNumberUPS
Total number of UPS devices connected to this serial port.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.2.1.5
.1.3.6.1.4.1.10418.26.2.5.3 · 1 row entry · 67 columns
This table contains the list of detected PDUs.
acsPowerMgmtPDUTableEntry entry .1.3.6.1.4.1.10418.26.2.5.3.1
each entry has the information about the PDU.
Indexes
acsPowerMgmtPDUTablePortNumber acsPowerMgmtPDUTablePduIndex
Column Syntax OID
acsPowerMgmtPDUTablePortNumber
Number of serial port when the PDU is connected.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.1
acsPowerMgmtPDUTablePduIndex
A PDU position in the chain.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.2
acsPowerMgmtPDUTablePduId
PDU identification.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.3.1.3
acsPowerMgmtPDUTablePortName
Name of serial port when the PDU is connected.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.3.1.4
acsPowerMgmtPDUTableModel
Model of the PDU.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.3.1.5
acsPowerMgmtPDUTableVendor
Vendor of the PDU.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.3.1.6
acsPowerMgmtPDUTableFirmwareVersion
Version of the PDU firmware.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.3.1.7
acsPowerMgmtPDUTableNumberOfOutlets
Number of outlets of the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.8
acsPowerMgmtPDUTableCurrentNOS obsolete
Number of current sensors in the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.9
acsPowerMgmtPDUTableCurrent1Value obsolete
Current of the sensor 1 in this PDU unit in AMP.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.10
acsPowerMgmtPDUTableCurrent1Max obsolete
Maximum current of the sensor 1 in this PDU unit in AMP.
When the PDU does not have support for maximum value,
the value will be 0.
The value of this object is the actual current in
AMP * 10. You need to translate the r…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.11
acsPowerMgmtPDUTableCurrent2Value obsolete
Current of the sensor 2 in this PDU unit in AMP.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.12
acsPowerMgmtPDUTableCurrent2Max obsolete
Maximum current of the sensor 2 in this PDU unit in AMP.
When the PDU does not have support for maximum value,
the value will be 0.
The value of this object is the actual current in
AMP * 10. You need to translate the r…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.13
acsPowerMgmtPDUTableCurrent3Value obsolete
Current of the sensor 3 in this PDU unit in AMP.
The value of this object is the actual current in
AMP * 10. You need to translate the readed value
(Ex. : value is 5, the current is 0.5 AMP.)
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.14
acsPowerMgmtPDUTableCurrent3Max obsolete
Maximum current of the sensor 3 in this PDU unit in AMP.
When the PDU does not have support for maximum value,
the value will be 0.
The value of this object is the actual current in
AMP * 10. You need to translate the r…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.15
acsPowerMgmtPDUTableTemperatureNOS obsolete
Number of temperature sensors in the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.16
acsPowerMgmtPDUTableTemperature1Value obsolete
Temperature of this PM unit in Celsius degrees.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the te…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.17
acsPowerMgmtPDUTableTemperature1Max obsolete
Maximum temperature detected in this PM unit in Celsius degrees.
The value will be Zero when the PDU does not have support for maximum value.
The value of this object is the actual temperature in
degrees C * 10. You n…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.18
acsPowerMgmtPDUTableTemperature2Value obsolete
Temperature of this PM unit in Celsius degrees.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the te…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.19
acsPowerMgmtPDUTableTemperature2Max obsolete
Maximum temperature detected in this PM unit in Celsius degrees.
The value will be Zero when the PDU does not have support for maximum value.
The value of this object is the actual temperature in
degrees C * 10. You nee…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.20
acsPowerMgmtPDUTableTemperature3Value obsolete
Temperature of this PM unit in Celsius degrees.
The value of this object is the actual temperature in
degrees C * 10. You need to translate the readed value
(Ex. : value is 240, the temperature is 24 Celsius.)
If the te…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.21
acsPowerMgmtPDUTableTemperature3Max obsolete
Maximum temperature detected in this PM unit in Celsius degrees.
The value will be Zero when the PDU does not have support for maximum value.
The value of this object is the actual temperature in
degrees C * 10. You n…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.22
acsPowerMgmtPDUTableHumidityNOS obsolete
Number of humidity sensors in the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.23
acsPowerMgmtPDUTableHumidity1Value obsolete
Humidity of this PM unit .
If the humidity measurement is not installed this
value will be 0.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.24
acsPowerMgmtPDUTableHumidity1Max obsolete
Maximum humidity detected in this PM unit.
If the humidity measurement is not installed or the PDU does not have support for maximum value this
value will be 0.
Set with Zero value to clear the max. temperature.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.25
acsPowerMgmtPDUTableHumidity2Value obsolete
Humidity of this PM unit .
If the humidity measurement is not installed this
value will be 0.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.26
acsPowerMgmtPDUTableHumidity2Max obsolete
Maximum humidity detected in this PM unit.
If the humidity measurement is not installed or the PDU does not have support for maximum value this
value will be 0.
Set with Zero value to clear the max. temperature.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.27
acsPowerMgmtPDUTableHumidity3Value obsolete
Humidity of this PM unit .
If the humidity measurement is not installed this
value will be 0.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.28
acsPowerMgmtPDUTableHumidity3Max obsolete
Maximum humidity detected in this PM unit.
If the humidity measurement is not installed or the PDU does not have support for maximum value this
value will be 0.
Set with Zero value to clear the max. temperature.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.29
acsPowerMgmtPDUTableVoltageNOS obsolete
Number of voltage sensors in the PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.30
acsPowerMgmtPDUTableVoltage1Value obsolete
Voltage of this sensor in this PDU unit.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.31
acsPowerMgmtPDUTableVoltage1Max obsolete
Maximum voltage of this sensor in this PDU unit.
Set with Zero value to clear the maximum voltage.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.32
acsPowerMgmtPDUTableVoltage2Value obsolete
Voltage of this sensor in this PDU unit.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.33
acsPowerMgmtPDUTableVoltage2Max obsolete
Maximum voltage of this sensor in this PDU unit.
Set with Zero value to clear the maximum voltage.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.34
acsPowerMgmtPDUTableVoltage3Value obsolete
Voltage of this sensor in this PDU unit.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.35
acsPowerMgmtPDUTableVoltage3Max obsolete
Maximum voltage of this sensor in this PDU unit.
Set with Zero value to clear the maximum voltage.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.36
acsPowerMgmtPDUTableNumberOfPhases
Number of phases of this PDU unit.
Enumeration
Enumerated Values:
0single-phase
3three-phase
.1.3.6.1.4.1.10418.26.2.5.3.1.37
acsPowerMgmtPDUTableNumberOfBanks
Number of banks of this PDU unit.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.38
acsPowerMgmtPDUTableCurrentValue
Actual value of current sensor in this PDU.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.39
acsPowerMgmtPDUTableCurrentMax
Max detected value of current sensor in this PDU.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.40
acsPowerMgmtPDUTableCurrentMin
Min detected value of current sensor in this PDU.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.41
acsPowerMgmtPDUTableCurrentAvg
Average value for current sensor in this PDU.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.42
acsPowerMgmtPDUTableCurrentReset
Reset max, min and avg values of current.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.3.1.43
acsPowerMgmtPDUTableVoltageType
Type of voltage values.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2read
.1.3.6.1.4.1.10418.26.2.5.3.1.44
acsPowerMgmtPDUTableVoltageValue
Actual value of voltage sensor in this PDU unit.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.45
acsPowerMgmtPDUTableVoltageMax
Max detected value of voltage sensor in this PDU unit.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.46
acsPowerMgmtPDUTableVoltageMin
Min detected value of voltage sensor in this PDU unit.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.47
acsPowerMgmtPDUTableVoltageAvg
Average value for voltage sensor in this PDU unit.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.48
acsPowerMgmtPDUTableVoltageReset
Reset max, min and avg values of voltage.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.3.1.49
acsPowerMgmtPDUTablePowerType
Type of power consumption values.( W x 10 )
Enumeration
Enumerated Values:
0none-sensor
1estimated
2read
.1.3.6.1.4.1.10418.26.2.5.3.1.50
acsPowerMgmtPDUTablePowerValue
Actual value of power consumption in this PDU unit.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.51
acsPowerMgmtPDUTablePowerMax
Max detected value of power consumption in this PDU unit.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.52
acsPowerMgmtPDUTablePowerMin
Min detected value of power consumption in this PDU unit.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.53
acsPowerMgmtPDUTablePowerAvg
Average value for power consumption in this PDU unit.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.54
acsPowerMgmtPDUTablePowerReset
Reset max, min and avg values of power consumption.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.3.1.55
acsPowerMgmtPDUTablePowerFactorType
Type of power factor values.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2read
.1.3.6.1.4.1.10418.26.2.5.3.1.56
acsPowerMgmtPDUTablePowerFactorValue
Actual value of power factor in this PDU unit.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.57
acsPowerMgmtPDUTablePowerFactorMax
Max detected value of power factor in this PDU unit.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.58
acsPowerMgmtPDUTablePowerFactorMin
Min detected value of power factor in this PDU unit.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.59
acsPowerMgmtPDUTablePowerFactorAvg
Average value for power factor in this PDU unit.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.60
acsPowerMgmtPDUTablePowerFactorReset
Reset max, min and avg values of power factor.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.3.1.61
acsPowerMgmtPDUTableAlarm
Show the PDU alarm status.
Enumeration
Enumerated Values:
1normal
2blow-fuse
3hw-ocp
4high-critical
5high-warning
6low-warning
7low-critical
.1.3.6.1.4.1.10418.26.2.5.3.1.62
acsPowerMgmtPDUTableEnvSensors
Number of environmental sensor in this PDU.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.3.1.63
acsPowerMgmtPDUTableAgentSerialNumber
Serial number of the agent.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.3.1.64
acsPowerMgmtPDUTablePduModelNumber
Model number of the PDU.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.3.1.65
acsPowerMgmtPDUTablePduSerialNumber
Serial number of the PDU.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.3.1.66
acsPowerMgmtPDUTablePduPartNumber
Part number of the PDU.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.3.1.67
.1.3.6.1.4.1.10418.26.2.5.5 · 1 row entry · 8 columns
This table contains the information about outlets.
acsPowerMgmtOutletsTableEntry entry .1.3.6.1.4.1.10418.26.2.5.5.1
each entry has the information about the outlet.
Indexes
acsPowerMgmtOutletsTablePortNumber acsPowerMgmtOutletsTablePduNumber acsPowerMgmtOutletsTableNumber
Column Syntax OID
acsPowerMgmtOutletsTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.5.1.1
acsPowerMgmtOutletsTablePduNumber
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.5.1.2
acsPowerMgmtOutletsTableNumber
Number of the outlet in the PDU.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.5.1.3
acsPowerMgmtOutletsTableName
Name of the outlet.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.5.1.4
acsPowerMgmtOutletsTableStatus
Status of the outlet.
Enumeration
Enumerated Values:
1off
2on
.1.3.6.1.4.1.10418.26.2.5.5.1.5
acsPowerMgmtOutletsTablePowerControl
A set value of power*(2-6) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
powerOn(2) = when SET the power On command is sent to PDU.
powerOff(3) = when SET the power Off command …
Enumerationr/w
Enumerated Values:
1noAction
2powerOn
3powerOff
4powerCycle
5powerLock
6powerUnlock
.1.3.6.1.4.1.10418.26.2.5.5.1.6
acsPowerMgmtOutletsTablePortName
Serial Port Name where the PDU is connected.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.5.1.7
acsPowerMgmtOutletsTablePduId
PDU identification.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.5.1.8
.1.3.6.1.4.1.10418.26.2.5.7 · 1 row entry · 4 columns
This table contains the information about group of outlets.
acsPowerMgmtGroupTableEntry entry .1.3.6.1.4.1.10418.26.2.5.7.1
each entry has the information about group of outlets.
Indexes
acsPowerMgmtGroupTableIndex
Column Syntax OID
acsPowerMgmtGroupTableIndex
Index of the group.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.26.2.5.7.1.1
acsPowerMgmtGroupTableName
Name of the group of outlets.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.7.1.2
acsPowerMgmtGroupTableStatus
Status of the group of outlet.
Enumeration
Enumerated Values:
1off
2on
.1.3.6.1.4.1.10418.26.2.5.7.1.3
acsPowerMgmtGroupTablePowerControl
A set value of power*(2-6) will send command to PDU.
noAction(1) = always returned in a GET. Does nothing if SET.
powerOn(2) = when SET the power On command is sent to PDU.
powerOff(3) = when SET the power Off command …
Enumerationr/w
Enumerated Values:
1noAction
2powerOn
3powerOff
4powerCycle
.1.3.6.1.4.1.10418.26.2.5.7.1.4
.1.3.6.1.4.1.10418.26.2.5.8 · 1 row entry · 30 columns
This table contains data monitoring of each detected phase.
acsPowerMgmtPhasesTableEntry entry .1.3.6.1.4.1.10418.26.2.5.8.1
each entry has the data monitoring about phases.
Indexes
acsPowerMgmtPhasesTablePortNumber acsPowerMgmtPhasesTablePduIndex acsPowerMgmtPhasesTablePhaseIndex
Column Syntax OID
acsPowerMgmtPhasesTablePortNumber
Number of serial port when the PDU is connected.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.1
acsPowerMgmtPhasesTablePduIndex
A PDU position in the chain.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.2
acsPowerMgmtPhasesTablePhaseIndex
phase index in the PDU.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.3
acsPowerMgmtPhasesTablePhaseName
phase name in the PDU.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.8.1.4
acsPowerMgmtPhasesTablePduId
PDU identification.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.8.1.5
acsPowerMgmtPhasesTablePortName
Name of serial port when the PDU is connected.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.8.1.6
acsPowerMgmtPhasesTableCurrentValue
Actual value of current sensor in this phase.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.7
acsPowerMgmtPhasesTableCurrentMax
Max detected value of current sensor in this phase.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.8
acsPowerMgmtPhasesTableCurrentMin
Min detected value of current sensor in this phase.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.9
acsPowerMgmtPhasesTableCurrentAvg
Average value for current sensor in this phase.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.10
acsPowerMgmtPhasesTableCurrentReset
Reset max, min and avg values of current.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.8.1.11
acsPowerMgmtPhasesTableVoltageType
Type of voltage values.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2read
.1.3.6.1.4.1.10418.26.2.5.8.1.12
acsPowerMgmtPhasesTableVoltageValue
Actual value of voltage sensor in this phase.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.13
acsPowerMgmtPhasesTableVoltageMax
Max detected value of voltage sensor in this phase.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.14
acsPowerMgmtPhasesTableVoltageMin
Min detected value of voltage sensor in this phase.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.15
acsPowerMgmtPhasesTableVoltageAvg
Average value for voltage sensor in this phase.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.16
acsPowerMgmtPhasesTableVoltageReset
Reset max, min and avg values of voltage.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.8.1.17
acsPowerMgmtPhasesTablePowerType
Type of power consumption values.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2read
.1.3.6.1.4.1.10418.26.2.5.8.1.18
acsPowerMgmtPhasesTablePowerValue
Actual value of power consumption in this phase.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.19
acsPowerMgmtPhasesTablePowerMax
Max detected value of power consumption in this phase.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.20
acsPowerMgmtPhasesTablePowerMin
Min detected value of power consumption in this phase.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.21
acsPowerMgmtPhasesTablePowerAvg
Average value for power consumption in this phase.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.22
acsPowerMgmtPhasesTablePowerReset
Reset max, min and avg values of power consumption.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.8.1.23
acsPowerMgmtPhasesTablePowerFactorType
Type of power factor values.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2read
.1.3.6.1.4.1.10418.26.2.5.8.1.24
acsPowerMgmtPhasesTablePowerFactorValue
Actual value of power factor in this phase.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.25
acsPowerMgmtPhasesTablePowerFactorMax
Max detected value of power factor in this phase.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.26
acsPowerMgmtPhasesTablePowerFactorMin
Min detected value of power factor in this phase.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.27
acsPowerMgmtPhasesTablePowerFactorAvg
Average value for power factor in this phase.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.8.1.28
acsPowerMgmtPhasesTablePowerFactorReset
Reset max, min and avg values of power factor.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.8.1.29
acsPowerMgmtPhasesTableAlarm
Show the phase alarm status.
Enumeration
Enumerated Values:
1normal
2blow-fuse
3hw-ocp
4high-critical
5high-warning
6low-warning
7low-critical
.1.3.6.1.4.1.10418.26.2.5.8.1.30
.1.3.6.1.4.1.10418.26.2.5.9 · 1 row entry · 30 columns
This table contains data monitoring of each detected bank.
acsPowerMgmtBanksTableEntry entry .1.3.6.1.4.1.10418.26.2.5.9.1
each entry has the data monitoring about bank.
Indexes
acsPowerMgmtBanksTablePortNumber acsPowerMgmtBanksTablePduIndex acsPowerMgmtBanksTableBankIndex
Column Syntax OID
acsPowerMgmtBanksTablePortNumber
Number of serial port when the PDU is connected.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.1
acsPowerMgmtBanksTablePduIndex
A PDU position in the chain.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.2
acsPowerMgmtBanksTableBankIndex
Bank index in the PDU.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.3
acsPowerMgmtBanksTableBankName
Bank name in the PDU.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.9.1.4
acsPowerMgmtBanksTablePduId
PDU identification.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.9.1.5
acsPowerMgmtBanksTablePortName
Name of serial port when the PDU is connected.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.9.1.6
acsPowerMgmtBanksTableCurrentValue
Actual value of current sensor in this bank.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.7
acsPowerMgmtBanksTableCurrentMax
Max detected value of current sensor in this bank.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.8
acsPowerMgmtBanksTableCurrentMin
Min detected value of current sensor in this bank.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.9
acsPowerMgmtBanksTableCurrentAvg
Average value for current sensor in this bank.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.10
acsPowerMgmtBanksTableCurrentReset
Reset max, min and avg values of current.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.9.1.11
acsPowerMgmtBanksTableVoltageType
Type of voltage values.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2read
.1.3.6.1.4.1.10418.26.2.5.9.1.12
acsPowerMgmtBanksTableVoltageValue
Actual value of voltage sensor in this bank.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.13
acsPowerMgmtBanksTableVoltageMax
Max detected value of voltage sensor in this bank.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.14
acsPowerMgmtBanksTableVoltageMin
Min detected value of voltage sensor in this bank.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.15
acsPowerMgmtBanksTableVoltageAvg
Average value for voltage sensor in this bank.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.16
acsPowerMgmtBanksTableVoltageReset
Reset max, min and avg values of voltage.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.9.1.17
acsPowerMgmtBanksTablePowerType
Type of power consumption values.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2read
.1.3.6.1.4.1.10418.26.2.5.9.1.18
acsPowerMgmtBanksTablePowerValue
Actual value of power consumption in this bank.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.19
acsPowerMgmtBanksTablePowerMax
Max detected value of power consumption in this bank.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.20
acsPowerMgmtBanksTablePowerMin
Min detected value of power consumption in this bank.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.21
acsPowerMgmtBanksTablePowerAvg
Average value for power consumption in this bank.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.22
acsPowerMgmtBanksTablePowerReset
Reset max, min and avg values of power consumption.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.9.1.23
acsPowerMgmtBanksTablePowerFactorType
Type of power factor values.
Enumeration
Enumerated Values:
0none-sensor
1estimated
2read
.1.3.6.1.4.1.10418.26.2.5.9.1.24
acsPowerMgmtBanksTablePowerFactorValue
Actual value of power factor in this bank.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.25
acsPowerMgmtBanksTablePowerFactorMax
Max detected value of power factor in this bank.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.26
acsPowerMgmtBanksTablePowerFactorMin
Min detected value of power factor in this bank.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.27
acsPowerMgmtBanksTablePowerFactorAvg
Average value for power factor in this bank.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.9.1.28
acsPowerMgmtBanksTablePowerFactorReset
Reset max, min and avg values of power factor.
Enumerationr/w
Enumerated Values:
1no-action
2reset
.1.3.6.1.4.1.10418.26.2.5.9.1.29
acsPowerMgmtBanksTableAlarm
Show the bank alarm status.
Enumeration
Enumerated Values:
1normal
2blow-fuse
3hw-ocp
4high-critical
5high-warning
6low-warning
7low-critical
.1.3.6.1.4.1.10418.26.2.5.9.1.30
.1.3.6.1.4.1.10418.26.2.5.10 · 1 row entry · 10 columns
This table contains data monitoring of each detected environmental sensor.
acsPowerMgmtEnvMonTableEntry entry .1.3.6.1.4.1.10418.26.2.5.10.1
each entry has the data monitoring about environmental sensors.
Indexes
acsPowerMgmtEnvMonTablePortNumber acsPowerMgmtEnvMonTablePduIndex acsPowerMgmtEnvMonTableIndex
Column Syntax OID
acsPowerMgmtEnvMonTablePortNumber
Number of serial port when the PDU is connected.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.10.1.1
acsPowerMgmtEnvMonTablePduIndex
A PDU position in the chain.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.26.2.5.10.1.2
acsPowerMgmtEnvMonTableIndex
envmon sensor index.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.26.2.5.10.1.3
acsPowerMgmtEnvMonTableName
envmon sensor name.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.10.1.4
acsPowerMgmtEnvMonTablePduId
PDU identification.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.10.1.5
acsPowerMgmtEnvMonTablePortName
Name of serial port when the PDU is connected.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.10.1.6
acsPowerMgmtEnvMonTableType
The type of environmental monitor.
Enumeration
Enumerated Values:
1temp-internal
2temperature
3humidity
4air-flow
5smoke
6dry-contact
7water-level
8motion
9unplugged
10unknown
11air-pressure
12vibration
13vibration-contact
14leak
15door-contact
16dewpoint
17ad-converter
18voltage
19current
.1.3.6.1.4.1.10418.26.2.5.10.1.7
acsPowerMgmtEnvMonTableStatus
Status of digital sensors:
Dry-Contact, Water level, Smoke sensor, Motion sensor, Door-Contact, Leak, A2D.
For Door-Contact, normal(1) = closed, triggered(2) = opened.
For A2D, normal(1) = low, triggered(2) = high.
For …
Enumeration
Enumerated Values:
1normal
2triggered
3not-applicable
4leak
5cableFault
.1.3.6.1.4.1.10418.26.2.5.10.1.8
acsPowerMgmtEnvMonTableValue
Detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.10.1.9
acsPowerMgmtEnvMonTableMaxValue
Max detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu.
Voltage VDC x 100. Current x 100.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.10.1.10
.1.3.6.1.4.1.10418.26.2.5.11 · 1 row entry · 24 columns
This table contains the information about data monitoring of outlets.
acsPowerMgmtOutElecMonTableEntry entry .1.3.6.1.4.1.10418.26.2.5.11.1
each entry has the information about the outlet.
Indexes
acsPowerMgmtOutElecMonTablePortNumber acsPowerMgmtOutElecMonTablePduNumber acsPowerMgmtOutElecMonTableNumber
Column Syntax OID
acsPowerMgmtOutElecMonTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.1
acsPowerMgmtOutElecMonTablePduNumber
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.2
acsPowerMgmtOutElecMonTableNumber
Number of the outlet in the PDU.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.3
acsPowerMgmtOutElecMonTableCurrentValue
Actual value of outlet current sensor.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.4
acsPowerMgmtOutElecMonTableCurrentMax
Max detected value of outlet current sensor.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.5
acsPowerMgmtOutElecMonTableCurrentMin
Min detected value of outlet current sensor.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.6
acsPowerMgmtOutElecMonTableCurrentAvg
Average value for outlet current sensor.( A x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.7
acsPowerMgmtOutElecMonTableCurrentReset
Reset max, min and avertage values of outlet current.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.26.2.5.11.1.8
acsPowerMgmtOutElecMonTablePowerValue
Actual value of outlet power comsumption sensor.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.9
acsPowerMgmtOutElecMonTablePowerMax
Max detected value of outlet power comsumption sensor.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.10
acsPowerMgmtOutElecMonTablePowerMin
Min detected value of outlet power comsumption sensor.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.11
acsPowerMgmtOutElecMonTablePowerAvg
Average value for outlet power comsumption sensor.( W x 10 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.12
acsPowerMgmtOutElecMonTablePowerReset
Reset max, min and avertage values of outlet power comsumption.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.26.2.5.11.1.13
acsPowerMgmtOutElecMonTableVoltageValue
Actual value of outlet voltage sensor.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.14
acsPowerMgmtOutElecMonTableVoltageMax
Max detected value of outlet voltage sensor.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.15
acsPowerMgmtOutElecMonTableVoltageMin
Min detected value of outlet voltage sensor.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.16
acsPowerMgmtOutElecMonTableVoltageAvg
Average value for outlet voltage sensor.( V )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.17
acsPowerMgmtOutElecMonTableVoltageReset
Reset max, min and avertage values of outlet voltage.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.26.2.5.11.1.18
acsPowerMgmtOutElecMonTablePowerFactorValue
Actual value of outlet power-factor sensor.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.19
acsPowerMgmtOutElecMonTablePowerFactorMax
Max detected value of outlet power-factor sensor.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.20
acsPowerMgmtOutElecMonTablePowerFactorMin
Min detected value of outlet power-factor sensor.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.21
acsPowerMgmtOutElecMonTablePowerFactorAvg
Average value for outlet power-factor sensor.( PF x 100 )
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.11.1.22
acsPowerMgmtOutElecMonTablePowerFactorReset
Reset max, min and avertage values of outlet power-factor.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.26.2.5.11.1.23
acsPowerMgmtOutElecMonTableAlarm
Show the outlet alarm status.
Enumeration
Enumerated Values:
1normal
2blow-fuse
3hw-ocp
4high-critical
5high-warning
6low-warning
7low-critical
.1.3.6.1.4.1.10418.26.2.5.11.1.24
.1.3.6.1.4.1.10418.26.2.5.12 · 1 row entry · 24 columns
This table contains the list of detected UPSs.
acsPowerMgmtUPSTableEntry entry .1.3.6.1.4.1.10418.26.2.5.12.1
Each entry has the information about the UPS.
Indexes
acsPowerMgmtUPSTablePortNumber acsPowerMgmtUPSTableUpsIndex
Column Syntax OID
acsPowerMgmtUPSTablePortNumber
Number of serial port when the UPS is connected.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.12.1.1
acsPowerMgmtUPSTableUpsIndex
A UPS position in the chain.
IF-MIBInterfaceIndexOrZero
Textual Convention: IF-MIBInterfaceIndexOrZero Integer32
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.10418.26.2.5.12.1.2
acsPowerMgmtUPSTableUpsId
UPS identification.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.3
acsPowerMgmtUPSTablePortName
Name of serial port or IP address if network device
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.4
acsPowerMgmtUPSTableModel
Model of the UPS.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.5
acsPowerMgmtUPSTableVendor
Vendor of the UPS.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.6
acsPowerMgmtUPSTableFirmwareVersion
Version of the UPS firmware.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.7
acsPowerMgmtUPSTableAgentFirmwareVersion
Firmware version of the agent card.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.8
acsPowerMgmtUPSTableSystemStatus
System Status of the UPS.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.9
acsPowerMgmtUPSTableInputBlackOutCount
The number of occurrences, since the last reset, where the input
was not qualified to provide power to the system.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.12.1.10
acsPowerMgmtUPSTableInputBrownOutCount
The number of occurrences, since the last reset, where the system
input voltage has fallen below a pre-determined threshold for a
specified amount of time.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.12.1.11
acsPowerMgmtUPSTableInletAirTemperature
Temperature of the inlet air.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.12
acsPowerMgmtUPSTableNumberOutletGroups
The number of Outlet Groups on this UPS
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.12.1.13
acsPowerMgmtUPSTableUPSSerialNumber
System serial number.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.14
acsPowerMgmtUPSTableUPSManufactureDate
Manufacturing date of the system.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.15
acsPowerMgmtUPSTableAutoRestartDelay
If power is lost, the control will delay this amount of
time after power is restored before restarting the unit.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.5.12.1.16
acsPowerMgmtUPSTableAutoRestartControl
When set to enabled, the UPS will automatically restart the load
when utility power is restored after a battery discharge.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.10418.26.2.5.12.1.17
acsPowerMgmtUPSTableAudibleAlarmControl
Audible alarm control.
Enumerationr/w
Enumerated Values:
1off
2on
.1.3.6.1.4.1.10418.26.2.5.12.1.18
acsPowerMgmtUPSTableSilenceAlarm
Silence audible alarm.
Enumerationr/w
Enumerated Values:
0noAction
1silenceAlarm
.1.3.6.1.4.1.10418.26.2.5.12.1.19
acsPowerMgmtUPSTableInverterState
Inverter on/off state.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.20
acsPowerMgmtUPSTableDCConverterStatus
The operating state of the dc converter.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.21
acsPowerMgmtUPSTableShutdownReason
The reason for the most recent shutdown.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.22
acsPowerMgmtUPSTableUPSTopology
UPS Topology.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.23
acsPowerMgmtUPSTableBypassInverterInputConfig
Input source configuration for the bypass and inverter.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.12.1.24
.1.3.6.1.4.1.10418.26.2.5.13 · 1 row entry · 18 columns
This table contains the information about UPS inputs.
acsPowerMgmtUPSInputTableEntry entry .1.3.6.1.4.1.10418.26.2.5.13.1
each entry has the information about the UPS inputs.
Indexes
acsPowerMgmtUPSInputTablePortNumber acsPowerMgmtUPSInputTableUpsIndex
Column Syntax OID
acsPowerMgmtUPSInputTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.13.1.1
acsPowerMgmtUPSInputTableUpsIndex
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.13.1.2
acsPowerMgmtUPSInputTableFrequency
Input Frequency.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.3
acsPowerMgmtUPSInputTableRMSVoltageL1N
RMS Voltage L1-N.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.4
acsPowerMgmtUPSInputTableRMSVoltageL1L2
RMS Voltage L1L2.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.5
acsPowerMgmtUPSInputTableRMSVoltageL2N
RMS Voltage L2N.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.6
acsPowerMgmtUPSInputTableRMSCurrentL1
RMS Current for L1.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.7
acsPowerMgmtUPSInputTableRMSCurrentL2
RMS Current for L2.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.8
acsPowerMgmtUPSInputTableMaxVoltageL1N
Input Max Voltage measurement for Line L1-N since the last reset.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.9
acsPowerMgmtUPSInputTableMinVoltageL1N
Input Min Voltage measurement for Line L1-N since the last reset.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.10
acsPowerMgmtUPSInputTableMaxVoltageL2N
Input Max Voltage measurement for Line L2-N since the last reset.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.11
acsPowerMgmtUPSInputTableMinVoltageL2N
Input Min Voltage measurement for Line L1-N since the last reset.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.12
acsPowerMgmtUPSInputTableNominalVoltage
Input nominal voltage.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.13
acsPowerMgmtUPSInputTableNominalFrequency
Input nominal frequency.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.14
acsPowerMgmtUPSInputTableNominalCurrent
Input nominal current.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.15
acsPowerMgmtUPSInputTableEnergy
Input Energy.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.16
acsPowerMgmtUPSInputTablePowerFactorL1N
Input Power Factor for Line 1.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.17
acsPowerMgmtUPSInputTablePowerFactorL2N
Input Power Factor for Line 2.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.13.1.18
.1.3.6.1.4.1.10418.26.2.5.14 · 1 row entry · 9 columns
This table contains the information about UPS bypass.
acsPowerMgmtUPSBypassTableEntry entry .1.3.6.1.4.1.10418.26.2.5.14.1
each entry has the information about the UPS bypass.
Indexes
acsPowerMgmtUPSBypassTablePortNumber acsPowerMgmtUPSBypassTableUpsIndex
Column Syntax OID
acsPowerMgmtUPSBypassTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.14.1.1
acsPowerMgmtUPSBypassTableUpsIndex
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.14.1.2
acsPowerMgmtUPSBypassTableRMSVoltageL1N
RMS Voltage L1N.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.14.1.3
acsPowerMgmtUPSBypassTableRMSVoltageL1L2
RMS Voltage L1L2.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.14.1.4
acsPowerMgmtUPSBypassTableRMSVoltageL2N
RMS Voltage L2N.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.14.1.5
acsPowerMgmtUPSBypassTableRMSCurrent
RMS Current.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.14.1.6
acsPowerMgmtUPSBypassTableRMSCurrentL2
RMS Current.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.14.1.7
acsPowerMgmtUPSBypassTableInputFrequency
Bypass Input Frequency.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.14.1.8
acsPowerMgmtUPSBypassTableNominalVoltage
Bypass Nominal Voltage.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.14.1.9
.1.3.6.1.4.1.10418.26.2.5.15 · 1 row entry · 22 columns
This table contains the information about UPS battery.
acsPowerMgmtUPSBatteryTableEntry entry .1.3.6.1.4.1.10418.26.2.5.15.1
each entry has the information about the UPS bypass.
Indexes
acsPowerMgmtUPSBatteryTablePortNumber acsPowerMgmtUPSBatteryTableUpsIndex
Column Syntax OID
acsPowerMgmtUPSBatteryTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.15.1.1
acsPowerMgmtUPSBatteryTableUpsIndex
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.15.1.2
acsPowerMgmtUPSBatteryTableDCBusVoltage
DC Bus Voltage
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.3
acsPowerMgmtUPSBatteryTableTimeRemaining
The calculated available time on battery.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.4
acsPowerMgmtUPSBatteryTablePercentageCharge
Battery Percentage Charge.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.5
acsPowerMgmtUPSBatteryTableChargeStatus
Battery Charge Status.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.6
acsPowerMgmtUPSBatteryTableLowBatteryWarningTime
When battery time remaining falls to, or below, this value
(minutes) the low battery alarm is activated.
Integer32r/w
Constraints:
range: 2-30
.1.3.6.1.4.1.10418.26.2.5.15.1.7
acsPowerMgmtUPSBatteryTableTestResult
The outcome of the previous battery test.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.8
acsPowerMgmtUPSBatteryTableDCBusNominalVoltage
Battery DC Bus Nominal Voltage.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.9
acsPowerMgmtUPSBatteryTableNominalBatteryCapacity
Nominal Battery Capacity.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.10
acsPowerMgmtUPSBatteryTableBatteryFloatVoltage
Battery Float Voltage.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.11
acsPowerMgmtUPSBatteryTableBatteryCabinetType
Battery Cabinet Type.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.12
acsPowerMgmtUPSBatteryTableBatteryNumberOfEBC
Number of Extended Battery Cabinets installed.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.13
acsPowerMgmtUPSBatteryTableBatteryRating
Battery Rating.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.14
acsPowerMgmtUPSBatteryTableBatteryDischargeTime
Time on battery operation for this discharge
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.15
acsPowerMgmtUPSBatteryTableBatteryChargeCompensating
Battery charge algorithm changed due to battery temperature.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.16
acsPowerMgmtUPSBatteryTableBatteryChargerState
Battery charger state.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.17
acsPowerMgmtUPSBatteryTableStartBatteryTest
Command to initate a manual battery test.
Enumerationr/w
Enumerated Values:
1noAction
2start
.1.3.6.1.4.1.10418.26.2.5.15.1.18
acsPowerMgmtUPSBatteryTableBatteryStatus
Battery Status.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.19
acsPowerMgmtUPSBatteryTableBatteryTotalDischargeTime
Cumulative battery discharge time.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.20
acsPowerMgmtUPSBatteryTableBatteryDischargeCount
Total number of battery discharges.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.21
acsPowerMgmtUPSBatteryTableBatteryCurrent
Current at the battery input terminals. In charging mode,
the current will be a positive value. In discharging mode,
the current will be a negative value.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.15.1.22
.1.3.6.1.4.1.10418.26.2.5.16 · 1 row entry · 31 columns
This table contains the information about UPS output.
acsPowerMgmtUPSOutputTableEntry entry .1.3.6.1.4.1.10418.26.2.5.16.1
Each entry has the information about the UPS output.
Indexes
acsPowerMgmtUPSOutputTablePortNumber acsPowerMgmtUPSOutputTableUpsIndex
Column Syntax OID
acsPowerMgmtUPSOutputTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.16.1.1
acsPowerMgmtUPSOutputTableUpsIndex
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.16.1.2
acsPowerMgmtUPSOutputTableApparentPower
DC Bus Voltage
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.3
acsPowerMgmtUPSOutputTableFrequency
Output frequency.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.4
acsPowerMgmtUPSOutputTablePercentPower
The system output power as a percentage of the rated capacity.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.5
acsPowerMgmtUPSOutputTablePercentPowerL1
The system output power on line L1 as a percentage of the rated capacity.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.6
acsPowerMgmtUPSOutputTablePercentPowerL2
The system output power on line L2 as a percentage of the rated capacity.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.7
acsPowerMgmtUPSOutputTablePower
The sum total power of all system output phases.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.8
acsPowerMgmtUPSOutputTableRMSCurrentL1
System output RMS current for line L1.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.9
acsPowerMgmtUPSOutputTableRMSCurrentL2
System output RMS current for line L2.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.10
acsPowerMgmtUPSOutputTableRMSVoltageL1N
The system output RMS voltage.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.11
acsPowerMgmtUPSOutputTableRMSVoltageL2N
The system output RMS voltage.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.12
acsPowerMgmtUPSOutputTableRMSVoltageL1L2
The system output RMS voltage.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.13
acsPowerMgmtUPSOutputOffDelay
Turns the UPS output off after the number of seconds specified.
When a value is written to this object the output will be turned
off after the specified time has elapsed and the output will
remain off.
Integer32r/w
Constraints:
range: 0-300
.1.3.6.1.4.1.10418.26.2.5.16.1.14
acsPowerMgmtUPSOutputOnDelay
Turns the UPS output on after the number of seconds specified.
When a value is written to this object the output will be turned
on after the specified time has elapsed.
Integer32r/w
Constraints:
range: 0-300
.1.3.6.1.4.1.10418.26.2.5.16.1.15
acsPowerMgmtUPSOutputCycleDelay
Turns the UPS off and then back on after the number of seconds specified.
When a value is written to this object the output will turned off immediately
and then turned back on after the specified time has elapsed.
Integer32r/w
Constraints:
range: 0-300
.1.3.6.1.4.1.10418.26.2.5.16.1.16
acsPowerMgmtUPSOutputTableMaxVoltageL1
The maximum system output voltage measurement for line 1 since the last reset.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.17
acsPowerMgmtUPSOutputTableMinVoltageL1
The minimum system output voltage measurement for line 1 since the last reset.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.18
acsPowerMgmtUPSOutputTableMaxVoltageL2
The maximum system output voltage measurement for line 21 since the last reset.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.19
acsPowerMgmtUPSOutputTableMinVoltageL2
The minimum system output voltage measurement for line 2 since the last reset.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.20
acsPowerMgmtUPSOutputTableNominalVoltage
The nominal (or rated) system output voltage.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.21
acsPowerMgmtUPSOutputTablePowerNominalFrequency
The nominal (or rated) system output frequency.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.22
acsPowerMgmtUPSOutputTablePowerApparentPowerRating
Output apparent power rating.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.23
acsPowerMgmtUPSOutputTablePowerNominalPowerFactor
The nominal (or rated) system power factor.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.24
acsPowerMgmtUPSOutputTablePowerPowerFactorCorrection
The state of the power factor correction circuitry of the system.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.25
acsPowerMgmtUPSOutputTablePowerL1
The system output power on line 1.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.26
acsPowerMgmtUPSOutputTablePowerL2
The system output power on line 2.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.27
acsPowerMgmtUPSOutputTableApparentPowerL1
The system output apparent power on line 1.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.28
acsPowerMgmtUPSOutputTableApparentPowerL2
The system output apparent power on line 2.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.29
acsPowerMgmtUPSOutputTablePowerFactorL1
The system output power factor on line 1.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.30
acsPowerMgmtUPSOutputTablePowerFactorL2
The system output power factor on line 2.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.16.1.31
.1.3.6.1.4.1.10418.26.2.5.17 · 1 row entry · 4 columns
This table contains the information about UPS ECO Mode.
acsPowerMgmtUPSEcoModeTableEntry entry .1.3.6.1.4.1.10418.26.2.5.17.1
each entry has the information about the UPS ECO Mode.
Indexes
acsPowerMgmtUPSBypassTablePortNumber acsPowerMgmtUPSBypassTableUpsIndex
Column Syntax OID
acsPowerMgmtUPSEcoModeTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.17.1.1
acsPowerMgmtUPSEcoModeTableUpsIndex
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.17.1.2
acsPowerMgmtUPSEcoModeTableStatus
Current ECO Mode Status.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.17.1.3
acsPowerMgmtUPSEcoModeTableStateControl
Enable or disable ECO mode.
Enumerationr/w
Enumerated Values:
1noAction
2enable
3disable
.1.3.6.1.4.1.10418.26.2.5.17.1.4
.1.3.6.1.4.1.10418.26.2.5.18 · 1 row entry · 6 columns
This table contains the UPS Outlet Group Information.
acsPowerMgmtUPSOutletGroupTableEntry entry .1.3.6.1.4.1.10418.26.2.5.18.1
Each entry has the UPS outlet group information.
Indexes
acsPowerMgmtUPSOutletGroupTablePortNumber acsPowerMgmtUPSOutletGroupTableUpsIndex acsPowerMgmtUPSOutletGroupTableNumber
Column Syntax OID
acsPowerMgmtUPSOutletGroupTablePortNumber
Serial Port number.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.18.1.1
acsPowerMgmtUPSOutletGroupTableUpsIndex
Index.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.18.1.2
acsPowerMgmtUPSOutletGroupTableNumber
Number of the outletgroup in the UPS.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.10418.26.2.5.18.1.3
acsPowerMgmtUPSOutletGroupTableLabel
User-defined label for the outlet group.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.18.1.4
acsPowerMgmtUPSOutletGroupTableState
User-defined label for the outlet group.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.5.18.1.5
acsPowerMgmtUPSOutletGroupTablePowerControl
A set value of power(2-6) will send command to the UPS.
noAction(1) = always returned in a GET. Does nothing if SET.
powerOn(2) = when SET the power On command is sent to UPS.
powerOff(3) = when SET the power Off comma…
Enumerationr/w
Enumerated Values:
1noAction
2powerOn
3powerOff
4powerCycle
.1.3.6.1.4.1.10418.26.2.5.18.1.6
.1.3.6.1.4.1.10418.26.2.7.20 · 1 row entry · 22 columns
This table contains the list of detected external 1-wire sensors.
acsSensors1WireTableEntry entry .1.3.6.1.4.1.10418.26.2.7.20.1
Each entry has the information about the external 1-wire sensor.
Indexes
acsSensors1WireTableIndex
Column Syntax OID
acsSensors1WireTableIndex
Index of detected 1-wire sensor.
Integer32
Constraints:
range: 1-20
.1.3.6.1.4.1.10418.26.2.7.20.1.1
acsSensors1WireTableName
Name of the 1-wire sensor.
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.7.20.1.2
acsSensors1WireTableLocation
Location of the 1-wire sensor.
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.7.20.1.3
acsSensors1WireTableAddress
Address of the 1-wire sensor.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.7.20.1.4
acsSensors1WireTableType
Type of 1-wire sensor.
Enumeration
Enumerated Values:
0sensor-unknown
1external-temperature
2external-humidity
3door-contact
4dry-contact
5leak
6differential-pressure
.1.3.6.1.4.1.10418.26.2.7.20.1.5
acsSensors1WireTableUnit
The unit of the 1-wire sensor.
notApplicable(0) = used for contact or leak sensor
celsius(1) = used for temperature sensor
fahrenheit(2) = used for temperature sensor
percent(3) = used for humidity sensor…
Enumeration
Enumerated Values:
0notApplicable
1celsius
2fahrenheit
3percent
4pa
.1.3.6.1.4.1.10418.26.2.7.20.1.6
acsSensors1WireTableValue
Current sensor reading.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.7.20.1.7
acsSensors1WireTableValueMax
Maximum sensor reading detected. Unit is specified in acsSensors1WireTableUnit.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.7.20.1.8
acsSensors1WireTableValueMin
Minimum sensor reading detected. Unit is specified in acsSensors1WireTableUnit.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.7.20.1.9
acsSensors1WireTableValueAvg
Average sensor reading detected. Unit is specified in acsSensors1WireTableUnit.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.7.20.1.10
acsSensors1WireTableValueLowWarning
If the sensor value falls below this value, an event notification
will be generated. Unit is specified in acsSensors1WireTableUnit.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.7.20.1.11
acsSensors1WireTableValueLowCritical
If the sensor value falls below this value, an event notification
will be generated. Unit is specified in acsSensors1WireTableUnit.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.7.20.1.12
acsSensors1WireTableValueHighWarning
If the sensor value rises above this value, an event notification
will be generated. Unit is specified in acsSensors1WireTableUnit.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.7.20.1.13
acsSensors1WireTableValueHighCritical
If the sensor value rises above this value, an event notification
will be generated. Unit is specified in acsSensors1WireTableUnit.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.7.20.1.14
acsSensors1WireTableReset
A set value of update(2) will reset the 1-wire sensor min/max/avg values.
Enumerationr/w
Enumerated Values:
1noAction
2reset
.1.3.6.1.4.1.10418.26.2.7.20.1.15
acsSensors1WireTableAnalogAlarm
Status of the 1-wire analog sensor alarm.
Used for temperature, humidity, and differential pressure sensors only.
For all other sensor types the value notApplicable(0) will be returned.
Enumerationr/w
Enumerated Values:
0notApplicable
1disabled
2enabled
.1.3.6.1.4.1.10418.26.2.7.20.1.16
acsSensors1WireTableContactAlarm1
Status of the 1-wire contact sensor alarm.
Used for door and dry contact sensors only.
For all other sensor types the value notApplicable(0) will be returned.
Enumerationr/w
Enumerated Values:
0notApplicable
1disabled
2alarmWhenOpen
3alarmWhenClosed
.1.3.6.1.4.1.10418.26.2.7.20.1.17
acsSensors1WireTableContactAlarm2
Status of the 1-wire contact sensor alarm.
Used for door and dry contact sensors only.
For all other sensor types the value notApplicable(0) will be returned.
Enumerationr/w
Enumerated Values:
0notApplicable
1disabled
2alarmWhenOpen
3alarmWhenClosed
.1.3.6.1.4.1.10418.26.2.7.20.1.18
acsSensors1WireTableContactAlarm3
Status of the 1-wire contact sensor alarm.
Used for door and dry contact sensors only.
For all other sensor types the value notApplicable(0) will be returned.
Enumerationr/w
Enumerated Values:
0notApplicable
1disabled
2alarmWhenOpen
3alarmWhenClosed
.1.3.6.1.4.1.10418.26.2.7.20.1.19
acsSensors1WireTableLeakFilterTime
Leak filter time in seconds.
Enumerationr/w
Enumerated Values:
0notApplicable
1filter-time-15
2filter-time-30
3filter-time-60
4filter-time-120
.1.3.6.1.4.1.10418.26.2.7.20.1.20
acsSensors1WireTableLeakAlarm
Status of the leak alarm for the leak sensor.
Used for leak sensors only.
For all other sensor types the value notApplicable(0) will be returned.
Enumerationr/w
Enumerated Values:
0notApplicable
1disabled
2enabled
.1.3.6.1.4.1.10418.26.2.7.20.1.21
acsSensors1WireTableLeakCableFailAlarm
Status of the cable fail alarm for the leak sensor.
Used for leak sensors only.
For all other sensor types the value notApplicable(0) will be returned.
Enumerationr/w
Enumerated Values:
0notApplicable
1disabled
2enabled
.1.3.6.1.4.1.10418.26.2.7.20.1.22
.1.3.6.1.4.1.10418.26.2.7.21 · 1 row entry · 6 columns
This table contains the list of Digital In sensors.
acsSensorsDigitalInTableEntry entry .1.3.6.1.4.1.10418.26.2.7.21.1
Each entry has the information about the Digital In sensor.
Indexes
acsSensorsDigitalInTablePosition
Column Syntax OID
acsSensorsDigitalInTablePosition
Position of the Digital In sensor.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.10418.26.2.7.21.1.1
acsSensorsDigitalInTableName
Name of the Digital In sensor.
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.7.21.1.2
acsSensorsDigitalInTableLocation
Location of the Digital In sensor.
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.10418.26.2.7.21.1.3
acsSensorsDigitalInTableType
Configurable type of Digital In sensor.
Enumerationr/w
Enumerated Values:
0custom
1vibration
2smoke-ad-s
3leak-sn-l
4door
5motion-ad-im
.1.3.6.1.4.1.10418.26.2.7.21.1.4
acsSensorsDigitalInTableValue
Value of the Digital In sensor.
Enumeration
Enumerated Values:
0undefined
1open
2closed
.1.3.6.1.4.1.10418.26.2.7.21.1.5
acsSensorsDigitalInTableAlarm
Status of the Digital In sensor alarm.
Enumerationr/w
Enumerated Values:
1disabled
2alarmWhenOpen
3alarmWhenClosed
.1.3.6.1.4.1.10418.26.2.7.21.1.6
.1.3.6.1.4.1.10418.26.2.8.2 · 1 row entry · 37 columns
This table contains information about the ACS modems,
including auxiliary port built-in modem, pluggable USB
modems, and serial port modems.
acsModemsTableEntry entry .1.3.6.1.4.1.10418.26.2.8.2.1
Each entry has the information about a specific modem.
Indexes
acsModemsTableNumber
Column Syntax OID
acsModemsTableNumber
A unique index representing an entry in this table.
Integer32
Constraints:
range: 1-49
.1.3.6.1.4.1.10418.26.2.8.2.1.1
acsModemsTableDeviceName
The associated device name for the modem.
OctetString
Constraints:
range: 0-25
.1.3.6.1.4.1.10418.26.2.8.2.1.2
acsModemsTableStatus
Enables or disbles the modem.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.10418.26.2.8.2.1.3
acsModemsTableProfile
The modem profile. For an integrated cell modem, only dial-out(3) is valid.
Enumerationr/w
Enumerated Values:
1unconfigured
2dialIn
3dialOut
.1.3.6.1.4.1.10418.26.2.8.2.1.4
acsModemsTablePhoneNumber
The dial-out phone number. Only supported if acsModemsTableProfile is
set to dial-out(3). Not used for integrated cellular modem.
OctetStringr/w
Constraints:
range: 0-25
.1.3.6.1.4.1.10418.26.2.8.2.1.5
acsModemsTableComSpeed
The modem speed. Speeds above 230400 not supported by serial port modems.
Enumerationr/w
Enumerated Values:
1200speed1200
2400speed2400
4800speed4800
9600speed9600
19200speed19200
38400speed38400
57600speed57600
115200speed115200
230400speed230400
460800speed460800
921600speed921600
.1.3.6.1.4.1.10418.26.2.8.2.1.6
acsModemsTableInitChat
Modem initialization string.
OctetStringr/w
Constraints:
range: 0-1200
.1.3.6.1.4.1.10418.26.2.8.2.1.7
acsModemsTablePppAddressConfig
Supported only if acsModemsTableProfile is set to dial-out(2).
If none(1) or remote(3) is set, then the IP address fields will be cleared.
When at least one IP address is set, this value will be local(2).
If remote(3) i…
Enumerationr/w
Enumerated Values:
0notApplicable
1none
2local
3remote
.1.3.6.1.4.1.10418.26.2.8.2.1.8
acsModemsTableLocalIpv4Address
Configures the local IPv4 address for the PPP connection.
OctetStringr/w
Constraints:
range: 0-46
.1.3.6.1.4.1.10418.26.2.8.2.1.9
acsModemsTableRemoteIpv4Address
Configures the remote IPv4 address for the PPP connection.
OctetStringr/w
Constraints:
range: 0-46
.1.3.6.1.4.1.10418.26.2.8.2.1.10
acsModemsTableLocalIPv6Address
Configures the local IPv6 address for the PPP connection.
OctetStringr/w
Constraints:
range: 0-46
.1.3.6.1.4.1.10418.26.2.8.2.1.11
acsModemsTableRemoteIPv6Address
Configures the remote IPv6 address for the PPP connection.
OctetStringr/w
Constraints:
range: 0-46
.1.3.6.1.4.1.10418.26.2.8.2.1.12
acsModemsTablePppAuthentication
Configure the PPP authentication protocol. If this is set to remoteChap(5) or
remotePap(6), then you must also set acsModemsTablePppRemoteUsername
and acsModemsTablePppRemotePassphrase.
Enumerationr/w
Enumerated Values:
1noAuth
2localPap
3localChap
4localEap
5remoteChap
6remotePap
.1.3.6.1.4.1.10418.26.2.8.2.1.13
acsModemsTablePppRemoteUsername
Only used if acsModemsTablePppAuthentication is set to
remoteChap(5) or remotePap(6).
OctetStringr/w
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.8.2.1.14
acsModemsTablePppRemotePassphrase
Only used if acsModemsTablePppAuthentication is set to
remoteChap(5) or remotePap(6).
OctetStringr/w
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.8.2.1.15
acsModemsTableChapInterval
CHAP Interval in seconds. Default is 0.
Not used for integrated cellular modem.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.8.2.1.16
acsModemsTableChapMaxChallenge
CHAP Max Challenge value in seconds. Default is 10 seconds.
Not used for integrated cellular modem.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.8.2.1.17
acsModemsTableChapRestart
CHAP Restart value in seconds. Default is 3 seconds.
Not used for integrated cellular modem.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.8.2.1.18
acsModemsTablePppIdleTimeout
PPP idle timeout value in seconds. Default is 0.
Not used for integrated cellular modem.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.8.2.1.19
acsModemsTableModel
Modem vendor model name. Only used for integrated cellular modem.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.8.2.1.20
acsModemsTableCellProvider
Cellular modem service provider. Only used for integrated cellular modem.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.8.2.1.21
acsModemsTableCellRegistration
Cellular modem network registration. Only used for integrated cellular modem.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.8.2.1.22
acsModemsTableCCID
SIM integrated circuit card identifier. Only used for integrated
cellular modem.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.8.2.1.23
acsModemsTableIMSI
International mobile subscriber identity. Only used for integrated
cellular modem.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.8.2.1.24
acsModemsTableIMEI
International mobile equipment identity. Only used for integrated
cellular modem.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.8.2.1.25
acsModemsTableCellStatus
Shows the status of the cellular modem. Only used for integrated
cellular modem.
OctetString
Constraints:
range: 0-80
.1.3.6.1.4.1.10418.26.2.8.2.1.26
acsModemsTableAPN
Access point name. Only used for integrated cellular modem.
OctetStringr/w
Constraints:
range: 0-40
.1.3.6.1.4.1.10418.26.2.8.2.1.27
acsModemsTableMtuSize
The maxiumum transmission unit size for use by the integrated cellular modem.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10418.26.2.8.2.1.28
acsModemsTableReplaceDefaultRoute
If this is set to enabled(2), then the integrated cellular modem
becomes the default gateway. Only used for integrated cellular
modem.
Enumerationr/w
Enumerated Values:
0notApplicable
1disabled
2enabled
.1.3.6.1.4.1.10418.26.2.8.2.1.29
acsModemsTablePersistMode
If this is set to 'yes' then the integrated cellular modem connection persists.
Only used for integrated cellular modem.
Enumerationr/w
Enumerated Values:
0notApplicable
1disabled
2enabled
.1.3.6.1.4.1.10418.26.2.8.2.1.30
acsModemsTableSignalQualityCheck
Check the signal quality of the integrated cellular modem. This
turns on the modem transceiver to get the signal. The signal quality can be read
in acsModemsTableSignalQualityDisplay.
Enumerationr/w
Enumerated Values:
0notApplicable
1no-action
2signalCheck
.1.3.6.1.4.1.10418.26.2.8.2.1.31
acsModemsTableSignalQualityDisplay
Displays the last read signal quality of the integrated cellular modem.
To refresh this value write signalCheck(2) to acsModemsTableSignalQualityCheck.
OctetStringr/w
Constraints:
range: 0-80
.1.3.6.1.4.1.10418.26.2.8.2.1.32
acsModemsTableSIMStatus
Status of the modem SIM card. Only used for integrated cellular modem.
Enumeration
Enumerated Values:
0unknown
1ready
2waitingForPIN
3waitingForUnlockCode
4errorReadingSIM
.1.3.6.1.4.1.10418.26.2.8.2.1.33
acsModemsTableSIMPINEntry
Modem SIM card PIN/Password entry. Writable only if acsModemsTableSIMStatus
returns waitingForPIN(2). Only used for integrated cellular modem.
OctetStringr/w
Constraints:
range: 0-80
.1.3.6.1.4.1.10418.26.2.8.2.1.34
acsModemsTableSIMUnlockCodeEntry
Modem SIM card Unlock Code entry. Writable only if acsModemsTableSIMStatus
returns waitingForUnlockCode(3). Only used for integrated cellular modem.
OctetStringr/w
Constraints:
range: 0-80
.1.3.6.1.4.1.10418.26.2.8.2.1.35
acsModemsTableCellTestLastStarted
The timestamp of the last time the Cell Modem IP Test started running.
Only used for integrated cellular modem.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.10418.26.2.8.2.1.36
acsModemsTableCellTestLastResult
The result of the last time the Cell Modem IP Test was run.
Only used for integrated cellular modem.
OctetString
Constraints:
range: 0-256
.1.3.6.1.4.1.10418.26.2.8.2.1.37